Karl Fischer Titration

Slides:



Advertisements
Similar presentations
Laboratory Instrumentation in a Mid-size Winery
Advertisements

MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Biochemical Oxygen Demand (BOD) CE Lab. Introduction The Biochemical Oxygen Demand (BOD) test measures the oxygen consumed by microorganisms in.
Stoichiometry Chapter 5. Stoichiometry Quantitative relationships between reactants and products The balanced chemical equation gives us the relationships.
Reduction- Oxidation Reactions
1 Calculating the Cell Potential The process of calculating the cell potential is simple and involves calculation of the potential of each electrode separately,
Titrations. Homework Ch 5 Homework Ch 5Problems 3,4,6,9,12,13,14 Due Wed Oct 16.
Determination of Vitamin C Concentration by Titration
Copyright McGraw-Hill Chapter 17 Acid-Base Equilibria and Solubility Equilibria Insert picture from First page of chapter.
Titremetric analysis Dr. Mohammad Khanfar. Concept of Titremetric analysis In general, we utilize certain property of a substance to be analyzed in order.
Volumetric Analysis.
Solution Stoichiometry
Redox Titrations Introduction 1.) Redox Titration
Redox reagents, equations, titrations, and electrolysis.
Determination of bicarbonate in blood
CHM 101/102 Laboratory Manual Water Hardness: Determination with EDTA General Chemistry 101/102 Laboratory Manual University of North Carolina at Wilmington.
Redox Titrations Introduction 1.) Redox Titration
Chapter 16: Applications of Aqueous Equilibria Renee Y. Becker Valencia Community College 1.
Additional Aspects of Aqueous Equilibria BLB 11 th Chapter 17.
Buffered Solutions (sections 1-2) Acid/Base Reactions & Titration Curves (3) Solubility Equilibria (sections 4-5) Two important points: 1. Reactions with.
Classical and Thermal Methods
Solutions Solubility -the amount of solute that can be dissolved to form a solution. Solvent – the substance in a solution present in the greatest amount.
Determination of Water by the Karl Fischer Titration:
© Institute for International Research, Inc All rights reserved. Module 2: Regulations.
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Coulometric Methods A.) Introduction:
CHAPTER 12 ELECTRODE POTENTIALS AND THEIR APPLICATIONS TO XIDATION/REDUCTION TITRATIONS Introduction to Analytical Chemistry.
The Breathalyzer.
CHEM 1031 DETERMINATION OF THE PERCENT ACETIC ACID IN A VINEGAR SAMPLE.
Redox reagents, equations, titrations, and electrolysis.
Titration Example Problem Suppose that 10.0g of an unknown monoprotic weak acid, HA, is dissolved in 100 mL of water. To reach the equivalence point, 100.0mL.
Vitamin C tablets vs. Citrus fruit juice
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
Chapter 8 Bulk Electrolysis: Electrogravimetry and Coulometry.
17.1 – The Common-Ion Effect The Common Ion Effect = the suppression of the ionization of a weak acid or base by the presence of a common ion from a strong.
Determination of blood glucose Done by: Sahar Al-Subaie.
Volumetric analysis 4th lecture.
SOLUBILIZATION Physical Pharmacy SOLUBILIZATION By Abdul-Wahhab Khedr Demonstrator of Pharmaceutics & Industrial Pharmacy.
Ch 17: Instrumental Methods in Electrochemistry Principle parts of a personal glucose monitor (covered in the section on Amperometry) The following chapter.
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
Coulometric Titration Answers for prelab and write up.
Potentiometric titrations. Principle It mesures the change in potential, can be used for all kinds of titration : It mesures the change in potential,
5.3.1 Neutralization reactions Titration Reactions.
General chemistry Lab 2. Chemistry Analytical Chemistry Gravimetric Analysis Oxidation and Reduction Reactions Oxidation and Reduction Reactions Instrumental.
Titrations Definition: Volumetric determination of the amount of an acid or base by addition of a standard acid or base until neutralization.
Free Residual Chlorine Measurement
Basics of Titration by Michael Margreth.
PRACTICAL SKILLS ON THE TOPIC DETERMINATION OF RESIDUAL CHLORINE IN WATER.
Redox Titrations A redox titration is the same as an acid-base titration except it involves a redox reaction and generally does not require an indicator.
Chapter 15. Section 1  The Ionization Constant of Water (K W )  Water self-ionizes to a small extent to form H 3 O + and OH -  The concentrations.
Dr.Shuchita Agrawal BTIRT Sironja,Sagar(MP)
Lecture Date: March 26 th, 2012 Classical and Thermal Methods.
10.3 Acid- Base Stoichiometry: TITRATION. What is a titration? A procedure used to determine the concentration of a solution using a standardized solution.
Chapter 13 Titrations in Analytical Chemistry. Titration methods are based on determining the quantity of a reagent of known concentration that is required.
Experiment two The identification and the assay of Ammonium Chloride
QUANTITATIVE ANALYTICAL CHEMISTRY PRACTICES
Titration Chapter 21 section 1.
DETERMINATION OF WATER CONTENT AND ASH CONTENT
7.00 Let the Titrations Begin
Electroanalytical – Coulometry and Conductivity Ch 24, 7th e, WMDS)
Glass ware for Volumetric measurements
Introduction to Solutions
KF Coulometry.
Electrolysis AQA Chemical Changes 2 Reactions of acids
Analysis of antacid By titration
Karl Fischer Titration
Karl Fischer Titration
EXP. NO. 6 Acid Base Titration
Water content determination by Karl Fischer titration
Neutralization reactions
Presentation transcript:

Karl Fischer Titration Regina Schlink Metrohm Ltd, Herisau

Topics KF reaction Volumetric KF Titration Coulometric KF Titration Endpoint indication Drift as second endpoint indication Parameters KF Instruments

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

Method for water determination in technical products (oil, plastics and gases) in cosmetic products in pharmaceutical products in food industry In addition to determination of pH, weighing, acid-base titration, determination of water-content is one of the most frequently used methods in laboratories world wide. In 1935 KF published his “New Method for the Determination of water…”. Many chemists have since been occupied with this reagent. It is used in various industries, from quality control of raw materials to water determination in pharmaceutical products.

The KF reaction I. CH3OH + SO2 + RN  [RNH]SO3CH3 II. H2O + I2 + [RNH]SO3CH3 + 2RN  [RNH]SO4CH3 + 2[RNH]I (RN = Base) SO2 + ROH -> ester, which is neutralized by the base. Anion of alkyl sulphurous acid = reacting compound, already present in the KF reagent. Titration: Oxidation SO32- -> SO42- by I2, consumes water. Stoichiometric reaction suitable ROH to esterify SO2 completely Suitable base for complete neutralization pH 5-7 preferred (optimized by imidazole) pH adjustment of prime importance => reaction rate is constant Reaction only takes place as long as sample releases water

Basic ingredients of KF reagents Iodine Sulphur dioxide Buffer Solvent I2 SO2 Imidazole Methanol Reagents needed to carry out KFT Water comes from the sample, other components of reaction from reagent

Optimum: pH range between 5 and 7 pH dependency log K < pH 5: log K increases linearly with pH reaction rate to low (low results) 5.5-7: optimum, reaction rate constant >8: reaction rate increases slightly (side reactions probably occur) pH Optimum: pH range between 5 and 7

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

KF titration methods Volumetric KF titration Coulometric KF titration Volumetric -> classical titration, I2-containing titrant is added via buret Coulometric -> titrant is produced from I- in solution by anodic oxidation H20 calculated out of applied current Both methods: -titration cell as impervious as possible (atmospheric water!) -water adhered to wall of cell -> removed by swirling conditioned solvent Working medium & titrant Iodine is generated in titration cell (anodic oxidation)

Volumetric KF titration step by step Fill titration vessel with solvent Pretitration with KF reagent Add the sample Titrate with KF reagent Volumetric Higher (absolute) water contents Solid or pasty samples can be directly introduced Variety of suitable solvents, specifically adapted Lower detection limit (50-100 ppm) No stable titre -> determination of titre regularly Why pretitration? O-ring and molecular sieve -> change regularly (in general 6 weeks, depends on air-humidity)

Volumetric KF reagents One component reagents Titrant contains iodine, sulphur dioxide, buffer and methanol/ethanol Working medium contains only the methanol/ethanol Disadvantage: the titre decreases 5% per year in the closed bottle! Two component reagents Titrant contains iodine Solvent contains buffer and sulphur dioxide Advantages: pH optimum in the solvent / fast reaction / titre is very stable Two possibilities for working medium and titrant 1-Component: flexibility regarding solvent additives for improving solubility of sample Titrant 5 mg/mL: 5 mg H2O can react with 1 mL Titre determination: Water Std 10 recommended, Na-tartrat not as reproducible (bad solubility in methanol) dest water possible, but very tiny amount, good practice needed

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

Coulometric KF titration step by step H+ H I I- - + current is our burette iodine is produced from a iodide containing solvent by anodic oxidation generating current is switched off as soon as a slight excess of free iodine is present free iodine is indicated by a double platinum electrode Not a classical titration -> “electronic buret” Same chem. process as volumetric KFT: 1 H2O consumes 1 I2 I2 generated electronically -> absolute method -> no titre Instrument measures time + current flow to EP -> prop. I2 -> prop. H2O Primarily for small amounts of water Metrohm: 10 g – 200 mg H2O, resolution 0.1 g

Coulometric KF titration I2 produced by generator electrode, 2 different types: Cell without diaphragm - easy to handle and clean - only 1 reagent (!!!Use only reagents intended for these electrodes!!!) - electrode rapidly ready for use (no water on diaphragm) - no cathode compartment -> reduction on Pt plate b) Cell with diaphragm - ketones/aldehydes in sample (special reagents available only for this type) - reagents with low conductivity - lower trace range Cell with diaphragm Cell without diaphragm

How to fill coulometric cell with diaphragm? Catholyte 5 mL Reduction: 2 H+ +2 e- = H2 change catholyte weekly! Anolyte: about 100 mL 2 I- = I2 + 2 e- Reagents anolyte -> titration vessel catholyte -> cathode compartment same level of both (prevents pressure compensation) EP: double Pt electrode Absolute -> no titre determination Check from time to time with certified standard

Comparison with and without diaphragm With diaphragm Recommendable for most applications, sample should have a good solubility in alcohol Reagents with low conductivity (the addition of chloroform or xylene > 10%), with ketone reagents absolute water content < 50 ppm Generator I: 400 mA Generator I: auto With diaphragm low water content, conductivity Anode + cathode compartment separated to avoid interferences Allows application of lower current densities of 100-200 A

Coulometric KF reagents Capacity of more than 1000 mg of water (100 mL KF reagent) Anodic and cathodic reagents Combined reagents Special reagents for ketones 2 reagent solutions necessary for cell with diaphragm: anolyte: modified KF reagent, containing I- instead of I2 KF reaction occurs in anolyte catholyte: enables counterpart cathode reaction which must proceed so that the by-products of the KF-reaction produced at the cathode are not disturbed Combined reagents: Merck reagents and Coulomat E, in both compartments same solution Keton reagents <- side reactions

Which is the right method for my application? Volumetric titration range of application 0.1 % - 100 % depends on sample size Coulometric range of application 0.001 % - 1 % (10 µg - 200 mg absolute water content), mainly liquids and gases

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

Endpoint indication Bivoltametry Ipol = 50 uA Constant current applied to double Pt electrode During titration: Excess H2O  High voltage between Pt wires Ipol: Small current is applied to between the electrodes (AC much more sensitive than DC) and resulting voltage is measured. As long as there is H2O-> high voltage is applied (I2 -> I-) End of titration: reaction turnover is decreasing (small excess of free I2) -> strong decrease of voltage EP is determined by entering switch-off voltage. Reagent addition stops when reached At end of titration: Small excess of free iodine  Voltage decreases sharply

Endpoint indication Voltage: High as long as H2O in sample + I2 added Once reaction turnover decreases, potential decreases End point is not sufficient as criteria (titration would stop at signal at 88 sec) -> Additionally drift as EP criteria Drift <- water entering system

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

permanent consumption of KF reagent  Drift Aim: constant and low drift Optimal: Volumetry <10 L/min Coulometry 2...10 g/min Influence on the results  drift correction Drift correction: 20 ug/min drift and 1 min measurement, Sample 10 ug => 30 ug => correction necessary Drift higher than sample -> lower drift recommended for trace analysis Optimal drift is for europe, depends on humidity, air condition might be good in some countries for trace analysis

Drift Start drift – acceptable drift value for start of determination (cond. OK) Stop criteria drift – absolute or relative drift value Absolute drift– the entered value is the stop drift Relative drift – the stop drift is calculated from the measured drift value (start) and the entered value

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

Titration parameter Volumetry Coulometry EP at U 250 mV Dynamics 100 mV Stop criteria drift/time Stop drift 20 uL/min Delay time 10 s I(pol): 50 uA Coulometry EP at U 50 mV Dynamics 70 mV Stop criteria drift/rel drift Stop drift 5 ug/min Rel. Drift 5 ug/min Start drift 20 ug/min I(pol) : 10 uA Standard parameters Dynamics: near to EP -> add smaller amount Dynamics 100: from 350 smaller steps (volumetry), 120 (coulometry) Special parameters: Coulometer: Ketone reagents Volumeter: Ethanol reagents

Topics KF reaction Volumetric KF titration Coulometric KF titration Endpoint indication Drift as second endpoint indication Parameters KF instruments

Volumetric KF Titration Titrandos: 841 Titrando PC Control / tiamo Touch Control Titrinos: 787 KF Titrino 795 KFP Titrino

Volumetric KF Titration Modi 841 Titrando KFT X SET Meas High-end titrator for up to four 800 Dosino dosing systems. Karl Fischer titration (KFT) and endpoint titration (SET), pH measurement (MEAS), liquid handling. With four MSB connections, one measuring interface; USB connection.

Only a version with dosing units ? Advantages: The dosing unit can be totally emptied that means: No crystallisation in cock and tubings Rinsing the buret several times after changing the titrant is no longer necessary Direction downwards -> no air-bubbles dosed Possibility to empty totally -> saves reagents

Coulometric KF titration 756 Coulometer with internal printer 831 Coulometer Work relatively precisely Both available with generator electrodes with or without diaphragm Differences: Printer included 756 Optional: Automatic reagent changer (after a defined time)

Principle of the oven technique Many substances release water slowly or at elevated temps -> not suitable for direct KFT Further problem: low solubility of sample in alcohol, side reactions of other substances => Substance heated in oven, locate upstream from cell Released water is transferred by flow of dry carrier gas to titration cell, where KFT takes place => Only water enters cell => No unwanted side reactions + matrix effects and contaminations Coulometric cell Vial placed in the oven

832 Thermoprep 774 Oven Sample Processor Oven for volumetric and coulometric KFT 832 -> stand alone 774 -> automated