Lecture 19 Principles of optical microscopy. Illumination conjugate planes are shown in red; an image of the lamp filament is in focus at these planes.

Slides:



Advertisements
Similar presentations
Adjusting a Microscope 1Center components on optic axis 2Focus objective 3Focus condenser 4Adjust illumination lamp voltage (intensity) iris diaphragm.
Advertisements

Fluorescence and Confocal Microscopy
Microscopy Do you want a footer?.
IMMUNODEPLETION OF CONDENSIN FROM XENOPUS EGG EXTRACTS HSSΔcond.Δmockmock boiled beadsextracts cond. anti- cond. anti- α-tub Smc2 
IPC Friedrich-Schiller-Universität Jena Contrast modes in light microscopy: Bright field.
Microscopy Outline 1.Resolution and Simple Optical Microscope 2.Contrast enhancement: Dark field, Fluorescence (Chelsea & Peter), Phase Contrast, DIC 3.Newer.
Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 1 The Study of Microbial Structure: Microscopy and Specimen.
Microscopy Lecture I.
Special microscopes Light microscopes developed for special diagnostic, or research purposes. Most often used types: Stereo microscope Dark field microscope.
ERT107 MICROBIOLOGY FOR BIOPROCESS ENGINEERING Pn Syazni Zainul Kamal PPK Bioprocess.
1. Resolution (R) : separation of close objects, light wavelength NA, numerical aperture 2. Contrast : distinction of objects from background “light field”
Multi-Photon Principles - topics- l Confocal complements Multi-Photon. l What is an emission event ? l Single photon event. l Stokes’ shift and what you.
Microscopy Boot Camp /08/25 Nikitchenko Maxim Baktash Babadi.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Microbiology: What is a microbe?
Short pulses in optical microscopy Ivan Scheblykin, Chemical Physics, LU Outline: Introduction to traditional optical microscopy based on single photon.
Fiber-Optic Communications James N. Downing. Chapter 2 Principles of Optics.
P. Moghe, 125:583 1 Microscopy Techniques for Biomaterials and Cell Based Interfaces Professor Prabhas V. Moghe October 26, :583 Fall 2006.
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Fluorescence Microscopy Chelsea Aitken Peter Aspinall.
Light Microscopy Sarah Heintz. Compound Microscope The microscope uses a lens that is close to the object and uses light to focus on the real image of.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Microscope.
Microscopy.
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
DIC, fluorescence and confocal microscopy Department of Mechatronics GIST Yong-Gu Lee References: 1.“Fundamentals of light microscopy and electronic imaging,”
Nano-Electronics S. Mohajerzadeh University of Tehran.
Optical Microscopy Widefield Microscopy - Brightfield, Darkfield, DIC, Phase Contrast, Fluorescence … Total Internal Reflection (TIR and TIRF) Microscopy.
Zoology I Cytology, Embryology & Histology By Dr/ Alyaa Ragae Zoology Lecture Faculty of Oral and Dental Medicine Future University.
Analytical Tools Microscopy Chapter 4 ©2010 Elsevier, Inc.
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
Microscopy. Scale Lenses and the Bending of Light light is refracted (bent) when passing from one medium to another refractive index –a measure of how.
Honors Microbiology: Chapter 3 Microscopy and Staining
Naomi Kinjal Asaad Binoy
Fluorescence Techniques
IPC Friedrich-Schiller-Universität Jena 1 Reduction of out of focus light  Excitation light excites fluorescence more or less within the whole sample.
Microscopy 1. UNITS OF MEASUREMENT 1 m = 1000 mm (millimeters) 1 m = 1000 mm (millimeters) 1000 mm = 1 µm (microns) 1000 mm = 1 µm (microns) Bacteria.
Agenda How to make the specimen visible – Definition of Contrast
By: Rob Page and Tara Trovarello
BIO 224 Intro to Molecular and Cell Biology. Microscopes are tools frequently used in cell biology Type of microscope used depends on the specimen being.
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
Developments in Imaging Technology and Staining Techniques Unit C: Section 1.3 Science 10.
IPC Friedrich-Schiller-Universität Jena 1 ASP_MP_S2j Biophotonics Prof. Dr. Rainer Heintzmann Institut für Physikalische Chemie Friedrich-Schiller-Universität.
Fluorescence microscopy Principle and applications.
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Imaging Technology and Staining Techniques CHAPTER 1.3.
The Microscope and Forensic Identification. Magnification of Images A microscope is an optical instrument that uses a lens or a combination of lenses.
microscopy There are three well-known branches of microscopy:
Dr. Mustafa Saad Histology - Introduction 1. Histology is the study of the various tissues of the body; how these tissues appear, how they interact with.
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
Dr R.Jayaprada CONFOCAL MICROSCOPY.
Phase contrast and DIC Gerd A. Guenther 2011 Honorable Mention Nikon Small World photomicrograhy competition Image of a freshwater ciliate. Ryan McGorty,
Imaging.
Brightfield Contrasting Techniques Kurt Thorn NIC.
Microscopy.
Microscopy Group 2 Cabatit, Mendoza, Ramos, Rodriguez, Tan.
By c.Keerthana.  First described by Dutch physicist frits Zernike in  It is a type of light microscopy.  It is a contrast enhancing optical technique.
Chapter 2: Viewing the Microbial World
Microscope.
Lasers and Confocal.
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Observing Microorganisms Through a Microscope
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Dual Mode Reflectance and Fluorescence Confocal Laser Scanning Microscopy for In Vivo Imaging Melanoma Progression in Murine Skin  Yanyun Li, Salvador.
LIGHT MICROSCOPY basic
LIGHT MICROSCOPY variations
FLUORESCENCE MICROSCOPY
Microscopy.
Presentation transcript:

Lecture 19 Principles of optical microscopy

Illumination conjugate planes are shown in red; an image of the lamp filament is in focus at these planes Imaging path conjugate planes are shown in red; an image of the specimen is in focus at these planes

Transillumination Field diaphragm: will affect size of field that is illuminated at the focal plane Condenser aperture: will affect the numerical aperture of the condenser

Field diaphragm: will affect size of field that is illuminated at the focal plane Aperture diaphragm: will affect the numerical aperture of the objective for illumination Epi-illumination

Objective specifications

Brightfield or trans-illumination microscopy Simplest type of microscopy Contrast provided by absorption Biological specimens are not highly absorbing naturally Use stains, which typically require fixation, i.e. cells no longer alive Used routinely in histopathology and hematology and basic science studies for which looking at live specimen is not crucial Blood cells Tissue histology

Phase contrast microscopy First microscopic method which allowed visualization of live cells in action Nobel prize in physics was awarded to Frits Zernike in 1953 for its discovery It enhances contrast in transparent and colorless objects by influencing the optical path of light It uses the fact that light passing through the specimen travels slower than the undisturbed light beam, i.e. its phase is shifted

Phase contrast microscopy Let S (red) be light passing through medium surrounding sample and D (blue) light interacting with specimen. S and D typically interfere to yield P (green), which is what we can usually detect. P will be phase shifted compared to S, but our eyes cannot detect phase shifts. Phase contrast microscopy effectively converts this phase shift into an intensity difference we can detect

Phase contrast microscopy Condenser annulus allows only ring of light to reach the condenser. Light rays illuminating the sample but not interacting with it will go straight through and be imaged along a ring at the back focal plane of the objective Light rays diffracted by the sample are phase shifted by a approximately a quarter wavelength and will be scattered over a range of angles and will generally not propagate in the exact forward direction A phase plate at the back focal plane of the objective alters selectively the phase and magnitude of the non-diffracted wave. (reference)l Phase plate (ex)

Differential interference contrast Differential Interference Contrast (DIC) microscopy converts phase shift gradients across different parts of a specimen into intensity differences. Doesn’t suffer from some artifacts seen in phase contrast Uses full NA of objective

Mouse fibroblast embryo, 24.3 hour time lapse video DIC image of nematode embryo

Principle of fluorescence Principle of Fluorescence 1. Energy is absorbed by the atom which becomes excited. 2. The electron jumps to a higher energy level. 3. Soon, the electron drops back to the ground state, emitting a photon (or a packet of light) - the atom is fluorescing.

Fluorescence Stoke’s shift Fluorescence emission peak wavelength is red-shifted with respect to absorption peak wavelength This shift may vary typically from 5 to more than 100 nm, depending on the electronic structure of the molecule

Advantages of fluorescence Highly sensitive method Simple implementation Highly sophisticated fluorescent probes –Fluorescent dyes that accumulate in different cellular compartments or are sensitive to pH, ion gradients –Fluorescently tagged antibodies to specific cell features –Endogenously expressed fluorescent proteins »Really endogenous NADH/FAD: enzymes involved in ATP production structural proteins: collagen/elastin amino-acids: tryptophan/tyrosine »After gene modification Green fluorescent protein and variants

Optical path of fluorescence microscope Dichroic filter: reflects excitation and transmits fluorescence

You can image simultaneously or sequentially the same sample at different excitation emission wavelengths to look at different cell components Cell nucleus stained with blue Hoechst dye Mitochondria stained with Mitotracker red Actin cytoskeleton stained with phalloidin derivative conjugated to Alexa 488 (green)

Photobleaching often limits the number of exposures or the exposure time Photobleaching is the irreversible photochemical destruction of the fluorescent chromophores

Resolution is limited in thick specimens by detection of out-of-focus fluorescence In a standard fluorescence microscope, the excitation beam illuminates uniformly a wide field of the sample. If the sample is thick, fluorescence will be excited within the focal plane, but also within planes above and below the focus. Some of this fluorescence will be imaged onto the detector and will result in a defocused-looking image Human medulla rabbit muscle pollen grain fibers

Principle of confocal microscopy In confocal microscopy two pinholes are typically used: –A pinhole is placed in front of the illumination source to allow transmission only through a small area –This illumination pinhole is imaged onto the focal plane of the specimen, i.e. only a point of the specimen is illuminated at one time –Fluorescence excited in this manner at the focal plane is imaged onto a confocal pinhole placed right in front of the detector –Only fluorescence excited within the focal plane of the specimen will go through the detector pinhole –Need to scan point onto the sample

To create confocal image, scanning is required Either specimen is scanned past excitation beam or laser beam is scanned across specimen For biological experiments, it is most common to scan the laser beam across focal plane using a combination of two galvanometric- driven mirrors

CONFOCAL SCANNING LASER MICROSCOPE Optical train of a confocal microscope

CONFOCAL SCANNING LASER MICROSCOPE Optical train of a confocal microscope

CONFOCAL SCANNING LASER MICROSCOPE

Elimination of out-of focus fluorescence yields superior images

A thick specimen can be optically scanned in three dimensions and the images can be processed to yield cross-sections along plane of interest, three dimensional composites and animations Pollen grain Hamster ovary cells Mouse intestine

In vivo depth-resolved imaging is possible Tumor cells grown subcutaneously in mice, expressing Green Fluorescent Protein Blood vessels stained with Cy5-conjugated anti-PECAM antibody Study interactions of tumor cells with their environment and potential factors/drugs that affect processes, such as tumor growth or metastasis

Video rate microscopy captures dynamic interactions Monitor cell-cell, cell- environment interactions in natural environment to understand animal and human biology and processes involved in disease development Monitor dynamic interactions

In Vivo Reflectance Confocal Microscopy of human skin 3-AXIS TRANSLATION STAGE ROTATABLE HEAD MECHANICAL ARM OBJECTIVE LENS HOUSING RING-AND-TEMPLATE (attached to skin and locks into the housing) VivaScope by Lucid Courtesy of S. Gonzalez

OPTIMUM RANGE PARAMETERS FOR RCM OF HUMAN SKIN Tissue Stability M-T clamping fixture Illumination Power up to 40 mW Imaging Rate frames/sc Detector aperture diameter µm Objective lenses X, NA Refraction index medium 1.33 (water) Wavelengths nm (visible) nm (NIR)

Confocal in vivo H&E VERTICAL Hematoxylin & Eosin stained section of tissue “En face” SECTION Rajadhyaksha M, González S, et al. J Invest Dermatol 1999;113; µm 100x, 1.2NA SC SG SS DEJ Reflectance-mode Confocal Microscopy Live Normal Skin

Elongated nuclei - Monomorphism Uniform Polarization of nuclei 20 µm 60 x, 0.85 NA 250 µm x y Stained in vitro section In vivo confocal Courtesy of S. Gonzalez

Criteria Sensitivity %Specificity % Elongated monomorphic nuclei10071 Polarized nuclei 9297 Inflammatory infiltrate 8355 Increased vascularity 8854 Pleomorphism or more criteria or more criteria or more criteria 8396 OVERALL SENSITIVITY AND SPECIFICITY Results remained reliable across study sites and across Basal Cell Carcinoma subtypes. Combination of clinical photograph examination and reflectance confocal microscopy evaluation significantly improved non-invasive diagnosis of BCC Courtesy of S. Gonzalez

Multiphoton microscopy At very high photon densities, it becomes possible for two or more photons to be simultaneously absorbed Each multiple absorption induces a molecular excitation of a magnitude equivalent to the sum of the absorbed photon energies

Multi-photon fluorescence: Basic principles Multi-photon excitation is a nonlinear process Because two photons are required for each excitation, the rate of two-photon absorption depends on the square of the instantaneous intensity. Because of the large intensities required, high power lasers providing very short pulses (~100 fs) are used, so that peak intensity is high, but average power doesn’t damage the specimen. We have photon flux densities sufficiently high for multiple photons to arrive “simultaneously” (in s) at an excitable molecule (of cm 2 cross section) only at the focus point of a beam. The probability that a given fluorophore at the center of a focused beam absorbs a photon pair during a single pulse is

Advantages of multi-photon excitation With a single-photon source excitation occurs throughout the beam profile With a two-photon source excitation events are limited to the beam focus Focal point restriction of excitation automatically provides 3-dimensionally resolved submicron information Photodamage is restricted to the focal plane Not necessarily to refocus the fluorescence through an aperture –Simpler, more efficient optical detection design –Scattering in thick specimens degrades signal to a smaller extent UV absorbing molecules can be excited using practical visible/NIR wavelength ranges

Second Harmonic Generation (SHG) SHG can be thought off as the scattering equivalent of two-photon excited fluorescence The emitted photons are at exactly half of the wavelength of the incident radiation (as excitation  changes, emitted SHG signal also changes) The SHG signal is phase matched to the incident radiation and it is emitted in a highly directional fashion, which depends on the size, shape and refractive index of the scatterers. (fluorescence is incoherent and isotropic)

Instrumentation

Multi-photon imaging is the method of choice for looking at endogenous fluorescence in thick biological specimens Two-photon excited fluorescence (TPEF) is particularly useful in imaging of endogenous weak fluorescence Second harmonic generation (SHG) yields excellent intrinsic contrast for imaging of asymmetric molecules, such as collagen

4-Pi, two-photon fluorescence microscopy Combines localized excitation with coherent fluorescence detection to beat resolution limit Resolution achieved 80 nm Mitochondrial network of a live yeast cell Gugel et al. Biophys J 2004; 87: