File Name: pH.pptFeb 2001 pH Theory Applied to Proper Hardware Selection.

Slides:



Advertisements
Similar presentations
Post Lab: Electrolytes
Advertisements

Chapter 9 Chemical Change
File Name: Conductivity.pptFeb 2001 Conductivity Theory Applied to Proper Hardware Selection.
CHEM 213 Instrumental Analysis
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
Summary of Potentiometry:
AQUEOUS EQUILIBRIA AP Chapter 17.
Electricity from Chemical Reactions
Chemical equilibrium: electrochemistry 자연과학대학 화학과 박영동 교수.
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Level 1 pH Theory.
Tracking Reaction Progress via Electrochemical Methods.
Biopotential electrodes A complex interface Basics of Instrumentation, Measurement and Analysis 2011, 2012.
ISE Ion Selective Electrodes Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
POTENTIOMETRY 9th lecture
Electrodes and Potentiometry
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
PH pH is a unit of measure which describes the degree of acidity or alkalinity (basic) of a solution. It is measured on a scale of 0 to 14. The formal.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
ACADs (08-006) Covered Keywords analytical balance, conductivity bridge with flow cell, inductively coupled plasma analyzer, in-line sodium monitor, ion.
Chemistry 1011 Slot 51 Chemistry 1011 TOPIC Electrochemistry TEXT REFERENCE Masterton and Hurley Chapter 18.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Types of Chemical Reactions and Solution Stoichiometry
Please select a Team. 1.Team 1 2.Team 2 3.Team 3 4.Team 4 5.Team 5.
Unit 1 – Day 12 Solubility Rules.
IC Controls Quality Water Solutions for pH R1.0 © 2004 IC CONTROLS pH / ORP Conductivity Dissolved Oxygen Chlorine Standards An Overview.
C h a p t e rC h a p t e r C h a p t e rC h a p t e r 4 4 Reactions in Aqueous Solution Chemistry, 5 th Edition McMurry/Fay Chemistry, 5 th Edition McMurry/Fay.
 The ability to dissolve or break down into its component ions in a liquid  Example:  NaCl is soluble  Completely dissolves in water  AgCl is insoluble.
POTENTIOMETRY 8th lecture
pH and Conductivity Best Practices
Acids and Bases Biotechnology I. Life Chemistry  Based on water  Cells contain 80-90% water  Proper pH essential to ALL living systems Plants cannot.
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
Experts in Chem-Feed and Water Treatment Chlorine Chemistry.
Types of Chemical Reactions and Solution Stoichiometry Chapter 4.
Unit 7: Solutions, Acids, & Bases. I. Definitions and Types of Solutions A. What exactly IS a Solution?
Chemistry. Session Electrochemistry - 2 Session Objectives Electrolysis Faradays Laws of electrolysis Electrode Potential Electromotive force Electrochemical.
Chapter 19 Acids and Bases.
Chemistry Tutorial 1)pH 2)Resistivity 3)Chloride Concentration Measurements 4)Carbonate Concentration Measurements 5)Sulfate Concentration Measurements.
Aqueous Solutions. Soluble and Insoluble Soluble generally means that more than 1 g of solute will dissolve in 100 mL of water at room temperature. Insoluble.
A Seminar on Potentiometric and Diazotization Titrations
Electroanalytical methods
Balancing chemical equations. WRITING CHEMICAL EQUATIONS Chemical equations should show : (a) formulas of the reactants & products (b) their states of.
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
Reactions in Aqueous Solutions 1. Solutions (textbook p ) Aqueous Solution – A solution in which the solvent is water. Water is the solvent (does.
Suggested HW: Ch 12: 1, 10, 15, 21, 53, 67, 81. Aqueous Solutions Much of the chemistry that affects us occurs among substances dissolved in water (proteins,
Chapter 8 Reactions in Aqueous Solution. Will a reaction Occur? Driving Forces in a Chemical Reaction  Formation of a solid  Formation of water  Formation.
Ch. 20 Acids and Bases. Observable Properties of Acids and Bases Sour Taste Electrolytes when in aqueous solution React with metals to produce Hydrogen.
Electrical Conductivity. Questions (copy them out first) Give the definition and an example for the following terms: 1)A solution is__________________?
Solutions Homogeneous mixtures of 2 or more substances Can be: Solid Sterling Silver Gas Air Liquid **Used most frequently in chemistry**
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
Chapter 8 Substances, Mixtures, and Solubility. I. Substances A. Atoms and Elements A substance is matter that has the same fixed composition and properties;
Acid/Base Titration Dr. Hisham Ezzat Abdellatef Prof. of Analytical Chemistry Dr. Hisham Ezzat Abdellatef Prof. of Analytical Chemistry Clinical Pharmacy.
PH THEORY What is it pH?What is it pH?/How is pH Measured?/What Equipment is Required to Measure pH?/How is a pH Measurement Device Calibrated?/Why is.
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 18, 19, 21.
Ch. 21 Potentiometry 1. General principles
PH meter Bushra mubarak. pH pH is defined as the negative logarithm of the hydrogen ion activity aH. Unit of measure which describes the degree of acidity.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Electrochemistry The study of chemical reactions that produce electrical current or are driven to occur by applying an electrical current. Chemical potential.
Applied to Proper Hardware Selection
Electrolysis 3 Electrolysis An electrolysis is the inverse of an electrochemical cell. A non-spontaneous reaction is caused by the passage of an.
Chemistry 141 Monday, October 2, 2017 Lecture 12
Ion Selective Electrode
Applied to Proper Hardware Selection
Tracking Reaction Progress via Electrochemical Methods
Intellical Red-ROD technology
Presentation transcript:

File Name: pH.pptFeb 2001 pH Theory Applied to Proper Hardware Selection

File Name: pH.pptFeb 2001 pH Theory  pH is a Unit of Measurement pH = Power of Hydrogen (H + ) Defined as the Negative Logarithm of Hydrogen Ion Activity pH = log (1/H + )  Used for Determining the Acidity or Alkalinity of an Aqueous Solution Practical pH Scale for Industrial Instrumentation pH

File Name: pH.pptFeb 2001 Acids and Bases  Acid dissolves in water to furnish H + ions HCl H + + Cl - HNO 3 H + + NO 3 - HF H + + F -  Base dissolves in water to furnish OH - ions NaOH Na + + OH - KOHK + + OH - NH 4 OHNH OH -

File Name: pH.pptFeb 2001 Ion Concentration (mol/l)

File Name: pH.pptFeb 2001 Typical pH Values

File Name: pH.pptFeb 2001 pH is a Potentiometric Measurement  The Measuring System consists of a pH Measuring Electrode and Reference Electrode  The Potential Difference Between the Two Electrodes is a Function of the pH Value of the Measured Solution  The Solution Must Be Conductive and is Part of the Electrical Circuit pH Measuring ElectrodeReference Electrode

File Name: pH.pptFeb 2001 pH Sensor Components  pH Measuring Electrode Purpose is to Develop a Millivolt Potential Directly Proportional to the Free Hydrogen Ion Concentration in an Aqueous Solution  Reference Cell Purpose is to Maintain a Constant Reference Potential Regardless of pH Change or Other Ionic Activity in the Solution  Reference Cell Liquid Junction Purpose is to Maintain Electrical Contact Between the Reference Electrode and the Measuring Electrode by way of the Solution Ag/AgCl Element pH Measuring ElectrodeReference Cell pH Sensitive Glass Liquid Junction KCl Gel KCl Buffered to 7 pH

File Name: pH.pptFeb 2001 Process Internal Fill Solution How the pH Sensitive Glass Works  Lithium Ions in the pH sensitive glass act as current carriers  Positive Charged Free Hydrogen Ions (H + )Develop Positive mV Potential Relative to Internal Buffer Acidic Solutions  Fewer Hydrogen Ions Relative to Internal Buffer Produce a Negative mV Potential Alkaline Solutions H+H+ H+H+ H+H+ H+H+ H+H+ H+H+ pH Glass External Gel Layer Internal Gel Layer H+H+ H+H+ H+H+ H+H+ H+H+ H+H+ Li

File Name: pH.pptFeb 2001 pH Temperature Slope  Acids = Positive mV Signal  Base = Negative mV Signal  7.0 pH = 0 mV Output  Sensor Output Changes with Temperature 0 o C ~ 54.2 mV/pH 25 o C ~ 59.2 mV/pH 50 o C ~ 64.1 mV/pH  Sensor Output is Corrected to 25 o C with Automatic Temperature Compensation

File Name: pH.pptFeb 2001 Temperature Error in pH Units

File Name: pH.pptFeb 2001 pH Measuring Electrode  Purpose is to Develop a Millivolt Potential Directly Proportional to the Free Hydrogen Ion Concentration in an Aqueous Solution Process Effects High Temperature Faster Response / Lower Impedance Accelerates Aging, Lithium Ions Leached from Membrane Short Span Low Temperature Slower Response / Higher Impedance Measurement > 10.0 pH Alkaline / Sodium Ion Error Coatings Slower Response Increase Zero Offset < 50% Water Dehydration Steam Sterilization Dehydration Ag/AgCl Dissolves from Silver Reference Element

File Name: pH.pptFeb 2001 OHM’s Law Applied to pH  The pH Measuring Electrode Develops 59.2 mV per pH Unit  pH Membrane Impedance is Approximately 100 Meg 25 o C  Recommendations Shielded Cable is Required to Transmit a Reliable Signal Use Self-Powered Unity Gain Preamplifier Mount the Transmitter 15 feet or Less from Sensor E IR.059 V/pH 100,000,000 Ohms10 -9 Nano Amps

File Name: pH.pptFeb 2001 Temperature Affects pH Electrode Response Time  pH Glass Electrode Impedance is approximately o C  For approximately every 8 o C Step Change from 25 o C the pH Glass Impedance Doubles or Halves  > 25 o C Faster Response  < 25 o C Slower Response >1000 MegOhms pH Generally Becomes Inoperable Recommendations Hold Distance Between Transmitter and Sensor to a Minimum Use Low Temperature pH Membrane

File Name: pH.pptFeb 2001 pH Electrode Life is Temperature Dependent  Typical pH Electrode Life is Months  Life is Reduced Approximately 50% for Every 25 o C Increase in Operating Temperature  Recommendations Sample Cooling Intermittent vs Continuous Measurement

File Name: pH.pptFeb 2001 pH Glass Electrode Options  Continuous Operation > 11.0 pH HPH Option (High Alkaline)  Continuous Operation > 176 o F (80 o C) HT Option (High Temperature)  Continuous Operation < 41 o F (5 o C) LT Option (Low Temperature to -13 o F (-25 o C)  Hydrofluoric Acid HF glass in 1N HCl (0.1pH) Test Protocol (Same Electrodes) 1000 ppm 20 o C for 140 hrs = OK 1000 ppm 50 o C for 100 hrs = OK 10,000 ppm 20 o C for 100 hrs = Fail Total time 340 hours or 14 days

File Name: pH.pptFeb 2001 pH Reference Cell  Purpose is to Maintain a Constant Reference Potential Regardless of pH Change or Other Ionic Activity in the Solution Process Effects Dilution of the Electrolyte Air Entrapment Normal Process Temperature and Pressure Fluctuations Sugar, Organics such as Methylene Chloride, Chlorine Gas Heavy Metal Poisoning from Lead, Mercury, Silver Drift Sulfide (H 2 S) Poisoning Plugs Liquid Junction Loss of Signal High Purity Water < 100 uS/cm Conductivity Flow Sensitivity Low pH Values ( 13.0 pH) Junction Potential Offsets

File Name: pH.pptFeb 2001 Reference Cell Contamination  Silver Reacts with Sulfides Forming a Non-Conductive Precipitant at the Liquid Junction  Result is an Open Electrical Circuit Between the Measuring and Reference  Other Undesirable Reactions that Change the Chemistry of the Reference Half Cell are Caused by: Silver (Ag) Lead (Pb) Mercury (Hg) Copper (Cu) Bromide (Br - ) Iodide (I - ) Cyanide (Cn - )

File Name: pH.pptFeb 2001 pH Control Start, Stop, Slow Down or Speed Up a Chemical Reaction

File Name: pH.pptFeb 2001 Acid Equivalents Chart

File Name: pH.pptFeb 2001 Base Equivalents Chart

File Name: pH.pptFeb 2001 Titration Curve Strong Acid with Strong Base

File Name: pH.pptFeb 2001 Two Position On - Off Control  Measured variable will cycle around control point (7.0 pH)  Guidelines for control Tank Retention Time > 5 minutes Good Chemical Mixing, Tank turnover every two minutes Use alarm dead band and/or delay time on/off to compensate for minor variations in control

File Name: pH.pptFeb 2001 Proportional + Integral (PI) Control  Tank or Vessel retention time < 5 minutes  In-line mixing prior to sensor important  Adjust to achieve 4:1 decay ratio after process upset