Connector Installation Guide For Compression and Mechanical Connectors

Slides:



Advertisements
Similar presentations
Christel Hunter, Alcan Cable Butch Hartwick, FCI Burndy
Advertisements

Special Mines Services An Employee Owned Company.
for Storm Survival, Long Term Reliability and Safety
ELECTRICAL RECEPTACLES
Introducing Electricity and Electrical Safety
Grounding Electrodes.
Presentation : IMS – Tech Managers ConferenceAuthor : IMS StaffCreation date : 08 March 2012Classification : D3Conservation :Page : # 05 - Wiring Methods.
Unit 11 Wire Tables and Conductor Sizes. Objectives: Discuss factors that determine conductor ampacity. Discuss resistance of wire. Determine insulation.
Basic Electricity.
75 years of excellence NEMA RV 3 Application & Installation Guidelines For Flexible & Liquid Tight Flexible Metal Conduits.
FAILURE MODES AND PRACTICAL APPLICATION CONNECTOR THEORY Your Presenter: Arnie Cobb Product Manager Distribution Connector Products.
Electrical Wiring Practices
Flange-lok Installation Instructions Quick Installation Guide rev. DB.
Inspecting Electrical. Inspection Includes:  Service entrance & masthead  Main panel and subpanels (if any)  Branch circuit wiring  Junction boxes,
Electronics. Solid snap together electronic connectors.
Telecom Cabling Grounding and bonding.
Gear Drive Flo-tap Installation Instructions Quick Installation Guides: rev. EA – 485 Flanged Flo-tap rev. DB – 485 Threaded.
Chapter 7 Metals.
Electrical Wiring Residential
EET Survey of Electronics
Electrical Power Systems
OBJECTIVES 1. Create correctly sized connectivity cabling.
TP4-ENERSOL-TD/PV double function
2011 NEC ROP - CMP 5 Report to SCC 18
2014 CHANGES TWO MINUTE DRILL COPYRIGHT TED “SMITTY” SMITH ©2014.
GROUNDING.  Why ground?  Types of Grounding methods  Telecom grounding system  Bonding in Telecom room  Materials for grounding and bonding.
Electrical Wiring. Wire Size Comparison MEl ec- Ch #16 top to #10 bottom #2 top to #10 bottom.
COMMERCIAL SERIES TRI-POINT ANCHORING SYSTEM
The printed circuit board (PCB) design
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
Die Cast – Nickel Die Cast – Black Metalized Plastic Black Plastic Grey Plastic Plastic - Assorted Colors –Available only on 972 Series.
AWG, American Wire Gauge
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 25- Residential Improving your skill in code Look Up Increasing Speed Drill.
2005 NEC ® Code Changes Presenter Mark Nowak North East Specification and Project Manager.
Engineering Technology Division
Lighting and Wiring Services
Basic Electricity.
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
Electrical Principles and Wiring Materials Unit #31.
Voltage Tester Used for testing voltage on electrical outlets, fuse clips, and circuit breakers will test voltage from 120 to 600 volts.
ThermexWELD Exothermic Welding User and Inspector’s Guide
WIRE REPAIR Chapter 4.
Ag. Mechanics for Beginning Teachers
Electrical Installation AMI- 17.0
Electrical Safety Authority
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
WIRE REPAIR. TROUBLESHOOTING STEPS l Confirm the Complaint l Study the electrical schematic l Locate and repair the fault l Test the repair.
Level 1 Diploma in Electrical Installation © 2014 City and Guilds of London Institute. All rights reserved. 1 of 13 PowerPoint presentation Stripping and.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
W. C. “Buster” Hounshell Spring 2002 SWITCHES.
Chapter 16 GMAW and FCAW: Equipment Assembly and Adjustment Miller Electric Mfg. Co.
ELECTRICAL RECEPTACLES
ELECTRICAL RECEPTACLES
Grounding the Electrical System
Grounding the Electrical System
SWITCHES W. C. “Buster” Hounshell Spring 2002.
Mechanical Dimensions
NEMA RV 3 Application & Installation Guidelines For Flexible & Liquid Tight Flexible Metal Conduits
Electrical Safety.
2014 Changes Two Minute Drill
EET 323 – Electrical System Design Lecture 9: Grounding
Wiring Circuits Lesson Plan PSTS: C6-7.
Replacing TrueAir Thermostat with Ecobee SI
Custom Switch and Value Added Capabilities
Mechanical Dimensions
North Carolina Department of Insurance Office of State Fire Marshal
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

Connector Installation Guide For Compression and Mechanical Connectors

Connector Installation Guide For Compression and Mechanical Connectors

Typical Cross Section of a Compression Connector Before Installation Connector Installation Guide For Compression Connectors Typical Cross Section of a Compression Connector Before Installation Before compression, a typical cross section of cable consists of 75% metal and 25% air

Typical Cross Section of a Compression Connector After Installation Connector Installation Guide For Compression Connectors Typical Cross Section of a Compression Connector After Installation After compression, little air is left.

Connector Installation Guide For Compression Connectors Connector Types 1 - 2 hole lug Belled-End Narrow Tongue C-Taps Splices Grid Grounding Battery Terminals H-Taps

Connector Installation Guide For Compression Connectors 1. Determine Proper Connector For Cable * Conductor size and CU = Copper conductors only * Conductor size and “AL9” = Aluminum conductors only * Conductor size and “AL9CU” = Aluminum or Copper conductors * Match size and type of conductor to proper lug Note: Consult manufacturers instructions on whether fine stranded conductors or welding cable conductor types may be used.

Connector Installation Guide For Compression Connectors Marking Information on Connectors: * Manufacturer * Wire Size * Wire material- CU, AL, or AL9CU (indicates Dual Rating and 90° C) * Optional Crimp Indicator Bands * Listing Information

Connector Installation Guide For Compression Connectors 2. Strip and Properly Prepare Cable *Strip insulation carefully to avoid nicking strands. *Strip to proper length so conductor can be fully inserted. *Refer to manufacturers instructions for strip length. *Most connectors are suitable for one conductor. Never install more than one conductor unless specifically allowed by the manufacturer’s instructions. *Aluminum Conductor – *Brush the stripped portion of the conductor to remove oxide film using a stainless steel wire brush. *Apply oxide inhibitor compound and wire brush into the stranding. Do not remove pre-filled inhibitor from the barrel.

Connector Installation Guide For Compression Connectors

Connector Installation Guide For Compression Connectors 3. Select proper installing die tool *Always refer to the connector manufacturer’s instructions for the proper compression die that is intended for the connector. *Manufacturers may use colored bands or dots that correspond to color markings on dies. *Manufacturers may use die code number marked or stamped on the connector. *Knurls may be used in place of colored bands.

Connector Installation Guide For Compression Connectors 4. Locate tool with correct die in proper position on connector and activate tool *Connectors that are banded with colored stripes to indicate number and location of each crimp. *Connectors may also be marked with the die code number at each compression location. *Follow manufacturers instructions whether to crimp on the colored bands or between the colored bands.

Connector Installation Guide For Compression Connectors 4. Continued…. When crimped, the die code number or other marking will be embossed on connector for easy inspection to determine if correct die and connector combination were used.

Connector Installation Guide For Compression Connectors 4a. Die-less Tools Select proper installing die-less tool * Crimp as directed by the manufacturer’s instructions.

Connector Installation Guide For Compression Connectors 5. Connector Securement Use a 2-hole connector if there is a concern for twisting the connection.

Connector Installation Guide For Mechanical Connectors

Connector Installation Guide For Mechanical Connectors Connector Types Single Conductor Lug Double Conductor Lug Overhead Transformer Copper Single Conductor Lug Stud Type Transformer Double Conductor Lug, NEMA Pad

Connector Installation Guide For Mechanical Connectors Marking Information on Connectors: * Manufacturer’s name or Symbol * Wire Size or range * Wire material- CU, AL, or Both * Temperature Rating if applicable * AL9CU Shows Dual Rating (Al & Cu) and 90°C * UL and/or CSA if it is a listed connector

Connector Installation Guide For Mechanical Connectors Unlike Compression connectors, mechanical connectors typically take a range of conductors. It is important to check that the cable falls within the cable range listed on the connector. If the connector is intended to be used on a bus, pad or equipment, mount the connector and tighten the mounting hardware per the manufacturer’s specifications.

Connector Installation Guide For Mechanical Connectors 3.Strip and Properly Prepare Cable *Strip insulation carefully to avoid nicking strands *Strip to proper length so conductors can be fully inserted *Refer to manufacturers instructions for strip length *Aluminum Conductor – Brush the stripped portion of the conductor to remove oxide film with a stainless steel wire brush. Apply oxide inhibitor compound and wire brush into the stranding

Connector Installation Guide For Mechanical Connectors 4. Insert the conductor (s) and tighten all set screws per the manufacturer’s recommendations. * Do not retighten after properly torqued. * Most connectors are suitable for one conductor. Never install more than one conductor unless specifically allowed by the manufacturers instructions. * Use the mounting bolt size as recommended by the manufacturer.

Connector Installation Guide For Mechanical Connectors Split Bolts Generally used as taps. * If conductors are different materials, a spacer bar is included. Aluminum conductor should always be positioned on top.

Connector Installation Guide Connector Ratings * Voltage Rating (Insulated Only) * 300 volts * 600 volts * 1000 volts signs/luminaires * Note: NOT MARKED Un-insulated listed connectors are suitable for 2,000 volts. They may be used over 2,000 volts up to 35,000 volts where the effects of corona have been investigated.

Connector Installation Guide Connector Ratings * Non-insulated Temperature Rating 75°C -Use the connector at 75°C ampacity 90°C -Use the connector at 90°C ampacity * Higher temp rated conductors at higher ambient temperatures may be used as long as the ampacity levels are used per the connector rating. * Use the NEC® to obtain the conductor ampacity ratings.

Connector Installation Guide Connector Ratings * Insulated Temperature Rating * Never exceed the temperature rating of an insulated connector. See Packaging or Product for the marking.

Connector Installation Guide Connector Rating Marking * Conductor Material * AL 9 Aluminum 90°C * AL9CU CU9AL Aluminum/Copper 90°C * AL7 Aluminum 75°C * AL7CU CU7AL Aluminum/Copper 75°C CU9AL

Connector Installation Guide for Grounding Connectors * DB Direct Burial * The connector is suitable for direct burial in the soil or embedded in concrete.

Connector Installation Guide for Grounding Connectors DB = Direct Burial Suitable Conductor Compression Die Information

Connector Installation Guide For Compression and Mechanical Connectors Connector Installation Guide for Grounding Connectors Connector Installation Guide For Compression and Mechanical Connectors Grounding Connections * Look for the product markings for suitability for attachment to rods, pipe, and concrete encased reinforcement steel.

Connector Installation Guide for Grounding Connectors Grounding Connections Rod size Conductor size

Connector Installation Guide For Grounding Connectors Grounding Connections Direct burial Conductor size Rebar size

Connector Installation Guide For Compression and Mechanical Connectors SAFETY STANDARDS

Connector Installation Guide For Compression and Mechanical Connectors Safety Standards Wire Connectors UL 486A-486B CSA C22.2 No. 65 ANCE NMX-J-543 Splicing Wire Connectors UL 486C CSA C22.2 No. 188 ANCE NMX-J-548 Grounding and Bonding Equipment UL 467 CSA C22.2 No. 41 ANCE NMX-J-567

Electrical Connector Section Connector Castings Inc. Connector Mfg. Co. Cooper Power Systems ERICO, Inc. Galvan Industries, Inc. Homac Mfg. Co. Hubbell Power Systems, Inc. Ilsco FCI/BURNDY MacLean Power Systems Panduit Corporation Sicame South Atlantic/Southern Grounding Thomas & Betts Corp. Tyco Electronics

QUESTIONS?