Plastic Containers: What could be leaching into our food? M.J. Kolodziejski*, Principal Chemist; E.J.Tullo, Principal Chemist, J.M. Roark, Group Leader;

Slides:



Advertisements
Similar presentations
Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

Gas Chromatography 427 PHC.
GAS CHROMATOGRAPHY.
Week 3 Collection and Analysis of Biodiesel
Detection of Leaching Organic Migrants from Polyethylene Terephthalate (PETE #1) and Polycarbonate (PC #7) water bottles. Paul Dornath Paul Dornath School.
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
Plastics such as Polyethylene (PE), polypropylene (PP), High Density Polyethylene (HDPE) and polyethylene terephthalate (PET) are increasingly recycled.
DISTILLATION.
OSBI Toxicology Lab Current Technologies for Blood Testing
HPLC Coupled with Quadrupole Mass Spectrometry and Forensic Analysis of Cocaine.
Lecture 14 LC-MS Ionization. GC Computer MS GC-MS.
Standard Addition Used with difficult matrices such as blood Difficult to get an accurate comparison of the amount of analyte in sample vs. amount of analyte.
ACADs (08-006) Covered Keywords Titrations, chemical separations, distillation, carrier use, gravimetric determinations, fusing, precipitation, sample.
Experiment 24: SYNTHESIS AND GC ANALYSIS OF FATTY ACID METHYL ESTERS.
Lecture 8. GC/MS.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
What is Chromatography?
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Instant Notes Analytical Chemistry
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
ESTERS: SYNTHESIS AND FRAGRANCE
Gas Chromatography And Mass Spectrometry
Experiment 24: SYNTHESIS AND GC ANALYSIS OF FATTY ACID METHYL ESTERS.
Distillation and Chromatography. Objectives Separate the components of a solution using distillation and chromatography Determine physical or chemical.
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
Mass Spectrometry Mass spectrometry (MS) is not true “spectroscopy” because it does not involve the absorption of electromagnetic radiation to form an.
Solutions and their Behavior Chapter Identify factors that determine the rate at which a solute dissolves 2. Identify factors that affect the solubility.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
What is Chromatography? Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
My Experiment Color Chromatography
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Separation Science Differences in IMFs can be used to separate chemical substances for further analysis. Differences in IMFs can be used to separate chemical.
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
ERT 207 ANALYTICAL CHEMISTRY
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Standard Addition Used with difficult matrices such as blood Difficult to get an accurate comparison of the amount of analyte in sample vs. amount of analyte.
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
Properties of Matter Physical Properties: Can be observed without changing a substance into another substance. Boiling point, density, mass, volume, etc.
Combining and Choosing Analytical Techniques Chapter 8.
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
HPLC – High Performance Liquid Chromatography
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
Chapter 29 Supercritical Fluid Chromatography and Extraction.
液相層析質譜分析 LC-MS Method development and Analyte Identification 授課教師:賴滄海教授 授課教師:賴滄海教授
Chromatography Chapter Dr Gihan Gawish. 1. Paper Chromatography Dr Gihan Gawish  Paper chromatography is a technique that involves placing a small.
Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify the mixture or components.
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
Dr Saleha Shamsudin. 1.INTRODUCTION Topics to be covered: 1.1 INTRODUCTION TO METHODS IN ANALYTICAL CHEMISTRY 1.2 STEPS IN QUANTITATIVE ANALYSIS.
PURIFCATION OF ORGANIC COMPOUNDS
Impurities in Drugs author: srikanth N
1 Classification and purification of Organic Compounds.
YOU CAN ALSO BE AN ANALITYCAL CHEMIST Emilia Grygo-Szymanko Paweł Świt Jagiellonian University in Krakow Faculty of Chemistry Department of Analytical.
Introduction to Gas Chromatography
Presented by Deepthi Ravipati. Barbiturates are derivatives of barbituric acid. They act as central nervous depressants. These drugs are frequently used.
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
Drug detection and analysis
Go through and complete notes from the PowerPoint on the class website
Overview Determining Identity Quantitative Analysis
What is Chromatography?
Automation of Sample Preparation for Trace Analysis Haibin Wan
Mass Spectrometry Courtesy
Preparation of Methyl Benzoate
Organic Instrumentation
What is Chromatography?
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
What is Chromatography?
What is Chromatography?
Presentation transcript:

Plastic Containers: What could be leaching into our food? M.J. Kolodziejski*, Principal Chemist; E.J.Tullo, Principal Chemist, J.M. Roark, Group Leader; A.J. Miller, Chemist; W.B. Atkins, Senior Chemist Purpose: Many foods and drug products that we consume are packaged in plastic containers. The purpose of this study was to generate extractables profiles for black crystalline polyethylene terephthalate (CPET) microwave food trays; clear, colorless polyethylene terephthalate (PETE) disposable water bottles; and polycarbonate (PC) reusable beverage containers to demonstrate a practical approach for generating extractables profiles for pharmaceutical container/closure systems. These profiles provide the identification and approximate concentration of compounds that could potentially leach from container/closure systems into food or drug products. Methods: Each container component was cut into approximately half-inch squares so that a total surface area to volume ratio of 60 cm 2 per 20 mL extraction volume was achieved, as per USP Biological Reactivity Test. Three extraction solvents (water,ethanol, and hexane) were used to reflux each component at boiling conditions for thirty minutes. Each extraction solution was subsequently analyzed by direct injection GC-MS for semi-volatile organic compounds; and by Liquid Chromatography- Mass Spectrometry (LC-MS) for non-volatile organic compounds. The LC-MS analysis was performed using three modes of ionization; atmospheric pressure chemical ionization in positive mode (APCI + ); electrospray ionization in the positive mode (ESI + ); and electrospray ionization in the negative mode (ESI - ). In addition, Headspace Gas Chromatography Mass Spectrometry (GC-MS) analysis was performed on sample that was not exposed to reflux extraction. For the determination of metals and elemental extractables, ICP-OES analysis was performed on an acid-digested solution of each component. Conclusion: A complete extractables profile was generated for each component tested. This same methodology is also used to characterize extractables compounds for pharmaceutical container closure systems, as required by the FDA’s guidance document, “Container Closure Systems for Packaging Human Drugs and Biologics.” Abstract Methods and Materials References Objective The objective of the study is to provide an extractables profile for common food container components. Similar techniques can be applied to pharmaceutical container/closure systems to provide initial characterization of potentially leachable components. Extraction Equipment:  50-mL round-bottom flasks  Condensers  Heating mantels with rheostat Instrumentation:  Agilent 6890 GC with 5973 MSD  Agilent G1888 Headspace Autosampler  Agilent 1100 LC/MS Trap SL  Perkin-Elmer Optima 5300 ICP-OES Sample Descriptions:  Polyethylene Terephthalate (PETE) Water Bottle, Clear, 500 mL  Black Crystalline Polyethylene Terephthalate (CPET) Microwave Food Tray  Polycarbonate (PC) Reusable Beverage Container, 1-Liter Sample Preparation: Reflux: For each solvent, an approximately 30 cm 2 portion of each component was cut into approximately one cm pieces prior to placement into a 50-mL round- bottom flask for reflux. Three reflux solvents were used, including water, ethanol, and hexanes. Approximately 18 mL of solvent was added to each sample. A cool-cycled condenser was attached prior to heating. Each was heated to boiling and continued to boil for 30 minutes. After 30 minutes, samples were cooled prior to transfer into 20-mL volumetric flasks. Each was brought to volume with the appropriate solvent and mixed. LC/MS Non-volatiles: A 1.0 mL portion of each was removed for LC/MS analysis. Samples were analyzed by LC/MS Trap, utilizing ES +, ES -, and APCI + ionization with external standard quantitation. For each LC/MS mode, the response for reserpine was used for system suitability determination and sample quantitation. A reserpine reporting limit standard was prepared at 1 µg/mL to be used to determine the reporting threshold. Any compound with a peak response above the reporting limit was quantitated. For each mode of ionization, a C18 reversed- phase gradient separation ranging from 10% organic to 100% organic was utilized. Mobile phase modifiers were added to facilitate ionization in each mode. For each analysis, a scan from 50 to 1500 m/z was performed. GC/MS Semi-volatiles: To the ethanol and hexane solutions, 1.0 mL of phenanthrene-d 10 internal standard solution was added for GC/MS analysis. Water samples were vortex-extracted with an equal volume of methylene chloride containing phenanthrene-d 5 internal standard for GC/MS semi-volatiles analysis. A portion of each methylene chloride layer was analyzed by GC/MS using direct- injection analysis with internal standard quantitation. A 5% phenylmethylsiloxane analytical column was utilized using a temperature-programmed elution. Each sample was scanned from 50 to 550 u. GC/MS Volatiles: An approximately 30 cm 2 portion of each sample was cut into approximately 1 cm pieces and placed into a 10-mL headspace vial. To each, a 1.0 mL aliquot of a 1,4-dichlorobenzene-d 4 internal standard solution was added. Vials were capped, and analyzed by GC/MS headspace analysis utilizing internal standard quantitation. A 6% cyanopropyl/94% dimethylpolysiloxane analytical column was utilized using temperature-programmed elution. Sample introduction was accomplished using a 1.0 mL automated headspace injection after a 10 minute incubation at 80 o C. Polyethylene Terephthalate (PETE) Bottle - Extractable Results Polyethylene Terephthalate (CPET) Tray - Extractable Results Polycarbonate (PC) Bottle - Extractable Results 1. Zweifel, H., “Plastic Additives Handbook, 5 th Edition,” Hanser Publishers, Munich, NIST 98K Database, Version 2.0 a, National Institute of Science and Technology, Standard Reference Data Program, 4. EPA Method 8270D, “Semi-volatile Organic Compounds by GC/MS,” Revision 4, 2/2007 Results Discussion A forced extraction experiment was performed for three common food containers. The container types included clear polyethylene terephthalate (PETE) water bottles, crystalline black polyethylene terephthalate (CPET) microwave trays, and polycarbonate (PC) re- usable beverage containers. Reflux extraction using water, ethanol, and hexane solvents was performed to determine potential non-volatile and semi-volatile extractable components from each. In addition, GC/MS headspace analysis for volatile components was performed. Elemental analysis using ICP-OES following heated acid digestion was also performed. The only extractable compound tentatively identified for the PETE water bottle was diethyl terephthalate by GC/MS direct injection for the ethanol test solution. Diethyl terephthalate is the ethyl ester of terephthalic acid, an ingredient in PETE. Elemental analysis revealed the most notable concentrations of calcium and potassium. The CPET food tray also contained detectable diethyl terephthalate for the GC/MS analysis of the ethanol extract. In addition, palmitic acid ethyl ester and oleic acid ethyl ester were tentatively identified. These ethyl esters may be injection port by-products related to the presence of palmitic and oleic acids. In addition, an unidentified compound was observed by LC/MS using APCI + ionization, which displayed an apparent molecular weight of 576 u. Exact mass determination and further study would be necessary to identify the unknown. This was beyond the scope of this study. Calcium was detected at the highest concentration for ICP metals analysis. It is possible that calcium salts of palmitic acid and/or oleic acid were the source of the calcium detected. Analysis of the ethanol extracts for the PC beverage container contained the greatest number of extracted compounds. Identified compounds with the highest concentrations included 4-tert-butylphenol, stearic acid ethyl ester, and bisphenol A for the ethanol test solution by GC/MS. The 4- tert-butylphenol is a common antioxidant used for polymer preservation. Stearic acid, in the form of calcium stearate, is a common processing aid used for plastics production. Bisphenol A is a building block of the PC polymer. At the time of purchase of the materials for the study, it was becoming difficult to purchase PC beverage containers made with bisphenol A. Volatiles analysis using GC/MS headspace resulted in the identification of chlorobenzene. The presence of a solvent such as chlorobenzene may be related to labeling. LC/MS non-volatile analysis resulted in the detection of three unknown compounds, having apparent molecular weights of 597 u, 508 u, and 536 u. Based on molecular weight information only, a possible identification for the unknown with molecular weight of 508 u would be Tinuvin 765. A possible identification for the unknown with a molecular weight of 536 u could be Irganox Confirmational analysis was not possible, due to reference material unavailability. Elemental analysis resulted in detection calcium and iron at the highest concentrations. As described previously, calcium stearate may be the source of the calcium. Iron could be related to colorants. A polymer additives database has been developed by Lancaster Laboratories, which currently contains approximately 120 compounds. The database includes both GC/MS and LC/MS spectrum in ES +, ES -, and APCI + modes.