Yu. I. BARANOV and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg,

Slides:



Advertisements
Similar presentations
Yu. I. BARANOV, W. J. LAFFERTY, and G. T. Fraser Optical Technology Division Optical Technology Division National Institute of Standards and Technology,
Advertisements

Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Annual Meeting Imperial College, 16/12/2008.
CAVIAR meeting May, 13, 2010 – UCL, London 1/11 Cambridge Centre for Atmospheric Science Broad Band Cavity Enhanced Absorption Spectroscopy of the Water.
High sensitivity CRDS of the a 1 ∆ g ←X 3 Σ − g band of oxygen near 1.27 μm: magnetic dipole and electric quadrupole transitions in different bands of.
Raman Spectroscopy A) Introduction IR Raman
AAS and FES (Ch 9, 7th e, WMDS)
Georg Wagner, Manfred Birk Remote Sensing Technology Institute (IMF) Deutsches Zentrum für Luft- und Raumfahrt (DLR) Shepard A. Clough Clough Radiation.
Institute of Aerospace Thermodynamics H. Kamoun, G. Lamanna, B. Weigand Institute of Aerospace Thermodynamics, Universität Stuttgart Stuttgart Germany.
Selection of measuring instruments
CAVIAR water vapour laboratory FTS measurements Dr Robert McPheat CAVIAR Meeting Cosners’ House, 15/12/2009.
EXPERIMENTAL AND THEORETICAL STUDY OF WATER-VAPOR CONTINUUM ABSORPTION IN THE THZ REGION FROM 0.3 TO 2.7 THZ V.B. PODOBEDOV, D.F. PLUSQUELLIC, K.M. SIEGRIST.
Update on the Leicester lab studies (WP2.2 cavity ringdown spectroscopy) Stephen Ball & Simon Neil (Leicester University) CAVIAR science meeting, NPL,
David Paynter, Igor Ptashnik, Keith Shine Department of Meteorology University of Reading Kevin Smith (RAL) June 2006 Pure water vapor continuum measurements.
FASSST Cavity Ringdown Spectroscopy of Atmospherically Broadened Lineshapes in the Millimeter Spectral Region Corey Casto Frank C. De Lucia The Ohio State.
Laser spectroscopic study of ozone in the 100←000 band for the SWIFT instrument M. Guinet, C. Janssen, D. Mondelain, C. Camy-Peyret LPMAA, CNRS- UPMC (France)
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting Cosners’ House, 14/12/2009.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting NPL, 29/09/2010.
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting University of Leicester, 24/09/2009.
Improving Uncertainties of Non-Contact Thermometry Measurements Mark Finch Fluke Calibration.
Lecture 3 INFRARED SPECTROMETRY
Atomic Absorption Spectroscopy
EXPERIMENTAL ABSORPTION SPECTRA OF HOT CH 4 IN THE PENTAD AND OCTAD REGION ROBERT J. HARGREAVES MICHAEL DULICK PETER F.
Concentration Measurements of Porphyrin Solutions using the Cavity Ring-Down and Integrated Cavity Output Spectroscopy Techniques Deirdre O’Leary PY4060.
Sergey Mekhontsev National Institute of Standards and Technology Optical Technology Division, Gaithersburg, MD Infrared Spectral Radiance Scale.
LINE PARAMETERS OF WATER VAPOR IN THE NEAR- AND MID-INFRARED REGIONS DETERMINED USING TUNEABLE LASER SPECTROSCOPY Nofal IBRAHIM, Pascale CHELIN, Johannes.
COST 723 Training School - Cargese October 2005 OBS 2 Radiative transfer for thermal radiation. Observations Bruno Carli.
Norm Nelson, UCSB Chantal Swan, UCSB / ETH with assistance of: Julia Gauglitz, Teresa Serrano Catala, Erica Aguilera UltraPath in the Oligotrophic Ocean.
UV-Vis Absorption Spectroscopy
New High-Resolution Absorption Cross-Section Measurements of HCFC-142b in the Mid-IR Karine Le Bris St Francis Xavier University, Nova Scotia, Canada Kimberly.
Pressure Broadening and Spectral Overlap in the Millimeter Wave Spectrum of Ozone International Symposium on Molecular Spectroscopy 65 th Meeting — June.
DEVELOPMENTS IN FAST SCAN SUBMILLIMETER SPECTROSCOPIC TECHNIQUE (FASSST) AND COMPUTER AIDED ASSIGNMENT OF ASYMMETRIC ROTOR SPECTRA (CAAARS) SOFTWARE SUITE.
Michal Tepper Under the supervision of Prof. Israel Gannot.
Comparison of Experimental and Theoretical Cross-sections of PFBAm By: Paul J. Godin, Stephanie Conway, Angela Hong, Karine Le Bris, Scott Mabury, and.
Yu. I. BARANOV, W. J. LAFFERTY, and G. T. Fraser Optical Technology Division Optical Technology Division National Institute of Standards and Technology,
Misure ottiche su atmosfere planetarie in laboratorio
Precision Measurement of CO 2 Hotband Transition at 4.3  m Using a Hot Cell PEI-LING LUO, JYUN-YU TIAN, HSHAN-CHEN CHEN, Institute of Photonics Technologies,
Thoughts on the Design of a WVR for Alan Roy (MPIfR) the Twin Telescope at Wettzell.
The basics of in-situ Electrochemcial FTIR spectroscopy
Line list of HD 18 O rotation-vibration transitions for atmospheric applications Semen MIKHAILENKO, Olga NAUMENKO, and Sergei TASHKUN Laboratory of Theoretical.
Spectrophotometer.
3-D SUBMILLIMETER SPECTROSCOPY FOR ASTROPHYSICS AND SPECTRAL ASSIGNMENT SARAH M. FORTMAN, IVAN R. MEDVEDEV, FRANK C. DE LUCIA, Department of Physics, The.
1 Atmospheric Radiation – Lecture 7 PHY Lecture 7 Thermal Radiation.
DIODE-LASER AND FOURIER-TRANSFORM SPECTROSCOPY OF 14 NH 3 AND 15 NH 3 IN THE NEAR-INFRARED (1.5 µm) Nofal IBRAHIM, Pascale CHELIN, Johannes ORPHAL Laboratoire.
Beamline AILES : Mid IR to THz Spectroscopy The AILES Infrared and THz High Resolution Spectroscopy beamline at SOLEIL (Saclay, 30 km south of Paris) –
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
A new method for first-principles calibration
CH 3 D Near Infrared Cavity Ring-down Spectrum Reanalysis and IR-IR Double Resonance S. Luna Yang George Y. Schwartz Kevin K. Lehmann University of Virginia.
Progress in water vapour spectroscopy at RAL Dr Robert McPheat CAVIAR Progress Meeting Cambridge, 19/02/2011.
Vacuum Studies of LHCb Vertex Locator Sensors Gwenaëlle Lefeuvre, Ray Mountain, Marina Artuso Department of Physics, Syracuse University Abstract : The.
Yu. I. BARANOV, and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg,
Broadband Comb-resolved Cavity Enhanced Spectrometer with Graphene Modulator C.-C. Lee, T. R. Schibli Kevin F. Lee C. Mohr, Jie Jiang, Martin E. Fermann.
EXPERIMENTAL TRANSMISSION SPECTRA OF HOT AMMONIA IN THE INFRARED Monday, June 22 nd 2015 ISMS 70 th Meeting Champaign, Illinois EXPERIMENTAL TRANSMISSION.
FAST SCAN SUBMILLIMETER SPECTROSCOPIC TECHNIQUE (FASSST). IVAN R. MEDVEDEV, BRENDA P. WINNEWISSER, MANFRED WINNEWISSER, FRANK C. DE LUCIA, DOUGLAS T. PETKIE,
An Experimental Approach to the Prediction of Complete Millimeter and Submillimeter Spectra at Astrophysical Temperatures Ivan Medvedev and Frank C. De.
Date of download: 6/1/2016 Copyright © 2016 SPIE. All rights reserved. Schematic view of the pulsed PA spectrometer. Figure Legend: From: Investigation.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
G. Mevi1,2, G. Muscari1, P. P. Bertagnolio1, I. Fiorucci1
Spectroscopy Techniques
Cavity Ring Down: Absorption of H-D at 90K
Jacob T. Stewart Department of Chemistry, Connecticut College
The Near-IR Spectrum of CH3D
Jacob T. Stewart and Bradley M
G. Mevi1,2, G. Muscari1, P. P. Bertagnolio1, I. Fiorucci1
Nofal IBRAHIM, Pascale CHELIN, Johannes ORPHAL
Introduction to Atomic Spectroscopy
Raman Spectroscopy A) Introduction IR Raman
An accurate and complete empirical line list for water vapor
By Narayan Adhikari Charles Woodman
SPECTROPHOTOMETRY Applied Chemistry.
Presentation transcript:

Yu. I. BARANOV and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg, MD , USA The water vapor continuum absorption in the 8 to 12 μm region at temperatures from 311 to 352K.

Introduction  The water vapor continuum absorption in the atmospheric 8 to 12 μm window strongly affects the Earth’s outgoing radiation and therefore is of great importance for radiative balance calculations.  Over the past twenty years many groups in the world have used long-base (up to 100 m) long-path (up to several thousands m) cells to measure the H 2 O continuum.

Introduction  The other high-sensitive techniques, like photo-acoustic or cavity ring-down spectroscopy were also employed for these measurements.  Nevertheless the existing data is not adequate to match the current requirements.

Introduction  How to measure the continuum with the 2 m base multi-pass cell available at NIST? Is this possible?  This is certainly not possible at room or lower temperatures because of the low vapor pressure of H 2 O at these temperatures.

Introduction  The solution is to make the measurements at an elevated temperature. This allows one to fill the cell with water vapor at pressures up to several tens of torrs. This is enough to make continuum absorption measurable with the available path length of about 100 m since the continuum absorbance increases as the square of the water vapor pressure (density).

Experimental set-up view

Specific experimental details for H 2 O continuum measurements 1. How to avoid water vapor condensation? All of the protrusive parts of the cell, such as valves, window holders, sleeves etc., were equipped with additional electric heaters and coated with thermoinsulation. This was done in order to provide uniform temperature all of the parts of the internal cell surface and to avoid water vapor condensation. Six additional thermocouples were set up to measure and control temperatures.

Specific experimental details for H 2 O continuum measurements 2. How to get water vapor? The water vapor sampler is a horizontally positioned stainless steel cylinder with distilled water. The sampler is equipped with electric heater and thermoinsulation. The liquid water temperature was kept close to the cell body temperature. In order to save a thermal equilibrium and the optic stability we spent over 30 minutes to fill the cell with water vapor.

Specific experimental details for H 2 O continuum measurements 3. How to measure water vapor pressure? The gauge (Barocell 600A, 100 torr) for water vapor pressure measurement is also heated up to the cell body temperature. We calibrated it periodically filling the cell with nitrogen and measuring the pressure with the second gauge (MKS Baratron 270, 1000 torr), operating under regular temperature. The calibration dependence was found linear and stable. The pressure estimated systematic error is about 0.6%.

Experimental conditions Spectral resolution is 0.1cm -1

Experimental conditions Spectral resolution is 0.1cm -1 Why so low ?

Experimental conditions Spectral resolution is 0.1cm -1 Possible minimal Intensity of the instrument’s beam Why so low ?

Experimental conditions Spectral resolution is 0.1cm -1 Possible minimal Intensity of the instrument’s beam Acceptable signal to noise ratio: 200 – 300 scans Why so low ? +

Experimental conditions Spectral resolution is 0.1cm -1 Possible minimal Intensity of the instrument’s beam Acceptable signal to noise ratio: 200 – 300 scans Reasonable time of scanning: few hours Why so low ? ++

Experimental conditions Spectral resolution is 0.1cm -1 Possible minimal Intensity of the instrument’s beam Acceptable signal to noise ratio: 200 – 300 scans Reasonable time of scanning: few hours Why so low ? = 0.1cm -1 ++

Experimental conditions Temperature K (±0.3K) Pressure range torr Path length m Number of spectra to to to to to Spectral resolution is 0.1 cm -1

An example of IR water vapor spectrum

The quick data treatment method

The temperature dependence of the continuum binary absorption coefficient at 942 cm -1

The water vapor continuum absorption coefficients

The basic method of the data processing

Summary  Pure water vapor spectra have been recorded over a wide range of temperatures and pressures.  Continuum binary absorption coefficients have been determined in the region 800 cm -1 to 1150 cm -1.  Our data at 944 cm -1 have been compared with the data obtained recently by use of CRD spectroscopy technique. The systematic difference exceeds 10%. But relative changes of absorption coefficient with temperature are in good agreement.  Ro-vibrational structure has been calculated using the HITRAN data base and compared with experimental spectra. This comparison shows that the HITRAN water vapor absorption line intensities need to be corrected.