MEETING TC 4-15 “Road Lighting Calculations, Test Data and Measurement” 16 May 2005 / Leon.

Slides:



Advertisements
Similar presentations
LAMPS (Chapter 3) Lamp efficacy, life, and color Incandescent
Advertisements

16469 Low Energy Building Design Lighting Cameron Johnstone Department of Mechanical Engineering
Lecture 3 Sunday, 03 May ENGINEERING GRAPHICS 1E7 Lecture 3: Orthographic Projections.
16469 Lighting and Daylighting Design. Energy Efficient Lighting Lighting accounts for a significant portion of energy use in commercial buildings We.
Angles of Elevation and Angles of Depression
Lighting Calculations
 Old stuff will be used in this section › Triangle Sum Theorem  The sum of the measures of the angles in a triangle is 180° › Pythagorean Theorem 
Evaluating Roadway Lighting Systems Using Unit Power Density
WFM 6202: Remote Sensing and GIS in Water Management
Lecture 3 Sunday, 14 June ENGINEERING GRAPHICS 1E9 Lecture 2: Orthographic Projections.
Introduction to Perspective Projection. Perspective Projection is a geometric technique used to produce a three- dimensional graphic image on a plane,
ENGINEERING GRAPHICS 1E7
Theory of Retinoscopy.
Section 3.6 Variation. Direct Variation If a situation gives rise to a linear function f(x) = kx, or y = kx, where k is a positive constant, we say.
Chapter 6: Trigonometry 6.2: Trigonometric Applications
Practical I - A. Crystallographic axis  One of three lines (sometimes four, in the case of a hexagonal crystal), passing through a common point, that.
1. A man flies a kite with a 100 foot string
Lighting calculations
Chapter 17: Reflection & Mirrors Honors Physics Bloom High School Mr. Barry Latham.
Angles of Elevation and Depression 8-4 Holt Geometry.
Principal maxima become sharper Increases the contrast between the principal maxima and the subsidiary maxima GRATINGS: Why Add More Slits?
FUNDAMENTALS OF HAIR CUTTING
Algebra, Functions and Patterns AIMS Prep. The Jones family is planning to average 55 mph on their vacation. The travel time (t) is determined by the.
1 Lighting Learning outcome from this topic, the student is able to – recognize the definitions and meanings for terms used in lighting – calculate lighting.
Precalculus Unit 2 (Day 12). Knight’s Charge 9/9/15 1. Find the value of θ. 2. Find the value of h. 3. Find the value of z. 4. Find the value of x.
Chap 16-1 Light Fundamentals.
Chap 16-1 Light Fundamentals. What is Light? A transverse electromagnetic wave.
DAYLIGHT CALCULATIONS. Components of the Natural Light :  There are three separate components of the natural light that reaches any point inside a building:
Copyright © 2009 Pearson Education, Inc. CHAPTER 2: More on Functions 2.1 Increasing, Decreasing, and Piecewise Functions; Applications 2.2 The Algebra.
Wave superposition If two waves are in the same place at the same time they superpose. This means that their amplitudes add together vectorially Positively.

Presented by RAMA KRISHNA RAO AD KV, PICKET. QNo. From a point 100m above a lake, the angle of elevation of a stationary cloud is 30 0 and the angle.
Lecture 2: 2-D Transformation and Projection Multi-view Drawing
1© Manhattan Press (H.K.) Ltd. Young’s double slit experiment Young’s double slit experiment 9.10 Interference of light waves Relationship between x,,
MEMB Multiview Projection Drawing. adzlyanuar © 2004 MEMB113 | Dept. of Mechanical Engineering | UNITEN | MULTIVIEW PROJECTION DRAWING Content.
Modern Optics Lab Lab 8: Diffraction by Periodic and Non-Periodic Structures  Transmission grating spectrometer: Measuring and calculating the angular.
Waves and Energy Transfer 14.1 Wave Properties Wave A repeating disturbance or movement that transfers energy through matter or space.
Straightness measurement
Light: Geometric Optics. The Ray Model of Light The ray model of light assumes that light travels in straight-line path called rays.
THE IMPACT OF CIE 140 ON STREETLIGHTING IN SOUTH AFRICA AMEU CONVENTION: DURBAN: OCTOBER 2007 AUTHOR:- MURRAY CRONJE, BEKA (PTY) LTD.
Modular structure enables wide compatibility and easy modification
Multi-view Projection Drawing
Transmitted by the expert from GTB Informal Document No. GRE (64th GRE, 4-7 October 2010, agenda item 5(f)) Proposal for Amendments to Regulations.
Holt Geometry 8-4 Angles of Elevation and Depression 8-4 Angles of Elevation and Depression Holt Geometry Warm Up Warm Up Lesson Presentation Lesson Presentation.
1 ALTERNATIVE CO-ORDINATES SYSTEM FOR AFS DRAFT REGULATION Tomasz Targosiński Poland This document is distributed to the Experts on Lighting and Light-Signalling.
Objective To use angles of elevation and depression to solve problems.
Light Waves Physics 1 L Mrs. Snapp. Light Light is a transverse wave. Light waves are electromagnetic waves--which means that they do NOT need a medium.
As regards the formation of an image by an optical system such as a plane mirror, what will serve as an object? a) An emitter of light, such as, a candle.
SECTION 8 - RACKING (BRACING) AND SHEAR FORCES STUDENT HANDOUT
Incandescent Light Bulb LUMEN DESIGN METHOD Where: N = E A F UF LLF N = number of lamps E = level of illuminance A = Area at working plane.
Objectives Use trigonometry to solve problems involving angle of elevation and angle of depression.
National Traffic Safety and Environment Laboratory
Physics 1 H Created by Ingle
STRADA-2X2MX-SCL Supreme reach with 75-degrees intensity peak
STRADELLA family Mid power street lighting
METHODS OF ILLUMINANCE CALCULATION
Profile Leveling.
Evaluation and design of road lighting
Wave superposition If two waves are in the same place at the same time they superpose. This means that their amplitudes add together vectorially Positively.
Wave superposition If two waves are in the same place at the same time they superpose. This means that their amplitudes add together vectorially Positively.
CORE AREA K. F. Chan (Mr.) MEBS6002.
ILLUMINATION.
8.4 Angles of Elevation and Depression
MD - Euro NCAP lighting.
Waves and their properties
Analysis of the Polish proposal. GRE2016/18
Construction Studies Resources
Identify Pairs of Lines and Angles
Light Waves, Mirrors and Reflection
Regulation No. 148 [LSD] – Stage II Side Parking lamps
Presentation transcript:

MEETING TC 4-15 “Road Lighting Calculations, Test Data and Measurement” 16 May 2005 / Leon

STEPS 1.Selection of the right luminaire from I-Tables that is suitable for your computer program. 2.Comparison between R3 table of your own and in the CD. 3.Determination of calculation field, calculation points and observer position according to CIE Calculation of Illuminance (E) and Luminance (L) for 7 situations of lighting arragements. (Maintanance factor = 1) TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon STEPS 1.Selection of the right luminaire from I-Tables that is suitable for your computer program. 2.Comparison between R3 table of your own and in the CD. 3.Determination of calculation field, calculation points and observer position according to CIE Calculation of Illuminance (E) and Luminance (L) for 7 situations of lighting arragements. (Maintanance factor = 1)

I - Tables

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon STEPS 1.Selection of the right luminaire from I-Tables that is suitable for your computer program. 2.Comparison between R3 table of your own and in the CD. 3.Determination of calculation field, calculation points and observer position according to CIE Calculation of Illuminance (E) and Luminance (L) for 7 situations of lighting arragements. (Maintanance factor = 1)

Road Surface Classification Table

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon STEPS 1.Selection of the right luminaire from I-Tables that is suitable for your computer program. 2.Comparison between R3 table of your own and in the CD. 3.Determination of calculation field, calculation points and observer position according to CIE Calculation of Illuminance (E) and Luminance (L) for 7 situations of lighting arragements. (Maintanance factor = 1)

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon STEPS 1.Selection of the right luminaire from I-Tables that is suitable for your computer program. 2.Comparison between R3 table of your own and in the CD. 3.Determination of calculation field, calculation points and observer position according to CIE Calculation of Illuminance (E) and Luminance (L) for 7 situations of lighting arragements. (Maintanance factor = 1)

Lighting Arrangement:Single sided “left” Spacing:20 m Road width: 10 m Number of lane:2 Montage height:4 m Overhang:2 m Tilt angle: 0° Light source: 24 W / 1800 lm / CFL

Lighting Arragement:Straggered Spacing:20 m Road width: 10 m Number of lane:2 Montage height:4 m Overhang:2 m Tilt angle: 0° Light source: 24 W / 1800 lm / CFL

Lighting Arragement:Single sided “left” Spacing:45 m Road width: 7.5 m Number of lane:2 Montage height:10 m Overhang:0 m Tilt angle: 5° Light source: 100 W / lm High Pressure Sodium L.

Lighting Arragement:Staggered Spacing:35 m Road width: 7 m Number of lane:2 Montage height:8 m Overhang:0 m Tilt angle: 5° Light source: 100 W / lm High Pressure Sodium L.

Lighting Arragement:Opposite (with 1.5 m of central reservation) Spacing:54 m Road width: 10.5 m Number of lane:2 Montage height:12 m Overhang:0 m Tilt angle: 5° Light source: 100 W / lm / HPS

Lighting Arragement:Central, twin brackets Spacing:75 m Road width: 7 m Number of lane:2 Montage height:18 m Overhang:0 m Tilt angle: 5° Light source: 250 W / lm / HPS

Lighting Arragement:Single sided “left” Spacing:40 m Road width: 8 m Number of lane:2 Montage height:10 m Overhang:0 m Tilt angle: 5° Light source: 90 W / lm Low Pressure Sodium L.

Calibration Intervals for Luminance and Illuminance Values TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon The results of Calculations According to CIE 30.2

In the (c;  ) system of coordinates, luminous intensities will be required at the angular intervals stated below. For all luminaires the angular intervals in elevation (  ) should at most be 2.5 from 0° to 90° plus the permissible maximum field angle of elevation minus the measurement angle of elevation, for the luminaire. In azimuth the intervals can be varied according to the symmetry of the light distribution from the luminaires as follows: - Luminaires with no symmetry about c = 0° – 180° plane; the intervals should at most be 5°, starting at 0°, when the luminaire is in its measurement angle of elevation and ending at 355°. TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon Following statements take part in CIE 140 (page: 5);

I-table of road lighting luminaire with no symmetry light distribution should be given according to those definitions. TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon Road Surface Reflection Data

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon Position of Calculation Field According to CIE 140

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon The results of Calculations According to CIE 140

According to CIE 140, the observer’s eye height 1.5 m above road level, is positioned transversely a quarter of road width from the carriageway edge, and longitudinally at a distances in meters of 2.75 (mounting height: 1.5) in front of the field of calculation. In EN13201 Part: 3, it is stated that “the observer’s eye, is positioned in the centre line of each lane in turn” by keeping all other parts same. TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon

TC 4-15 “Road Lighting Caculations, Test Data and Measurement” 16 May 2005 / Leon The results of Calculations According to EN 13201