Laboratory Ventilation. 2 Types of Laboratory Hoods  Constant Volume  Conventional  By-Pass  Auxiliary-Air  Reduced Air Volume  Variable Volume.

Slides:



Advertisements
Similar presentations
Bloodborne Pathogens Biological Safety Training Prepared by: Atef El-Gendy, PhD.
Advertisements

Biological Hazards Routes of Entry
PowerPoint ® Presentation Chapter 14 Homeland Security Homeland Security Building Layout Specific CBR Attack Prevention Recommendations Securing Outdoor-
ASEPTIC TECHNIQUE. PERSONAL PROTECTIVE EQUIPMENT includes: Eye protection Gloves Masks Gowns Sterile technique is employed to prevent contamination of.
Containment Equipment and Facilities. Biocontainment The principle of holding or being capable of holding or including within a fixed limit or area The.
Working Safely In Your Biological Safety Cabinet
Tulane University - Office of Environmental Health & Safety (OEHS) LABORATORY VENTILATION FOR TULANE LABORATORY EMPLOYEES January, 2005.
L ABORATORY SAFETY CABINET Dr Fadhl Alakwa
Chemical Fume hood or Biosafety Cabinet
Aishah Hazlina Md.Dean Jurutera Mekanikal
Airflow and BSC Biosafety and Biosecurity Awareness Training
Fume Hoods. Objectives Overview of fume hoods Types of fume hoods Fume hood design definitions Fume hood operating performance and testing Sound work.
NFPA 96 and Building Code Requirements for Commercial Kitchen Hood Systems Presentation for the Sevier County Fire Code and Building Code Officials Presented.
Lehman College Environmental Health & Safety November 2011.
+ Chemical Spill Response in the Lab. + Chemical Spills Spills can seriously disrupt laboratory operations. If handled properly, a spill may be nothing.
Patentes Steril-Aire 5,334,347 Electric Discharge Device Aspects of the present invention are found in an electric discharge device comprising an envelope.
Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.
Break Out Session 3: Group A: Ventilation and Air Quality Chris Cosgrove, Cosgrove FDS, Inc.
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE
Providing services that help make The University of Memphis a safe and healthful place to learn and work Environmental Health and Safety.
Laboratory Safety-Fume Hoods 29 CFR Laboratory Safety Standard.
ONLINE SELF-STUDY Chemical Fume Hoods. References:  Prudent Practices in the Laboratory – 2011 (National Research Council of The National Academies):
Siemens Building Technologies, Inc. ED&G 100 Design Project Fume Hood Face Velocity Control Spring 2004.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
Types of Laboratory Hoods and Specific Uses. Horizontal Laminar Flow Cabinets SHC-A AHC-A.
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
1 FUME HOOD SAFETY Environmental Energy Technologies Division Safety Topic July 12, 2012.
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
Lab Inspections State Fire Marshal’s Office. Applicable Codes 1999 BOCA Business Occupancy 1999 BOCA Fire Prevention Code 2000 NFPA 101, Life Safety Code.
1 CHEMICAL SAFETY LEVELS FOR SCHOOL LABORATORIES A SYSTEM FOR IDENTIFYING RISKS UPON ENTERING A LAB.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
Environmental Health and Safety
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
Local Exhaust Ventilation
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
LABORATORY VENTILATION
Saving Ventilation Dollars A Look at Economics of Ventilation.
Unit 6.4. Filtration TB Infection Control Training for Managers at National and Subnational Level.
Eliminating and Controlling Dust & Noise Hazards July 2002.
MLAB 2434 – CLINICAL MICROBIOLOGY SUMMER, 2005 CECILE SANDERS & KERI BROPHY Chapter 2 – Control of Microorganisms.
Potential Terrorist Hazards. Biological Bacteria Viruses Toxins Delivery methods: Aerosols Animals Food and water Person-to- person.
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Sterile Products Lab PHT 434
Bio-safety Cabinet Dr Fadhl M Alakwaa. Agenda What is bio safety cabinet (BSC)? BSC risks BSC Components. What is bio safety levels? Types of bio safety.
Copyright © 2010 John Wiley & Sons, Inc. Figure Degrees of Eye Protection from Simulated Splashes Using Varied Types of Eye Protection. The mannequin.
Lab design Assignment 3 Unit 2.
Introduction to Energy Management. Week/Lesson 8 Air Cleaning Equipment.
Austin Pure Air Independent Agent - Products and Prices 2016 UNRIVALED PURIFICATION TO 1 NANO EVEN IN OUR SMALLEST UNIT Quiet Operation The GENANO 200.
Containment Equipment and NSF 49. Containment – BMBL Primary containment is the protection of personnel and the immediate lab environment from exposure.
Exhaust Ventilation Level 4: Special considerations with very hazardous substances Part 2 of 2.
Working safely with Biological materials Aseptic technique, sterilization and tissue culture techniques.
Hierarchy of Hazard Control
Prevention and Control of Influenza A (H1N1) in the Workplace Engr. Nelia G. Granadillos Chief, Environment Control Division Occupational Safety and Health.
ASEPTIC TECHNIQUE.  Laboratory practices that minimize the risk of cultured cells becoming contaminated with unwanted microorganisms.
3 MANAJEMEN FASILITAS DAN KESELAMATAN ( SAFETY )
Industrial Ventilation
FUME HOODS Welcome to an on-line
NAFA Guide To Air Filtration
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE
(Modified from University Of South Carolina)
Biosafety Cabinet (BSC): What you need to know?
Compounding.
Ultimate Clean Digestion Cups and Clean Lab Testing
Fume Hood – Proper Handling of Chemicals / Proper Functioning
Laboratory Ventilation
ZEBALABS FUME CONTAINMENT Zebalabs is there to ensure best quality fume containment that is well capable to eliminate all kinds.
Presentation transcript:

Laboratory Ventilation

2 Types of Laboratory Hoods  Constant Volume  Conventional  By-Pass  Auxiliary-Air  Reduced Air Volume  Variable Volume  Special Application  Perchloric Acid  Radioisotope  Distillation and Walk-In

Laboratory Ventilation3 Constant Volume Hoods Conventional Hoods: This is a basic enclosure with an interior baffle and movable front sash. Closing the sash increases the face velocity of the air through the sash opening. By-Pass Hoods: These are designed with by-pass openings above and below the sash that allow a constant face velocity when the sash is closed. By- pass hoods comprise the majority of hoods on the market today.

Laboratory Ventilation4 Constant Volume Hoods (Contd.) Auxiliary-Air Hoods (AKA: Induced-air, Balanced-air, Make-up air). This is a variation of the By-pass hood which can provide up to 50% of the exhaust air from the outdoors through a separate intake. Reduced Air Volume Hoods: Another variation of the By-pass hood, this enclosure uses a by-pass block to partially obstruct the by-pass opening above the sash. This results in less air volume than other same-sized hoods, which means they can use smaller blowers.

Laboratory Ventilation5 Variable Volume Hoods Variable volume hoods vary the amount of room air exhausted while maintaining the required face velocity using two methods. The methods are:  utilizing a movable damper that opens and closed based on airflow and sash position.  varying blower speed to meet air volume demands.

Laboratory Ventilation6 Special Application Hoods Perchloric Acid Hoods: These hoods are dedicated for use with perchloric acid only, due to the possibility of an explosion if contact with organic matter occurs. Can be made of SS 316, Type-I PVC, or ceramic-coated material. A washdown system is required to prevent the accumulation of highly reactive perchloric salts. Radioisotope Hoods: Liner materials, such as SS 304 or lead, need to be impervious to radioactive particles. These hoods should have HEPA or charcoal filters incorporated in the ductwork to trap radioactive particles in the exhaust air. Distillation and Walk-In Hoods: These hoods are designed to accommodate large lab equipment that can be permanently installed in the hood or mounted on wheels to allow it to be rolled in the hood for use.

Laboratory Ventilation7 Other Laboratory Enclosures  Canopy Hoods  designed to remove steam, heat or odors from bulky apparatus such as ovens or steam baths. Not for hazardous substances.  Downdraft Hoods  blower mounted below the work area. Used for gases with a greater density than air and particulates.  Biological Safety Cabinets  designed to contain viruses and other microbes. Used with HEPA filters to trap particles.

Laboratory Ventilation8 Other Laboratory Enclosures (Contd.)  Clean Benches  force room air through a HEPA filter and over a work surface. Designed for product protection only.  Glove Boxes  provide a physical barrier from contaminant.

Laboratory Ventilation9 Hood Comparison Chart