The Heavy Ion Fusion Virtual National Laboratory Experimental Evaluation of a Negative Ion Source for a Heavy Ion Fusion Driver L. R. Grisham (PPPL) S.K.

Slides:



Advertisements
Similar presentations
Plasma Window Options and Opportunities for Inertial Fusion Applications Leslie Bromberg Ady Herskovitch* MIT Plasma Science and Fusion Center ARIES meeting.
Advertisements

General Characteristics of Gas Detectors
Chapter 3: Matter and Its Changes
Mass spectroscopy. In a typical MS procedure:  1- a sample is loaded onto the MS instrument, and undergoes vaporization.  2- the components of the sample.
Mass Spectroscopy Skyline IB Chemistry HL Mass Spectroscopy.
1 Introduction to Plasma Immersion Ion Implantation Technologies Emmanuel Wirth.
Mass Spectrometry Introduction:
Systems Analysis for Modular versus Multi-beam HIF Drivers * Wayne Meier – LLNL Grant Logan – LBNL 15th International Symposium on Heavy Ion Inertial Fusion.
Fusion Physics - Energy Boon or Nuclear Gloom? David Schilter and Shivani Sharma.
Beamline Design Issues D. R. Welch and D. V. Rose Mission Research Corporation W. M. Sharp and S. S. Yu Lawrence Berkeley National Laboratory Presented.
Triangle Universities Nuclear Laboratory July 26, 2001-TUNL REU The Making and Using of Spin-Polarized H  and D  Beams.
Beam Interaction with Chamber Aerosols D. R. Welch and D. V. Rose, MRC C. L. Olson, SNL S. S. Yu, LBNL October 2-4, 2002 Presented at the ARIES Project.
Mass Spectrometry.
Surface and volume production of negative ions in a low-pressure plasma E. Stoffels, W.W. Stoffels, V.M. Kroutilina*, H.-E. Wagner* and J. Meichsner*,
Diversion of Plasma in Beam Port with a Vertical Magnetic Field D. R. Welch, D. V. Rose, S. S. Yu and W. Sharp Presented at the ARIES Project Meeting April.
OPTIMIZATION OF O 2 ( 1  ) YIELDS IN PULSED RF FLOWING PLASMAS FOR CHEMICAL OXYGEN IODINE LASERS* Natalia Y. Babaeva, Ramesh Arakoni and Mark J. Kushner.
Types and properties of electricity Unit-1 Class- X.
Calderglen High School
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
Remote Plasma Sputtering: Recent Developments in Understanding the Process S. Thornley, P. Hockley, M. Thwaites, J. Dutson Dr James Dutson Senior Development.
TOF Mass Spectrometer &
Ion Beam Cocktail Development and ECR Ion Source Plasma Physics Experiments at JYFL Olli Tarvainen 11th International Conference on Heavy Ion Accelerator.
Chapter 24 Electric Current. The electric current I is the rate of flow of charge through some region of space The SI unit of current is Ampere (A): 1.
Covalent Bonding Chapter 8.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
The nucleus. Rutherford's nuclear atom (1902 ‑ 1920) Ernest Rutherford was interested in the distribution of electrons in atoms. Two of his students,
Fundamental Chemical Laws
Understanding mass spectroscopy. Mass spectroscopy is a very powerful analytical tool that can provide information on the molecular mass of a compound,
40 Nuclear Fission and Fusion After fusion, the total mass of the light nuclei formed in the fusion process is less than the total mass of the nuclei that.
Ursel Fantz for the IPP-NNBI Team 16 th ICIS, New York City, USAAugust 23-28, 2015 Towards 20 A Negative Hydrogen Ion Beams for Up to 1 hour: Achievements.
Isotopes Atoms with the same number of protons, but different numbers of neutrons. Atoms of the same element (same atomic number) with different mass numbers.
Why plasma processing? (1) UCLA Accurate etching of fine features.
Optimum Plasma Grid Bias in a Negative Hydrogen Ion Source Operation with Caesium M. Bacal 1, M. Sasao 2, M. Wada 3, R. McAdams 4 1 UPMC, LPP, Ecole Polytechnique,
Chapter 8 Periodic Properties of the Elements. Trend in Atomic Radius – Main Group Different methods for measuring the radius of an atom, and they give.
Lecture 7: Matter and Energy. Last Time… forms of energy: forms of energy:  kinetic  potential  radiative Law of Conservation of Energy Law of Conservation.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Introduction to Plasma- Surface Interactions Lecture 3 Atomic and Molecular Processes.
Sputter deposition.
Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA U N C L A S S I F I E D Slide 1 Dynamic Electron Injection for Improved.
Ionization Detectors Basic operation
Starter: Spec links 1.06–1.10. Green pens out! Spec links 1.06–1.10.
MATTER 1.1ATOMS AND MOLECULES MATTER CONTENTS Define relative atomic mass and relative molecular mass based on the C-12 scale Analyze mass spectra in.
High gradient acceleration Kyrre N. Sjøbæk * FYS 4550 / FYS 9550 – Experimental high energy physics University of Oslo, 26/9/2013 *k.n.sjobak(at)fys.uio.no.
Investigation of the Boundary Layer during the Transition from Volume to Surface Dominated H − Production at the BATMAN Test Facility Christian Wimmer,
-Plasma can be produced when a laser ionizes gas molecules in a medium -Normally, ordinary gases are transparent to electromagnetic radiation. Why then.
X-ray absorption spectroscopy (XAS)
The Heavy Ion Fusion Virtual National Laboratory Neutralized Transport Experiment (NTX) P. K. Roy, S. S. Yu, S. Eylon, E. Henestroza, A. Anders, F. M.
Large Area Plasma Processing System (LAPPS) R. F. Fernsler, W. M. Manheimer, R. A. Meger, D. P. Murphy, D. Leonhardt, R. E. Pechacek, S. G. Walton and.
THE MASS SPECTROMETER describes how a mass spectrum is produced using a mass spectrometer.
53rd Annual Meeting of the Division of Plasma Physics, November , 2011, Salt Lake City, Utah When the total flow will move approximately along the.
The Heavy Ion Fusion Virtual National Laboratory Ion Source and Injector Experiments at the HIF/VNL J. W. Kwan, D. Baca, E. Henestroza, J. Kapica, F. M.
The Heavy Ion Fusion Virtual National Laboratory Erik P. Gilson** PPPL 15 th International Symposium on Heavy Ion Fusion June 9 th, 2004 Research supported.
Isotopes and abundance. The relative atomic mass scale is now based on an isotope of carbon, carbon-12, which is given the value of amu.
Saturn Magnetosphere Plasma Model J. Yoshii, D. Shemansky, X. Liu SET-PSSD 06/26/11.
Mass Spectrometry u Chapter 12 Chapter 12.
Chapter 8 Covalent Bonding
SPES Target Group Data…… INFN-CISAS-CNR collaboration The Ablation Ion Source for refractory metal ion beams A preliminary design.
THE MASS SPECTROMETER WHAT IS A MASS SPECTROMETER
Seok-geun Lee, Young-hwa An, Y.S. Hwang
Wakefield Accelerator
Mass Spectrometry.
5.3 Properties and Phases of Matter
1.6 Glow Discharges and Plasma
Covalent Bonding.
Shukui Zhang, Matt Poelker, Marcy Stutzman
Chemistry/Physical Setting
Presentation transcript:

The Heavy Ion Fusion Virtual National Laboratory Experimental Evaluation of a Negative Ion Source for a Heavy Ion Fusion Driver L. R. Grisham (PPPL) S.K. Hahto, S. T. Hahto, J.W. Kwan, K. N. Leung (LBNL) HEAVY ION FUSION 2004 Conference Princeton, New Jersey June , 2004

The Heavy Ion Fusion Virtual National Laboratory Features of Negative Ion Drivers a Negative ion beams will not draw electrons from surfaces, so focusing properties will not be contaminated (no electron clouds). a Negative halogen beams extracted from ion source should not have the low energy exchange tails of positive ions. a If eventually want atomic beams, negative ions can be efficiently converted to atomic beams with photodetachment neutralizers. a For sufficiently low target chamber pressures, atomic driver beams would reduce average beam self perveance and spot size.

The Heavy Ion Fusion Virtual National Laboratory Critical Technical Issues a Choice of beam element (mention in this talk) a Ion source (subject of this talk) a Photodetachment neutralizer (HIF 2002) a Vacuum requirements in accelerator and beam transport system (HIF 2002) a Ionization of beam particles in target chamber (HIF 2002)

The Heavy Ion Fusion Virtual National Laboratory Choice of Beam Element a Electron affinity determines ease of producing negative ions. a The halogens F, Cl, I, and Br all have high electron affinities over 3 eV. a Bromine (mass 81, affinity 3.63 eV) and iodine (mass 127, affinity 3.06 eV) are probably the best mass choices for a heavy ion driver, but require heated sources to produce vapor. a Fluorine (mass 19, affinity 3.45 eV) and chlorine (mass 37, affinity 3.61 eV) are the easiest choices for a proof-of-principle source because they are diatomic gases at room temperature. a In the semiconductor industry, Cl - is the dominant negative ion in RF discharges at mtorr.

The Heavy Ion Fusion Virtual National Laboratory Ion Sources a RF- driven plasma sources should be able to produce high current densities of F, Cl, I, or Br because they all have high electron affinities. a Form negative ions by dissociative attachment of electron to vibrationally excited dimers, similar to process in volume D - sources. a With adequate negative ion density in plasma, extractable negative ion current density will be determined by the strength of the extraction electric field, which is a function of the extractor design, not the ion polarity. a Thus, the extractable current densities of negative ions of F, Cl, I, or Br should be similar to the extractable current densities of positive ions of similar masses. a Unlike hydrogen negative ion sources, halogen negative ion sources should not require the addition of cesium.

The Heavy Ion Fusion Virtual National Laboratory Co-extracted Electrons from Ion Source a In D - sources with no electron suppression, electrons extracted from the source plasma will outnumber the negative ions in the beam by the ratio of their mobilities (roughly the square root of the ratio of their masses) multiplied by their relative abundance in the near-extractor plasma and the rato of the electron/ion temperatures. a In D - ion sources, electron suppression techniques reduce co-extracted electron component by factors of order a 100 or more. a Electron suppression techniques include: –Uniform magnetic filter field in extraction plane. –Biasing extractor by a few volts relative to plasma. –Small permanent magnets in extractor to dump remaining electrons after extraction stage before further acceleration. –Addition of massive positive ions to plasma to impede electrons. –Massive negative ions are only slightly affected by the magnetic fields that deflect the electrons (relative magnetic rigidity is proportional to the square root of the ratio of their masses).

The Heavy Ion Fusion Virtual National Laboratory Experimental Setup for Negative Chlorine Experiments

The Heavy Ion Fusion Virtual National Laboratory Positive Cl Spectrum is 82% Atomic; Contains Molecular Ions and Contaminants, and Charge Exchange Tails

The Heavy Ion Fusion Virtual National Laboratory Negative Chlorine Spectrum is 99.5% Atomic, with Negligible Tails

The Heavy Ion Fusion Virtual National Laboratory System Tested With Oxygen, which has Electron Affinity of 1.46 eV

The Heavy Ion Fusion Virtual National Laboratory Negative Oxygen Current is Linear with RF Power

The Heavy Ion Fusion Virtual National Laboratory Chlorine, with Electron Affinity of 3.61 eV, Yields More Negative Ions and Fewer Electrons Than Oxygen with Affinity of 1.46 eV

The Heavy Ion Fusion Virtual National Laboratory Negative Chlorine Current Density Linear with RF

The Heavy Ion Fusion Virtual National Laboratory Smaller Effect of Bias on Electrons in Chlorine Suggests They are a Smaller Portion of the Negative Population than with Oxygen

The Heavy Ion Fusion Virtual National Laboratory Electrons Are Much More Sensitive to Pressure and Filter Position than the Negative Chlorine

The Heavy Ion Fusion Virtual National Laboratory Low Electron Current Probably due to Two Mechanisms Near-equivalence of negative and positive ion densities leaves little room in charge space for electrons near extraction plane. This effect should persist when use heavier halogens. The positive component of the plasma consists of massive Cl +, which retards electron flow to extractor, as observed in H - sources containing Cs + This effect may become more beneficial when use heavier halogens (iodine is nearly as massive as cesium) MFE negative ion sources need magnets in extractor grids to dump electrons because they operate in long pulses, and electrons would otherwise reach full energy; not the case for HIF, might be able to avoid extractor magets (which lower grid transparency)

The Heavy Ion Fusion Virtual National Laboratory Pepper Pot Used for Rough Emittance Comparison of Positive and Negative Chlorine Measured apparent “temperatures” in directions parallel and perpendicular to direction of the electron analysis magnetic field. For positive chlorine ions, parallel “T” was 0.2 eV and perpendicular “T” was 0.5 eV. For negative chlorine ions, parallel “T” was 0.3 eV and perpendicular “T” was 0.5 eV These values are all smaller than is common for positive ions extracted from ion-electron plasmas (2.4 eV for Ar+ from quite similar source). Ion-ion plasmas should have lower ambipolar potentials than ion-electron plasma, as well as shorter gradient lengths, so it may be that both positive and negative ions have lower T eff than positive ions from ion-electron plasmas.

The Heavy Ion Fusion Virtual National Laboratory Achieved Current Densities a RF source produced 45 mA/cm 2 of Cl - or 53 mA/cm 2 of total positive ions with 2.2 kW of RF power (-/+ ratio of 0.79) a Spectrum was 99.5% negative atomic chlorine; 0.5% negative chlorine molecules; negative spectrum much purer than positive spectrum a At optimized conditions, co-extracted e - current was only 7 times greater than Cl - current, much less than to be expected from the difference in mobilities (240). Ratio was a factor of more favorable with chlorine than with less-electronegative oxygen. a Negative atomic chlorine current density not very sensitive to pressure; scaled linearly with RF power; should scale to around 100 mA/cm 2 at 5 kW (power supply limit was 2.2 kW)

The Heavy Ion Fusion Virtual National Laboratory Halogen Ion Source Characteristics Appear Acceptable for HIF Current densities adequate for HIF, and similar to positive ions (so extractable currents will be limited by extractor design for either negative or positive ions Negligible negative molecular ions or contaminants Negligible charge exchange tails to increase longitudinal emittance Ion-ion plasma results in few co-extracted electrons Perhaps because of low ambipolar potentials and shorter gradient lengths in ion-ion plasmas, T eff of both negative and positive beams appears low, so halogen sources might allow smaller spot size for both positive and negative ions than would positive ions from ion- electron plasmas.

The Heavy Ion Fusion Virtual National Laboratory Future Directions for Exploration Tests with Cl on Joe Kwan’s 100 kV Livermore test stand planned Scale to higher RF source power and multiple beamlets Measure Cl +, Cl -, e - currents and emittance Tests with heated source using bromine or iodine (in the future, if the HIF community decides to pursue this approach) Test of small proof-of-concept photodetachment neutralizer (in the future, if the HIF community is interested in the option of neutralizing the beam)

The Heavy Ion Fusion Virtual National Laboratory Best e - /Cl - Ratio Was Obtained at 40 mTorr with a Different Antenna (which Broke)