16 th ICNCT June 14-19, 2014 Helsinki, Finland Design and simulation of an optimized photoconverter for e-linac based neutron source for BNCT research.

Slides:



Advertisements
Similar presentations
Giorgio Russo National Research Council, Institute of Bioimaging and Molecular Imaging (IBFM) Fondazione Istituto San Raffaele G. Giglio di Cefalù Istituto.
Advertisements

The LENS Facility at IUCF David V. Baxter Indiana University A. Bogdanov, J. M. Cameron, P. Chen (UIUC), V. P. Derenchuk, B. Jones (UIUC), H. Kaiser, C.
Nuclear Data in Radiation Protection Dosimetry 2011 Symposium on Nuclear Data Daiki SATOH Japan Atomic Energy Agency 1. Dosimetry calculations powered.
UNIVERSITA’ DEGLI STUDI DI PALERMO DIN DIPARTIMENTO DI INGEGNERIA NUCLEARE CHERNE th Workshop on European Collaboration for Higher Education and.
RapidArc plan verification using ArcCHECK™
Faiza Bourhaleb Dipartimento di fisica sperimentale
EMERALD1: A Systematic Study of Cross Section Library Based Discrepancies in LWR Criticality Calculations Jaakko Leppänen Technical Research Centre of.
Study of a DD compact neutron generator for BNCT
Esteban Fabián Boggio 1 Lucas Provenzano 2 Sara Gonzalez 2,3 Sara Gonzalez 2,3 Juan Manuel Longhino 1 1 Bariloche Atomic Center, Atomic Energy National.
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
Neutron background measurements at LNGS Gian Luca Raselli INFN - Pavia JRA1 meeting, Paris 14 Feb
E. Bavarnegin,Yaser Kasesaz, H. Khalafi
Design on Target and Moderator of X- band Compact Electron Linac Neutron Source for Short Pulsed Neutrons Kazuhiro Tagi.
Michele Togno ARDENT ESR 11 – 2D Ionization Chambers Array for Clinical Applications Michele Togno – ARDENT midterm review preparatory meeting, CERNJune,
ELBE Neutron Source IAEA TC Meeting “Nuclear Data for IFMIF”, FZ Karlsruhe, October 4-6, 2005 Klaus Seidel Technische Universität Dresden.
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Determination of gamma dose component in thermal column of Pavia Triga reactor by using alanine ESR detectors Saverio Altieri Department of Physics University.
16 th International Congress on Neutron Capture Therapy June 14-19, 2014 Helsinki, Finland Study of suitability of Fricke-gel-layer dosimeters for in-air.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
16 th International Congress on Neutron Capture Therapy June 14-19, Helsinki, Finland Improvement of a PGNAA Facility for BNCT in THOR C. K. Huang 1, H.
Radiation Processing Irradiation consists in exposing a product to ionizing radiation in order to preserve, modify or improve its characteristics. The.
VCI - V. Conti February, A TIME OF FLIGHT DETECTOR FOR THERMAL NEUTRONS FROM RADIOTHERAPY LINACS V. Conti, G.Bartesaghi, D.Bolognini, M.Prest,
Page  1 A new method to measure 10 B uptake in lung adenocarcinoma in hospital BNCT D. Bolognini, E.M. Donegani, A. Mattera, M. Prest, S. Hasan E. Capelli,
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Design and construction of BNCT irradiation
The Response of ESR Dosimeters in Thermal Neutron Fields
Med Phys 3A03/3AA1 Practical Health & Medical Physics Communications D.R. Chettle, with D.F. Moscu TA: Helen Moise.
Gamma-induced positron lifetime and age-momentum
N. Gubanova 1, V. Kanygin 2, A. Kichigin 3, S. Taskaev 4 1 Institute of Cytology and Genetics, Novosibirsk, Russia 2 Novosibirsk State Medical University,
Low Energy Neutron Interactions in Geant4 Jacek M. Holeczek Institute of Physics, University of Silesia, Katowice, Poland [Adam Konefał’s results also.
IRCC & Mauriziano Hospital & INFN & S Croce e Carle Hospital
Managed by UT-Battelle for the Department of Energy Residual Does Rate Analyses for the SNS Accelerator Facility I. Popova, J. Galambos HB2008 August 25-29,
Applications of Monte Carlo Code for a Gamma Resonance System Analysis L. Wielopolski, A. Hanson, I. Dioszegi, M. Todosow, Brookhaven National Laboratory,
ThEC13, Geneva, 28th-31st Oct., 2013 C. H. Pyeon, Kyoto Univ. 1 Cheolho Pyeon Research Reactor Institute, Kyoto University, Japan
The improvement of the energy resolution in epi-thermal region of Bonner sphere using boric acid solution moderator H. Ueda1, H. Tanaka2, Y. Sakurai2.
Experimental Studies of Spatial Distributions of Neutrons Produced by Set-ups with Thick Lead Target Irradiated by Relativistic Protons Vladimír Wagner.
M Asnal *, T Liamsuwan 2 and T Onjun 1 1 Sirindhorn International Institute of Technology, Thammasat University 2 Nuclear Research and Development Division,
A NEUTRON IRRADIATION DEVICE FOR THE TESTING OF MICROELECTRONIC COMPONENETS TO BE USED IN THE RADIATION ENVIRONMENT OF HIGH-ENERGY PARTICLE ACCELERATORS.
M. Štefánik *), P. Bém, M. Honusek, K. Katovský, M. Majerle, J. Novák, and E. Šimečková AER Working Group F – „Spent Fuel Transmutation“ and INPRO IAEA.
LOMONOSOV MOSCOW STATE UNIVERSITY, SKOBELTSYN INSTITUTE OF NUCLEAR PHYSICS Multi-particle photodisintegration of heavy nuclei A.N. Ermakov, B.S. Ishkhanov,
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Grup de Física de les Radiacions 24 th International Conference on Nuclear Tracks in Solids CALIBRATION OF THE UAB PADC BASED NEUTRON DOSEMETER Measurements.
IFMIF d-Li neutron source: Status of codes and nuclear data S.P. Simakov Institut für Reaktorsicherheit, Forschungszentrum Karlsruhe IEA Neutronics Meeting,
9 th session of the AER Working Group “f “ - Spent Fuel Transmutations Simulations of experimental “ADS” Mitja Majerle, Gael de Cargouet Nuclear Physics.
Photoneutron Distributions around 18 MV X-ray Radiotherapy Accelerators using Nuclear Track Detectors Fazal-ur-Rehman, H. Al-Ghamdi, M. I. Al-Jarallah.
4th International Summer School « Nuclear Physics Methods and Accelerators in Biology and Medicine » Monte-Carlo simulations : FLUKA vs. MCNPX Maxime ODEN.
Bremsstrahlung Example of conservation of energy Radiative energy loss by fast electron when slowed near nucleus Results in spectrum of energies from many.
The 14 MeV Frascati Neutron Generator (FNG)
Development of Cryogenic Moderators Using a Small Proton Accelerator Yoshiaki Kiyanagi*, Fujio Hiraga, Takashi Kamiyama, Akira Homma, Fumiyuki Fujita and.
BNCT, a binary radiotherapy at cellular level
MCS overview in radiation therapy
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
CONFIDENTIAL MATERIAL Michele Togno - II Annual ARDENT Meeting, Milan – October, 14 th D Ionization Chambers Array for Clinical Applications.
Boron Neutron Capture Therapy: tecnica e sorgenti
INSTITUTE OF NUCLEAR SCIENCE AND TECHNOLOGY
GEANT4 Simulations of a Beam Shaping Assembly Design and Optimization for Thermal/Epithermal Neutrons Vahagn Ivanyan  Yerevan Physics Institute, Armenia.
Beam quality correction factors for linear accelerator with and without flattening filter Damian Czarnecki1,3, Philip von Voigts-Rhetz1, Björn Poppe3,
BEAT_PRO Beam Tailoring and procedures optimization for clinical bnct
P. Buffa, S. Rizzo, E. Tomarchio
Very High Energy Electron for Radiotherapy Studies
Cross-section Measurements of (n,xn) Threshold Reactions
A Comparative Study of Biological Effects of VHEE, Protons and other Radiotherapy Modalities Kristina Small University of Manchester, Christie NHS Foundation.
Measurements of the 238U radiative capture cross section using C6D6
JOINT INSTITUTE FOR NUCLEAR RESEARCH
Design of A New Wide-dynamic-range Neutron Spectrometer for BNCT with Liquid Moderator and Absorber S. Tamaki1, I. Murata1 1. Division of Electrical,
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
Sheng Yang a, Yen-Wan Hsueh Liu b
Presentation transcript:

16 th ICNCT June 14-19, 2014 Helsinki, Finland Design and simulation of an optimized photoconverter for e-linac based neutron source for BNCT research E.Durisi 1,2, A.Zanini 2, G.Giannini 3,4,G.Vivaldo 1, K.Alikaniotis 1, V.Monti 1, O.Borla 5, F.Bragato 3 1 Dipartimento di Fisica, Università di Torino, Via P. Giuria 1, Torino, Itay 2 Istituto Nazionale di Fisica Nucleare Sez. di Torino, Via P. Giuria 1, Torino, Italy 3 Università di Trieste, Via Valerio 2, Trieste, Italy 4 Istituto Nazionale di Fisica Nucleare Sez. di Trieste, Via Valerio 2, Trieste, Italy 5 Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy

16 th ICNCT June 14-19, 2014 Helsinki, Finland Outline Goal of PSIHO project Summary of the previous results Project of a dedicated facility: linear accelerator and photoconverter Results in terms of free beam parameters and in-phantom dose evaluations Conclusions

16 th ICNCT June 14-19, 2014 Helsinki, Finland GOAL of the project Design a neutron source for research in BNCT coupling high energy linear accelerator 18MV - 25MV with a suitable photoconverter PSIHO project is devoted to design and manufacture an in-hospital BNCT facility FUTURE PSIHO: Photoneutron Source In HOspital INFN project (section of Torino and Trieste)

16 th ICNCT June 14-19, 2014 Helsinki, Finland Photoneutron production in LINAC Electrons ~20 MeV Linac Target X-ray emission by Bremsstrahlung Neutrons are produced by ( γ,n) reaction (photodisintegration) mainly on high Z material when E  > threshold energy reaction (W: 7.42MeV, Fe: 10.9MeV, Pb: 7.41 MeV) Varian 2300 CD 18MV MCNP Neutron plane Field 10x10 cm 2 Mean neutron energy 700keV <E n < 1 MeV W/Pb neutrons - Neutrons High Z material

16 th ICNCT June 14-19, 2014 Helsinki, Finland Photoconverter design The study of the photoconverter materials and geometries has been carried in order to: increase the photoneutron production; maximize the therapeutic neutron component of the beam (E < 10 keV); minimize the fast neutron component and  undesired dose. The main components of the photonconverter are: Final configuration Core Increase ( ,n) production (High Z elements: Pb, W) Moderator: Slow down neutron energy up to thermal/epithermal range, minimizing fast neutron component (Graphite, D 2 O, Polyethylene) Gamma shielding minimize gamma (Pb e Bi) Lead Graphite 60 cm Polyethylene, B 4 C, Lead Neutron reflector increase neutron flux (Graphite, Pb)

16 th ICNCT June 14-19, 2014 Helsinki, Finland PhoNeS “Bianco”prototype First in-hospital neutron source for BNCT trials Phones+Elekta precise 25MV  th = cm -2 s -1 ± 20% Summary of the previous results Transportable PhoNeS prototype closed cavity configuration Cavity: 20 x 20 x 5 cm 3 Thermal neutron field of suitable intensity and energy spectral distribution for BNCT research and experiments on cells and biological samples Irradiation time ~ 3hrs  ~ cm -2 GRAPHITE LEAD D2OD2O POLYETHYLENE Thermal neutrons (85%) (1.04±0.02) 10 7 cm -2 s -1 Epithermal neutrons (11%) (1.39±0.07)10 6 cm -2 s -1 Fast neutrons (4%) (4.8±0.3) 10 5 cm -2 s -1

16 th ICNCT June 14-19, 2014 Helsinki, Finland INFN Project of a dedicated facility for BNCT reasearch -Installation of LINAC Elekta Precise 18 MV (no longer in use in radiotherapy department) in the Physics Department of the University of Torino -modification of LINAC accelerator -construction of an optimized photoconverter -test

16 th ICNCT June 14-19, 2014 Helsinki, Finland A dedicated facility for BNCT reasearch Monte Carlo approach to optimize the photoconverter geometry - MCNP4B─GN (NEA-1733) - MCNP 5 - GEANT 4 Investigate possible modification of: - linac working parameters - linac accelerator head components

16 th ICNCT June 14-19, 2014 Helsinki, Finland Dedicated linear accelerator for BNCT research Elekta Precise 18MV Photon mode25 MV18 MV15 MV10 MV6 MV18 MV modified Dose rate (MU/min)400 Electron energy (MeV) T (  s) I (mA) (Hz) Power (W) K (x10 14 e - s -1 ) Elekta manufacturer provided Elekta Precise 18 MV modified: I = 50 mA;  = 200 Hz; T = 2.8  s Electrons rate = 1/1.602x x I x x T = e- s -1  Conversion factor cm 2 /e - cm 2 /s depends on LINAC duty cycle  MCNP : Average neutron fluence rate cross a surface (cm 2 /e - )

16 th ICNCT June 14-19, 2014 Helsinki, Finland Effect of the flattening filter on the photon beam inetensity Modification of Elekta Precise 18MV with FF Total fluence rate (3.727±0.005)10 11 cm -2 s -1 without FF Total fluence rate (8.967 ± 0.015)10 11 cm -2 s -1 Photon fluence rate increases ~2 times (from cm -2 s -1 to cm -2 s -1 )

16 th ICNCT June 14-19, 2014 Helsinki, Finland New PhoNes - open cavity configuration Lead Polyethylene Heavy water Graphyte Borate polyethylene Fluence rateWith FFWithout FF cm -2 s -1 % Hyperthermal1.51E+07±0.02E E+07±0.02E+0775 Fast4.83E+06±0.07E E+06±0.11E+0625

16 th ICNCT June 14-19, 2014 Helsinki, Finland Comparison MCNP5 - MCNP4B_GN MCNP4B-GN photoneutron production on high Z elements is implemented: - ( ,n) and ( ,2n) are included - evaporative and direct models are used. photoneutron production on low Z elements is implemented: - only ( ,n) reaction and direct model. MCNP5 cross section - endfbVII -mcplib04 -el03 MCNP 5 Photoneutron production on high and few low Z elements is implemented. - evaporative (Giant Dipole Resonance) and direct models (Quasi Deuteron) are used MCNP-GN cross section - endfbVI -mcplib02 -el1

16 th ICNCT June 14-19, 2014 Helsinki, Finland New PhoNes - closed cavity configuration Lead Polyethylene Heavy water Graphyte Borate polyethylene Fluence rateWith FFWithout FF cm -2 s -1 % Hyperthermal3.14E+07±0.03E E+07±0.05E+0781 Fast7.10E+06±0.11E E+07±0.02E+0719

16 th ICNCT June 14-19, 2014 Helsinki, Finland IAEA PhoNeS Bianco Without FF New PhoNes Closed cavity With FF New PhoNes Closed cavity Without FF  th+epith cm -2 s -1 > (5,17±0.05)10 7 (3.14±0.03) 10 7 (5.86±0.05)10 7 D  /  th+epi Gy cm 2 < (1.35±0.02) (3.41±0.08) (5.07±0.09) D f /  th+epi Gy cm 2 < (1.00±0.04) (2.99±0.11) (3.2±0.1) Calculated free beam parameters

16 th ICNCT June 14-19, 2014 Helsinki, Finland In phantom dose evaluations The anthropomorphic phantom “Jimmy” was designed and realized by INFN Sez. Torino, in collaboration with JRC Varese. Materials: polyethylene and plexiglas, with inserted human bone in correspondence of column. Cavities are placed in correspondence of critical organs and are suitable to allocate passive dosemeters such as bubble detectors, TLDs... Cross section of phantom realized with MCNP Organs composition from ICRU report 46 (International Commission on Radiation Measurements and Units, 1992) x y z

16 th ICNCT June 14-19, 2014 Helsinki, Finland In phantom dose evaluations The phantom is placed in front of the cavity. A left lung treatment is investigated. 3 irradiations are considered (A-P, P-A, LAT). The biological dose is calculated in all the organs. LAT P-A RBE  (w  ) RBE n (wn) 10 B (ppm) CBE (w B ) Left lung tumour 13,2763,8 Left lung healhty 13,2191,3 Other organs 13,2191,3 Biological dose = D W = w  D  + w n (D H + D N ) + w B D B

16 th ICNCT June 14-19, 2014 Helsinki, Finland In phantom dose evaluations LAT Treatment planning for left lung tumour with crossed photon beams. ELEKTA 6 MV (0°- 180°-270°)

16 th ICNCT June 14-19, 2014 Helsinki, Finland In phantom dose evaluations LAT

16 th ICNCT June 14-19, 2014 Helsinki, Finland The study of a new facility based on a linear accelerator devoted to BNCT research and a new photoconverter was carried out. A dedicated facility allows to modify LINAC working parameters and the accelerator head components in order to increase the photon production. Simulations demonstrated that without flattening filter the photon fluence rate useful for ( ,n) reaction increases of a factor 2. Different photoconverters were simulated. The configuration with closed cavity, suitable for the irradiation of biological samples, provides a neutron fluence rate (E < 10 keV) of (5.86±0.05)10 7 cm -2 s -1 The irradiation time is therefore reduced to ~ 30 min to get neutrons cm -2. The gamma dose is still high and needs to be further reduced as well as the fast neutron one. A preliminary evaluation of biological dose distribution in phantom was realized simulating a treatment to left lung with 3 crossed beams. Conclusions

16 th ICNCT June 14-19, 2014 Helsinki, Finland 20 Università degli Studi di Torino Università degli Studi di Trieste Università dell’ Insubria di Como Università degli Studi di Pavia ASO Ordine Mauriziano (Torino) AOU San Luigi – Orbassano (Torino) AOU San Giovanni Battista (Torino) ASO Sant’Anna (Como) Ospedale Maggiore (Trieste) ST. JOHANNS HOSPITAL Salisburgo (AUSTRIA) GIO’ MARCO s.p.a. MOGLIANO VENETO (Treviso) The project was financially supported by: Italian National Institute of Nuclear Physics Italian Ministery of Industry, Research and University CRT fundation Acknowledgments

16 th ICNCT June 14-19, 2014 Helsinki, Finland LAT Thank you!