MASS ANALYZERS AND IONIZATION METHODS

Slides:



Advertisements
Similar presentations
Mass Spectrometry Chem 3500 Mass Spectrometry Y. Zhao Lecture 2 A Glimpse of Mass Spectrometry Began from 1920s: Aston, Dempster, Thompson MS is often.
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Les détecteurs de masse : une révolution en chromatographie 1ère partie : Introduction à la spectrométrie de masse Pr. Jean-Louis Habib Jiwan UCL – Département.
Sanja Risticevic Chem 323 Poster Presentation Quadrupole Ion Trap Mass Spectrometry.
Andrew Rouff and Ben Berger
Ionization II: Chemical Ionization CU- Boulder CHEM 5181 Mass Spectrometry & Chromatography J. Kimmel Fall 2007.
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chem. 133 – 4/23 Lecture.
Chem. 133 – 4/28 Lecture. Announcements Lab Report 2.3 due Today Pass back graded materials (lab reports 2.2, Q5, and AP3.1) Today’s Lecture Mass Spectrometry.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Mass Spectrometry. How is MS Done? Basic MS Instrumentation.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
Proteomics The proteome is larger than the genome due to alternative splicing and protein modification. As we have said before we need to know All protein-protein.
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Mass spec lecture. What kind of info can mass spec give you? Molecular weight Elemental composition (low MW with high resolution instrument) Structural.
Atomic Mass Spectrometry
Molecular Mass Spectrometry
LC-MS Lecture 7.
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Proteomics Informatics – Overview of Mass spectrometry (Week 2) Ion Source Mass Analyzer Detector mass/charge intensity.
Mass spectrometry-based proteomics Jeff Johnson Feb 19, 2014.
Russell Rouseff FOS 6355 Summer 2005 What is Mass Spectroscopy Analytical Chemistry Technique Used to identify and quantify unknown compounds Can also.
Gas Chromatography And Mass Spectrometry
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
<Instant Notes, D. Kealey & P.J. Haines>
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 22 Mass spectrometry Copyright © 2007 by W. H. Freeman.
Mass Spectrometry I Basic Data Processing. Mass spectrometry A mass spectrometer measures molecular masses. The mass unit is called dalton, which is 1/12.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Based on ionization of gas phase molecule followed by analysis of the masses of the ions produced. The Mass Spectrum: Graph of ion intensity versus mass-to-charge.
Lecture 5b Mass Spectrometry.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
For all CHEM5161 students: The first day of class for CHEM5161 (Analytical Spectroscopy) will be on TUE Sept 4 (following Labor Day). There will be no.
Chemistry 367L/392N Macromolecular Chemistry Lecture 8.
Ionization energy?. Ionization energy? EI Ionization??
Mass Analyzers: Quadrupole ion trap?  
CHM 312 Fall 2008 Special Topics in MS Dr. Ralph Mead.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
Mass Spectrometry Quantitative Mass Spectrometry
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
What is Mass Spectrometry? Mass spectrometry could be considered as an analytical technique that involves the study in the gas phase of ionized molecules.
Introduction to Liquid Phase Mass Spectrometry
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Metabolomics Part 2 Mass Spectrometry
Peptide Mass Finger-Printing Part II. MALDI-TOF
CHEM133 Mass Spectrometry: Lecture 1
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Chem. 133 – 4/13 Lecture.
For Forensic Toxicology use Only
Tandem MS.
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Mass Spectrometry Obaid M. Shaikh.
Metabolomics Part 2 Mass Spectrometry
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Presentation transcript:

MASS ANALYZERS AND IONIZATION METHODS Greg Barrett-wilt, phd UW Mass spectrometry/proteomics facility

Central components of a mass spectrometer Ionization source Mass analyzer/filter Detector Vacuum chamber To perform mass spectrometry two things are required: 1. The analyte must be an ion 2. The analyte must be in the gas phase

Ionization methods

Electron impact ionization (EI) “Hard” ionization method – ionization and fragmentation occur simultaneously Incompatible with liquid streams Widely used with gas chromatography Very standardized method: 70eV electron energy NIST database

Electron impact ionization (EI) http://www.chromacademy.com/essential-guide/nov2010/fig-1.jpg Wiley Registry of 638,000 compounds (>700,000 spectra) NIST Library:  242,477 compounds Fred McLafferty

Chemical ionization (CI) “Softer” ionization method – observation of intact molecular ions possible EI source filled with gas (N2, methane, ammonia) yields ionized gas molecules Reagent gas ions ionize analytes Primary ion formation CH4 + e- → CH4+ + 2e- Secondary reagent ions CH4 + CH4+ → CH5+ + CH3 CH4 + CH3+ → C2H5+ + H2 Product ion formation M + CH5+ → CH4 + [M+H]+ (protonation) [M+H]+

matrix assisted laser desorption ionization (MALDI ) “Soft” ionization method: preserves the intact analyte UV absorbing matrix is energized by the laser Matrix molecules desorbed from the surface carry analyte molecules into the gas phase Proton transfer from matrix (acid) to analyte in the gas phase UV laser used to generate ions: N2 (337 nm) or Nd:YAG (355nm) Yields singly-charged species almost exclusively http://www.magnet.fsu.edu/education/tutorials/tools/ionization_maldi.html Koichi Tanaka: Nobel Prize in Chemistry (2002)

maldi MALDI matrices α-cyano 4 hydroxycinnamic acid (CHCA) dihydroxy benzoic acid (DHB) 3-hydroxy picolinic acid (3-HPA) sinapic acid Analyte samples are co-crystalized with matrix molecules Example from AB Sciex 4800 TOF-TOF spotted with CHCA

MALDI BSA protein standard Couples well to high mass-range instruments (TOF) because high molecular weight biomolecules with a single charge will be observed at high m/z. BSA protein standard [M+H]+ [M+2H]2+ [2M+H]+ [3M+H]+ [4M+H]+ [3M+2H]2+

Electrospray ionization (ESI) “Soft” ionization that yields intact analyte ions with one or more charges A high voltage (kV) is applied to a liquid stream Flow rates can vary between ~50nL/min and 1mL/min These various flow rates require substantially different source parameters John Fenn: Nobel Prize in Chemistry (2002)

Electrospray ionization (ESI) Couples easily to HPLC Analyte molecules can accept multiple charges (protons) Analytes can be present in multiple charge states 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 m/z 100 Relative Abundance 432.899 324.926 648.844 Peptide DRVYIHPFHL (MW=1295.677) +2 +4 +3 +33 +32 +31 Protein MW=31,928 +30 +29 +28

Mass analyzers

Quadrupole 𝑎𝑢= 8𝑒𝑈 𝑚𝑟02Ω2 𝑞𝑢= 4𝑒𝑉 𝑚𝑟02Ω2 (a) (q) U = DC voltage 𝑎𝑢= 8𝑒𝑈 𝑚𝑟02Ω2 𝑞𝑢= 4𝑒𝑉 𝑚𝑟02Ω2 U = DC voltage V = AC voltage r0 = radius Ω = AC frequency (a) (q) Randall Pedder “Practical Quadrupole Theory: Graphical Theory (2010) (Presented as ASMS poster 2001) http://www.nasa.gov/mission_pages/msl/news/sam-tastes-mars.html Ubiquitous mass filters for numerous applications

Quadrupole Implications for proteomics: Mass range: 10 - ~2000 Resolution: “unit” (100 at m/z 100, 1000 at m/z 1000) Sensitivity: moderate-low (scanning instrument) Spectral acquisition rate: moderate (~1s per spectrum) Implications for proteomics: Full MS only, low resolution, slow speed

Tandem mass spectrometer: two stages of mass filtering (MS/MS) Triple-Quadrupole Tandem mass spectrometer: two stages of mass filtering (MS/MS) Collision cell between two quadrupole mass filters: Collision induced dissociation (CID) Additional experiments possible with a triple quadrupole SRM/MRM Domon and Aebersold, Science 312 (2006)

Triple-Quadrupole Agilent 6495 (2014) AB Sciex 6500 (2012) Triple quadrupole instruments are a very active field of mass spec development. Considered the most widely-used type of mass spectrometer. Agilent 6495 (2014) AB Sciex 6500 (2012) Thermo TSQ Quantiva (2013)

Triple-Quadrupole Implications for proteomics: General operating specifications same as single-quadrupole Mass range: 10 - ~2000 Resolution: “unit” (100 at m/z 100, 1000 at m/z 1000) Sensitivity: moderate-low (scanning instrument) Spectral acquisition rate: moderate (~1s per spectrum) BUT in SRM/MRM mode: Mass range: N/A Resolution: “unit” (~1 amu mass window) Sensitivity: very high (fixed mass, no scanning) Acquisition rage: N/A (~10ms per transition) Implications for proteomics: Very high sensitivity in SRM/MRM mode, very linear instrument response, excellent quantitation

3D ion trap 3D ion trap introduced commercially in 1983 Substantial increase in full scan sensitivity because all m/z ions are trapped and detected (as opposed to quadrupole instruments). Very efficient MS/MS, especially for peptides. Can only trap a limited number of ions at one time. 𝑞𝑧= 4𝑒𝑉 𝑚𝑟02Ω2 Wolfgang Paul and Hans Dehmelt: Nobel Prize in Physics (1989) V= ring electrode voltage amplitude Ω= ring electrode RF frequency r0= trap radius

2D ion trap (linear ion trap) “Can only trap a limited number of ions at one time.” 3D ion trap: ~1000 ions in a spherical volume 2D ion trap: ~30,000 ions in a cylindical volume Thermo LTQ: 2D trap replaces a 3D ion trap (single mass filter) OR 2D trap incorporated in a hybrid MS (see below) AB Sciex QTRAP: 2D trap replaces Q3 of a triple quad (tandem mass filters) Implications for proteomics: Low resolution, very good peptide MS/MS

Orbitrap Originally described in 1920 (Kingdon trap) it was only in the late ’90’s that it was developed into a mass spectrometer (Makarov, Anal. Chem. 2000). First new mass filter since the quadrupole ion trap in 1984 Technology owned by ThermoFisher Commercial instrument introduced in 2005 Resolving power = >200,000 http://en.wikipedia.org/wiki/Orbitrap#cite_note-Mak1-1 𝜔𝑧= 𝑘 𝑚/𝑞 m/z analysis property:

LTQ Orbitrap Operation Principle 1. Ions are stored in the Linear Trap 2. …. are axially ejected 3. …. and trapped in the C-trap 4. …. they are squeezed into a small cloud and injected into the Orbitrap 5. …. where they are electrostatically trapped, while rotating around the central electrode and performing axial oscillation The oscillating ions induce an image current into the two outer halves of the orbitrap, which can be detected using a differential amplifier Ions of only one mass generate a sine wave signal

Frequencies and Masses The axial oscillation frequency follows the formula Where w = oscillation frequency k = instrumental constant m/z = …. well, we have seen this before Many ions in the Orbitrap generate a complex signal whose frequencies are determined using a Fourier Transformation

Orbitrap Critical feature of Orbitrap hybrid instrument: Multiple ion traps means that ions can be analyzed simultaneously in the different analyzers. R = 120,000 Significant increase in duty cycle (neither mass analyzer is ever idling) http://www.youtube.com/watch?v=KjUQYuy3msA Implications for proteomics: High resolution/mass accuracy (Orbitrap), very good peptide MS/MS (ion trap), very high duty cycle (hybrid), fast scan speed

Orbitrap XL: LC/MSn ~1000 proteins in 4 hours 40 60 80 100 120 140 160 180 200 220 240 260 280 Time (min) 10 20 30 50 70 90 Relative Abundance ~1000 proteins in 4 hours

Several instrument types Orbitrap Elite (2010) Q Exactive (~2008) LTQ Orbitrap XL (~2007) Orbitrap Fusion (2013)

Time-of-flight (TOF) 𝑡=𝑘 𝑚 𝑞 𝑡=𝑘 𝑚 𝑞 Where k incorporates accelerating voltage and distance of flight tube

Time-of-flight: esi

Time-of-flight: maldi AB Sciex 4800 MALDI TOF-TOF: MS and MS/MS

Q-tof (or Qq-TOF) Similar to triple-quad MS, but the third quad is a TOF High resolution, accurate mass MS/MS is performed after MS survey scan (in series) by increasing the offset energy in the collision cell High-resolution MS1 and MS/MS Assist in database searching of proteomic data, unknown i.d.

Ion mobility MS Agilent 6560 Adds a drift tube in the flight path of the ions prior to the TOF region This allows for separation of species based on their gas-phase cross-section: Small ions are retarded by gas molecules less than large ions (even for same m/z) Waters

TOF features MALDI TOF: Decoupled from HPLC: fast (~1 sec/spectrum) MS/MS capable (TOF/TOF): ideal for rapid protein ID from 1D gel band Resolution > 20,000 Laser rate 1kHz-2kHz (new instruments) ESI-TOF: Resolution >40,000 Fast electronics give excellent sampling across chromatographic peaks Q-TOF: High resolution MS1 and MS/MS Ion Mobility Q-TOF: Additional structural information from cross-section (separate isobarics) Non-covalent interaction experiments Implications for proteomics: High resolution/accurate mass for MS and MS/MS, fast scan speed, wide mass range (100,000 MS1, 4000 MS/MS)

Wrap-up Ionization sources: EI CI MALDI ESI Mass Analyzers: Single and triple quadrupole 3D and 2D ion trap Orbitrap Time-of-flight (TOF/TOF) Q-TOF Ion mobility Others: APCI APPI ICP SIMS Others: Magnetic sector Isotope ratio FT-ICR Accelerator