AC 650 the NEW 650 series ac inverters beauty in simplicity...

Slides:



Advertisements
Similar presentations
LG Inverter iG5 , iS5 , iH , iV5 Series
Advertisements

Power plus Performance
Variable Frequency Drives Bypass Options
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.
3200 Controllers and Indicators. 2 Eurotherm Business Group 3200 Key Features Easy to configure Simple operation Adaptable features.
E300 Series Mini-type Integrated Universal Inverter
Movitrac LTP A General purpose frequency inverter.
KEB COMBIVERT F5-M Exercises.
ABB standard drive Enhanced ACS550
ABB standard drive ACS550.
Internal | 01/22/2013 | DC-IA/SFS31 | Carsten Kobusch | Rexroth Parameter Training EN V1.0 | © Bosch Rexroth AG All rights reserved, also regarding.
AC Inverter Drives 500 Series Product Range Overview 2000 AC Inverter Drives.
NX Variable Frequency Drives Perfect match for HVAC Field Devices All you need in HVAC Control.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Delta AC Motor Drives Arnoud de Bok / April 2012.
A TECHNICAL PRESENTATION BY: ERIC BABSKI Controlling Electric Motors.
Application Types Variable Torque Constant Torque.
ATV71-ATV61 for DH Bach Khoa
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Delta Confidential VFD-E Features Sensorless vector control Built-in filter for all models (except 230VAC 3-phase) RFI-switch Option PG-card (closed-loop)
Motor Starting Technologies
Mini8 Multi-loop Controller. 2 Eurotherm Business Group Mini 8 – What is it? Multi-loop(4,8,16) PID controller 8-32 Channel data acquisition Design targeted.
Introduction for TECO SERVO 9300 Series
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
I Pag 1 Microchiller 2. I Pag 2 I Pag 3 Information on the display.
ENERGY of 21 st Century Independent Power Supplies.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
Confidential / Property of Danfoss Drives A/S DD-SMT/DEJ 1 Drives Division VLT ® AutomationDrive FC302 PM Motors Configuration procedure By:
1 Chang Shuan Eletronics Co., Ltd
MonoDrive & XT Constant Pressure Controller
VTAC 9 AC Drive Firmware Version 3.xx
Modular Inverter.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
CUE – Make Any Pump an E-Pump
Service Section Technical Training December 2005.
1 Chang Shuan Electronics Co., Ltd
Programmable Controllers - ECL/ECB
Pag. 1 VAT200, General Purpose AC Drive Mini AC Drive VAT200.
AC Drive Products AC Drive Products PP.AFD.23.Products 4/20/04.
Review of How Motor Works
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
Reliability in motion ™ Copyright © 2010 Toshiba International Corporation. All rights reserved Welcome.
This presentation is driven by the mouse or pointing device.
FUJI ELECTRIC CO.,LTD Power Electronics Business Group Drive Division
“The Industrial Workhorse”
INTRODUCING….
FR200L & Wire Drawing Machine
MEDIUM VOLTAGE APPLICATIONS.
Altivar 61 Energy savings & performance in your fluid management solutions from 0.37 up to 2400 kW 3 phases : 240 / 480 / 690 V for Pumps & Fans control.
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
No. THE E-SERIES AC DRIVE.
FEEDER PROTECTION UNIT
Moving your Control Forward - VFD from Unitronics
FR200L & Wire Drawing Machine
Moving your Control Forward - VFD from Unitronics
easYgen-3000XT Series Training
Principio de Aplicación – CR-II
Presentation transcript:

AC 650 the NEW 650 series ac inverters beauty in simplicity... Ratings from 0.2 - 90kW

AC 650 … simple to install … simple to set-up … simple to operate no programming languages to learn easy to navigate menu ready-to-go from the box

AC 650 small in size… … long on features built-in EMC compliant filters (up to 7.5kW, footprint >7.5kW) DIN rail or direct panel mounting (up to 7.5kW) pre-programmed applications

1 2 3 AC 650 3 2 1 3 new compact frames 230V 1ph .2kW .37kW .55kW H W D (mm) 137 73 142 192 73 173 257 96 195 3 230V 1ph 400V 3ph .37kW 1.1kW .55kW 1.5kW .75kW 1.1kW 1.5kW 2.2kW 2 2 3 400V 3ph 3.0kW 4.0kW 5.5kW 7.5kW 1

AC 650 3 2 F E D C 1 above …7.5kW …up to 7.5kW All New Bookshelf Frames 55(75)-90(110) KW 15(18.5)-22(30) KW 30(37)-45(55) KW 11(15) KW C D E F above …7.5kW 380-460V 3.0-7.5 KW 3 2 1 230V 1.1-1.5 KW 380-460V .37-2.2 KW 230V .25 -.75 KW 380-460V (Ratings In Brackets) = Quadratic “Fan” Torque …up to 7.5kW

AC 650 flexible inputs & outputs CONTROL POWER ONE option provides two features - Remote-mount keypad together with P3 comms port CONTROL POWER volt-free relay contacts digital I/O 8 presets 2 programmable I/O motor thermistor AC line input analogue I/O 0 - 10V or 4-20mA input 1 programmable output for load or speed motor

AC 650 simple operator controls Backlit LCD display Speed, Hz, or units Rotation local /remote START STOP Locally mounted & removable or Remote-mount option raise / lower speed program menu

AC 650 simple & easy ...for all your applications VT (Variable Torque) CT (Constant Torque) material conveyors fans & blowers batch mixers centrifugal pumps

AC 650 simple tuning for your load type Selectable v/f curves match your load requirement VT CONSTANT TORQUE VARIABLE TORQUE V f Vbase CT fbase

AC 650 simple programming Application selection parameter! Directions on cover back Application selection parameter! Menu navigation Set-up parameters Diagnostics Fault codes

AC 650 simple application programming Applications 1 p basic speed control 01 automatic/ manual 02 preset speeds 03 raise/ lower 04 PI control 05 STANDARD PARAMETERS Application 3, preset speeds p301 Preset 0 Application 5, PI p1 APPLICATION (1-5) : : p501 P gain p2 Max speed p3 Min Speed p308 Preset 7 p502 I gain p4 Accel time p5 Decel time p6 Motor rated current Application 2, automatic/manual - STANDARD PARAMETER LIST - with auto / manual control input selection p7 Base frequency Application 4, raise/lower p8 Jog setpoint p401 Ramp time p9 Stop mode p402 Max value p11 V/F shape p12 HVAC ratings p403 Min value p13 Fixed boost, (VF only) p404 Reset value p99 Password

AC 650 menu structure DIAG Diagnostics PAR Parameters SET Setup IN APPLICATION (1-5) p2 Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS d1 Frequency (Hz) IN Inputs TRIP Disabled Trips (p1=1) d2 Speed setpoint (%) IP01 Digin 1 invert LOOP Anin2 input break d3 DC Link volts(v) IP02 Digin 2 invert T 3 Anin2 overload d4 Motor current (A) IP03 Digin 3 invert STLL Stall IP04 Digin 4 invert OT Motor over temp IP11 Anin 1 scale DB R Brake resistor IP12 Anin 1 offset DB S Brake switch IP13 Anin 1 type OP Op station IP21 Anin 2 scale IP22 Anin 2 offset SET Setup IP23 Anin 2 type ST01 Jog accel time APPLICATION PARAMETERS OUT Outputs ST02 Jog decel time p1 = 2 OP01 Anout select Application 2, automatic/manual ST03 Ramp type - STANDARD PARAMETER LIST - OP02 Anout scale ST04 S-ramp jerk OP03 Anout offset Application 3, presets p301 Preset 0 : p308 Preset 7 ST05 S-ramp continuous p1 = 3 OP04 Anout abs APPLICATIONPARAMETERS appear only when selected OP11 Digout 1 select ST11 Skip frequency 1 OP12 Digout 1 invert ST12 Skip freq band 1 OP21 Digout 2 select ST13 Skip frequency 2 Application 4, raise/lower p401 Ramp time p402 Max value p403 Min value p404 Reset value OP22 Digout 2 invert ST14 Skip freq band 2 p1 = 4 OP31 Relay select ST21 Auto restart attempts OP32 Relay invert ST22 Auto restart delay ST23 Auto restart triggers SERL Serial Comms ST24 Auto restart triggers+ p1 = 5 Application 5, PI p501 P gain p502 I gain SE01 Remote comms sel ST31 Dynamic brake enable SE02 Comms timeout ST32 DB resistance SE03 Address ST33 DB power SE04 Modbus baud rate SE05 Modbus parity ST34 DB over-rating

Application 1 : Basic Speed Control Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 1 IDEAL FOR GENERAL PURPOSE APPLICATIONS, CONSTANT TORQUE AND VARIABLE TORQUE d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS P2 MAX SPEED Feedback 4-20mA P4 ACCEL TIME IP23 AIN2 TYPE 0 0-10V 1 0-5V 2 0-20mA 3 4-20mA IP13 AIN1 TYPE 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 MIN/MAX SPEED 1 2 3 4 5 6 7 8 9 10 REFERENCE SELECT P8 JOG SPD RAMP FWD/REV SPEED DEMAND Ref. P3 MIN SPEED OP01 ANOUT P5 DECEL TIME 0 NONE 1 DEMAND% 2 CURRENT% 3 PID ERROR% 4 RAISE/LOWER% P9 STOP MODE SEQUENCING LOGIC 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP21 DIGIO2 I FDBK START V/F SHAPING CURRENT LIMIT PWM CONTROL V FWD/REV V V JOG CT VT F F F STOP 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

Application 2 : Auto / Manual Control Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 2 IDEAL FOR AUTOMATIC CONTROL APPLICATIONS WITH LIMIT SWITCHES OR PROXIMITY TRANSDUCERS d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS MIN/MAX SPEED P2 MAX SPEED P3 MIN SPEED P4 ACCEL TIME AUTO REF IP13 AIN1 TYPE REF SELECT 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 1 2 3 4 5 6 7 8 9 10 0 0-10V 1 0-5V RAMP FWD/REV IP23 AIN2 TYPE SPEED DEMAND MAN. REF 0 0-10V 1 0-5V 2 0-20mA 3 4-20mA P5 DECEL TIME P9 STOP MODE P9 STOP MODE SEQUENCING LOGIC 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP21 DIGIO2 MAN. RUN I FDBK V/F SHAPING CURRENT LIMIT PWM CONTROL V AUTO RUN V V CT MAN./AUTO RUN SELECT VT F F F FWD / REV 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P6 I RATED RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

Application 3 : Preset Speeds Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 3 IDEAL FOR APPLICATIONS WHERE MULTIPLE DISCRETE SPEED LEVELS ARE REQUIRED d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS (SCALABLE) IP300 PRESET 0 IP301 PRESET 1 IP302 PRESET 2 IP306 PRESET 6 IP305 PRESET 5 IP304 PRESET 4 IP303 PRESET 3 IP307 PRESET 7 AUTO REF MIN/MAX SPEED P2 MAX SPEED P3 MIN SPEED P4 ACCEL TIME 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 1 2 3 4 5 6 7 8 9 10 RAMP FWD/REV SPEED DEMAND SPEED DEMAND MAN. REF P5 DECEL TIME DIGIO2 DIGIO1 DIN2 PRESET 0V 24V 1 2 3 4 5 6 7 START/STOP I FDBK V/F SHAPING CURRENT LIMIT PWM CONTROL V PRESET IN V V CT VT PRESET IN F F F PRESET IN SEQUENCING LOGIC 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P9 STOP MODE P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

Application 4 : Raise/Lower Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 4 IDEAL FOR APPLICATIONS WHICH REQUIRE SPEED CONTROL FROM MULTIPLE LOCATIONS d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS MIN/MAX SPEED P2 MAX SPEED P3 MIN SPEED P4 ACCEL TIME 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 1 2 3 4 5 6 7 8 9 10 RAISE / LOWER RAMP FWD/REV SPEED DEMAND SPEED DEMAND P5 DECEL TIME SEQUENCING LOGIC START/STOP P401 RAMP TIME I FDBK V/F SHAPING CURRENT LIMIT PWM CONTROL P402 MAX VALUE V RAISE V V P403 MIN VALUE CT VT LOWER P404 RESET VALUE F F F RESET 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P9 STOP MODE P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

Application 5 : PID Control Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 5 EASY TUNING FOR SETPOINT/ FEEDBACK CONTROL APPLICATIONS, REGULATING VOLUME OR PRESSURE, SUCH AS AIR HANDLING OR PUMPING d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS P501 P GAIN P502 I GAIN P2 MAX SPEED P4 ACCEL TIME Feedback 4-20mA 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 PID CONTROL MIN/MAX SPEED 1 2 3 4 5 6 7 8 9 10 REFERENCE SELECT P8 JOG SPD RAMP FWD/REV SPEED DEMAND Ref. P3 MIN SPEED OP01 ANOUT 0 NONE 1 DEMAND% 2 CURRENT% 3 PID ERROR% 4 RAISE/LOWER% P5 DECEL TIME SEQUENCING LOGIC I FDBK START V/F SHAPING CURRENT LIMIT PWM CONTROL V FWD/REV V V JOG CT VT F F F STOP 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P9 STOP MODE P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

AC 650 mount more drives per cabinet! VENTILATION DIN rail mount on frames 1-3 No side ventilation allows for zero clearance between drives! VENTILATION

AC 650 the NEW 650 series ac inverters simple… smart… easy…

AC 650 the NEW 650 series ac inverters Thank you for your attention. Any Questions ?