Finger Plethysmograph

Slides:



Advertisements
Similar presentations
EE 4BD4 Lecture 26 Plethysmography 1. Definition Measure volume change over time Flow = dvolume/dt 2.
Advertisements

Chapter 1. Basic Concepts of Medical Instrumentation Walter H. Olson
Chapter 3. Amplifiers and Signal Processing John G. Webster
ELECTROCARDIOGRAM (ECG)
myDAQ Biomedical Instrumentation Board
Alex Bode Emmanuel Cordova Mikel Dualos Christa Hamilton Medical Instrumentation Spring 2011.
Chapter 5 Part Three Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
Data Acquisition for Biofeedback System Using LabVIEW Midterm Presentation Performed by Rapoport Alexandra Supervised by Eugene Rivkin Technion Department.
Chapter 3. Amplifiers and Signal Processing John G. Webster
Electrochemical Glucometers
P13071 – Non-Invasive Blood Glucose Monitor Team Members Jared Bold Yongjie Cao John Louma Andrew Rosen Dan Sinkiewicz Faculty Advisor Professor George.
GROUP 2: Martha Ingram, Megan Johnston, Chelsea Samson MENTORS: Dr. Michael Holzman, Dr. William Beck, Dr. Benjamin Poulose AN OPENING IN THE ABDOMEN,
TEAM MEMBERS Dan Carlson Team Leader Dave Ugai Communicator Erik Bieging BWIG/BSAC.
© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 8.1 Several methods of.
Esophageal Strictures William Stanford – Leader & BSAC Daniel Frost – BWIG Thomas Fleming – Communicator Client: Dr. Mark Reichelderfer, MD Advisor: Professor.
1 Wireless power for mobile phones - System overview Nov 25, 2012 V1.1.
Figure 13.1 Block diagram of an asynchronous cardiac pacemaker
Skin Color Monitor Sarah Offutt, Rachel Mosher, Victoria Vasys BME 301 March 7, 2008.
EMG Biofeedback Device BME 200/300 Fall 2003 Department of Biomedical Engineering University of Wisconsin-Madison.
1Abstract Our objective was to design an infusion pump that will be used to deliver contrast agents during a MRI exam. Currently used is a syringe pump.
Team Members: Joe Bothwell Communicator Kelly ToyTeam Leader Jon Cappel BWIG Karim Mahamud BSAC.
Presentation for ENSC 440/305 Instructors: Patrick Leung, Steve Whitmore Department of Engineering Science Simon Fraser University.
MRI INFUSION PUMP Group Members: Aman Ghotra – Team Leader
RITRIT Biomedical Engineering Department of Chemical and Biomedical Engineering Kate Gleason College of Engineering Rochester Institute of Technology.
SYDE 292 Circuits, Instrumentation and Measurement Instructor: Prof. Dan Stashuk DC 2613 Ext Objectives: Based on E & M.
Biofeedback and Stress Management BME 402 Spring 2004.
TEAM MEMBERS: STAN WEED (TEAM LEADER), PAVEL KUZNETSOV, ERIC-THOMAS ARROYO PROJECT ADVISORS: DR. JOHN R. LACOURSE, PROF. FRANCIS C. HLUDIK Wireless Activity.
ASHOR CHIRACKAL MICHELLE TAN IMRAN BUTT LUKE LEHMAN CLIENT: MR. JOSH UNDERWOOD, ASC ADVISOR: DR. TIM BIGELOW ISU SODAR Team sddec
Non-Invasive Blood Pressure Waveform Monitoring in Mice By Andrew McClellan Laura Miller.
School of Biomedical Engineering, Science & Health Systems V 2.0 SD [020204] Impedance Cardiography for Non-invasive.
Team: Charlie Haggart, Gabriel J. Martínez-Díaz,
Aga Khan University Hospital Karachi
Tactile Auditory Sensory Substitution Ryan Thome, Sarah Offutt, Laura Bagley, Amy Weaver, Jack Page BME 200/300 December 8, 2006.
Device for the Presentation of Olfactory Stimuli to Monkeys Team Members Kevin Campbell (BWIG) Sarah Kolpin (Communications) Wyatt Potter (Team Leader)
IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 50, NO. 3, MARCH 2015 Woojae Lee, Member, IEEE, and SeongHwan Cho, Senior Member, IEEE Chairman: Dr.Shih-Chung.
Perceptible output Output display Control And feedback Signal
Device for the Presentation of Olfactory Stimuli to Monkeys Team Members Kevin Campbell (BWIG) Sarah Kolpin (Communications) Wyatt Potter (Team Leader)
EMG Biofeedback Device BME 200/300 Fall 2003 Department of Biomedical Engineering University of Wisconsin-Madison.
Portable Real Time ECG Design
16-Channel Brain Tissue Stimulator Friday, October 27, 2006.
To develop a secure attachment for data logger and tri-axial accelerometer Replication of a tri-axial accelerometer with the ability to: -Interface with.
© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 3.1 Op-amp equivalent circuit.
Tested liquid flow rate: Aspirator was run for 20 second intervals Recorded collected volume Flow rate was calculated as liters/minute Averages were computed.
Tested liquid flow rate: Aspirator was run for 30 second intervals Liquid Recorded collected volume Flow rate was calculated as liters/minute Air Connected.
Quad Rat Vitals Monitor Team: Jack Ho Kuya Takami Nathan Werbeckes Joseph Yuen Client: Dr. Alex Converse Advisor: Dr. Tom Yen.
Gas Flow Meter Client: John Webster Advisor: Naomi Chesler Project Leader: Anna Moeller Communications: Kailey Feyereisen BSAC: Ryan Drake BWIG: Gina Stuessy.
Gas Pressure Meter (Engineering World Health) Advisor: Prof. Ken Gentry Client: Prof. John Webster, Engineering World Health Engineering World Health Team.
Biofeedback and Stress Management John Harrison – Leader Albert Kwansa – Communicator Eric Lee – BSAC Brenton Nelson – BWIG Dr. Daniel Muller – Client.
ΜPET/CT Heating Device Team Leader – Eric Printz Communicator – Justin Schmidt BWIG – Ryan Carroll BSAC – Ben Engel Client – Dr. Robert Jeraj Ph.D Advisor.
Gas Pressure Meter (Engineering World Health) Advisor: Professor Naomi Chesler Client: EWH and Professor John Webster Team Members: Ksenija Bujanovic-
Skin Color Monitor Client: John G. Webster, Ph.D. Advisor: William L. Murphy, Ph.D. Team Hotflash Jack Ho – Team Leader Joseph Yuen – BWIG Brian Ginter.
Gas Pressure Meter Advisor: Naomi Chesler Client: EWH Team Members Ksenija Bujanovic – Team Leader Claire Edlebeck – Communicator Mike Oldenburg – BWIG.
Finger Plethysmograph
ICP Monitor Client Josh Medow Advisor Willis Tompkins Team Members Lacey Halfen - BSAC Jess Hause – Leader Erin Main – Communicator Peter Strohm - BWIG.
Abstract Final Design Quad Rat Vitals Monitor Jack Ho, Joseph Yuen, Nathan Werbeckes Advisor: Thomas Yen, PhD. Client: Alex Converse, PhD. Design Criteria.
Device to Augment Movements in Stroke Patients
Endotracheal Tube Cuff
Engineering World Health: Aspirator
Testing System for Pressure Sensitive Cardiovascular Catheter
Intracranial Pressure Monitor
Engineering World Health: Aspirator
Padraic Casserly, Andrew Dias, Joey Labuz, Joel Webb
Laparoscopic Banding Instrument
Physiologic signals Lecture 5.
Computer Input Device for Individual with MD
Hyonyoung Han, Min-Joon Kim, and Jung Kim
Instrumented Hand Exerciser
Motorized Wheelchair Mount
IMPEDANCE PLETHYSMOGRAPHY
Noise I Abigail Firme.
Presentation transcript:

Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum- Communications Nick Harrison- BSAC Tyler Lark- BWIG

Outline Background Problem Statement Theory Design Components Electrical Biological Concepts Design Components Circuit Design Mechanical Future Work

Diabetes Body’s inability to manage glucose levels Prevalence is on the rise 26.3 million in U.S. $116 billion excess medical expenditures annually No reliable non-invasive monitoring Hypothesized that blood sugar levels may be correlated with blood resistivity What is diabetes? Marked by irregular blood glucose levels, this is caused by either the pancreas’s inability to produce enough insulin, or the inability to effectively use insulin produced 13.5% increase in last 3 years 26.3 million in US (8% of total US population) Worldwide: 171 million individuals living with diabetes Overall economic burden much higher

Problem Statement Design a finger plethysmograph to measure blood resistivity Goals: Build a mechanical device to secure finger Design a circuit that allows data acquisition of blood impedance

Electrical Theory Four electrode impedance plethysmography 2 electrodes pass current through finger 2 electrodes measure voltage Signal processing Calculate impedance and resistivity from voltage output

Biological Theory High blood flow Low blood flow RBCs align, current meets little resistance Low blood flow RBCs misalign, greater resistance Impedance (ΔZ) results from this Change in volume of artery Saline solution cancels signal High Flow Low Flow

Design Specifications Circuit Sensitivity Adaptable measurement range (i.e. autoreset) Digital filtering and signal processing Mechanical Device Motion artifacts Minimal electrical signature

Circuitry Measuring change in blood resistivity Sample and Hold Filtering Current amplitude and frequency Data interpretation Webster J. G., 1998

Mechanical Design Restrain Finger Circulation Conductive Voltmeter Current Source

Restrain Designs Inflatable Cuff Bar Cage Mesh Cage Top Air in Side

Future Work Build prototype Optimize saline solution Current amplitude and frequency Circuit component values Testing Clinical Trials

References Webster J. G., 1998. Measurement of flow and volume of blood Medical Instrumentation: Application and Design, 3rd Edition ed J G Webster (New York: John Wiley & Sons). Rosenthal, J. H., An inductive plethysmograph for ambulatory ventilation measurement. American Diabetes Association: http://www.diabetes.org/diabetes-statistics.jsp World Health Organization: http://www.who.int/dietphysicalactivity/publications/facts/diabetes/en/

Questions??