Frequency Scanning Interferometry (FSI) measurements

Slides:



Advertisements
Similar presentations
Target Test Diagnostics Richard Brownsword Engineering, Rutherford Appleton Laboratory.
Advertisements

Wave Nature of Light  Refraction  Interference  Young’s double slit experiment  Diffraction  Single slit diffraction  Diffraction grating.
Optical sources Lecture 5.
Solomon William KAMUGASA
Micro-triangulation for high accuracy short range measurements of dynamic objects Vasileios Vlachakis 1 st PACMAN Workshop February 2015 CERN, Geneva,
Stephen Gibson, ATLAS Offline Alignment, 2 nd July Incorporating FSI with the Offline Alignment Overview ATLAS Group, University of Oxford Stephen.
S. M. Gibson, IWAA7 November ATLAS Group, University of Oxford, UK S. M. Gibson, P. A. Coe, A. Mitra, D. F. Howell, R. B. Nickerson Geodetic Grids.
AMULET Advanced Metrology Using LasEr Tracers John Dale.
Precision Displacement Measurement via a Distance Measuring Interferometer (DMI)
Metrology and pre-alignment of the components of CLIC in the PACMAN project S. W. Kamugasa, V. Vlachakis CLIC Workshop January 2015 CERN, Geneva,
The LiCAS FSI Subsystem Current Status and Initial Measurements John Dale for the LiCAS Collaboration IOP HEP April 2008.
Alignment of DB and MB quadrupoles Hélène MAINAUD DURAND 17/11/2011 With a lot of input from Sylvain GRIFFET.
ILC roles Interferometry Results 2009 / 2010 Mon 20 Apr :00 JST (01:00 UTC) MDI TILC09 – Tsukuba OXFORD MONALISA 1.
Optics in Astronomy - Interferometry - Oskar von der Lühe Kiepenheuer-Institut für Sonnenphysik Freiburg, Germany.
Accelerator and Beam Delivery The LC-ABD (Linear Collider: Accelerator and Beam Delivery) consortium is a group of UK institutes aiming to develop new.
The Linear Collider Alignment and Survey (LiCAS) Project Richard Bingham*, Edward Botcherby*, Paul Coe*, Grzegorz Grzelak*, Ankush Mitra*, Johannes Prenting.
LiCAS Project: FSI Overview Richard Bingham, Edward Botcherby, Paul Coe, John Green, Grzegorz Grzelak, Ankush Mitra, John Nixon, Armin Reichold University.
Initial Calibration and Stability Results from the LiCAS RTRS FSI System John Dale for the LiCAS Collaboration IWAA February 2008.
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
S. M. Gibson, P. A. Coe, Photon02, 5 th September Coordinate Measurement in 2-D and 3-D Geometries using FSI Overview ATLAS Group, University of.
Newton’s Rings Another method for observing interference in light waves is to place a planoconvex lens on top of a flat glass surface, as in Figure 24.8a.
Chapter 25: Interference and Diffraction
High index glass spherical targets for laser interferometry Miroslav Sulc 1st PACMAN worshop 1.
MONALISA David Urner, Armin Reichold, Paul Coe, Matthew Warden, Geoff Rayner Monitoring Alignment and Stabilisation with high Accuracy (Previously known.
Frequency Scanning Interferometry in detail 3 Oxford contributions to IWAA 2002 Multiple, simultaneous length measurements S. M. Gibson et al (After the.
S. Gibson FSI Offline Analysis 9 th October FSI Alignment: Offline Analysis Overview ATLAS Group, University of Oxford Stephen Gibson, Danny Hindson,
Pre-alignment solutions applied to girders 1/19 Sylvain GRIFFET, 06/07/2010.
Interference Diffraction and Lasers
H. SCHMICKLER Alignment challenges for a future linear collider.
The wave nature of light Interference Diffraction Polarization
Laser interferometer Su-Jin Kim, GNU & Xiaoyu Ding.
David Urner, Oxford University, RHUL – June StaFF Stabilization of Final Focus Motion Stabilization with Nano-Meter Precision David Urner Paul Coe.
LASER AND ADVANCES IN METROLOGY
H. MAINAUD DURAND, on behalf of the CLIC active pre-alignment team MDI alignment plans IWLC2010 International Workshop on Linear Colliders 2010.
Development & validation of an absolute FSI network STATUS & NEXT STEPS SU internal meeting 16 July 2015 Solomon William KAMUGASA.
H. MAINAUD DURAND PACMAN WP1 OUTLINE Tasks & role of associated partner Plans for training.
MONALISA an Update David Urner Paul Coe Matthew Warden Armin Reichold Monitoring, Alignment & Stabilisation with high Accuracy.
教育部顧問室光通訊系統教育改進計畫台科大 師大 淡江 東南 萬能 教育部顧問室光通訊系統教育改進計畫 台科大 師大 淡江 東南 萬能 11 波長 (Wavelength) 的精準量測 The amplitude versus wavelength, can be measured by wavelength.
Interference in Thin Films, final
Frequency Scanned Interferometer Demonstration System Tim Blass, Jason Deibel, Sven Nyberg, Keith Riles, Haijun Yang University of Michigan, Ann Arbor.
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
CLIC survey and alignment 1 CLIC CES meeting STARTSLIDE CLIC SURVEY AND ALIGNMENT Hélène MAINAUD DURAND.
Welcome to MONALISA A brief introduction. Who we are... David Urner Paul Coe Matthew Warden Armin Reichold Electronics support from CEG Central Electronics.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Coherent Diffraction Radiation experiment Konstantin Lekomtsev, Grahame Blair, Gary Boorman, Pavel Karataev, Maximilian Micheler John Adams Institute at.
CLIC Module WG 20/07/2009 H. MAINAUD DURAND, BE-ABP/SU Pre-alignment system and impact on module design.
MONALISA: The precision of absolute distance interferometry measurements Matthew Warden, Paul Coe, David Urner, Armin Reichold Photon 08, Edinburgh.
MONALISA David Urner Paul Coe Matthew Warden Armin Reichold Monitoring, Alignment & Stabilisation with high Accuracy.
1/13 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 9, 2006) Mount.
Solomon William KAMUGASA
Laser Alignment System for LumiCal and BeamCal Arkadiusz Moszczyński, Wojciech Wierba, Leszek Zawiejski Institute of Nuclear Physics PAN, Cracow 22nd FCAL.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignement team QD0 and BDS pre-alignment.
Fourier Transform Infrared (FTIR) Spectrometer Subhashree Mishra ATMS Grad Student, UNR W. P. Arnott Physics, UNR Introduction to Atmospheric Instrumentation.
PACMAN : technical objectives Hélène Mainaud Durand.
Piezo and retroflector calibration Understanding the details of interferometer performance.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Interference of Light Ø It is generally He-Ne type that generates stable coherent light beam of two frequencies. one polarized vertically and another.
WP3 Frequency Scanning Interferometry Analysis Techniques for the LiCAS RTRS John Dale.
Interference and Diffraction
UNIT-3 ADVANCES IN METROLOGY
on behalf of the CLIC active pre-alignment team
Recent developments on micro-triangulation
Project Status & Next Steps Solomon William KAMUGASA
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
Alignment challenges for a future linear collider
AMULET Advanced Metrology Using LasEr Tracers (and various other bits)
LightGage™ Frequency Scanning Technology
The Speed of Light in Vacuum
David Urner, Armin Reichold , Paul Coe, Matthew Warden, Geoff Rayner
Presentation transcript:

Frequency Scanning Interferometry (FSI) measurements PACMAN internal meeting 28/04/2014 Solomon William Kamugasa

Contents Background concepts Interferometry: (Displacement & FSI) Sources of error in FSI System components How to determine 3D position using FSI FSI in CLIC Other applications of FSI Ongoing work PACMAN internal meeting, 28/04/2014

Background Superposition: Resultant displacement produced by a number of waves at a point is the algebraic sum of displacements of the individual waves. Interference: Combination of 2 waves to form composite waves. In phase Constructive interference Out of phase Destructive interference PACMAN internal meeting, 28/04/2014

Background Phase: Used to describe a specific location within a cycle of a periodic wave. Phase = 2𝜋 𝜆 * OPL Phase ambiguity when OPL > λ Phase difference: Describes how far out of sync two waves are. Phase difference,δ= 2π λ * OPD OPD is Optical Path Difference; OPL is Optical Path Length. λ 𝜋 2𝜋 δ 𝜋 2𝜋 PACMAN internal meeting, 28/04/2014

Interferometry Michelson Interferometer Technique based on interference that measures properties of light waves such as wave length and optical path length. Requires: Coherent light source. Monochromatic light. Measures displacement by observing fringes. Fixed Reflector Coherent light source Beam Splitter MovableReflector Detector PACMAN internal meeting, 28/04/2014 PACMAN internal meeting, 28/04/2014

Displacement Interferometry Light of fixed wavelength. Precise (fraction of wavelength). Cannot measure absolute distance directly. To measure displacements > 𝜆 2 requires fringe counting. Target needs to be physically moved. Measurements have to be repeated if system loses count of cycles. Intensity minima Intensity maxima PACMAN internal meeting, 28/04/2014

FSI Absolute distance measuring interferometric technique. Measures phase changes in a measurement and reference interferometer as frequency is scanned. Δ 𝑃ℎ𝑎𝑠𝑒 𝑀 = 2𝜋 𝑐 𝐿 𝑀 ∗Δ𝑣 Δ 𝑃ℎ𝑎𝑠𝑒 𝑅 = 2𝜋 𝑐 𝐿 𝑅 ∗Δ𝑣 Δ 𝑃ℎ𝑎𝑠𝑒 𝑀 Δ 𝑃ℎ𝑎𝑠𝑒 𝑅 = 𝐿 𝑀 𝐿 𝑅 (when no drift) Measurement interferometer OPD: 𝐿 𝑀 Tunable laser When the laser is tuned, the induced phase shift per unit change in laser frequency is proportional to the interferometer OPD. Hence by measuring the tuning frequency interval and the induced phase shift, the OPD can be determined. The phase of each GLI is measured indirectly by numerical analysis of the sampled intensity measurements from the photodetector. Reference interferometer OPD: 𝐿 𝑅 PACMAN internal meeting, 28/04/2014 PACMAN internal meeting, 28/04/2014

FSI Advantages Measures absolute distance. Beams can be interrupted as does not rely on fringe counting. Ability to measure several interferometers simultaneously. Disadvantages Tend to be less accurate than displacement interferometry (because it measurements are made relative to a physical reference). Accuracy reduced by drift errors (dominant source of error in FSI). PACMAN internal meeting, 28/04/2014

In the presence of drift the phase ratio, q is Drift: Change of interferometer length during measurement typically through thermal expansion or contraction. In the presence of drift the phase ratio, q is 𝑞= Δ 𝑃ℎ𝑎𝑠𝑒 𝑅 Δ 𝑃ℎ𝑎𝑠𝑒 𝑀 = 2𝜋 𝑐 𝐿 𝑅 Δ𝑣+𝑣Δ 𝐿 𝑅 2𝜋 𝑐 𝐿 𝑀 Δ𝑣+𝑣Δ 𝐿 𝑀 𝑞= 𝐿 𝑅 𝐿 𝑀 1+Ω𝜀 Where, Ω= 𝑣 Δ𝑣 and 𝜀= Δ 𝐿 𝑅 𝐿 𝑅 − Δ 𝐿 𝑅 𝐿 𝑀 where: 𝑣 is the average frequency. Δ𝑣 is the scanned frequency. Δ 𝐿 𝑅 & Δ 𝐿 𝑀 are reference & measurement interferometer drifts. Ω is a magnifying factor that causes much greater error than the drift itself (typically >100). 𝜀 is the relative drift error. PACMAN internal meeting, 28/04/2014

Limited by control of environmental factors that cause drift. Drift management Limited by control of environmental factors that cause drift. Using faster electronics that make measurements quicker. Using a stable reference such as Invar (nickel-iron alloy) with low CTE ≈ 1.2 ppm per °C in range of 20-100 °C. Reference interferometer drift can be eliminated by replacing physical length reference. FSI phase measurements are made at beat frequencies generated between a fixed-frequency laser & tunable laser. The change of beat frequency over the scan is twice the scan average frequency, and so the magnification of the drift is 0.5 PACMAN internal meeting, 28/04/2014

Drift cancellation Corrected by 2 lasers scanning simultaneously Tunable laser Corrected by 2 lasers scanning simultaneously in opposite directions. 𝐷 1 = 𝐷 𝑡𝑟𝑢𝑒 + Ω 1 ∗Δ 𝜀 1 𝐷 2 = 𝐷 𝑡𝑟𝑢𝑒 + Ω 2 ∗Δ 𝜀 2 Δ 𝜀 is the drift error & Ω magnification factor Since beam travel same path, Δ 𝜀 1 =Δ 𝜀 2 𝐷 𝑡𝑟𝑢𝑒 = 𝐷 2 −𝜌∗ 𝐷 1 1−𝜌 where, 𝜌= Ω 2 Ω 1 2 similar lasers scanning in opposite directions simultaneously 𝜌 ≈ -1.0. 𝐷 𝑡𝑟𝑢𝑒 ≈ 𝐷 1 + 𝐷 2 2.0 Measurement interferometer Reference interferometer Tunable laser PACMAN internal meeting, 28/04/2014

Refractive index, 𝜼 Physical Length= Optical Path Difference 2η Modelled using refractivity, ϱ= η Air -1 Refractometer: Directly measures η Alternatively by measuring the parameters on which η depends i.e. temperature, pressure, humidity and CO 2 . Relies on homogeneity of air. Use of air tight container (not very practical, severe engineering and high cost). PACMAN internal meeting, 28/04/2014

Determining the position of fibre launchers Position of launchers is required in order to determine that of the fiducials. Distance 𝐷 𝑖 from launcher to fiducials determined using FSI. Fiducial coordinates previously measured by CMM. Coordinates of fibre launcher determined using the equation below: 𝐷 𝑖 = 𝑋 𝐹𝑖 −𝑋 𝐿 2 + 𝑌 𝐹𝑖 −𝑌 𝐿 2 + 𝑍 𝐹𝑖 −𝑍 𝐿 2 Where 𝑖 is the fiducial number. PACMAN internal meeting, 28/04/2014

Determination of fiducial coordinates Requires at least 3 launchers with known position. Unknown coordinates of fiducial ( 𝑋 𝐹 𝑌 𝐹 𝑍 𝐹 ) determined using the equation below. 𝐷 𝑖 = 𝑋 𝐹 −𝑋 𝐿𝑖 2 + 𝑌 𝐹 −𝑌 𝐿𝑖 2 + 𝑍 𝐹 −𝑍 𝐿𝑖 2 where 𝑖 is the fibre number. Networks will be resolved using Least Squares Adjustments. PACMAN internal meeting, 28/04/2014

Reference Interferometer Physical length standard Reference needs to be calibrated in order to be traceable. Measurements rely on stability of reference. Alternative Wavelength of a He-Ne laser determined by energy levels in the gas atoms in the laser cavity (little dependence on ambient conditions). Atomic transitions lines in an absorption gas cell (weak dependence on ambient conditions). Benefit: Requires a single calibration, valid for the life of the instrument. PACMAN internal meeting, 28/04/2014

Measurement interferometer Each measurement interferometer consists of a quill (two parallel optical fibres and a beam splitter) and a reflector. Delivery fibre Return fibre Retroreflector Beam Splitter PACMAN internal meeting, 28/04/2014

Main System components Laser Narrow line width: Provides good fringe visibility. Wide tuning range: Better measurement precision. Diode laser most commonly used for FSI. Replaced dye lasers. PACMAN internal meeting, 28/04/2014

Main system components Optical fibres Used to deliver light waves from laser to interferometer and to deliver the return signal from interferometer to photo detector. Light propagated through fibres by total internal reflection. Single mode fibres (D=8-10μm). Sharper light longer distances. PACMAN internal meeting, 28/04/2014

Main system components Retroreflectors Incident light is reflected exactly in the direction of origin. Typically corner cube (3 mutually orthogonal surfaces). Retroreflectors are made of various materials. Aluminium pellets coated with gold to enhance reflectivity (ATLAS). Commercially - Glass prisms (utilise total internal reflection). Mirror reflectors are also available. corner cube retro reflectors (3 mutually orthogonal reflective surface). PACMAN internal meeting, 28/04/2014

FSI in CLIC CMM: Most accurate (0.3 μm + 1ppm) for Leitz at CERN. Loses accuracy beyond measurement volume of 1.2*1.0*0.7 m 3 . Impossible to use when dimensional control measurements are required on site. Existing portable means don’t perform to the required accuracy. Faro Romer Arm: Accuracy (5-10 μm at 1σ) Leica AT401 Laser Tracker (7-10 μm at 1σ) Photogrammetry (12 μm at 1σ) Therefore need to develop a portable means that is more accurate. Microtriangulation (1.3) FSI (1.2) PACMAN internal meeting, 28/04/2014

Monitoring and Control CMMs show systematic deviations resulting from aging & elastic deformations etc. FSI will be used to continuously monitor the CMM to provide control of systematic deviations. PACMAN internal meeting, 28/04/2014

PACMAN internal meeting, 28/04/2014

Other FSI applications FSI at ATLAS Used to remotely monitor shape changes of the SCT. Measurement precision of 1μm. 3D coordinate reconstruction to 10μm. 842 measurement interferometers. Radiation-hard low mass components. No maintenance over 10 years. Fibres 100m long from interferometer to detector/laser. The OPDs of the measured interferometers may vary slightly while the laser is tuning, thus inducing unwanted, additional phase shifts. In addition, the weakness of the interferometer signals, a consequence of the misalignment tolerant interferometer design, will require much longer measurement times, of the order of a minute, and hence the OPD drift will be much greater. ATLAS Experiment © 2014 CERN PACMAN internal meeting, 28/04/2014

Project 1.2 Work in progress Develop fiducials measureable by FSI, Micro-triangulation & CMM. Why? More redundancy and ability to detect faults. Study the mechanics of fibre ends and targets in order to determine their systematic offsets/errors and those of the target holders. Study various configurations of the FSI network in order to select the best one through simulations. Extrapolate to a portable solution. PACMAN internal meeting, 28/04/2014

References Coe P. A (2001) An Investigation of Frequency Scanning Interferometry for the alignment of the ATLAS semiconductor tracker. Dphil thesis, University of Oxford. Dale J. (2009) A Study of Interferometric Distance Measurement Systems on a Prototype Rapid Tunnel Reference Surveyor and the Effects of Reference Network Errors at the International Linear Collider. Dphil thesis, University of Oxford. Griffet S., Cherif A., Kemppinen J., Mainaud Durand H., Rude V., Sterbini G. Strategy and validation of fiducialisation for the pre-alignment of CLIC components, CERN Geneva, Switzerland. Griffet S (2010) Fiducialisation and Dimensional Control: Study of existing means and expected performances. EDMS 1097661. Warden M.S (2011) Absolute distance metrology using frequency swept lasers. DPhil thesis, University of Oxford. Absolute Multiline®-Technology A revolution in length metrology. Available on Indico, Presented by Mainaud Durand H. PACMAN internal meeting, 28/04/2014