Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.

Slides:



Advertisements
Similar presentations
Ge 116 Module 1: Scanning Electron Microscopy
Advertisements

BY Assistant Professor Dr. Akram R. Jabur Department of Materials Eng. University Of Technology.
Electron-Specimen Interactions
Scanning Electron Microscope (SEM)
Effect of Accelerating Voltage on Resolution
Hong Koh Yiin -CAMTEC Image from:
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
X-ray radiography Seminar The "geometrical" unsharpness of X-ray images is limited by finite dimension of the source, i.e. the window on.
Electron-Specimen Interactions
Lecture 5.1 Scanning Electron Microscopy (SEM)
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Scanning Electron Microscope د. عمر عبد القادر.
GAMMA RAY SPECTROSCOPY
Main detector types Scintillation Detector Spectrum.
Surface Emissions Specimen current X-rays Cathodoluminescence Pole Piece, etc SE3  ≈ 1 nm for metals up to 10 nm for insulators.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
Introduction to scanning electron microscopy
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
Photomultiplier Tube. What is it? Extremely sensitive detector of light in the ultraviolet, visible and near infrared Multiplies the signal produced by.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Photon detection Visible or near-visible wavelengths
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
EDS Energy Dispersive Spectroscopy
LIGHT.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
SCINTILLATION COUNTER. PRINCIPLE When light radiations strike fluorescent material it produces flashes of light called scintillations. These are detected.
Scanning Electron Microscope (SEM)
Scanning Electron Microscope (SEM)
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
CAMTECH 2011 Regi. High energy e - beam scans sample surface (Raster - line by line). Provides information about surface and near-surface atoms – topography.
NANO 230 Micro/Nano Characterization
Scanning capacitance microscopy
MINERvA Main INjector ExpeRiment for -A is the symbol for the neutrino. The beam that is sent to MINERvA is made out of neutrinos. In chemistry, an A stands.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
08/03/09 SEM signal generation
SEM Scanning Electron Microscope
Laser physics and its application Introductory Concept The word LASER is an acronym for Light Amplification by Stimulated Emission of Radiation Lasers,
 Display Devices Display Devices  Display Hardware  Components of CRT Components of CRT  Refresh CRT Refresh CRT  Electron Gun  Focussing system.
X-ray SNR in 3 steps. I ∆I. X-ray transmission SNR Review Let N = average number of transmitted x-rays N = N 0 exp [ - ∫  dz ] Emission and transmission.
Chapter V Radiation Detectors.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Electrons Thermionic Emission
SARDAR PATEL INSTITUTE OF TECHNOLOGY E.NO : Guide By:- V.N.Thakkar.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
(Chapter 7) CHEM–E5225 Electron microscopy
Introduction to scanning electron microscopy
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Introduction to scanning electron microscopy
Fabio, Francesco, Francesco and Nicola INFN and University Bari
2.4.2 interaction of x-rays with matter
Laboratory equipment Lecture (3).
NANO 230 Micro/NanoFabrication
TEM and SEM.
By Dominique Baker & Moyna John
Fluoroscopic Unit Thomas Edison 1896.
Scintillation Counter
Circuit Modeling of Dynamic Secondary Electron Contrasts in an SEM
Resident Physics Lectures
When this happens... We see this... 12/6/2018 Steve Wotton.
Do it with electrons !.
The Hall C Heavy Gas Cerenkov
Oct 10, 2018 Muhammad Qasim Abdul Wali Khan University, Department of Physics, Mardan, Pakistan by.
Electrons Thermionic Emission
Electronics and Instrumentation Vidnyan Mahavidyalaya, Sangola.
Photomultiplier (PMT) Tubes
Presentation transcript:

Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results in the SEM image. SEM basics:

Introduction Secondary electron secondary electron detector

Secondary electrons: Secondary electrons are generated from the collision between the incoming electrons and the loosely bonded outer electrons The scattered secondary electrons are categorized into three different types.

Introduction Secondary electron secondary electron detector (1)Electrons with energies E <50 e V: Secondary electrons (SE); (2) Electrons with energies 50 eV < E < E PE : Inelastically backscattered and elastically reflected electrons (RE).

Introduction Secondary electron secondary electron detector SE1: First kind of secondary electrons are generated by the incoming electron beam as they enter the surface. The resulted image has high resolution which is only limited by the electron beam diameter. As SE1 is generated by near surface atoms so this kind of secondary electron is independent of V. acc

Introduction Secondary electron secondary electron detector SE 2: The secondary electrons that are generated by the backscattered electrons have returned to the surface after several inelastic scattering events SE2 come from a surface area which is bigger than the spot of the incoming electrons, also bigger than surface area of SE1. Therefore resolution is less than resolution of SE1 exclusively.

Introduction Secondary electron secondary electron detector SE3: The generator of this kind is the SE2 that enters the lens surface and get scattered. Thus, it will result in a decrease of resolution.

Introduction Secondary electron secondary electron detector Factors that affect Secondary Electron emission: 1- Atomic number (Z) More SE2 are created with increasing Z

Introduction Secondary electron secondary electron detector 2- Beam energy and beam current Electron yield goes through a maximum at low acc. voltage, then decreases with increasing acc. voltage

Introduction Secondary electron secondary electron detector 3- The most important factor is the local curvature of the surface. If we have a edge more secondary electron can be emitted from specific spot.

Introduction Secondary electron secondary electron detector 156 electrons! Image Detector 288 electrons! How do we get an image?!

Introduction Secondary electron secondary electron detector Secondary electrons (SE) are attracted to Faraday cage because of its positive charge. Detector surface inside faraday cage (+12kV) accelerates electrons. Scintillator layer gives off photons when struck by electrons. Light travels down the light tube (LG) and hits photocathode and converted back to electrons. Everhart-Thornley Detector

Introduction Secondary electron secondary electron detector Photomultiplier Tube: – It’s Entrance is coated with photocathode which has low work function, absorbs photons from scintillator and emits low-E photoelectrons. – SE repeatedly accelerated towards N successive dynodes biased at ~+100 V positive with respect to the last, producing more excess SE. (total increase can be as high as 10 6 ).

Introduction Secondary electron secondary electron detector This amplification or gain, is controlled by the contrast control on the SEM. An increase in contrast is seen as a selective increase in the highlights of the image, rather then the shadows. The brightness of the image is controlled by the preamplifier or brightness control. In this case, both highlights and shadow areas of the image are amplified by the same amount.

Introduction Secondary electron secondary electron detector Signal to noise ratio: Signal-to-noise ratio is defined as the power ratio between a signal and the background noise: Therefore, it would be a good way to measure image quality.

Introduction Secondary electron secondary electron detector Factors that affect quality of image: 1.backscattered electrons that have low energy cannot escape Faraday electric field and their absorption will generate a noise signal in our output. 2. Electrical circuitries such as amplifier that are used in our detector produce noise that affects our output. 3. In the diagram, as the beam scans from left to right, areas marked (B) will be bright because they are scanned by the beam and in the line of sight of the detector. Areas marked (I) are intermediate in brightness because they are out of the line of sight of the detector.

Introduction Secondary electron secondary electron detector Regions D will be dark because they are not scanned with the beam at all. Tilting the specimen will alter the specimen topography relative to the beam and detector and may enhance or reduce image quality.