MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK ALBERT-EINSTEIN-INSTITUT Karsten Kötter1 DC Data Analysis SEI/SUS (Suspensions & Seismic Isolation) DC Workshop, Golm Karsten Kötter
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter2 power spectra / psd checked Matlab psd/pwelch algorithm to get power spectral densities / spectra right
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter3 psd / pwelch Matlab psd function scaling not clear Matlab pwelch function calculates correctly power spectral densities conversion to power/amplitude spectra not possible conversion factor ENBW ("Equivalent Noise BandWidth") is not given
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter4 Spectral density - pwelch
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter5 asd script wrote Matlab script to calculate asd (amplituide spectral density) ENBW allows you to calculate asd, psd, as, ps
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter6 Spectral density - asd
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter7 Spectrum - asd
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter8 Comparison ACC/SEIS sensors compared ACC sensor signals to SEI sensor signal consistency check for calibration functions
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter9
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter10 Comparison ACC/SEIS sensors
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter11 Coherence seismic - MI output calculated coherence function between LSC_MID_EP-P and seismic channels check whether sensitivity is limited by seismic motion in some frequency bands
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter12 Coherence seismic - MI output
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter13 SEI_TFN_ACC-Y-ST3
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter14 coherence plots - results output dominated by noise from TFN at 8-10 Hz mechanical resonance in suspension (horizontal mode of stack rubber layer)
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter15 coherence plots - results
MAX-PLANCK-INSTITUT FÜR GRAVITATIONSPHYSIK - ALBERT- EINSTEIN-INSTITUT Karsten Kötter16 evolution of signals over c.run