Lesson 15 Continue looking at data collection methods Look at film, serial diffractometers and area detectors.

Slides:



Advertisements
Similar presentations
24.6 Diffraction Huygen’s principle requires that the waves spread out after they pass through slits This spreading out of light from its initial line.
Advertisements

Reciprocal Space Learning outcomes
Charge Couple Devices Charge Couple Devices, or CCDs operate in the charge domain, rather than the current domain, which speeds up their response time.
Digital Imaging with Charge- coupled devices (CCDs)
Area Detectors Like film can detect position Like scintillation detector can measure intensity With modern computers can assign hkl from unaligned crystal.
USE OF GEANT4 FOR LHCB RICH SIMULATION S. Easo, RAL, LHCB AND ITS RICH DETECTORS. TESTBEAM DATA FOR LHCB-RICH. OVERVIEW OF GEANT4 SIMULATION.
What is diffraction? Diffraction – the spreading out of waves as they encounter a barrier.
1. Detector 2. Crystal diffraction conditions
Planes in Lattices and Miller Indices
Lesson 15 Continue looking at data collection methods Look at film, serial diffractometers and area detectors.
Visit to KP 0.9m, Nov 13, Wed Van leavingTOCC at 4 PM. Bring a warm jacket! We will eat dinner in astronomer’s cafeteria when you arrive, then go directly.
X-Ray Crystallography The most important technique for mineralogy The most important technique for mineralogy Direct measurement of atomic arrangement.
CHAPTER 2 : CRYSTAL DIFFRACTION AND PG Govt College for Girls
PS Finish Light Color Uses of Electromagnetic spectrum.
Solid State Physics 2. X-ray Diffraction 4/15/2017.
Charles Campana Bruker Nonius
(X-Ray Crystallography) X-RAY DIFFRACTION. I. X-Ray Diffraction  Uses X-Rays to identify the arrangement of atoms, molecules, or ions within a crystalline.
Scanning Electron Microscope د. عمر عبد القادر.
Charles Campana Bruker AXS Inc.
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
Ch 25 1 Chapter 25 Optical Instruments © 2006, B.J. Lieb Some figures electronically reproduced by permission of Pearson Education, Inc., Upper Saddle.
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
How the Camera Works ( both film and digital )
Optical Mineralogy Technique utilizing interaction of polarized light with minerals Uses a polarizing microscope Oils - Grain mounts Thin sections – rocks.
Polarization Polarization is a characteristic of all transverse waves.
Detecting Electrons: CCD vs Film Practical CryoEM Course July 26, 2005 Christopher Booth.
Chapter 7 X-Ray diffraction. Contents Basic concepts and definitions Basic concepts and definitions Waves and X-rays Waves and X-rays Crystal structure.
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
Lesson 5 Conditioning the x-ray beam
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 25 Physics, 4 th Edition James S. Walker.
The four-circle single crystal diffractometer.
Comparing Regular Film to Digital Photography
X-ray structure determination For determination of the crystal or molecular structure you need: a crystalline sample (powder or single crystal) an adequate.
Lesson 16 Preliminary Steps to Data Collection While there are many types of equipment out there our discussions will be directed at area detectors and.
Photography in Education TECH2113 Dr. Alaa Sadik Department of Instructional & Learning Technologies
Lesson 14 Growing Crystals Collecting Data. Use Systematic Absences By using the systematic absences we can assign the possible space groups. Frequently.
Twinning Non-merohedral twinning Merohedral twinning.
Understanding typical users for this instrument Graduate studentGraduate student –not an X-ray expert but wants to make a spatially resolved measurement;
X-Ray Diffraction Dr. T. Ramlochan March 2010.
Diffraction Basics Coherent scattering around atomic scattering centers occurs when x-rays interact with material In materials with a crystalline structure,
Lesson 8 Diffraction by an atom Atomic Displacement Parameters Low Temperature Data Collection.
Lesson 14 Finish Discussion of Symmetry and Reciprocal Space
Lesson 16 CCD Detectors Visit the Lab. Charged Coupled Device The ccd is essentially a digital camera To keep noise down it is cooled It is almost realtime.
Beauty, Form and Function: An Exploration of Symmetry Asset No. 36 Lecture III-9 Laboratory Studies of Crystal Symmetry PART III Symmetry in Crystals.
Assessing Single Crystal Diamond Quality
Lesson 8 Diffraction by an atom Atomic Displacement Parameters.
Lesson 12—Working with Space Groups
Cameras. Question: If you’re building a camera and want to make a larger image (a telephoto lens) you should: 1.increase the diameter of the lens 2.decrease.
1 Data Acquisition What choices need to be made?.
Sounds of Old Technology IB Assessment Statements Topic 14.2., Data Capture and Digital Imaging Using Charge-Coupled Devices (CCDs) Define capacitance.
Lesson 13 How the reciprocal cell appears in reciprocal space. How the non-translational symmetry elements appear in real space How translational symmetry.
Lesson 13 How the reciprocal cell appears in reciprocal space. How the non-translational symmetry elements appear in real space How translational symmetry.
X-ray diffraction and minerals. Is this mineral crystalline?
Chapter 25 Electromagnetic Waves. Units of Chapter 25 The Production of Electromagnetic Waves The Propagation of Electromagnetic Waves The Electromagnetic.
Table of Contents Light and Color Reflection and Mirrors
Charge-Coupled Devices Astrophysics Lesson 5. Learning Objectives Describe and explain the structure and operation of the charge coupled device State.
The Camera. Photography is all about how light interacts with film and with paper. Cameras are designed to control the amount of light that reaches film.
Basic Crystallography for X-ray Diffraction Earle Ryba.
L 33 Light and Optics [4] Measurements of the speed of light  The bending of light – refraction  Total internal reflection  Dispersion Dispersion 
What is the interaction between x-rays and electrons Since x-rays are electromagnetic radiation they interact with atoms like any other radiation. Transmission—pass.
Crystallography : How do you do? From Diffraction to structure…. Normally one would use a microscope to view very small objects. If we use a light microscope.
Digital Image -M.V.Ramachandranwww.youtube.com/postmanchandru
Cont. Proteomics Structural Genomics Describes the experimental and analytical techniques that are used to determine the structure of proteins and RNA.
(Chapter 7) CHEM–E5225 Electron microscopy
1. Detector 2. Crystal diffraction conditions
CHARACTERIZATION OF THE STRUCTURE OF SOLIDS
Imaging Characteristics
Chapter 1.2 Electron Microscopy.
X-ray Neutron Electron
Computed Tomography (C.T)
Presentation transcript:

Lesson 15 Continue looking at data collection methods Look at film, serial diffractometers and area detectors.

Polarizing Microscope

General Position

Interference Colors

Extinction

Some Comments on Extinction Cubic crystals are isotropic and hence always dark! Hexagonal, trigonal and tetragonal crystals have an isotropic axis (c). When looked at down that axis the crystals will always be dark In triclinic and most faces in monoclinic crystals the extinction directions may be a function of wavelength. Instead of going black they will get dark blue then go dark red or vice versa. This is ok Some crystals change colors under one polarizer—dichroism.

Selecting a Crystal It is worth spending some time with the microscope to get the best crystal. Make sure the crystal is representative of the batch. Size is not as important as quality Remember— The quality of the final structure depends almost entirely on the quality of the crystal studied!

Crystal Mounting Crystals are typically mounted on a glass or quartz fiber (at Purdue I use quartz). Since these materials are not crystalline they do not diffract but they can scatter the beam. Crystals can be glued to the fiber with epoxy, super glue, or thermal glue for room temperature work. For low temperature work grease (Apeazon H) can be used.

Goniometer Head

Magnetic Caps

Film Methods

Rotation Photograph

Weissenberg Photos

Problems Must align about a real axis Alignment is fairly fast. Exposure takes days. Picture is hard to read. Film is curved so Polaroid cannot be used

How to get data? Must determine the intensity of the spots. To do this must compare the intensities to some scale. To expand the cell the camera holds six films. The front one is used for weak reflections while the last one is used for strong reflections The six films are scaled by common spots. How do you determine standard uncertainty? Very tedious and inexact.

Using Film Very low background –can take very long exposures Fairly sensitive to radiation Covers a wide area. Obviously slow to expose and very tedious to measure the intensities off of. No one uses anymore—in fact it is hard to find good quality film.

Speeding it Up The biggest problem with film is obtaining intensity data. Can use something like Geiger counters or scintillation detectors to count the radiation. Since these detectors have no spatial descrimination need to only allow a small area to reach the detector Must move the crystal precisely so the scattered wave lands on the detector.

Serial Diffractometer The result is the serial diffractometer. This is a very precise instrument that allows one to position the crystal in nearly any position It consists of 4 movable angles that intersect to less than 0.01mm.

Eulerian Cradle

Four Angles Phi—rotates the goiniometer head Chi –rotates the image around the beam Omega—used to make things more convenient Two Theta—the detector They are called the Eulerian Angles.

Problems Hard to keep in alignment Hard to move phi as it rotates around chi. The chi circle is closed at the top making it harder to bring in low temperature device. The chi circle will run into either the beam or the detector limiting settings.

Kappa Geometry

Can convert from kappa to Eulerian angles Open on top Mechanically much simpler Cannot reach chi angles above 110°

Using Serial Diffractometers Must know where the spots are so they can be collected. Must index the crystal before starting data collection.  From previous photos  From Polaroid photos taken on the diffractometer  From random searches. Must center the spots to determine the best values.

Orientation Matrix The key to automated data collection is the orientation matrix. This is the three reciprocal vectors projected on some Cartesian coordinate system of the instrument. Thus the length of each column is a*, b*, and c* The angle between column 1 and 2 is γ* etc.

Eulerian Cradle

Using the Orientation Matrix

Problems with Serial Diffractometers Still slow. Can collect maybe 1500 reflections a day. A typical data set takes about a week to collect. The detector is fairly noisy and therefore very long collection times are impossible as the signal does not become larger than the noise. Since only a small amount of space is observed frequently get incorrect unit cells or data that will not index.

Area Detectors. Looking for electronic film. Can determine the hkl from location and intensity by pixel intensities. Since an area is detected at one time can collect many data at once. Several Approaches.

Image Plates This is a material that emits vissible light when hit by a laser in proportion to how much x-ray exposure it encounters. Very low noise and very large dynamic range. Not a realtime device. Mainly used in macromolecular work.

Ragaku R-axis

Small Molecule Spider

Charged Coupled Device The ccd is essentially a digital camera To keep noise down it is cooled It is almost realtime. Does not have as low a noise level as image plate but is much better than scintillation detector. Does not detect x-rays but light emitted by a phosphor.

Kappa CCD

KappaCCD Specs

Newer Developments Very large CCD chips that do not need taper. These are 16 Mega pixel chips. Much more sensitive which is improved signal to noise (over 200 electrons/photon)‏ Read out is faster.

The X-ray Lab FR571 Rotating Anode Generator producing a 0.1X1.0 mm beam. A Nonius KappaCCD Software:  Nonius Collect Package  EvalCCD  Denzo