Review of Analytical Methods Part 2: Electrochemistry
Advertisements

Potentiometric Methods
Potentiometric Methods A.) Introduction:
15-1 Potentiometry Potential measurements of electrochemical cells Ion selective methods §Reference electrode §Indicator electrode §Potential measuring.
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
A galvanic cell is made from two half cells. In the first, a platinum electrode is immersed in a solution at pH = 2.00 that is M in both MnO 4 -
Chapter 20: Electrochemistry
ELECTROCHEMISTRY CHEM 4700 CHAPTER 5 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Electroanalytical – Introduction Ch 21, 7th e, WMDS)
Measuring concentration using electrodes Indicator electrodes used with reference electrode to measure potential of unknown solution E cell = E indicator.
POTENTIOMETRY 9th lecture
Electrodes and Potentiometry
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
14-6 Cells as chemical probes
Version 2012 Updated on 0510 Copyright © All rights reserved Dong-Sun Lee, Prof., Ph.D. Chemistry, Seoul Women’s University Chapter 17 Applications of.
Cell Voltages To compare cells compare voltages of cells in their standard state. Standard States For solids and liquids: the state of the pure solid or.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Potentiometry and the Detection of Fluoride
Potentiometric Methods
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
PH In the Laboratory. Ionization of Water Equllibrium Constant, K eq.
Electrochemical cells Sähkökemian peruseet KE Tanja Kallio C213 CH 4.1 – 4.2, 4.7.
POTENTIOMETRY 8th lecture
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 14
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
A Seminar on Potentiometric and Diazotization Titrations
Electroanalytical methods
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Potentiometry Dr Hisham E Abdellatef 2010.
Unit 2 Electrochemical methods of Analysis
Announcements Course Evaluations Final is Wednesday Afternoon on May 9 th Homework 14-15, 14-26, 15-6, 16-3, 16-6,
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Chapter 7 Electrochemistry
Chapter 15 Electrode Measurements “Chem 7” test in hospital lab. Na +, K +, Cl -, CO 2, glucose, urea, & creatinine ion-selective electrodes.
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
CHAPTER 11 ELEMENTS OF ELECTROCHEMISTRY Introduction to Analytical Chemistry.
THE ELECTROD AND REDOX POTENTIIALS.
LECTURE 7: Electrochemistry. Types of electrodes and their using. ass. prof. Yeugenia B. Dmukhalska.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Potentiometry.
§7.10 Application of EMF and electrode potential
Chem. 133 – 3/3 Lecture. Announcements Homework Set 2 (pass out) Grading –Working to get the Electronics labs and exam 1 graded by next Tuesday Lab –today.
POTENTIOMETRY.
Chapter 21 Potentiometry. Potentiometric methods of analysis are based on measuring the potential of electrochemical cells without drawing appreciable.
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 18, 19, 21.
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 14: ELECTRODES AND POTENTIOMETRY.
Ch. 21 Potentiometry 1. General principles
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Home Reading Skoog et al. Fundamentals of Analytical Chemistry. Chapter 10, 21.
SCI3023 ELECTROCHEMISTRY Chapter 8e: Potentiometry
Inovace bakalářského studijního oboru Aplikovaná chemie Reg. č.: CZ.1.07/2.2.00/
Instrumental Analysis Ion selective electrodes
ELECTRO CHEMISTRY.. References: 1.Engg.Chemistry by Jain and Jain 2.Engg.Chemistry by Dr. R.V.Gadag and Dr. A.Nithyananda Shetty 3.Principles of Physical.
Potentiometry and Ion-Selective Electrodes 1 Lecture 1.
Chapter 6 Electrochemical Analysis
Chem. 133 – 2/28 Lecture.
Electrochemistry MAE-212
Ion Selective Electrode
Potentiometry and potentiometric measurements
Ion Selective Electrode
Potentiometry Potential measurements of electrochemical cells
Electrode Measurements – Ch 15
Potentiometric Titration
Tracking Reaction Progress via Electrochemical Methods
Chapter 23 Potentiometry.
Presentation transcript:

Summary of Potentiometry: pH and Ion Selective Electrodes Potentiometric Sensors I = controlled at 0 Amps Eeq is measured In general Eeq = const – 0.0592 log aX

Electrode Potentials (review) Electrochemical cell – two half cells Convention, write both as reductions 2 AgCl (s) + 2 e- = 2 Ag (s) + 2 Cl- (cathode) - [2 H+ + 2 e- = H2 (gas)] (Pt, NHE reference, anode) Ecell = Ecathode - Eanode Cell reaction is the sum of the two above 2 AgCl (s) + H2 = 2 Ag (s) + 2 Cl- + 2 H+ Ecell = EAg/AgCl – EH+/H2 by convention EH+/H2 = 0 Ecell = EAg/AgCl = 0.46 V DG = - n F Ecell ; DG = positive, non-spontaneous, electrolytic cell

Ecell = EWE – Eref - Ejunction Measurements in Potentiometry; I = 0 Amps; equilibrium Cell: working electrode + reference electrode (E half cell = const) Working or indicator Ecell = EWE – Eref - Ejunction

Move slidewire (arrow) until G shows I = 0, then V = Ecell = Eeq Simple potentiometric measuring circuit Variable resistor V voltmeter galvanometer Move slidewire (arrow) until G shows I = 0, then V = Ecell = Eeq In practice this is all automatic in modern potentiometers or pH meters

Reference electrodes: critical to both potentiometry and voltammetry They keep a nearly constant half cell potential during experiment Normal Hydrogen, Pt| H2 (1 atm), HCL (0.01 M), NHE THE STANDARD, E = 0 V, but not practical Standard Calomel Electrode Hg| Hg2Cl2 (s), KCl (sat’d.) SCE Set up as self-contained Half cell Contact to test solution

Half cell potential of the SCE – serves as a reference against which other E’s are measured Hg2Cl2 (s) + 2 e- = 2 Hg (l) + 2 Cl- Use Nernst equation: E = Eo - [RT/nF] ln (aCl2 aHg2/acalomel) ; but a of pure solids =1 only aCl remains in the log term, and E = Eo’ - [0.0592/2] log [Cl-]2 or E = Eo’ - 0.0592 log [Cl-] ; sat’d KCl is ~3.5 M at 25 oC So ESCE = 0.244 V vs. NHE at 25 oC Alternative reference: Ag|AgCl (s), KCl (sat’d.) EAg/AgCl = 0.199 V vs. NHE at 25 oC

Half cell potential of the SCE – serves as a reference against which other E’s are measured Hg2Cl2 (s) + 2 e- = 2 Hg (l) + 2 Cl- Use Nernst equation: E = Eo - [RT/nF] ln (aCl2 aHg2/acalomel) ; but a of pure solids =1 only aCl remains in the log term, and E = Eo’ - [0.0592/2] log [Cl-]2 or E = Eo’ - 0.0592 log [Cl-] ; sat’d KCl is ~3.5 M at 25 oC So ESCE = 0.2415 V vs. NHE Alternative reference: Ag|AgCl (s), KCl (sat’d.) EAg/AgCl = 0.2415 V vs. NHE

Ion Selective Electrodes (ISE) - sensor surface usually a membrane That adsorbs the ions, Eeq measured at I = 0 Amps In pH electrode, the membrane is a very thin glass layer 0.1 M HCl Stand alone glass pH electrode must be used with reference Glass pH electrode combined with internal reference electrode Glass membranes are made of SiO2, Li2O (or Na2O) and BaO (or CaO)

ISE’s obey Nernst-like equations (25 oC) E = const + [0.0592/z] log aion ISE measure activity, not conc. if the ion Is H+, E = const - 0.0592 pH; pH = -log aH+ Fast response is important, < 1 s in buffer for most pH electrodes ISE Nernstian region, slope = 0.0591/z E, mV Most pH meters read pH directly, But must be calibrated daily Log aion

How a glass pH electrode responds to H+ ions (must store in in water or buffer to maintain hydrated layer) Ag/AgCl 0.1 N HCl aH+ = const Inner hydrated layer outer hydrated layer Dry glass Test solution aH+ , soln a1 a2 0.1 mm 50 mm E2 E1 EM = E1 – E2 + Eint ref; or EB = E1 – E2 (boundary E) Ecell = const + EB Li+ in glass can exchange with H+ (both small ions), giving rise to E1 and E2 H+ DOES NOT cross the membrane

EB is related to a1 and a2, but a2 is constant (0.1 M HCl) These ion activities control the membrane potentials, E1 and E2 and so control EB, at 25 oC EB = E1 – E2 = 0.0592 log (a1/a2) Ecell = const + 0.0592 log (a1) Ecell = const - 0.0592 pH In practice, pH meter incorporates these equations And relates them to measurements with standard buffer, And the output is a direct measurement of pH: pH = pHstd + F (Ecell - Estd)/2.303 RT, R = gas const, T = abs. temperature

Errors and Interferences in pH electrode measurements Alkaline error: In basic solutions or high salt conc. NaCl, KCl, Na+ and K+ interfere by adsorbing to the glass membrane then pHobs < true pH e.g. 0.1 M NaOH, pH 13, [Na+] is 0.1 M, [H+]= 1 x 10-13 Large error due to high [Na+], low [H+] In general fpr ISEs, Nicolsky equation Ecell = const + 0.0592 log [a1 + Σ Kjaj], j = 1….n interfering ions Kj = selectivity coefficient Acid error pH < 1, origin unknown pH electrodes reliable between pH 1 and 13 only

ISE’s for ions other than H+ • glass membranes, Na+, K+, NH4+ - different composition than pH • solid state membranes, F-, S- • liquid membranes, Ca+ • gas sensitive electrodes CO2, H2S, NH3 • enzyme electrodes – biological molecules • can all be used with pH meter in mV-mode

Fluoride ISE – Solid State Detection limit 10-9 M

Impregnated with ion exchanger; Ca++ ISE, Ca(dodecylphosphate) + Polymer like PVC; Phosphate groups bind Ca++ Crystals or solid state have the analyte Ion present, e.g. LaF3 Detection limit ~10-8 to 10-6 M

Urea Enzyme ISE (NH)2CO + 2 H2O + H+ 2 NH4+ + HCO3- Urease enzyme Detection limit ~10-6 M