Biopotential electrodes

Slides:



Advertisements
Similar presentations
Unit 10 - Electricity.
Advertisements

BIOPOTENTIAL AMPLIFIERS
7th Lecture Dimitar Stefanov. Recapping Three types electrodes are used for sensing of EMG signals: 1.indwelling (intramuscular) electrodes (single fiber.
Chapter 5-Webster Biopotential Electrodes
Biomedical Instrumentation
Chemical equilibrium: electrochemistry 자연과학대학 화학과 박영동 교수.
BIOMEDICAL INSTRUMENTATION
1 IV. Electrodes In order to measure biopotentials, we must convert the ionic activity of the excitable cells of interest to electrical signals. In order.
What is an electric charge?
Biopotential electrodes A complex interface Basics of Instrumentation, Measurement and Analysis 2011, 2012.
Chapter 5. Biopotential Electrodes Michael R. Neuman
Biopotential electrodes A complex interface Summer School Timisoara 2002R. Hinz.
Biopotential Electrodes
Biopotential Electrodes (Ch. 5)
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
The Electrocardiogram
EMG ELECTRODES. Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG is performed.
Biopotential Electrodes III
ELECTROCARDIOGRAM (ECG)
Chapter 20 Electricity. Section 1 Electric charge and static electricity.
Chapter 17 Current Electricity. Conductors  Conductors are materials in which the electric charges move freely Copper, aluminum and silver are good conductors.
Wednesday, Sept. 28, 2005PHYS , Fall 2005 Dr. Jaehoon Yu 1 PHYS 1444 – Section 003 Lecture #9 Wednesday, Sept. 28, 2005 Dr. Jaehoon Yu Quiz Results.
Lecture 6 Dimitar Stefanov.
Sources of electrical energy. The driving force in electronic circuits In Chapter 6, the idea of electromotive force was explained. The electromotive.
Diagnostic electromagnetic equipment. Physical principles electrographic methods in the diagnosis of diseases.
Lesson 2. Galvanic Cells In the reaction between Zn and CuSO 4, the zinc is oxidized by copper (II) ions. Zn 0 (s) + Cu 2+ (aq) + SO 4 2-  Cu 0 (s) +
Pacemaker & its Classification
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
18-3: Capacitance Objectives: Relate capacitance to the storage of electrical potential energy in the form of separated charges. Calculate the capacitance.
Biopotential Electrodes III. Electrodes Recording Stimulating.
Biomedical Electrodes Presented by- Md. Bashir Uddin Roll: Dept. of BME KUET, Khulna-9203.
Wednesday, Feb. 15, 2006PHYS , Spring 2006 Dr. Jaehoon Yu 1 PHYS 1444 – Section 501 Lecture #9 Wednesday, Feb. 15, 2006 Dr. Jaehoon Yu Molecular.
Ch 181 Chapter 18 Electric Currents © 2002, B.J. Lieb.
HAZARD OF MEDICAL INSTRUMENT by Mohd Yusof Baharuddin.
Biomedical Instrumentation
Announcements:. Last lecture 1.Organization of the nervous system 2.Introduction to the neuron Today – electrical potential 1.Generating membrane potential.
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
Electric Circuits. What is Electric Current? Current in a river –The movement of water molecules Higher current = more water passing a given point each.
Electric Charges & Current Chapter 7. Types of electric charge Protons w/ ‘+’ charge “stuck” in the nucleus Protons w/ ‘+’ charge “stuck” in the nucleus.
All All matter is made of atoms. Atoms contain positively charged protons, negatively charged electrons, and neutral neutrons. Opposite Opposite charges.
Tuesday, Sep. 25, PHYS 1444 Dr. Andrew Brandt PHYS 1444 – Section 02 Lecture #9 Chapter 24 Chapter 25 Tuesday Sep. 25, 2012 Dr. Andrew Brandt HW.
Biomedical Electrodes, Sensors, and Transducers
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
CHAPTER 11 ELEMENTS OF ELECTROCHEMISTRY Introduction to Analytical Chemistry.
Electrocardiographs ECG. OUTLINES : Introducing what is meant by Biopotential signals. what is Electrocardiograph (ECG). The conduction system. The standard.
Design of a readout system for RPCs Olu Amoda2 The LODEN Group The group is an association of Fermilab scientists who teamed up to build a cosmic ray.
Tuesday, Feb. 22, PHYS Dr. Andrew Brandt PHYS 1444 – Section 02 Lecture #9 Chapter 24 Chapter 25 Tuesday Feb 22, 2011 Dr. Andrew Brandt.
Electric Current Chapter 34.
Monday, Feb. 19, PHYS , Spring 2007 Dr. Andrew Brandt PHYS 1444 – Section 004 Lecture #9 Mon day, Feb Dr. Andrew Brandt Electric.
Unit D Review Electricity. How can you explain two charged objects “sticking” to one another? Opposite charges, movement of electrons!
Electricity Current and charge. Electricity The flow of an electrical current Electrons flowing from a negatively charged area to a positively charged.
Electric Currents Charges in motion.. Creating Potential Difference. Alessandro Volta ( ) –Ranked potentials created by combing two metal discs.
Figure 5.1 Electrode-electrolyte interface The current crosses it from left to right. The electrode consists of metallic atoms C. The electrolyte is an.
PH meter Bushra mubarak. pH pH is defined as the negative logarithm of the hydrogen ion activity aH. Unit of measure which describes the degree of acidity.
BY Parmar Anjali Singh Sweta
BIO POTENTIAL ELECTRODES. ELECTRODES What is an electrode? Device that converts ‘ionic potentials’ into ‘electronic potentials’ They are employed to pick.
By Suhas Dhenge.  To study the electrical activity of individual cell microelectrodes are employed.  This type of electrode must be small with respect.
Physiologic signals Lecture (2).
CHARGE AND LOAD PROTECTION IN SOLAR POWER MANAGEMENT
Three types electrodes are used for sensing of EMG signals:
Basic Corrosion Theory
Figure 5.1 Electrode-electrolyte interface The current crosses it from left to right. The electrode consists of metallic atoms C. The electrolyte is an.
Biopotential electrodes
Components of bio-medical instrument system
Electrodes: 3 types Types: Micro electrode Depth & needle electrodes
Biopotential electrodes
SOLAR POWER CHARGE CONTROLLER
Biomedical Electronics & Bioinstrumentation
Presentation transcript:

Biopotential electrodes Engr. Hinesh Kumar (Lecturer)

Electrodes for Biophysical Sensing Bioelectricity is a naturally occurring phenomenon that arises from the fact that living organisms are compared of ions in various different quantities. Ionic conduction involves the migration of ions- positively and negatively charged molecules throughout a region. Electronic conduction involves the flow of electrons under the influence of an electrical field.

Cont… Electrical conduction in medical instrument circuits is electronic. Electrical conduction in the body is ionic. Electrodes provide transduction between ionic and electronic conduction. Biopotential electrodes function as sensor that couple the ionic potentials generated inside the body to an electronic instrument.

Bioelectrodes Bioelectrodes are a class of sensors that transduce ionic conduction to electronic conduction so that the signal can be processed in electric circuits. The usual purpose of bioelectrodes is to acquire medically significant bioelectrica1 signals. Such as Electrocardiographic(ECG), Electroencephalographic (EEG), and Electromyographic (EMG). Bioelectrical signals are acquired from one of three forms of electrode: Surface Electrodes, Indwelling Electrodes, and Micro Electrodes

Electrode or Half Cell Potential The skin and other tissues of higher-order organisms, such as humans, are electrolytic and so can be modeled as an Electrolytic Solution. Imagine a metallic electrode immersed in an electrolytic solution. Immediately after immersion, the electrode will begin to discharge some metallic ions into the solution, while some of the ions in the solution start combining with the metallic electrodes. A gradient charge build up, creating a potential difference, or electrode potential and half cell potential.

Cont… A complex phenomenon is seen at the interface between the metallic electrode and the electrolyte. Ions migrate toward one side of the region or another, forming two parallel layers of ions of opposite charge. This region is called the electrode double layer and its ionic differences are the source of the electrode or half-cell potential. Metallic electrode immersed in an electrolytic solution

Electrode Offset Potential When two dissimilar metals immersed in a common electrolytic solution, they both form the Half cell potential. The differential potential between these two Half cell potential is called an electrode offset potential.

Electrode or Half Cell Potential The Half-cell potential of the electrode depends on: The used metals, The electrolyte composition The temperature Different material exhibits different half-cell potentials

Polarizable and Non-Polarizable Electrode Perfectly Polarizable Electrodes Perfectly polarizable electrodes are those in which no actual charge crosses the electrode–electrolyte interface when a current is applied. Of course, there has to be current across the interface and the electrode behaves as though it were a capacitor Perfectly Polarizable Electrodes or Perfectly Reversible Perfectly non-polarizable electrodes are those in which current passes freely across the electrode–electrolyte interface, requiring no energy to make the transition. Thus, for perfectly non-polarizable electrodes there are no over-potentials. Electrode interface impedance is represented as a resistor.

Medical Surface Electrodes Surface electrodes are those that are placed in contact with the skin of the subject. Also in this category are certain needle electrodes of a sire that prevents their being inserted in the cell. A conductive gel or paste is used to reduce the impedance between the electrode and skin.

Cont… Human skin tends to have a very high impedance compared with other voltage sources. Typically, normal skin impedance, as seen by the electrode. For sweaty skin varies from 0.5 k Ω For dry skin surfaces to more than 20 k Ω Problem skin especially, dry, scaly, or diseased skin, may reach impedances in the 500 k Ω range.

Types of Biopotential Electrodes Bioelectrical signals are acquired from one of three forms of electrode: Body Surface Electrodes, Needle Electrodes Micro Electrodes

Body Surface Electrodes There are four different types of body surface recording electrodes; Column Electrodes Suction Electrodes Floating Electrodes Flexible Electrodes

Column Electrodes The electrode consists of a silver-silver chloride metal contact button at the top of a hollow column that is filled with a conductive gel or paste. This assembly is held in place by the adhesive coated foam rubber disk The use a gel filled or paste filled column that holds the actual metallic electrode off the surface reduces movement artifact. Far this reason the column electrodes are preferred for monitoring hospitalized patients.

Column Electrodes Large surface: Earliest, and still used for ECG. Smaller diameters. Used for ECG, EMG and EEG. Susceptible to Motion artifacts. Disposable foam-pad. Very Cheap. Used for long term recording

Figure (a): Metal-plate electrode used for application to limbs. Figure (b): Metal-disk electrode applied with surgical tape. Figure (c): Column electrodes, often used with ECG.

Suction Cup Electrodes Straps or adhesives not required. Often used for precordial (chest) ECG. For short periods only.

Floating Electrodes Metal disk is recessed. Floating in the electrolyte gel. Not directly contact with the skin. Reduces motion artifacts. Figure (a): Recessed electrode with top-hat structure. Figure (b): Cross-sectional view of the reusable electrode in (a).

Flexible Electrodes Body surface are often irregular. Regularly shaped rigid electrodes may not always work. Special case : infants. Material: polymer or nylon with silver, carbon filled silicon rubber (Mylar film). Figure (a): Carbon-filled silicone rubber electrode, Figure (b): Flexible thin-film neonatal electrode. Figure (c): Cross-sectional view of the thin-film electrode in (b).

Problems with Surface Electrode Several problems are associate with all types of surface electrodes: Adhesive will not stick for long on sweaty or clammy skin surfaces. Fleshy portion of chest and abdomen are selected as electrode site. After 8 hour change the electrode to avoid the ischemia. Movement Artifacts Electrode position slips

Needle Electrode This type of electrode is inserted into the tissue immediately beneath the skin by puncturing the skin at a large oblique angle (i.e.,close to horizontal with respect to the skin surface). The needle electrode is only used for exceptionally poor skin, especially an anesthetized patients, and in veterinary situations. Of course, infection is an issue in these cases, so needle electrodes are either disposable (one time use) or are resterilized in ethylene oxide gas.

Cont… Needle and wire electrodes for percutaneous measurement of Biopotentials. Figure: Insulated needle electrode, Coaxial needle electrode, Bipolar coaxial electrode, Fine-wire electrode connected to hypodermic needle, before being inserted, Cross-sectional view of skin and muscle, showing fine-wire electrode in place, Cross-sectional view of skin and muscle, showing coiled fine-wire electrode in place.

Indwelling Electrode lndwelling electrodes are intended to be inserted into the body. These are not to be confused with needle electrodes, which are intended for insertion into the layers beneath the skin The indwelling electrode is typically a tiny, exposed metallic contact at the end of a long, insulated catheter. In one application, the electrode is threaded through the patient's veins (usually in the right arm) to the right side of the heart to measure the intracardiac ECC waveform.

Cont… Certain low amplitude, high-frequency features (such as the signal from bundle of His) become visible only when an indwelling electrode is used.

Fetal ECG Electrodes Electrodes for detecting fetal electrocardiogram during labor. Figure (a): Suction electrode, Figure (b): Cross-sectional view of suction electrode in place, showing penetration of probe through epidermis, Figure (c): Helical electrode, that is attached to fetal skin by corkscrew-type action.

EEG Electrodes The brain produce bioelectric signals that can be picked up through surface electrodes attached to the scalp. These electrodes will be connected to an EEG amplifier that driver either an oscilloscope or strip chart recorder. Typical Needle electrode is used. The disc electrode have 1cm diameter concave disc made either of silver and gold. The disc electrode in a place by a thick paste that is highly conductive, or by a headband in certain monitoring applications.

Microelectrode The microelectrode is an ultrafine device that is used to measure biopotentials at the cellular level. In practice, the microelectrode penetrates a cell that is immersed in an infinite fluid (such as physiological saline), which is in turn connected to a reference electrode. Although several types of microelectrodes exist, most of them are of one of two basic forms: metallic-contact or fluid-filled. In both cases, an exposed contact surface is about 1to 2 um is in contact with cell.

Microelectrode used to measure the cellular potential

Microelectrodes There are three major types of microelectrode. Solid Metal Electrodes (Tungsten Microelectrodes) Glass-Metal or Supported Metal Electrodes (metal contained within/outside glass needle) Fluid-Filled Electrodes (with Ag-AgCl electrode metal)

Solid Metal Electrode

Glass-Metal Electrodes A very fine platinum or tungsten wire is slip-fit through a 1.5 to 2 mm glass pipette. The electrode can then be connected to one input of the signals amplifier. There are two subcategories of glass-metal electrodes. In the first type, the metallic tip is flush with the end of the pipette taper. In the second type, a thin layer of glass covers the metal point. This glass layer is so thin that it requires measurement in angstroms (1 angstrom = 1.0 × 10-10 meters) and it drastically increases the impedance of the device.

Fluid-Filled Electrodes The fluid-filled glass microelectrode is shown in the fig. In this type of electrode, the glass pipette is filled with a solution of potassium chloride (KCI), and the large end is capped with an silver-silver chloride (Ag-Ag Cl) plug. The small end need not be capped because the 1μm opening is small enough to contain the fluid. The reference electrode is likewise filled with potassium chloride (KCI), but is much larger than the microelectrode. A platinum plug contains fluid on the interface end, while an silver-silver chloride (Ag-Ag Cl) plug caps the other end.

Assignment Biosensor..? Principle and how it works ? Advantages and Disadvantages?