NAFA Guide To Air Filtration

Slides:



Advertisements
Similar presentations
IAQ, FILTRATION AND THE CONSUMER MARKET Matthew Klein, PE-ME, MBA Indoor Air Quality Solutions, Inc.
Advertisements

Supercharging Chapter 8.
NANOSOLUTION FOR GAS TURBINES CARTRIDGE FILTER. CURRENT TECHNOLOGY.
The Concept of the Basic Liquid
Air powered car.
1 Hydroflow Filtration Systems F I L T R A T I O N S Y S T E M S HYDROFLOW SURFACE FILTRATION Versus DEPTH FILTRATION In Metalworking Fluids  SURFACE.
NFPA 96 and Building Code Requirements for Commercial Kitchen Hood Systems Presentation for the Sevier County Fire Code and Building Code Officials Presented.
CE 370 Filtration.
(IAQ). Introduction  A collective group of fine solid particles, aerosols, mist, smoke, dust, fibers and fumes are called Respirable particles  Particles.
SUPPLY DUCT SYSTEMS (Additional information. Read sections 18.4, 18.5, & 18.6) General –The supply duct system conveys conditioned air from an AHU to the.
Introduction Enthalpy Wheel
Air Filtration - Energy Savings Total Cost of Ownership ROGER STAMPER SALES MANAGER CAMFIL FARR.
Non-woven Abrasive Pads A plastic abrasive pad. Non-rusting and washable. Commonly called Scotch-Brite pads (3M brand name).
5. Filtration Fibrous filter High-efficiency glass fiber filter (a) 4150x (b) 800x. - Porosity: 70 to >99%. - Fiber size:
Impact of Water on Dust (Water Sprays) Suppression – prevent generation Capture – remove from air (water or mechanical means) Redirection – directed away.
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
Elements/Media t Types t Comparison t Which one do I use? t Construction t Testing.
Komatsu Genuine Hydraulic Filters
1 Residential Air Filtration. 2 Residential Issues Cleaner Air –Removal of Particulates –Removal of Odors Maintain Airflow Customers Change Filters.
Air Cleaning Devices. 2 Is An Air Cleaner Needed ?  Toxicity of materials discharged  Amount of material to be discharged  Value of material to be.
NAFA Guide to Air Filtration. Chapter 13 Owning and Operating Cost By Dirk ter Horst April 19 th, 2012 Another Approach…. Air Filter Comparison.
Everything you wanted to know about Air Filter Sales in Europe Christine Thieringer.
Indoor Firing Ranges Training Education Recommended Practices.
NAME OF STUDENTS Manali Kolekar Rupesh Jadhav Atish Mohite
Columbus Industries History
Mod. 2 Sub.5, MS 1 Air Filtration. Mod. 2 Sub.5, MS 2 Air filtration purposes To keep clean the environment To keep clean the environment for the people.
Principles of Carburetion
THE HYDROFLOW STAR FILTER
California Emerging Technologies Statewide Program Dynamic Air Quality Solutions December 10, 2012.
Particulate control techniques Gravity settling chamber Mechanical collectors Particulate wet scrubbers Electrostatic precipitators Fabric filters.
NAFA Guide To Air Filtration Chapter 2 Principles of Air Flow, Air Pressure And Air Filtration presented by the National Air Filtration Association Fourth.
Introduction to Energy Management. Week/Lesson 8 Air Cleaning Equipment.
V3 vs. v4 New Protocols for LEED Tommy Linstroth, Principal.
Basic Camera The Anatomy of a Camera.
NAFA Guide To Air Filtration Chapter 11 Airborne Molecular Contaminants presented by the National Air Filtration Association Fourth Edition.
NANOSOLUTION FOR HVAC COMPACT FILTER. PRESENT TECHNOLOGY AND USE OF HVAC OFFICES SUPERMARKETS PRODUCTION COMPANIES SWIMING POOLS AND SPORT HALLS HOSPITALSHOTELSAIRPORTS.
Separators Types of Dust Separator Cyclone Separator working & types Critical Parameters Advantages Disadvantages Applications maintenance.
Principles of Carburetion. Carburetors function The carburetor works on Bernoulli's principle: the faster air moves, the lower its static pressure, and.
CAR FILTERS Chapter 2. Types of car filters. 1. Types of car filters based on its shape:
. Government Engineering College Bharuch GROUP : 5 TAILOR HARDIK ( ) MORSIYA JENISH ( ) VANZA DIVYESH ( ) CHEMICAL DEPARTMENT.
Fresh-air helmet Version 1.0 BETA Fresh 90 and 90X Respiratory unit.
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Unit 36 Electric Motors, Drives, and Controls.
NAFA Guide To Air Filtration
PNEUMATICS Chapter 5 Secondary Air Treatment
Chapter 25 Section 3.
NAFA Guide To Air Filtration
NAFA Guide To Air Filtration
NAFA Guide To Air Filtration
NAFA Guide To Air Filtration
VENTILATION MDM NURUL AINI/QUS 3206.
Controlled Environments
NAFA Guide To Air Filtration
NAFA Guide To Air Filtration
Impingement and Extended Surface Filters
Phil Maybee For NAFA Annual Convention 2010
SEMINAR ON AIR CIRCULATION IN STENTERS
NAFA Guide To Air Filtration
Modern Devices: Chapter 5 – Cleanrooms,
Media Velocity Panel vs Extended Surface
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Hollinee Filtration.
NAFA Certified Technician “Technicians For Life”
ANSI/ASHRAE 52.2 A destructive test to measure minimum efficiency reporting value (MERV) Efficiency test aerosol is Potassium Chloride (KCl) particles,
NAFA Guide To Air Filtration
ISHAN PARYAVARAN PVT. LTD.
Looking for Shot Blasting Machine manufacturer in India
Nafa Tech Seminar Phoenix Arizona 2004
Presentation transcript:

NAFA Guide To Air Filtration Fourth Edition Chapter 3 Impingement Filters presented by the National Air Filtration Association

Impingement Filters Impingement- The process in which larger particles are removed from an air stream because of their (weight or size) inertia. Mechanical filters whose principal mechanism of dust capture is impingement. Particles in the airstream that cannot change direction because they are so large and heavy are captured by impingement.

Impingement Filters Most impingement filters are characterized by relatively high media velocities and by low pressure drops.

Impingement Filter Categories Panel Filters Washable Metal-Panel Filters Roll Filters Slide is self explanatory Lint Filters

Panel Filters Fixed-media air filters in which the face velocity and the media velocity are essentially the same. Most impingement filters are panel filters, that is, they have the same square foot of media as the fame in which they are held. For example, a 24 x 24 x 2 inch metal washable filter has how many square foot of face area? (answer 4) and hence the velocity of the air traveling through the filter media is traveling at the same velocity as the face velocity (4 square foot of media in the filter). This contrasted to extended surface pleat that has 12 square foot of media. Now we must divide the velocity by the square footage in order to get the media velocity. In this example, if our cfm is 2000, the panel filter face and media velocity would be how much? (500 fpm). The pleat would also have 500 fpm face velocity but would have only how much media velocity? (answer 167 - rounded).

Panel Filters Face velocity-the speed of the air as it approaches the filter face. Media velocity-the speed of the air as it moves through the filter media. Any questions on the difference between these two?

Panel Filters: Materials of Construction Metals Spun-glass fiber media Synthetic Fibers Foam

Metal Washable Filters Metal washable filters are normally used with heavy duty loading of large particles and are intended to be washed. Aluminum and steel are the most frequently used materials construction however, other materials are used for special applications such as bronze for ship-board use. Metal washable filters should be used with a non-petroleum/water soluable spray-on adhesive to increase their holding capacity. They also may have several layers of graduated density media in the pack.

Spun-glass media Used extensively in Impingement Filters Usually adhesive coated to improve retention Media density varies ¼” to 5” Can be used in pads or cardboard frames Spun-glass panel filters have been around since the early 1950’s. They were produced to meet the need for a throwaway filter that would capture large lint and dust particles in early non-fan powered HVAC systems. Even in the 2” industrial variety, they rarely achieve more than a MERV 4 efficiency and therefore, do not meet ANSI/ASHRAE Standard 62.1 & 62.2 requirements for commercial and residential facilities of MERV 6 minimum.

Synthetic Fibers Polyester- Most popular material – ring and link panels, pocket filters Also Polypropylene, Nylon or other synthetic (usually meant to be washed) Polyester is the most popular material for synthetic throwaway filters. Polypropylene and other materials are used for “passive electrostatic” filters that are washable. Adhesives are usually added to synthetic fibers to increase their ability to hold particles onto the fiber.

Synthetic Fibers Fiber weight is measured in denier. As a rule smaller denier fibers will do a better job capturing small dust particles. Dual denier media is commonly used. It incorporates a larger fiber on the air entry side and a smaller fiber on the exit side. Synthetic fiber size is expressed in “denier” even though this is a measurement of weight, not size. For example, a 40 denier fiber is 66 µm in size while a 6 denier fiber 25 µm. Progressive density panels utilize a larger fiber on the air entry side and small fibers on the air exit side. Needling is also technique used with synthetic fibers to cause the fibers to become closer in the media.

Characteristics of Synthetic Fiber Media Fiber distribution consistency is the most important consideration when making synthetic media. Tackifiers are commonly applied to the air exit side of some synthetic medias to prevent dust migration. Electrostatic charge is present in some types of synthetic media to aid in particle capture.

Foam Usually polyurethane Classified by pore size The more pores per inch (PPI) the higher the efficiency Can be washed and reused Slide is self-explanatory

Impingement Filter Media Performance Determined from independent filter testing ASHRAE standard 52.1 (now obsolete) ASHRAE standard 52.2 (MERV) Although ANSI/ASHRAE 52.1 is still around as a standard, there are almost no labs doing this testing. ANSI/ASHRAE 52.2 has not yet incorporated the dust loading step from 52.1 into 52.2. Since filters such as metal washable and fiberglass are MERV 4 or less, it is really too expensive to have these filters tested just to let the consumer know they are low efficiency. Above MERV 4, 52.2 testing protocol is used.

Method of Renewal Filter banks using panel filters are renewed by washing or replacing dirty filter media. The use of disposable materials has become the predominant method of renewal.

Filter Holding Systems There are many different types of filter holding systems in use. Filter pad holding frames and side access housings are shown here. For other types of holding devices and systems, see the Installation, Operation and Maintenance of Air Filtration Systems text produced by NAFA.

Roll Filters Devices in which clean filter media is unrolled at one end,exposed to a dirty air stream, and advanced at intervals to keep the pressure drop through the exposed air stream within a desired operating range. Prone to many mechanical problems, automatic roll filters are an old technology that is infrequently specified today, yet many of these remain in service.

Roll Filters: Media Advance and Control A motor driven system. Manually operated chain drive. Can be controlled by an adjustable timer.

Roll Filter Media Fiberglass roll (infrequent) Synthetic fiber rolls

Lint Filters Use the automatic roll filter principle. Filter material Glass media with spun-bond backing Thin 1,2, or 3 ply cellulose media

Grease Filters Devices installed in kitchen range hoods to prevent the accumulation of grease in hood exhaust ducts. Usually made of steel or aluminum Grease filters do not aid in smoke removal. They can be washed. Must meet NFPA Std. 96 Grease filters are installed over range hoods. The only legal filter that can be now be used in commercial applications is the baffle-type filter, although many metal mesh grease filters may still be in use as they are grandfathered. The National Fire Prevention Association (NFPA) Standard 96 and tested under UL 1046.

Sample Questions The velocity of the air through any one square foot of media in an extended surface filter is called? Media Velocity Having larger fibers on the air entering side and smaller fibers on the air exit side is called? Graduated density

Thank you. Other Questions