Measurement of Light Transmission in Radiation Damaged Glued Quartz Bars for Q weak KATIE KINSLEY (Department of Physics, Ohio University, Athens, OH 45701)

Slides:



Advertisements
Similar presentations
24.6 Diffraction Huygen’s principle requires that the waves spread out after they pass through slits This spreading out of light from its initial line.
Advertisements

Beam Energy Measurements with Elastic Scattering At Jefferson Lab an electron beam is used to probe the nucleus. In these experiments it is essential to.
Measuring the Speed of Light Jack Young Rich Breazeale Ryan Phelan.
FARADAY ROTATION Gennady Voronov In this experiments we experimentally determine the Verdet constant of a glass rod with specification SF-59 to be rad/mT*cm.
LIGHT. The spectrum consists of all wavelengths of electromagnetic energy. Visible light is only a small portion of this spectrum. The range of visible.
Measuring the Speed of Light! Photonic partners: David Orenstein Anuta Bezryadina Nathan Burd.
A Muon Veto for the Ultra Cold Neutron Asymmetry Experiment Vince Bagnulo with Dr. Jeff Martin Electrons Ultra Cold Neutrons Cosmic Ray Muons Protons Pions.
Mechanical check of PMT Check base: Remove black tape and two small screws that secure the base. Tighten the nuts on the BNC connector for the HT input.
Reverse Engineering Project The Smoke Detector
The Effect of Temperature on the Dark Rate of the Silicon Photomultiplier By Jie Zhao Mentor: Dr. Richard Jones.
Exploiting the Proton’s Weakness L. Cobus, A. Micherdzinska, J. Pan, P.Wang, and J.W. Martin The Standard Model of Physics New Physics??IntroductionFocal.
Study of optical properties of aerogel
Circadian Rhythms / Biological Luminescence Detection Eitan Novotny Sean Dang Philip Tran Yu Kun Zhang.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
STUDY OF AMPLIFICATION ON ERBIUM DOPED FIBER AMPLIFIER Lita Rahmasari, Assoc. Prof. Dr. Yusof Munajat, Prof. Dr. Rosly Abdul Rahman Optoelectronics Laboratory,
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
Jimmy McCarthy International Cosmic Ray Day 26 th September 2012 Detecting Cosmic Rays.
Building a Photodetector to Observe the Polarization of Light Kevin J. McElwee Bridgewater State University, Bridgewater MA Mentor: Edward F. Deveney.
Lesson 5 Conditioning the x-ray beam
Radioactivity Chapter 21  Natural occurring phenomena.  In the nucleus of an atom there are protons and neutrons. Protons are positively charged so they.
Chapter 9 Electromagnetic Waves. 9.2 ELECTROMAGNETIC WAVES.
Generators To explain how a generator works to produce electric current. To explain the difference between alternating and direct current.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
Lecture 3 Need for new theory Stern-Gerlach Experiments Some doubts Analogy with mathematics of light Feynman’s double slit thought experiment.
Dominik Wermus (Virginia Military Institute, Lexington, VA 24450), Doug Higinbotham (Thomas Jefferson National Accelerator Facility, Newport News, VA,
Scintillators, DAQ boards, and PMTs Getting Familiarized With the Equipment By Melissa Sussmann and Alex Bonnifield.
Cosmic Rays: Ever Present and Useful Anthony Gillespie Denbigh High School Mentor: Dr. Douglas Higinbotham Cosmic Rays Using the Cosmic Rays Current Research.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
Contributed by: Integrated Teaching and Learning Program, College of Engineering, University of Colorado at Boulder.
Tracker QA Paul Kyberd Quality Assurance A status report: A procedure for ensuring the quality of the finished tracker has been designed following our.
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
Radius To use a Compton polarimeter, the possible range of the backscattered photons’ energy should be calculated. Applying the laws of conservation of.
Atomic Structure HL and SL 2.1 The Atom Atoms were thought to be uniform spheres like snooker balls. Experiments, however, have shown that atoms consist.
Second Harmonic (SH) Radiation from Twined ZnO Single Nanorods (NR) in Transmission Geometry. Presented by: Aaron Ricca Dr. S. W. Liu.
Neutron Beam Intensity for the Spallation Neutron Source Beamline 13: The NPDGamma Experiment Analysis and Results Jeremy Stewart University of Tennessee.
To measure the beam intensity a sampling method was used where two cadmium apertures (P1 and P2) are placed to cut the beam down so the neutron counts/sec.
LIGHT and MATTER Chapters 12 and 13. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
CEBAF The Continuous Electron Beam Accelerating Facility(CEBAF) is the central particle accelerator at JLab. CEBAF is capable of producing electron beams.
MINERvA Main INjector ExpeRiment for -A is the symbol for the neutrino. The beam that is sent to MINERvA is made out of neutrinos. In chemistry, an A stands.
CEBAF The Continuous Electron Beam Accelerating Facility (CEBAF) at JLab in Newport News, Virginia, is used to study the properties of quark matter. CEBAF.
Fiducial Cuts for the CLAS E5 Data Set K. Greenholt (G.P. Gilfoyle) Department of Physics University of Richmond, Virginia Goal: To generate electron fiducial.
Dual Target Design for CLAS12 Omair Alam and Gerard Gilfoyle Department of Physics, University of Richmond Introduction One of the fundamental goals of.
LIGHT and MATTER Chapters 11 & 12. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
Momentum Corrections for E5 Data Set R. Burrell, G.P. Gilfoyle University of Richmond, Physics Department CEBAF The Continuous Electron Beam Accelerating.
The Babar Cherenkov Detector Detection of Internally Reflected Cherenkov Yuen-Jung Chang.
Young’s Double-Slit Experiment Pg Interference  We now know that the experiments failed for two simple but important reasons:  1. Atoms.
23.1 Atomic structure The Rutherford scattering experiment  In 1911, Ernest Rutherford carried out the famous Rutherford scattering experiment to explore.
Lab Report & Rubric Exercise. Title Title is descriptive and appropriate for the study conducted Interpret and analyze scientific information.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy The Department.
Fiducial Cuts for the CLAS E5 Data Set K. Greenholt (G.P. Gilfoyle) Department of Physics University of Richmond, Virginia INTRODUCTION The purpose of.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
Simple Double Beam Spectrometer
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Beer-Lambert law Gihan Gawish.Dr.
X-Radiation.
Particle Physics LECTURE 7
Toy Monte Carlo for the Chromatic Correction in the Focusing DIRC Data
Required Practical Revision
The Life and Times of Cosmic-ray Muons
Momentum Corrections for E5 Data Set
Measuring the Speed of Light!
The Hall C Heavy Gas Cerenkov
CLAS Simulations for the E5 Data Set
Austin Park and Willie Dong
Presentation transcript:

Measurement of Light Transmission in Radiation Damaged Glued Quartz Bars for Q weak KATIE KINSLEY (Department of Physics, Ohio University, Athens, OH 45701) DAVID MACK (Jefferson Lab, Newport News, VA 23606), JULIE ROCHE (Ohio University, Athens, OH 45701) SYSTEMATIC ERROR The transmission, especially at low frequencies, is well over 100%, which is impossible. Because of this graph: We realized that this was because of a light leak in our dark box, which was being analyzed by the PMT. We used a piece of tape to cover different slit sizes, and also added a collimator to block room light from reaching the PMT. With this change to the hardware, we measured the size of the light leak and found that is was 0.2 nA of room light leaking in. Our new equation accounts for this error: ABSTRACT Electron accelerators all over the world are used to study particles at a subatomic level. In the Q weak experiment, scientists are attempting to learn more about scattering probability for polarized electrons with opposite spin. Detectors are being used in Q weak to measure Cherenkov light. These detectors are extremely large, and in order to build them quartz bars must be glued together using SES406. These quartz bars and glue will be exposed to very high levels of radiation, and it is essential to be sure that the glue will remain transparent, even after high doses of radiation. Using a monochrometer and a PMT, we took measurements with control and experimental quartz bar samples which had been exposed to 1 Mrad of radiation. The final result showed that the SES406 absorbed <1% of the light after being damaged from radiation. INTRODUCTION The key objective of Q weak is to compare the probability of scattering between polarized electrons spinning in opposite directions. In order to do this we take a continuous beam of electrons and shoot it at a hydrogen target. In doing this, the electrons will sometimes come close to the electrically charged parts of the target, causing the beam of polarized electrons to scatter at different angles. We used Cherenkov light detectors consisting of large quartz bars and photomultiplier tubes. These detectors are quite large, therefore several large quartz bars must be glued together using Shin-Etsu Silicones 406. However, the continuous electron beam emits powerful amounts of radiation, and the transparency of the glue could be compromised due to radiation damage. The ability of the glue to withstand high levels of radiation needed to be tested in order to ensure that the Cherenkov light detectors could measure as much light as possible, and that the glue would not absorb more light with radiation damage. METHODS USED BASIC SETUP The setup to measure the radiation damaged quartz along with the SES406 consists of a monochrometer that shoots a beam of light with specified frequencies through the sample bars. After the light travels through the quartz, it goes though a collimator and then into an integrating sphere. The integrating sphere has a shutter that can be opened and closed from outside the dark box. Once the light passes through the shudder and into the integrating sphere it bounces the light around inside, and shoots it into a photomultiplier tube. All of the equipment is connected to a MS-DOS computer program, which displays the output current for each run. QUARTZ BAR SAMPLE INTEGRATING SPHERE WITH PMT ATTACHED MONOCHROMETER Q weak Detector at Jefferson Lab PROCEDURE With the stated setup, the procedure for measuring the transmission of light though the quartz bars consisted of recording the displayed output current at 250nm, 275nm, 300nm, 400nm, and 500nm. First we needed to measure the dark rate of the box, so we closed the shudder to prevent the monochrometer from shooting light into the PMT. Usually the dark rate measured around nA. Additionally, it was necessary to take with the sample in and out. In order to do this, we would set the desired frequency and high voltage, and then we would take a total of 10 runs, alternating the quartz bar sample being in and out of the beam of light, providing 5 runs with the sample in and 5 runs with the sample out. We would use this method for a control sample and an experimental sample glued together with SES406 that was exposed to 1 Mrad of radiation. ANALYSIS The transmission data collected was analyzed using the following equation: Where Tuncor is the transmission percentage without Fresnel correction factor included, Idark is the output current of the dark rate, and Iin and Iout are the output currents with the quartz sample in and out, respectively. According to Fresnel’s correction factors, different amounts of light are reflected at different frequencies of light. Therefore, we need to account for this reflection by multiplying Tuncor by its appropriate correction factor. After accounting for Fresnel reflection, the transmission data could be analyzed. CONCLUSION We resolved all the systematic issues with the addition of the collimator and the subtraction of stray light. Comparison of glued and control slide show that glue causes <1% loss of transmission in the UV.