Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?

Slides:



Advertisements
Similar presentations
Potentiometric Methods
Advertisements

Potentiometric Methods A.) Introduction:
Summary of Potentiometry:
Introduction to Analytical Chemistry
Chapter 10: Acids and Bases When we mix aqueous solutions of ionic salts, we are not mixing single components, but rather a mixture of the ions in the.
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
ISE Ion Selective Electrodes Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Electroanalytical – Introduction Ch 21, 7th e, WMDS)
Measuring concentration using electrodes Indicator electrodes used with reference electrode to measure potential of unknown solution E cell = E indicator.
POTENTIOMETRY 9th lecture
Dr. Marc Madou Class IV. Microfabrication of electrochemical sensors Winter 2011 BIOMEMS.
Electrodes and Potentiometry
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
14-6 Cells as chemical probes
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Analytical Electrochemistry : Potentiometry
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Potentiometry and the Detection of Fluoride
Potentiometric Methods
RESTING MEMBRANE POTENTIAL
Composition Dependence of ΔG ( ) For a mixture, the Gibbs energy also depends on the composition of the mixture – The dependence on the change in.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chemical Buffers Edward A. Mottel Department of Chemistry Rose-Hulman Institute of Technology.
THE HYDRONIUM ION The proton does not actually exist in aqueous solution as a bare H + ion. The proton exists as the hydronium ion (H 3 O + ). Consider.
Acid-Base Equilibria Acids and bases are some of the more commonly encountered chemicals Acids and Bases control composition of blood and cell fluids,
(8.3) Acid-Base Properties of Salt Solutions. pH Review  Recall Acidic [H 3 O + ] > [OH - ] Basic [H 3 O + ] < [OH - ] Neutral [H 3 O + ] = [OH - ]
Chapters 14 and 15. Aqueous solutions have a sour taste. Acids change the color of acid-base indicators. Some acids react with active metals to release.
Buffers of Biological & Clinical Significance Lecture 4 Lecturer: Amal Abu Mostafa Lecture 4 Lecturer: Amal Abu Mostafa 1 Clinical Analytical Chemistry.
 Transportation of Materials Across the Cell Membrane 1.
Electroanalytical methods
Prentice Hall ©2004 Chapter 14 Aqueous Equilibria: Acids and Bases.
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Unit 2 Electrochemical methods of Analysis
Part II. Polyprotic acid H 2 CO 3 H + + HCO 3 - Ka 1 = 4.3 x H 2 CO 3 H + + HCO 3 - Ka 1 = 4.3 x HCO 3 - H + + CO 3 -2 Ka 2 = 4.3 x
Chapter 4 Cells and their Environment
ECF and ICF show no electrical potential (0 mV).
1. Atoms make up _________.. 2. Molecules make up ___________.
Biochemical Reactions Chemistry in Biology Chapter 6.
Acid-Base Equilibria. Acids Bases Sour taste React with active metals to release hydrogen gas Change the color of indicators Bitter taste Feel slippery.
Co-ordination and Regulation: Aims: Must be able to outline the main forms of fluid in the body how substances are transferred. Should be able to outline.
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
Chapter 15 Electrode Measurements “Chem 7” test in hospital lab. Na +, K +, Cl -, CO 2, glucose, urea, & creatinine ion-selective electrodes.
Chemistry 5.9. Oxidation-Reduction Oxidation- Oxidation- Loss of electrons by an atom or ion. Loss of electrons by an atom or ion. Reduction- Reduction-
Functions of the plasma membrane 1.Holds the cell together 2.Controls what goes in and out (diffusion, osmosis, active transport) 3.Protects the cell.
Chapter 2 – Chemicals of Life $100 $200 $300 $400 $500 $100$100$100 $200 $300 $400 $500 MatterBondingFormulas Chemical Reactions Cells FINAL ROUND.
ESSENTIALS OF BODY CHEMISTRY MATTER, ELEMENTS, AND ATOMS MATTER-anything that occupies space and has mass MATTER-anything that occupies space and has.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
POTENTIOMETRY.
Chapter 21 Potentiometry. Potentiometric methods of analysis are based on measuring the potential of electrochemical cells without drawing appreciable.
Ch. 21 Potentiometry 1. General principles
Acids and Bases Ch.14/15. The Battle to define them Arrhenius was first in 1884 Acids: something that produces H + ions in solution. Bases: something.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Biochemical Reactions SBI4U1. Acids produces H + ions in H 2 O pH below 7 Sour taste, conducts electricity Increase [H + ] or [H 3 O + ] ions when dissolved.
7. Electroactive and Electro Optical Polymers (Chapter 23)
SCI3023 ELECTROCHEMISTRY Chapter 8e: Potentiometry
Cagri Ozge Topal OSU ECEN 5060 Nanotechnology
Titration and Buffers Buffers Buffers are substances that are able to absorb and release H+ ions keeping the pH in a solution constant. – EX: H 3 O + +
Recap – Last Lecture An acid is a proton donor A base is a proton acceptor A conjugate pair differ by H + Strong A/B is completely dissociated Weak A/B.
Electrochemistry MAE-212
Ion Selective Electrode
Potentiometry and potentiometric measurements
Biosensors Definition
Ion Selective Electrode
Potentiometry Potential measurements of electrochemical cells
Atomic Structure and Properties
Chapter 23 Potentiometry.
Cell physiology.
Acids and Bases Chapters 14 and 15.
Presentation transcript:

Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?

Fall 2014, Prof. JB Lee Indicator electrode: ISEs  Ion selective electrodes (ISEs)  Fritz Haber discovered (1901) that there is a change in potential across a glass membrane when its two sides are in solutions of different acidity.  This led to the development of a new class of indicator electrodes called ISEs.  In addition to the glass pH electrode, ISEs are available for a wide range of ions. The development of new ISEs continues to be an active area of research.  The ISE’s membrane separates the sample, which contains the analyte at an activity of (a A ) sample, from an internal solution containing the analyte with an activity of (a A ) int.  Because the junction potential and the potential of the two reference electrodes are constant, any change in E cell is a result of a change in the membrane’s potential. E cell = E ref(int) − E ref(sample) + E mem + E j

Fall 2014, Prof. JB Lee By the way, what is pH again?  pH is the measurement of acidity (hydrogen ion concentration)  pH = -log 10 [H + ], for [H + ] = 1.8 x M, pH =  An important example of pH is that of the blood. Its nominal value of pH = 7.4 is regulated very accurately by the body. If the pH of the blood gets outside the range 7.35 to 7.45 the results can be fatal.

Fall 2014, Prof. JB Lee ISE: glass pH electrode  Glass pH electrode  pH sensitive glasses are manufactured typically with a composition ~22% Na 2 O, ~6% CaO and ~72% SiO 2.  Oxygen atoms within the lattice that are not bound to two Si atoms possess a negative charge. Cations (primarily Na + ) pair with these oxygen atoms and are able to diffuse slowly in the lattice, moving from one charge pair site to another. This movement of cations within the glass allows a potential to be measured across it.  Advantages  Its potential is essentially not affected by the presence of oxidizing or reducing agents.  Operates over a wide pH range  Fast  Functions well in physiological systems.

Fall 2014, Prof. JB Lee Gas-sensing electrodes  Gas-sensing electrodes  A thin membrane that separates the sample from an inner solution containing an ISE.  The membrane is permeable to the gaseous analyte, but impermeable to other components. The gaseous analyte passes through the membrane where it reacts with the inner solution, producing a species whose concentration is monitored by the ISE.  For example, CO 2 diffuses across the membrane where it reacts in the inner solution to produce H 3 O +. The change in the activity of H 3 O + in the inner solution is monitored with a pH electrode  CO 2 (aq) + 2H 2 O(l) ⇋ HCO 3 − (aq) + H 3 O + (aq)  CO 2, HCN, HF, H 2 S, NH 3, NO 2, SO 2 are commonly measured in this manner.

Fall 2014, Prof. JB Lee Potentiometric biosensors  Potentiometric biosensors  Gas-sensing electrodes are modified to create potentiometric electrodes that respond to a biochemically important species.  Potentiometric biosensors have been designed around other biologically active species, including enzymes, antibodies, bacterial particles, tissues, and hormone receptors.  Ex: enzyme (urease) electrode  Urease catalyzes the hydrolysis of urea (CO(NH 2 ) 2 ) to produce NH 3 (ammonia) and CO 2  CO(NH 2 ) 2 (aq) + 2H 2 O(l) ⇋ 2NH 4 + (aq) + CO 3 2− (aq)

Fall 2014, Prof. JB Lee Demand for in vivo biosensing

Fall 2014, Prof. JB Lee Why ISFET?  Why do we need ISFET? Strong demand in biomedical sensing (H, K, Na ions) Miniaturized versions of the glass-membrane ion-selective electrode (ISE) appear to be less stable For in vivo monitoring, glass-membrane ISE is fragile and cannot be used  Goals Reduced dimensions to probe biology Fast response Simple integration with measurement electronics  Solution Modify a common electrical engineering device (MOSFET) and use as a sensor (ISFET)

Fall 2014, Prof. JB Lee ISFET – small and reliable Conventional ISE too big, fragile & unstable for in-vivo biosensing applications ISFET small & reliable for in-vivo biosensing applications

Fall 2014, Prof. JB Lee ISFET  ISFET is essentially a type of MOSFET  The metal gate is replaced with electrolytes of interest MOSFET ISFET