Lecture 6a Cyclic Voltammetry.

Slides:



Advertisements
Similar presentations
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
Advertisements

Chemical equilibrium: electrochemistry 자연과학대학 화학과 박영동 교수.
Mrs Khadijah Hanim bt Abdul Rahman Sem II 2011/2012 Week 15: 28 & 31 May 2012.
Chapter 4 Electrochemical kinetics at electrode / solution interface and electrochemical overpotential.
Chemistry 232 Electrochemistry. A Schematic Galvanic Cell Galvanic cells – an electrochemical cell that drives electrons through an external circuit spontaneous.
Cells and Voltage.
Cells and Voltage.
Introduction to Electroanalytical Chemistry
Yat Li Department of Chemistry & Biochemistry University of California, Santa Cruz CHEM 146C_Experiment #8 Surface Electrochemistry: Adsorption of Polyoxometalate.
Introduction to electrochemistry - Basics of all techniques -
Chapter 17 Electrochemistry
ELECTROCHEMISTRY Chapter 17. W HAT IS ELECTROCHEMISTRY Electrochemistry is the science that unites electricity and chemistry. It is the study of the transfer.
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Types of Electrochemical Cells Electrolytic Cells: electrical energy from an external source causes a nonspontaneous reaction to occur Voltaic Cells (Galvanic.
Chapter 17 Electrochemistry
Electrolytic Cells Lesson 8 Electrolytic Cells ELECTROLYSIS Electrolysis is a method of using a direct electric current (DC) to drive an otherwise non-
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Voltammetry Nov 16, 2004 Lecture Date: March 27th, 2006.
Electrochemistry for Engineers LECTURE 4 Lecturer: Dr. Brian Rosen Office: 128 Wolfson Office Hours: Sun 16:00.
INTRODUCTION TO ELECTROCHEMICAL CELLS AND BASIC ELECTROANALYTICAL MEASUREMENTS ANDREA MARDEGAN JAN 17th 2013.
Electroanalytical Chemistry
Experimental techniques Linear-sweep voltammetry At low potential value, the cathodic current is due to the migration of ions in the solution. The cathodic.
Voltaic Cells Chapter 20.
Electrochemistry 18.1 Balancing Oxidation–Reduction Reactions
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 14
ELECTROCHEMISTRY Chapter 17. W HAT IS ELECTROCHEMISTRY Electrochemistry is the science that unites electricity and chemistry. It is the study of the transfer.
Chapter 26. An electrochemical cell A device that converts chemical energy into electrical energy. A Daniell cell is a device that could supply a useful.
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
16-1 Voltammetry Electrochemistry techniques based on current (i) measurement as function of voltage (E appl ) Working electrode §(microelectrode) place.
Voltammetry: A Look at Theory and Application Bobby Diltz 14 March 2005.
Electrochemistry Introduction
Electrochemical Cell An electrochemical cell uses chemistry to produce electricity.
1 Chapter Eighteen Electrochemistry. 2 Electrochemical reactions are oxidation-reduction reactions. The two parts of the reaction are physically separated.
Investigating Electrolysis Reactions Background When an electric current is passed through a liquid (solution or melt), chemical reactions take place at.
John E. McMurry Robert C. Fay C H E M I S T R Y Chapter 17 Electrochemistry.
Chapter 26 – Electricity from Chemical Reactions.
CHAPTER 11 ELEMENTS OF ELECTROCHEMISTRY Introduction to Analytical Chemistry.
Chapter 17 Corrosion and Degradation of Materials.
Voltaic/Galvanic Cells. Voltaic Cells In spontaneous oxidation-reduction (redox) reactions, electrons are transferred and energy is released.
Electric energy Chemical energy Electrolysis Galvanic cell Chapter 8 Electrochemistry.
Electricity from chemical reactions Galvanic Cells Chapter 14.
Electrochemical cells - batteries
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 18, 19, 21.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Consider the reduction half reaction: M z+ + ze → M The Nernst equation is E = E ө + (RT/zF) ln(a) When using a large excess of support electrolyte, the.
Chapter 20: Electrochemistry. © 2009, Prentice-Hall, Inc. Electrochemical Reactions In electrochemical reactions, electrons are transferred from one species.
9.2 Electrochemical Cells
ELECTROCHEMISTRY CHEM171 – Lecture Series Four : 2012/01  Redox reactions  Electrochemical cells  Cell potential  Nernst equation  Relationship between.
Instrumental Analysis Polarography and Voltammetry
Home Reading Skoog et al. Fundamentals of Analytical Chemistry. Sections 18A, 18C ( in chapter 18 ), Chapter 23.
Electrochemistry. three principal sources for the analytical signal potential, current, charge a wide variety of experimental designs are possible.
Electrochemical Methods: Intro Electrochemistry Basics Electrochemical Cells The Nernst Equation Activity Reference Electrodes (S.H.E) Standard Potentials.
Introduction to Electroanalytical Chemistry
Voltammetry and Polarography
Lecture 7a Cyclic Voltammetry.
Electrochemistry: Introduction Electrochemistry at your finger tips
Electrochemical cells
14.2a Voltaic Cells Basic Function.
Fundamentals of Electrochemistry
Advanced Higher Chemistry Unit 2(e)
Chapter 17: Electrochemistry
Solar-Thermal Decoupled Electrolysis: Assessment of MnxOy Systems
Complex Anode Kinetics Chronocoulometry Evidence
Electrochemistry i.e. This is the End!.
3- Oxidation-Reduction (Redox) titration
Voltametric techniques Chapter 2 Prof. Rezvani.
Electrochemistry Part II: The Galvanic Cell
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Presentation transcript:

Lecture 6a Cyclic Voltammetry

Introduction I Electrochemical methods are used To investigate electron transfer processes and kinetics To study redox processes in organic and organometallic chemistry To investigate multi-electron transfer processes in biochemistry and macromolecular chemistry To determine adsorption processes on surfaces To determine electron transfer and reaction mechanisms To determine of thermodynamic properties of solvated species

Introduction II Methods Polarography: Often used mercury dropping electrodes because the drop is only used for one measurement and then discarded Linear sweep voltammetry (LSV): the current at a working electrode is measured while the potential between the working electrode and a reference is swept linearly in time Cyclic voltammetry: the same as LSV but the potential is swept in a way that the experiment ends where it started

Cyclic Voltammetry I This technique is based on varying the applied potential at a working electrode (compared to the reference electrode) in both forward and reverse directions while monitoring the current between the auxiliary electrode and reference electrode Peaks will be observed at potentials that initiate a chemical reaction in the solution (reduction or oxidation) because they involve a flow of electrons

Cyclic Voltammetry II For a reversible reaction, the peak current for the forward sweep of the first cycle is proportional to the concentration of the analyte and the square root of the sweep rate (Randles–Sevcik expression): n is the number of electrons in the half-reaction A is the area of the electrode (cm2) C is the concentration of the analyte (mol/L) D is the diffusion coefficient of the analyte (cm2/s) n is the sweep rate (V/s) From this equation, it can be concluded that the peak current increases with the sweep rate, with the concentration and the area of the electrode as long as the reaction is reversible  

Cyclic Voltammetry III What is needed to run the experiment? Glass cell with the three electrodes Working electrode (left, glassy carbon in this course) Reference electrode (middle, Ag/AgCl/0.1 M LiCl in dry acetone) Auxiliary electrode (right, Pt-disk electrode) Three electrodes are needed because the measurement of the potential and the current have to be performed in different cycles because they interfere with each other A gas line for ebulliating the solution with nitrogen is also evident on the upper right hand A potentiostat that allows for the control of the potential and the measurement of a current Computer system for control and recording

Cyclic Voltammetry IV Dry solvent Electrolyte Analytes To prevent or reduce side reactions Dry dichloromethane from solvent still (Be careful!) Electrolyte Organic solvents exhibit a very low electrical conductivity Tetraalkylammonium salt with an inert anion i.e., BF4-, ClO4-, PF6-, etc. (NEt4BF4) Typically about 0.1 M solution Analytes Ferrocene: to check setup and figure out appropriate adjustment in redox potentials as needed Mdtc3: analytes, 0.005-0.01 M

Cyclic Voltammetry V Data analysis The cathodic Epc and anodic Epa peak potentials The cathodic half peak potential Ep/2 and the half way potential E½ The cathodic (ipc) and anodic (ipa) peak currents The formal reduction potential is obtained by E0= (Epa+Epc)/2 The half peak potential E1/2 can be described by the Nernst Equation   E1/2=Eo + DO, DR = diffusion coefficient of oxidized or reduced species (DO~DR)

Cyclic Voltammetry VI Reversible process Condition 1: DEp = │Epa – Epc│= 57/n (mV) (theoretically) n=number of electrons transferred in the process Usually more like 70 mV/n because of cell resistance Condition 2: The ratio of the anodic and cationic peak (ipa/ipc) should be close to one and independent from the scan rate

Experiment I After placing a given amount of the solvent with the electrolyte on the cell, a certain amount of the analyte is dissolved (~0.005 M -0.01 M) The electrodes are placed in the solution and connected to their respective cables Make sure that the alligator clamps do not touch Make sure to check if the reference electrode contains sufficient liquid that the silver wire is not just hanging in the glass tube Make sure that the instrument and the electrode are set properly (Experiment Properties/Cell Definitions) Initially, the potentials are set to initial and final potential V=-1.5 V while the vertex potential is V=1.5 V with a scan rate of 200 mV (Experiment Properties/Scan Definitions) and a purge and equilibration time of 30 seconds each

Experiment II Next, the run is started The nitrogen flow is started at a rate that the nitrogen bubbles slowly through the solution while the solution is stirred Once the purge time is completed, the stirred and the nitrogen flow are discontinued After the equilibrium time, the actual sweep starts as indicated in the status window An overflow error usually indicates a short circuit or poor contact somewhere The graph that appears should look like the one to the right, but with two peaks because the oxidation step and the reduction step are recorded in the same scan After the run is completed, the data is printed, saved and then erased on the screen (Edit-Select all and Delete points) Next, the window for the sweep is narrowed (focus on each peak separately (±0.3 V from maximum, (Experiment Properties/Scan Definitions)) and the sweep rate reduced (20-30 mV/s) It is highly advisable to bring a flash drive with you to store the data (as ASC file)