Oxygen and wine Wes Ward April 2013.

Slides:



Advertisements
Similar presentations
Chemical Sensors for Autonomous and Lagrangian Platforms Ken Johnson, Monterey Bay Aquarium Research Institute.
Advertisements

New (and old) oceanographic tools 2012 Workshop DHP 2012 Tina Miller-Way.
Wine Science Forum Oxygen and wine Quality Stéphane Vidal.
OFFLINE COMPOSITION MEASURING SENSORS
Portavin integrated wine services A Bottling Perspective on Taints and Contributors to Variation.
MS FARZANA MEHBOOB D.A.NEELUM HIGH SCHOOL
EEE 529 Microsystems Amperometric Biosensors
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Luminescence Dissolved Oxygen
Simplicity in Water Analysis The Marketing Department 2003.
Pre-Filming Method of Reducing Metal Release from Alloy 690 for SG in Primary Water of PWR 2009 ISOE Asian ALARA Symposium Aomori September 9, 2009 Sumitomo.
Why Use Ozone  To improve water quality (disinfection)  To improve swimmer comfort  To reduce maintenance costs  To reduce chemical costs  To improve.
Oxygen, Temperature, Salinity Craig Kasper FAS 1401L Spring 2012.
ELECTROCHEMISTRY Chapter 17. W HAT IS ELECTROCHEMISTRY Electrochemistry is the science that unites electricity and chemistry. It is the study of the transfer.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Stephanie Pitcher GK-12. SENSORS  Are devices capable of detecting change:  Temperature  Pressure  Humidity  Speed  And Many more …  There are.
Edward C. Craig, Ph.D.* Cary B. Jackson, Ph.D. Christopher P. Fair
IC Controls 865 ppb Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards ppb Galvanic Dissolved Oxygen.
Measurement of Dissolved Oxygen with a Luminescence-based Oxygen Quenching Sensor By Cary B. Jackson, Ph.D. Hach Company.
.
Lecture 17: Aging. Reading Assignment: Text, Chapter 10, pages
Objectives Summarize Electric Power Measurement
Water Quality Analysis Methods and Applications. Water Quality Analysis Physical Factors including suspended materials (called suspended solids) and dissolved.
REDUCTION, SULFATES & LIGHTSTRIKE BY TIFFANEY AND MACKENZIE GWS 410 ~ FALL.
Corrosion/Erosion PROCESS OUT OF CONTROL.
The nitrogen cycle is the biogeochemical cycle that describes the transformations of nitrogen and nitrogen- containing compounds in nature biogeochemical.
ELECTROCHEMISTRY Chapter 17. W HAT IS ELECTROCHEMISTRY Electrochemistry is the science that unites electricity and chemistry. It is the study of the transfer.
Dissolved Oxygen The Good Gas. Photosynthesis: Your one-stop shop for all of your oxygen needs! Carbon Dioxide (from air) Water (from ground) Oxygen (to.
Carbon cycle observing in the coastal ocean Approaches: Remote-sensing In-water sensing In-water autonomous analysis Ship- or station-based autonomous.
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
Other Electrochemical Methods
Inactivation of Wine Spoilage Yeasts Dekkera bruxellensis Using Low Electric Current Treatment(LEC ) Kenneth, Eriko, Zach, Jihee.
Solubility and Concentration Chemistry Mrs. Coyle.
PPM (parts per million) PPM = grams solute X 1,000,000 PPM = grams solute X 1,000,000 used when solute is present in very small amounts (The Regents don.
Field Analytical Methods. Considerations for Field Analytical Methods Which parameters are anticipated to occur at the site? What media will be analyzed?
Ecosystem Productivity. Assessment Statements 2.5.2: Describe photosynthesis and respiration in terms of inputs, outputs and energy transformations :
Ammonia Measurement Techniques Ji-Qin (Jee-Chin) Ni, Ph.D. Dept. of Agricultural and Biological Engineering Purdue University October 21, 2008 Albuquerque,
Introduction to Oxidation in Wine Andrew L. Waterhouse Department of Viticulture & Enology University of California, Davis.
Solutions Applied Chemistry 4.0. Background to Solutions  A solution is a homogenous mixture that has different substances dissolved in it that cannot.
By Dominic Lanni. Part One Introduction  What are biosensors?  A device that uses a living organism or biological molecule to detect things  Usually.
Electrochemistry Electrolysis Electrolytic Cells An electrolytic cell is an electrochemical cell that undergoes a redox reaction when electrical energy.
Pre-Lab AP Lab #12. Ecosystem Studies 1. Energy Flow 2. Chemical Cycling AP Lab #12 we will be able to study both cycles.
What do Fish Want?? The importance of Water Quality and Testing Water.
Oxygen Permeation Measurements Across Films using OxySense® luminescence Technology Devinder Saini OxySense Inc S. Eastern Ave Suite 14G Las Vegas,
By Dominic Lanni. Part One Introduction  What are biosensors?  A device that uses a living organism or biological molecule to detect things  Usually.
Chapter 16.  the chemical principles, half-equations and overall equations of simple electrolytic cells; comparison of electrolytic cells using molten.
U2 S3 L2 Titration page 603: Acid-Base Titration pages : Titration Step by Step page 838: Precision, Error and Accuracy Questions page 616: items.
Working Group: Seawater Carbonate Chemistry Common themes, considerations and issues: existing established best practices for methods (Dickson et al.,
Workshop synthesis Robert Judd General Secretary GERG GERG/MARCOGAZ Gas Sensor Workshop, Brussels, 27th February 2014.
Wine Flavor 101B Introduction to Native Fermentations.
Water Quality Anyalysis.  Why analyze nitrate?  High concentrations of nitrate indicate high levels pollution, and promote the growth of algae.  Concentrations.
Metal Nanoparticle Hydrogen Sensor
Tel: +44 (0) Dissolved Oxygen.
Solutions Applied Chemistry 4.0. Background to Solutions  A solution is a homogenous mixture that has different substances dissolved in it that cannot.
O2 and CO2 levels in blood.
oak ageing alternatives
Electrochemistry MAE-212
Electrolytic Cells.
VARIOUS LABORATORY INSTRUMENTS IN ACC
PH pH ph pH = power of Hydrogen
Electrochemistry and The Chemical Cells.
Basic Laboratory Equipment for Biology Class
Electrode Training HORIBA Instruments, Inc. Pamela Millett Scientific
Electrochemistry.
Dissolved Oxygen in the Marine Environment
Water Pollution.
Prepared by the EPSRC CDT in Sustainable Chemistry
Redox in Electrochemistry
Presentation transcript:

Oxygen and wine Wes Ward April 2013

Make Break Oxygen and wine Impacts depend on: Micro-organism growth Period of addition Oxygen amount pH SO2 Temperature Etc… Color stability Reduction of astringency Browning Organoleptic defaults Micro-organism growth Aroma profile evolution

Measurement application domain Why measuring? Assessing winemaking steps Controling at different oxygen amounts (macro/micro/nano) Assessing consistency Must Preparation Maturation (barrel aging, micro-oxygenation) Bottling (TPO) & Bottle Aging (OTR) Degree of Oxygen Exposure

Mapping the process and defining strategies Objectives Mapping the process and defining strategies source Oenomeca Process Mapping HACCP

Electrochemical methods Generated current is proportional to O2 partial pressure or to mass of O2 transformed during electrolysis Circulation in the cell Destructive method Need of inert gas Portable Very Accurate 1 point calibration HS measurement possible

Luminescence Methods Immersion Stirring in the tank Non-destructive Non-invasive depending on device and brand Very Accurate No calibration Portable

Main Measurement Methods Principle Pros Cons NomaSense Oxysense Ocean Optics Non-Invasive Luminescence Accurate Easy to use DO, HS, TPO Orbisphere Clark Electrode Electrochemistry Accurate for DO Responsive Difficult to use HS not accurate Hach Lange LDO Cheap No HS Only DO in tanks Oxybaby Checkmate Amperometry O2 and CO2 Only HS, no DO

YSI - Probe Method – Electro-chemistry Evasive Somewhat Portable Can measure both Dissolved O2 Only Detection Limit of .001 ppm (1ppb) Detection Limit - 0–20ppm Accuracy +/- .01ppm No cross sensitivity to C02 or SO2 Food Certified Primary Industry – Water

Oxybaby Method – amperometry – probe only Invasive – probe only Portable Cannot measure Dissolved O2 Can measure Headspace O2 only No In-line measurement Detection Limit of .1% O2 Detection Limit – 0-100% O2 Accuracy .10% No cross sensitivity to C02 or SO2 Headspace only with Bag-in-Box applications Not food certified, probe only Primary Industry – Food Packaging

Orbisphere Method – Electro-chemistry – no dipping probe Invasive Portable, but usually fixed (lab application) Can measure Dissolved O2 Extremely difficult to measure headspace O2 In-line only Detection Limit of .001 ppm (1ppb) Detection Limit – 0-20ppm Accuracy <= 1% of reading No cross sensitivity to C02 or SO2 Ability to measure Bag-in-Box applications Not food certified, it is a destructive test Primary Industry - Beverage

Hach Ultra LDO Method – Luminescence – dipping probe only Invasive Portable Can measure Dissolved O2 – No HS In-line not possible Detection Limit of .001 ppm (1ppb) Detection Limit – 0-20ppm Accuracy <= .2ppm Low sensitivity to C02 or SO2 Not able to measure with Bag-in-Box applications Not food certified, it is a destructive test Primary Industry – Waste Water

Oxysense Method - Luminescence – sensor spots, Non-invasive Not truly portable Can measure Dissolved O2 & Headspace O2 Can measure In-line Detection Limit of .015 ppm (15ppb) Detection Limit – 0-15ppm Accuracy <= 5% of reading Cross sensitive to C02 or SO2 Light interferences Bag-in-Box applications possible Not food certified Primary Industry – Food Packaging

Ocean Optics – Neofox Method – Luminescence – sensor spots & dipping probe Non-Invasive Portable, but requires a PC to read Can measure Dissolved O2 & Headspace O2 In-line ability Detection Limit of .04 ppm (40ppb) Detection Limit – 0-40ppm Accuracy <= 5% of reading Cross sensitivity to C02 or SO2 is unknown Sensors susceptible to ethanol Bag-in-Box applications possible Not food certified Primary Industry – Waste Water

NomaSense Method – Luminescence (sensor spots & dipping probe) Non-destructive & Non – Invasive Very Portable Can measure both Dissolved O2 & Head Space O2 Can measure in-line Detection Limit of .001 ppm (1ppb) Detection Limit - 0–40ppm Accuracy <= .01ppm No cross sensitivity to C02 or SO2 Ability to measure Bag-in-Box applications Food Certified CIP possible Primary Industry – Wine Fully validated for wine applications

Validation procedure Certified gases (GEC) ranging from 0 to 21% O2 Experimental set-up for both Head space and dissolved oxygen Procedure MA-F-AS1-06-PROVAL recommended by the OIV  Linearity, repeatability, reproducibility LOD, LOQ, selectivity and accuracy

Elements of validation m-GC NomaSense Orbisphere All technologies are very accurate NomaSense showing the best performances Broader range of application for NomaSense

Available tools Sight Glass Dipping Probe Analyzer Side Glass Sensors Transparent BIB taps

Different measurement approaches Dipping Probe Sight Glass Sensors

How much oxygen is in the bottle? Measuring in a bottle Headspace How much oxygen is in the bottle? Dissolved 19

Selected Audit Results

Bottling Consistency O2 difference of 0.90 ppm O2 42

Typical DO Evolution in Bottles

Inerting before Filling Without Inerting With inerting Inerting before filling can reduce up to 0.5 ppm

Head Space Management for Inner Seals No Vacuum Pick-up = 3ppm Vacuum: Pick-up= 1.4 ppm Vacuum + CO2 Pick-up = 0.2 ppm HSO in hPa

The New NomaSense O2 analyzer

The New NomaSense O2 analyzer 2nd Generation NomaSense Overall reduction in size & weight More intuitive user interface New calibration management through bar code reading New sensor management via new file structure Compatible with existing sensors and accessories The only TPO meter on the market No need to run separate calculations in excel files