PRESENTED TO THE IEEE LONG ISLAND CONSULTANT’S NETWORK

Slides:



Advertisements
Similar presentations
POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
Advertisements

04/ Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power.
Grid Connect Inverters NUER 19
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
QUALITY AND TECHNOLOGY
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
Variable Frequency Drives VFD Basics
The X-Ray Circuit.
1. Output signal alternates between on and off within specified period Controls power received by a device The voltage seen by the load is directly proportional.
Surge Protection: Technical Background & Basics. 2 Surge Protection – Agenda Introduction AC Power Basics Power Quality Scope Voltage Transients & Disturbances.
Introduction to ElectroFlow TM System Dhaka, March 8, 2003 Mahmuduzzaman Khan Green Power Canada.
Computer Maintenance Power Quality and Protection Copyright © Texas Education Agency, All rights reserved. 1.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Lecture 1: Safety and Protection. 1. A robot may not injure a human being or, through inaction, allow a human being to come to harm. 2. A robot must obey.
Vex 1.0 © 2006 Carnegie Mellon Robotics Academy Inc. Test Bed Assembly.
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
1 Design and Documentation Honolulu Community College Cisco Academy Training Center Semester 1 Version
© 2011 Ericson Manufacturing, Willoughby, Ohio
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
POWER SUPPILES LECTURE 20.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
How PC Power Supplies Work If there is any one component that is absolutely vital to the operation of a computer, it is the power supply. Without it, a.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
Power Electronics and Drives (Version ) Dr. Zainal Salam, UTM-JB 1 Chapter 3 DC to DC CONVERTER (CHOPPER) General Buck converter Boost converter.
Power Quality Understanding Effective Solutions Presented by YOUR NAME HERE.
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Technician License Course Chapter 5 Amateur Radio Equipment Lesson Plan Module 12: Power Supplies and Batteries & RF Interference (RFI)
Uninterruptible Power Systems
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
BLACKOUT POWER OUTAGE By Masih Madayeni Class 3/6 English Presentation.
PHY 202 (Blum)1 More basic electricity Non-Ideal meters, Power, Power supplies.
POWER QUALITY.
Lecture # 12&13 SWITCHING-MODE POWER SUPPLIES
Chapter 11 Bruce Gaffield Randy Binns Scott Thrush Kristi Partney Edited by Richard Goldman.
© 2001 POWERVAR, Inc. Your Logo. © 2001 POWERVAR, Inc. Your Logo POWER VIRUSES Preventing Electronic Influenza.
8-1 School of Electrical Systems Engineering ABD RAHIM 2008 EET421 Power Electronic Drives - DC to AC converter / Inverter Abdul Rahim Abdul Razak.
1 POWER QUALITY -- Bhanu Bhushan -- April, Simple examples around us : Ceiling fan regulators Tube lights Lap-tops & peripherals Domestic inverters.
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
© 2003 Eaton Corporation. All rights reserved. Understanding Harmonics Richard Molloy Technology Sales Manager, Power Quality.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
EMT212 – Analog Electronic II
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
POWER FLUCTUATIONS Computer Systems. Power Fluctuations Voltage is the force that moves electrons through a circuit Unsteady voltages are called power.
PHY 202 (Blum)1 More basic electricity Non-Ideal meters, Kirchhoff’s rules, Power, Power supplies.
Presented by : GROUP 1 Associates: Ajeet Kumar Pooja Raikar Sangamesha J M Utkarsh Kumar Viresh Mathad.
Technician License Course Chapter 3 Operating Station Equipment Power Supplies and Batteries Handheld Transceivers RF Interference (RFI)
Copyright© 2005 Avaya Inc. All rights reserved Avaya UPS Training powerware.com/avaya.
SMJE 2103 Power Quality, Reliability and Availability.
A Solar Inverter. Introduction A Solar Inverter  The main aim of this project is to use solar energy for household loads using.
Switch Mode Power Supply(SMPS) BY: Arijit Acharya NETAJI SUBHASH ENGINEERING COLLEGE M.tech(P.S.) Roll No - 1.
Power supply.
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
J.PRAKASH.  The term power quality means different things to different people.  Power quality is the interaction of electronic equipment within the.
A+ Computer Repair Lesson 9 Problems Causing Power Events.
Power Quality Issues Power Electronics Group.
Chapter 6: Voltage Regulator
(345) (345)
Prepared By: Theo Laughner, PE
A Solar Inverter.
Introduction to Global AC Power
Dr. Unnikrishnan P.C. Professor, EEE
Mobile Networks Power Systems Training & Courses
Chapter 7 System Protection
UNIT-8 INVERTERS 11/27/2018.
Amplifiers Classes Electronics-II
Amplifiers Classes Electronics-II
Presentation transcript:

PRESENTED TO THE IEEE LONG ISLAND CONSULTANT’S NETWORK UNINTERRUPTIBLE POWER SUPPLIES JOHN LIGUORI CONSULTING ENGINEER MSEE, PE PRESENTED TO THE IEEE LONG ISLAND CONSULTANT’S NETWORK 9/6/06

UNINTERRUPTIBLE POWER SUPPLIES THIS PRESENTATION IS FOR INFORMATIONAL AND EDUCATIONAL PURPOSES ONLY. IT DOES NOT CONTAIN ALL INFORMATION REQUIRED, AND IS NOT INTENDED TO BE USED FOR THE SPECIFICATION OR DESIGN OF UNINTERRUPTIBLE POWER SUPPLIES (UPS) OR UPS SYSTEMS.

UNINTERRUPTIBLE POWER SUPPLIES OUTLINE INTRODUCTION POWER DISTURBANCES UNINTERRUPTIBLE POWER SUPPLIES GENERAL DISCUSSION SUMMARY REFERENCES QUESTIONS

INTRODUCTION PURPOSE WHAT IS AN UNINTERRUPTIBLE POWER SUPPLY? WHY USE A UPS?

PURPOSE THE PURPOSE OF THIS PRESENTATION IS TO DISCUSS THE DIFFERENT TYPES OF UNINTERRUPTIBLE POWER SUPPLIES AVAILABLE, WHAT THE UPS PROTECTS AGAINST, THE COMPONENTS OF A UPS, AND ISSUES REGARDING SELECTION AND SIZING. THE DIFFERENT TYPES AND CAUSES OF POWER DISTURBANCES ARE DISCUSSED, AS WELL AS WHAT THE POWER UTILITY, THE ORIGINAL EQUIPMENT MANUFACTURER, AND YOU, CAN DO TO MINIMIZE THEIR EFFECT.

WHAT IS AN UNINTERRUPTIBLE POWER SUPPLY? AN UNINTERRUPTIBLE POWER SUPPLY (UPS) IS A DEVICE THAT HAS AN ALTERNATE SOURCE OF ENERGY THAT CAN PROVIDE POWER WHEN THE PRIMARY POWER SOURCE IS TEMPORARILY DISABLED THE SWITCHOVER TIME MUST BE SMALL ENOUGH TO NOT CAUSE A DISRUPTION IN THE OPERATION OF THE LOADS

WHY USE A UPS? PROTECTS AGAINST MULTIPLE TYPES OF POWER DISTURBANCES ONLY DEVICE THAT PROTECTS AGAINST AN OUTAGE OFFERS PROTECTION AGAINST EQUIPMENT NOT OPERATING PROPERLY COMPUTER AND EQUIPMENT DAMAGE DATA LOSS TIME AND EXPENSE TO RECOVER BACK TO WHERE YOU WERE, IF EVEN POSSIBLE

POWER DISTURBANCES CAUSES TYPES DURATION RESULTING PROBLEMS COMMENTS WHAT THE POWER UTILITY CAN DO WHAT THE ORIGINAL EQUIPMENT MANUFACTURER (OEM) CAN DO WHAT YOU CAN DO PROTECTIVE DEVICES

CAUSES OF POWER DISTURBANCES STORM ACTIVITY – LIGHTNING, WIND, ICE OBJECTS COMING IN CONTACT WITH POWER LINE AND TRIPPING BREAKER – TREE BRANCHES, ANIMALS, OTHER UTILITY FAULT CLEARING CONSTRUCTION ACTIVITY ACCIDENTS – MOTOR VEHICLE, OTHER EQUIPMENT FAILURE OVERLOADING LOAD SWITCHING NON-LINEAR LOADS POOR GROUNDING ESD

TYPES OF POWER DISTURBANCES INTERRUPTION SAG, UNDER VOLTAGE SURGE, OVER VOLTAGE VOLTAGE FLUCTUATION FREQUENCY VARIATION SPIKES / TRANSIENTS IMPULSIVE OSCILLATORY WAVEFORM DISTORTION DC OFFSET HARMONICS INTERHARMONICS NOTCHING NOISE VOLTAGE IMBALANCE

DURATION OF POWER DISTURBANCES INSTANTANEOUS - ½ CYCLE (8 1/3 ms) OR LESS MOMENTARY - ½ CYCLE TO 3 SEC TEMPORARY - 3 SEC TO 1 MIN SUSTAINED - GREATER THAN 1 MINUTE

CLASSIFICATION OF PROBLEMS RESULTING FROM POWER DISTURBANCES DISRUPTIVE EQUIPMENT DOES NOT OPERATE AS INTENDED DISSIPATIVE EQUIPMENT EXPERIENCES REPEATED STRESSES THAT LEAD TO FAILURE LATER FOR NO APPARENT REASON DESTRUCTIVE EQUIPMENT FAILS AT THE INSTANT THE DISTURBANCE OCCURS

PROBLEMS RESULTING FROM POWER DISTURBANCES DATA ERRORS DATA LOSS BLOWN FUSES TRIPPED BREAKERS INTERFERENCE WITH CONTROL OF LOADS OVERLOADED NEUTRAL CONDUCTORS MOTORS HEATING SPEED VARIATION STALLING AUDIBLE NOISE VIBRATION TRANSFORMERS

POWER DISTURBANCES - COMMENTS NOT ONLY IS MODERN EQUIPMENT MORE SUSCEPTIBLE TO POWER DISTURBANCES, BUT THE EQUIPMENT ITSELF GENERATES MORE DISTURBANCES ALL LOADS, FROM LARGE POWERFULL MOTORS AND INDUSTRIAL EQUIPMENT TO SMALL, SENSITIVE ELECTRONIC COMPONENTS, ARE CONNECTED TO THE SAME POWER GRID

WHAT THE POWER UTILITY CAN DO TO MINIMIZE THE EFFECT OF POWER DISTURBANCES INSTALL STORM RESISTANT WIRING USE INFRA RED SCANNING TO DETECT WEAK SPOTS IN POWER LINES INSTALL REMOTE CONTROLLED RADIO SWITCHES TO RESTORE POWER QUICKLY CLEAR TREE LIMBS AWAY FROM POWER LINES

WHAT THE OEM CAN DO TO MINIMIZE THE EFFECT OF POWER DISTURBANCES BUILD EQUIPMENT CONTAINING ONE OR MORE INTERNAL PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES LINE FILTERS ISOLATION TRANSFORMER BATTERY OR CAPACITOR BACK UP TO INCREASE RIDE THROUGH TIME

WHAT YOU CAN DO TO MINIMIZE THE EFFECT OF POWER DISTURBANCES BUY EQUIPMENT THAT HAS INTERNAL PROTECTIVE DEVICES FOR EXAMPLE, BATTERY BACK UP FOR ANY APPLIANCE THAT CONTAINS A CLOCK USE ONE OR MORE EXTERNAL PROTECTIVE DEVICES SURGE PROTECTORS LINE FILTERS ISOLATION TRANSFORMER VOLTAGE REGULATING LINE CONDITIONER UPS

PROTECTIVE DEVICES OTHER THAN UPS SURGE PROTECTIVE DEVICES – SPD’S PROTECTS AGAINST SPIKES OF LIMITED ENERGY METAL OXIDE VARISTORS – MOV DIODES GAS TUBES LCR FILTERS HYBRIDS LINE FILTERS FILTERS OUT HARMONICS, TRANSIENTS AND NOISE ISOLATION TRANSFORMER ELIMINATES DC OFFSET AND NOISE VOLTAGE REGULATING LINE CONDITIONER AUTOMATICALLY ADJUSTS FOR UNDER AND OVER VOLTAGES CONSTANT VOLTAGE TRANSFORMER - CVT MOTORIZED VARIAC

POWER DISTURBANCES AND PROTECTIVE DEVICES

UPS ARCHITECTURES WAVEFORMS INVERTER TECHNOLOGY COMPONENTS SWITCHOVER TIME ADVANTAGES / DIS-ADVANTAGES SIZING BATTERY SAFETY

UPS ARCHITECTURES LINE INTERACTIVE ON-LINE

BLOCK DIAGRAM LINE INTERACTIVE UPS AUTOMATIC SWITCH CRITICAL LOAD (AC) AC SUPPLY BATTERY CHARGER INVERTER DC TO AC BATTERY AC FAIL

BLOCK DIAGRAM ON-LINE UPS AUTOMATIC SWITCH CRITICAL LOAD (AC) AC SUPPLY CONVERTER AC TO DC INVERTER DC TO AC BATTERY INVERTER FAIL

BLOCK DIAGRAM LAPTOP COMPUTER POWER SUPPLY CRITICAL LOAD (DC) AC SUPPLY CONVERTER AC TO DC CONVERTER DC TO DC BATTERY

UPS WAVEFORMS TRUE SINEWAVE MODIFIED SINEWAVE SQUARE WAVE

UPS WAVEFORMS

INVERTER TECHNOLOGY FOR TRUE SINEWAVE PULSE WIDTH MODULATION - PWM LINEAR AMPLIFIER RESONANT INVERTER

BLOCK DIAGRAM PWM INVERTER DC POWER CRITICAL LOAD (AC) HIGH FREQUENCY GENERATOR PULSE WIDTH MODULATOR BASE / GATE DRIVE TRANSISTOR BRIDGE TRANSFORMER FILTER REFERENCE SINEWAVE GENERATOR COMPARISON AMPLIFIER

BLOCK DIAGRAM LINEAR AMPLIFER INVERTER DC POWER CRITICAL LOAD (AC) SINEWAVE OSCILLATOR TRANSFORMER OSCILLATOR AMPLIFIER COMPARISON AMPLIFIER POWER AMPLIFIER

BLOCK DIAGRAM RESONANT INVERTER DC POWER CRITICAL LOAD (AC) SQUARE WAVE GENERATOR SWITCH DRIVE TRANSISTOR SWITCHES TRANSFORMER LC RESONANT TANK FILTER (OR FERRORESONANT)

UPS COMPONENTS CONVERTER - AC TO DC BATTERY INVERTER – DC TO AC SPD - PROTECTS AGAINST SPIKES AND TRANSIENTS BATTERY STORED ENERGY DEVICE - PROTECTS AGAINST INTERRUPTIONS INVERTER – DC TO AC WAVEFORM SYNTHESIS – PROTECTS AGAINST DC OFFSET AND INTERHARMONICS FILTER – PROTECTS AGAINST HARMONICS, NOTCHING AND NOISE VOLTAGE REGULATOR – PROTECTS AGAINST SAGS, SURGES AND FLUCTUATIONS MONITOR AND CONTROL HARDWARE / SOFTWARE

SWITCHOVER TIME A TYPICAL SWITCHOVER TIME 2 – 4 ms ONE QUARTER CYCLE OR LESS FOR SOME EQUIPMENT THIS IS NOT TOLERABLE

ADVANTAGES / DIS-ADVANTAGES OF THE DIFFERENT UPS ARCHITECTURES LINE INTERACTIVE ADVANTAGES AC TO DC CONVERTER / BATTERY CHARGER DOES NOT HAVE TO PROVIDE FULL LOAD POWER (POTENTIALLY CHEAPER) LESS STRESS ON DC TO AC INVERTER SINCE IT RUNS AT NO LOAD UNTIL UPS SWITCHES TO BATTERY POWER (POTENTIALLY CHEAPER) ON-LINE ADVANTAGES ZERO SWITCHOVER TIME FROM MAIN LINE TO BATTERY POWER ALWAYS ISOLATED FROM POWER DISTURBANCES ON THE MAIN LINE

SIZING THE UPS EQUIPMENT RATINGS FOR LOADS OBTAIN RATINGS FROM NAMEPLATE OR SPEC SHEET ENERGY USAGE MAY BE SPECIFIED IN VOLT AMPS (VA) OR WATTS (W) AND IN VALUES THAT ARE EITHER MAXIMUM OR NOMINAL (VA) AND (W) ARE RELATED VIA THE POWER FACTOR TOTAL UPS LOAD MUST NOT EXCEED THE UPS VOLT AMP (VA) RATING TOTAL UPS LOAD MUST NOT EXCEED THE UPS WATT (W) RATING OVERSIZE / DERATE TO ADD LIFE RUNTIME CHARTS

UPS SIZING – EXAMPLE SPREADSHEET

BATTERY SAFETY MAINTENANCE RISKS DISPOSAL INSPECT PERIODICALLY REPLACE AS NEEDED RISKS ACID ELECTRIC SHOCK BURN FLYING, MOLTEN METAL (EYES) INJURIES RESULTING FROM CARRYING HEAVY BATTERY PACKS DISPOSAL DISPOSE OF PROPERLY RECYCLE WHENEVER POSSIBLE

GENERAL DISCUSSION DOES A UPS OFFER COMPLETE PROTECTION? DO YOU THINK “POWER DISTURBANCES WON’T HAPPEN TO YOU” ? MISCELLANEOUS

DOES A UPS OFFER COMPLETE PROTECTION? SOME POWER DISTURBANCES MAY EXCEED THE HANDLING CAPABILITY OF THE UPS UPS FAILURE

DO YOU THINK “POWER DISTURBANCES WON’T HAPPEN TO YOU” ? POWER DISTURBANCES OCCUR FREQUENTLY, THOUGH MANY ARE SMALL AND WITHOUT CONSEQUENCE AN ON-LINE UPS CAN PROTECT AGAINST MORE SIGNIFICANT POWER DISTURBANCES WHEN THEY DO OCCUR THE COST OF NOT HAVING A UPS CAN EASILY EXCEED THE COST OF A UPS

MISCELLANEOUS MANY RETAIL UPS FOR COMPUTER APPLICATIONS ARE LINE INTERACTIVE MANUFACTURERS AND BUILDING CODES DO NOT ALLOW EXTENSION CORDS OR SURGE SUPPRESSORS TO BE USED WITH A UPS

SUMMARY THINGS TO CONSIDER WHEN SPECIFYING A UPS POWER QUALITY ARCHITECTURE - LINE INTERACTIVE OR ON-LINE WAVEFORM - SQUARE, MODIFIED SINE, TRUE SINE IMMUNITY TO DISTURBANCES OTHER THAN OUTAGE RUN TIME WITH AN OUTAGE RELIABILITY AUDIBLE NOISE MONITOR AND CONTROL HARDWARE / SOFTWARE LOCAL / REMOTE CONTROL INITIAL COST MAINTENANCE COST WARRANTY

REFERENCES IEEE STANDARD 1100-2005 IEEE STANDARD 1159-1995 RECOMMENDED PRACTICE FOR POWERING AND GROUNDING SENSITIVE ELECTRONIC EQUIPMENT IEEE STANDARD 1159-1995 RECOMMENDED PRACTICE FOR MONITORING ELECTRICAL POWER QUALITY

QUESTIONS