“Stray Voltages and Public-Exposed Lighting Installations”

Slides:



Advertisements
Similar presentations
Bonding and Grounding What? Why? How?
Advertisements

The Electrical GuruTM Paul W. Abernathy,CME
Electrical Installation
Earthing PRESENTATION BY: Er. Satnam Singh Lecturer(Electrical engg.)
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Earthing systems, Harmonics Currents and GFP
Earthing systems, Harmonics Currents and GFP
imnot50 and suite4121 The form of protection provided by the insulation of live parts would be: Protection against direct contact.
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
EE4503 Electrical Systems Design
Inspection & Test Overview suite412.
30th Nov 2005Imnot50 Question 1 State the necessary action that should be taken by an inspector on discovering a damaged socket outlet with exposed live.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
“Equipment bonding jumpers: are they always necessary?” Massimo Mitolo, Senior Member, IEEE.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
Area of Study 2: Electricity
Vidhyadeep Institute Of Management & Technology, Anita, Kim Electronics & Communication Department Guided by Mr. Vicky Paperwala.
Electrical Safety Mark Gough Electrical Inspector Northern Specialist Group.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electricity at Work.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Installation Practice 2
Electrical Safety INSTRUCTOR’S NOTES:
Earthing system.
Electrical Installation 2
Electrical Safety INSTRUCTOR’S NOTES:
Grounding, bonding, and ground fault currents
Earthing configurations Minute Lectures Earthing or not? Is that the question? It is often thought that an electrical appliance can only be earthed or.
Basic Electricity.
CHAPTER 6 EARTHING SYSTEM.
Wiring and Grounding.
Introduction to switchgears
Ag. Mechanics for Beginning Teachers
Electrical Installation II1 Assessment of General Characteristics (Note: All the mentioned tables in this course refer to, unless otherwise specified,
Testing of Low Voltage Installations
Electrical Safety "Shocking Statistics“  There are approximately 290 accidental electrocutions each year.  An additional 800 people die in fires caused.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
PRESENTATION OF Earthing System
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Generation and Distribution of electrical energy Grade 8.
Ground Bond and Ground Continuity Testing
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
PROTECTION AGAINST INDIRECT CONTACT
Circuit Protection Unit 9.
Grounding And Safety Techniques Ms. Tahoora Qureshi, Asst. Professor
HIGH VOLTAGE ENGINEERING (HVE)
THREE-PHASE GROUND-FAULT BASICS
Effects of an Electric Current and Domestic Circuits
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Engineering Project Cable Management.
Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)
ELECTRICAL POWER-II Electrical engineering sixth semester
The Electric Circuit.
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Overcurrent Protection— Fuses and Circuit Breakers
EET 323 – Electrical System Design Lecture 9: Grounding
EE-4TH SEMESTER ESTIMATING AND COSTING.
Safety Meeting Topics Standby Generator Safety
Presentation transcript:

“Stray Voltages and Public-Exposed Lighting Installations” Massimo Mitolo, Ph.D. IEEE Senior Member

Outdoor lighting installations Lighting fixtures along with their supply circuits, including: transformers, breakers, reclosers, switches, manholes, and whatever is functional to the installation performance. All publicly exposed!

Stray Voltages “Stray”: Element or occurrence not desired in theory, but unavoidable in a practical realization. Term coined in the 1970s: Stray Voltages In Dairies “Elevated metal object-to-ground or neutral-to-ground voltages” Current, and not Voltage, is the proper criterion of shock intensity

Stray Currents Permanent current other than momentary fault current circulating over the earth objectionable and undesirable Concerns for pedestrians and their animals!

TT earthing system per IEC T= direct connection of one point of the power system to ground. T= direct electrical connection of exposed-conductive-parts to ground, independently of the grounding of any point of the power system Utility Customer

TT earthing system The intensity of the ground fault current is limited by the series resistance RL and RN of the grounds. RCD is crucial!

Drawbacks with the RCDs Nuisance trips e.g. transient (10 μs) overvoltages during thunderstorms RCD trips the breaker in 10-40 ms: it operates when the impulse has already expired. RCD with intentional tripping delay is allowed, better if with high immunity to disturbances.

RCD with automatic reclosure capability? Not required, so far, by IEC standards because of the risk of repetitive shock to persons due to a persistent fault. Professional Engineers must decide on an individual case basis!

TT Equivalent fault circuit Person’s body resistance: 788Ω @125V, 700 Ω @220 V, etc. VOLTAGE DIVIDER! Person’s resistance to ground in the absence of floor: 2ρ. Person assumed shoeless as per: IEC 60479-1; 1994-09, 3rd Ed., “Effects of current on human beings and livestock - Part 1: General aspects”. Persons in contact with the energized pole, and standing in its proximity, are in an area at a potential other than zero. This circumstance limits the source touch voltage VST!

Independently grounded poles in TT Systems What if the neutral conductor is faulted? the RCD is desensitized!

Independently grounded poles in TT Systems No, thank you!

TN-C-S Earthing System T= direct connection of one point to ground. S= protective function provided by a conductor separate from the grounded conductor N= direct electrical connection of the ECPs to the grounded point of the power system. C= neutral and protective functions combined in a single conductor

Stray current as a result of unbalanced loads: No-Fault Condition Stray current as a result of unbalanced loads: Permanent!

The fault current’s return path to the power-supply winding Fault Condition The fault current’s return path to the power-supply winding

TN-C-S Earthing systems  Ia is the current causing the automatic operation of the overcurrent protective device within the safe time ta Vph (V) Disconnecting time ta (s) 120 0.8 230 0.4 277 400 0.2 >400 0.1 DOSE!

Extraneous-conductive-part (EXCP) not forming part of the electrical system liable to introduce a “zero” potential (local/remote earth potential) or an arbitrary potential

Whole potential between the faulted pole and the fence Should we bond? EXCP EXCP Bonding Jumper between pole and fence (only if Extraneous-Conductive-Part) Drawback: Ground Potential Rises are tranferred!

Class II equipment Double insulated (or reinforced insulated) equipment: incorporates a supplementary insulation, in addition to the basic one. The two insulations are physically separated (and tested) they cannot be subject to the same deteriorating factors (e.g. temperature, contaminants, etc.) to the same degree.

Class II equipment It is an equivalent protection against indirect contacts if applied to the entire outdoor installation (i.e. light fixtures, conductors, splices, and terminal strip). According to IEC, class II equipment is not permitted to be grounded.  According to NEC, double insulated equipment is not required to be grounded.

Measuring stray voltages Persons are sensitive to currents, and not to voltages. Stray voltages, thus, cannot point out, per se, dangerous situations. The human body resistance RB is variable with the touch voltage. It is important to assess the capability of the stray voltage to impress a dangerous current and not the magnitude of the voltage itself. Touch-voltage must be measured with reference to a standard human body resistance value: 1 kΩ as per IEC

Is the faulted pole found? Poles’ enclosures are connected together. The presence of stray voltage at the pole under investigation does not necessarily mean a fault on it!

Conclusions Analysis of the fault-loops is crucial to understand the causes of stray voltages. TT and TN-C-S distribution systems have fault loops of different natures, the first one comprising the actual earth. Both distribution systems require an effective partnership between the protective device and the grounding system, in order to protect persons by automatic disconnection of supply. Class II installations are an efficient solution to protect persons from electrocution and preserve the continuity of the service, especially in areas at high pedestrian and/or vehicular circulation.

“Stray Voltages and Publicly Exposed Lighting Installations” References M. Mitolo, “On Outdoor Lighting Installations Grounding Systems”, IEEE-IAS “Industry Application Society 41st Annual Meeting”, Tampa, Fl, October 2006. IEC 60364-1; 2002-06, 2nd Edition, “Electrical installations of buildings”. M. Mitolo, “Protective bonding conductors: an IEC point of view”, I&CPS Technical Conference 2005, Saratoga Springs, NY, Proceedings. IEC 60479-1; 1994-09, 3rd Edition, “Effects of current on human beings and livestock - Part 1: General aspects”. IEC 60364-7-717; 1996-04, 1st Edition, “Electrical installations of buildings”, part 7. “Requirements for special installations or locations - Section 714: External lighting installations”. NFPA 70, National Electrical Code 2005, National Fire Protection Association, Quincy, Massachusetts. IEEE Std. 142-1991, “IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems”. British Standard BS 7671; 2001, 16th Edition “IEE Wiring Regulations”. “Stray Voltages, Concerns, Analysis and Mitigation”, NEETRAC Project, Number 00-092, September 2001.