By MTI Industries, Inc. RV Safety Alarms Education Test Carbon Monoxide Alarms.

Slides:



Advertisements
Similar presentations
Carbon Monoxide Detectors. Carbon monoxide is a gas created by incomplete burning of fuels. Carbon monoxide is colorless, odorless and tasteless, but.
Advertisements

Facts for life Carbon Monoxide Poisoning Properties of Carbon Monoxide Carbon monoxide is an odourless, tasteless and colourless gas. It is toxic to.
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
By MTI Industries, Inc. RV Safety Alarms Education Test Carbon Monoxide Alarms.
Carbon Monoxide in Your Home. What is Carbon Monoxide? CO Deadly gas Cant see, taste, feel or smell.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
RV Safety Alarms Education Test LP Gas Alarms / Detectors
OCTOBER IS FIRE SAFETY MONTH!!!!!!. What can you do to Protect yourself and your family? PRACTICE FIRE SAFETY and FIRE PREVENTION EVERYDAY!!!
2015 Update to OBC September 17, 2014.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Minnesota Department of Public Safety State Fire Marshal Division Fire Safety & Prevention.
Electrical Fire Safety Fire Prevention Week 2012 Electrical Safety Foundation International.
Carbon Monoxide Detectors & Smoke Detectors. 1.Purchase carbon monoxide (CO) and smoke detectors when you first move into a house. CO when using natural.
Know Your Smoke Alarm Updated January 29th 2008 Port Angeles Fire Department, Washington © Ver. 1.0.
Environmental Health Issue- Carbon Monoxide Presented by QBE Loss Control Services.
DZAC January 2012 Opening Remarks Ken Fletcher. Items of Interest $25 Safety Spot Award Program to start this month Interpretation of safety signs 2.
Natural Gas Pipeline Safety EDM Services, Inc. April 2009.
Chapter 19 Electrical Plans.
SOUTH CAROLINA’S FIRE PROBLEM: South Carolina Office of State Fire Marshal Public Fire Education and Data Management South Carolina Office of State Fire.
Protecting Against Carbon Monoxide in Your Home
Fire Safety For Older Adults. Older people are at special risk for death and injury from fires. To protect yourself and those you care about, follow these.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
J & P Equipment Cleaning, Inc. Thunder Ridge Mine December 7, 2008.
Created by Curt Harrell & Jesse Kuzy for. Why are Fire Alarms Important?  If the fire is small enough to be extinguished with a hand-held fire extinguisher,
BY BILLY NIGZUS TERM FIRE ALARMS. WHAT ARE FIRE ALARMS ? Fire alarms are a device or a system that alert people when there is a fire. A device.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Carbon Monoxide Response Cole County Fire Protection District.
WHO IS TLC HOME IMPROVEMENT, INC.?  FOR OVER 36 YEARS TLC HOME IMPROVEMENT, INC. HAS BEEN IN THE FOREFRONT OF THE HOME REMODELING INDUSTRY SERVING THE.
Don’t Go Without Protection from this invisible, Odorless Killer Carbon Monoxide Detectors & First Responders.
Hampton Fire / Rescue Hampton Fire / Rescue Fire Prevention Week October 3-9, 2010 SMOKE ALARMS: A sound you can live with.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Information Smoke Alarms AGAL A business unit of the Australian Government Analytical Laboratories (AGAL).
Ontario Building Code Revision effective Jan 1, 2015
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
City of Marshalltown 2012 Employee Training - Safety.
Welcome To The Coconut Creek Fire Marshal’s Office Training Smoke Alarm User’s Manual.
HEALTH AND SAFETY IN THE HOME POLICY JULY HEALTH AND SAFETY AT HOME POLICY Why do we have this Policy? In order to make sure our properties are.
Fire Safety Month Fire Safety Tips for October Department of Risk Management James Madison University.
Washington State Department of Commerce Health and Safety Tips 2009.
Furnace Safety. AS WEATHER TURNS COLDER, BE AWARE OF AN INVISIBLE KILLER THAT CAN SEEP THROUGH THE HOME, CAUSING SERIOUS INJURY OR DEATH.
Vehicle Maintenance. Oil Your car’s lifeline The most important issue in your vehicle’s life is selecting the correct oil and changing it regularly.
MONTGOMERY COUNTY FIRE & RESCUE FAMILY CHILD CARE FIRE SAFETY NOTEBOOK Written By: M/FF Matt Kelleher 2008.
Marshall University Safety & Health Carbon Monoxide Safety.
2009 WASHINGTON STATE BUILDING CODE (WAC 51-50) RESIDENTIAL CODE (WAC 51-51) FIRE CODE (WAC 51-54) CARBON MONOXIDE ALARM REQUIREMENTS IN THE 2009 WASHINGTON.
 There are 70,000 fires each year in Canada  Preventing fires will lessen the chance of injury or death  Knowing what to do in case of fire can save.
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Fire Triangle Fuel Heat Oxygen. Life Safety –The primary goal of fire safety efforts is to protect building occupants from injury and to prevent loss.
CARBON MONOXIDE.  Carbon Monoxide (CO) is: Colorless Odorless Tasteless  Each year many people die from CO poisoning.  CO can act on the body quickly.
RV Safety Alarms Education Test by MTI Industries, Inc Makers of Safe-T-Alert Alarms (
Carbon Monoxide Poisoning The Silent Killer. What is carbon monoxide? Carbon monoxide, or CO, is an odorless, colorless gas that can cause sudden illness.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
RV SAFETY ALARMS PROTECTING YOUR DEALERSHIP. Background All new RV’s are required to have a CO Alarm installed as of Jan. 1, 2005 per the RVIA. LP Gas.
RV Safety Alarm Testing Procedures
Carbon Monoxide Detection: Code and Legislation Updates
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Carbon dioxide (CO2) and Carbon monoxide (CO)
CARBON MONOXIDE AWARENESS
AFCI Protection: AFCI Receptacles and the NEC
Chapter 19 Electrical Plans.
RV Safety Alarms Education Test
Carbon Monoxide Poisoning
Fire Alarm Tech Practice Test # 16 NICET
RV Safety Alarms Education Test Carbon Monoxide Alarms
RV Safety Alarms Education Test LP Gas Alarms / Detectors
Smoke Alarm Installation Program
Don’t Go Without Protection from this Invisible, Odorless Killer
#Invisible Killer– Carbon Monoxide
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Denver Fire Depart. License Fire Alarm Practice Test # 12
Presentation transcript:

by MTI Industries, Inc. RV Safety Alarms Education Test Carbon Monoxide Alarms

This Educational Test is designed to improve the knowledge of RV technicians as to the history and performance of safety alarms installed in RV’s. Section: Carbon Monoxide Alarms There are many potential sources of Carbon Monoxide Gas on RV’s. Engine exhaust, generator exhaust, gas stoves, grills, gas appliances, heaters, gas lanterns and even RV’s parked near by. RV Safety Alarms Education Test

CO Alarm Educational Test Question #1 When were Carbon Monoxide Alarms first required to be installed in new RV’s with “gasoline motors, gasoline generators and units gasoline generator ready” by the RVIA? A.1993 B.1996 C.2000 D.2005

Question #1 When were CO Alarms first required to be installed in new RV’s with “gasoline motors, gasoline generators and units gasoline generator ready” by the RVIA? A – All new motorized RVs - Class A, B & C are required to have a CO Alarm installed as of Oct B.1996 C.2000 D.2005 – All new RV’s are required to have a CO Alarm installed as of Jan. 1, 2005 per the RVIA CO Alarm Educational Test

Question #2 Approximately how many RV’s were manufactured without CO Alarms, between January 1985 and January 2005 – prior to the requirement to have a CO Alarm installed in all RV’s. A.2.0 Million B.2.5 Million C.3.0 Million D.4.1 Million CO Alarm Educational Test

Question #2 Approximately how many RV’s were manufactured without CO Alarms, between January 1985 and January 2005 – prior to the requirement to have a CO Alarm installed in all RV’s. A.2.0 Million B.2.5 Million C.3.0 Million D.4.1 Million – A majority of these RV’s are still in use but did not have a CO Alarm installed when first sold. CO Alarms should be installed during Service. CO Alarm Educational Test

Question #3 What is the service life of Safe-T-Alert CO Alarms installed in RV’s? A.1 Year B.5 Years C.10 Years D.Until they quit working. CO Alarm Educational Test

Question #3 What is the service life of Safe-T-Alert CO Alarms installed in RV’s? A.1 Year B.5 Years – check the date code on Safe-T-Alert CO Alarms during service and replace all alarms over 5 years old. C.10 Years D.Until they quit working. CO Alarm Educational Test

Question #4 Approximately how many motorized RV’s were manufactured between October 1993 and December 2008? The original CO Alarms installed in these motorized RV’s have reached the end of their service life and need to be replaced. A.500,000 B.675,000 C.750,000 D.2,100,000 CO Alarm Educational Test

Question #4 Approximately how many motorized RV’s were manufactured between October 1993 and December 2008? The original CO Alarms installed in these motorized RV’s have reached the end of their service life and need to be replaced. A.500,000 B.675,000 C.750,000 D.2,100,000– when servicing check the date code or replace by date on all RV’s built prior to CO Alarm Educational Test

Question #5 All CO Alarms installed on RVIA approved RV’s have passed the RV requirement for compliance with ANSI / UL STD A.Yes B.No CO Alarm Educational Test

Question #5 All CO Alarms installed on RVIA approved RV’s have passed the RV requirement for compliance with ANSI / UL STD A.Yes B. No – Some RVIA approved CO Alarms are listed to the Canadian Standard CSA Only CO Alarms that have been listed to “UL 2034 – RV use” are marked suitable for Use in Recreational Vehicles and are tested at extreme temperatures. CO Alarm Educational Test

Question #6 In what month of 2009 did CCI Controls, a long time manufacturer of CO detectors cease operations? A.January B.February C.March D.April CO Alarm Educational Test

Question #6 In what month of 2009 did CCI Controls, a long time manufacturer of CO detectors cease operations? A.January B.February – Safe-T-Alert (MTI Industries) manufacturers replacement alarms for surface & flush mount CCI Controls detectors. C.March D.April CO Alarm Educational Test

Replace: CCI Controls CO Alarms With: Safe-T-Alert CO Alarms WT Surface Mount WT Flush Mount CO Alarm Educational Test

Question #7 Carbon Monoxide Alarms must be installed high on the wall or ceiling? A.Yes B.No CO Alarm Educational Test

Question #7 Carbon Monoxide Alarms must be installed high on the wall or ceiling? A.Yes B.No – NFPA states “The location for effective performance is not generally dependent on mounting height. The density of carbon monoxide is similar to that of air at room temperature, and carbon monoxide generally mixes readily with air.” CO Alarm Educational Test Dual CO / LP Gas Alarm Model MTI has combination CO / LP Gas alarms that can replace old LP Gas Alarms to give RV’ers protection from both gases. Model fits CCI LP Gas Leak Detector cutouts and also adds a CO detection to older RV’s

Question #8 Battery Operated CO Alarms purchased at Home Depot or other big box stores are approved for RV use? A.Yes B.No CO Alarm Educational Test

Question #8 Battery Operated CO Alarms purchased at Home Depot or other big box stores are approved for RV use? A.Yes B.No – normally CO Alarms sold at the big box stores like Home Depot or Lowes are only listed to residential standards. Residential alarms are not listed to work at extreme temperatures like RV listed units are. Only alarms marked approved for “Use in Recreational Vehicles” should be installed in RV’s. CO Alarm Educational Test

Question #9 Pushing the test button on a CO Alarm only tests the circuit, not the sensor? A.Yes B.No CO Alarm Educational Test

Question #9 Pushing the test button on a CO Alarm only tests the circuit, not the sensor? A.Yes – Pushing the test button only checks the alarms circuit with a simulated electronic gas detection not the sensor. The sensor is supervised by the circuit in case of fault. The best method to test the sensor is to use a can of Carbon Monoxide Gas which can be used to verify the sensor at the 400 ppm UL calibration test point. All CO Alarms under 5 years old should be tested with Carbon Monoxide Gas at least every six months. B.No CO Alarm Educational Test

Question #10 At low levels of CO (approximately 70 ppm) how long does a properly calibrated CO Alarm take to start sounding? A.1-9 minutes B minutes C minutes D minutes CO Alarm Educational Test

Question #10 At low levels of CO (approximately 70 ppm) how long does a properly calibrated CO Alarm take to start sounding? A.1-9 minutes B minutes C minutes D minutes – Correct. A properly calibrated CO Alarm can go into alarm anywhere between 1 and 4 hours at low levels of Carbon Monoxide. CO Alarm Educational Test

Question #11 At high levels of CO (above 400 ppm) how long does a properly calibrated CO Alarm take to start sounding? A.Less than 1 minute B.1-4 minutes C.4-15 minutes D minutes CO Alarm Educational Test

Question #11 At high levels of CO (above 400 ppm) how long does a properly calibrated CO Alarm take to start sounding? A.Less than 1 minute B.1-4 minutes C.4-15 minutes – Correct. The alarm can sound anywhere between 4 and 15 minutes and still be in calibration. When testing with CO Gas be sure the alarm is warmed up prior to starting the test. D minutes CO Alarm Educational Test

Question #12 Which is an initial symptom of low to moderate CO poisoning? A. Headache B. Fatigue C. Shortness of breath D.Nausea E.Dizziness F.All of the above CO Alarm Educational Test

Question #12 Which is an initial symptom of low to moderate CO poisoning? A. Headache B. Fatigue C. Shortness of breath D.Nausea E.Dizziness F.All of the above. The initial symptoms of low to moderate CO poisoning are similar to the flu (but without the fever). Source CPSC Document #466 CO Alarm Educational Test

Question #13 Combination Smoke / Carbon Monoxide Alarms use separate battery sources to power the two different sensors. A.Yes B.No CO Alarm Educational Test

Question #13 Combination Smoke / Carbon Monoxide Alarms use separate battery sources to power the two different sensors. A.Yes B.No – RV listed combination Smoke / CO Alarms use a single battery source to power both sensors. If the battery source is removed or loses its power the RV’er will be without protection from both Carbon Monoxide and smoke until a replacement battery is installed. CO Alarm Educational Test

Question #14 Because Carbon Monoxide is invisible and a odorless tasteless gas CO Alarms must be installed in the separate bedroom / sleeping area of the RV. A.Yes B.No CO Alarm Educational Test

Question #14 Because Carbon Monoxide is invisible and a odorless tasteless gas CO Alarms must be installed in the separate bedroom / sleeping area of the RV. CO Alarm Educational Test A.Yes B.No – The National Fire Protection Association (NFPA) recommends CO Alarms be installed outside each sleeping area of a home. In RV’s CO alarms and combination CO / LP Gas Alarms are installed near the gas appliances, if the RV’er wants additional protection a second CO Alarm can be installed in the separate sleeping area.

Question #15 All Carbon Monoxide Alarms use the same audible horn pattern? A.Yes B.No CO Alarm Educational Test

Question #15 All Carbon Monoxide Alarms use the same audible horn pattern? A.Yes – Since October 1, 1998 all CO alarms are required to have a T-4 (temporal) horn pattern. The audible portion of the alarm signal shall be 4 cycles of 100 milliseconds on/100 milliseconds off, then 5 seconds off. Example - Beep.Beep.Beep.Beep. 5 seconds off Beep.Beep.Beep.Beep. 5 seconds off (Repeated) Immediately replace any CO alarm that does not have this audible horn pattern when tested. The alarm is over 5 years old. B.No CO Alarm Educational Test

Question #16 Dealers need to verify the CO alarm is operational prior to selling a used RV? A.Yes B.No CO Alarm Educational Test

Question #16 Dealers need to verify the CO alarm is operational prior to selling a used RV? A.Yes – Used RV’s should be sold with CO alarms that meet the latest safety standards and testing. Checking the date code, testing the alarm with CO gas and replacing alarms that are over five (5) years old should be part of the inspection / maintenance process prior to selling a used RV. B.No CO Alarm Educational Test

Review of Service Opportunities CO Alarm Educational Test Over 4.1 million RV’s built prior to 2005 may still be on the road without protection from CO. CO alarms should be installed during service. Over 4.1 million RV’s built prior to 2005 may still be on the road without protection from CO. CO alarms should be installed during service. Another 2.1 million plus RV’s built from 1993 to January 2008 could have CO alarms over 5 year old that should be replaced. Check date codes during service. Another 2.1 million plus RV’s built from 1993 to January 2008 could have CO alarms over 5 year old that should be replaced. Check date codes during service. Test alarms under 5 years old with Safe-T-Alert Detectagas (CO test gas in a can) Test alarms under 5 years old with Safe-T-Alert Detectagas (CO test gas in a can)

Review of Service Opportunities CO Alarm Educational Test CCI Controls has recently discontinued operations. MTI Industries / Safe-T-Alert brand CO alarms can be used as direct replacements. CCI Controls has recently discontinued operations. MTI Industries / Safe-T-Alert brand CO alarms can be used as direct replacements. Combination alarms can be used to upgrade both CO & LP Gas detection in one 12 volt wired in alarm. Combination CO / Smoke alarms can be easily disabled by removing a single battery. Combination alarms can be used to upgrade both CO & LP Gas detection in one 12 volt wired in alarm. Combination CO / Smoke alarms can be easily disabled by removing a single battery.

For more information contact MTI Industries: (800) Keep your customers safe and increase sales in your service department. Check the date codes on safety alarms during routine maintenance. Replace if alarms are over 5 years old and increase your parts and labor sales. Surface Mount Model: WT (White) Flush Mount Model: WT (White) Carbon Monoxide Alarms

Sales tools available from MTI Industries for your use include: Point-of-Purchase safety center allows customer to “test drive” the product with attention getting displays Product brochures, flyers and posters MTI advertises in online and print industry publications Visit our dealer website for new materials: