The I 2 Air Fluid Protocol; The Eco-friendly method for eliminating bio-fouling in heat exchangers and cooling towers utilizing I 2 infused mixed media.

Slides:



Advertisements
Similar presentations
Chapter 24 Dental Unit Waterlines
Advertisements

Non Chemical Descaling and Debottlenecking Systems
Corrosion Products Sampler (CPS)
I 2 Air Infuser. CONFIDENTIALITY STATEMENT: This presentation, including all attachments, is confidential and/or may include proprietary content or intellectual.
Bacterial reduction in water and surfaces using the I 2 Air Infusion method. Click to continue.
Functional benefits for heat exchangers cleaned with I 2 Air Infusion. Click to continue.
1 Seair Diffusion Systems Inc. Pulp & Paper Solutions June 2009.
Basic Refrigeration Cycle
DRIP DISPERSAL SYSTEMS Problems and Solutions. Flow Equalization Surges in the ATU during peak loading are a major cause of filter clogging in a drip.
100% Natural – 100% Effective FOG Elimination Program.
Chilled Water, Hot Water, Heat Pump and Glycol Loops
Anthium Dioxcide Presents The Future of Disinfection.
Surface Water Treatment Plant
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Heat pumps and their economics. There has been fluctuations before Johnson Controls2.
Drug Delivery & Tissue Engineering Laboratory
The SR Scale Remover For Cooling Water Treatment Without Chemicals.
LESSON FOURTEEN. WATER COOLING SYSTEM 1.HEAT SOURCES.
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Chapter 3: Bioreactor Design
The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
Microbial Ecology Ecology: interactions among living things and their environments Think globally act locally: microbes metabolize in microenvironments,
Microbial Ecology Ecology: interactions among living things and their environments –Think globally act locally: microbes metabolize in microenvironments,
Cleaning and disinfection a summary FS
Chemical BacComber Scale and Bacteria Control Comparison Between
COMMERCIAL REFRIGERATION
Heat exchangers The device at which heat exchange between two fluids at different temperatures and separated by a solid wall occurs is called heat exchanger.
What am I looking at?  This is an ecological-machine that reduces water consumption in the Aiken Center by treating the building’s sewage and then returning.
Cold-Plus™ Refrigerant Enhancer
Cold-Plus™ by TRIFECTA DISTRIBUTORS LLC
BCE Environmental Engineering Water Treatment Mdm Nur Syazwani binti Noor Rodi.
Geothermal Energy Chelsey Haske Taryn Mulienburg Jenny Sobecki Taylor Bourne.
Air Compressors.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Steam Traps Function and Types.
Sustainable Management Resources Inc Join SMRI as we work on: “Creating a Sustainable New Economy” SMRI, San Diego CA, ~ ~ Steve Kaplan ~
INTRODUCTION Definition:
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Northvale Korting Fluid Jet Theory and Applications of Eductors By Patrick Belcher.
Mazzei Injector Company, LLC
Cleaning & Sanitizing for Food Plants. 22 Dec 07Effective Cleaning2 Introduction All equipment must be cleaned and sanitized prior to use and following.
Benefits of Microbial Treatments for Improved Oil &Gas Production.
Heating Systems.
Advanced Aeration, Inc. Presentation of Vacuum Bubble ® Technology.
UNIT THREE: Matter, Energy, and Earth  Chapter 8 Matter and Temperature  Chapter 9 Heat  Chapter 10 Properties of Matter  Chapter 11 Earth’s Atmosphere.
WATER COOLING SYSTEM. 1.HEAT SOURCES  Burning of fuel  Heat developed by compression of air  Frictional heat.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers utilizing I 2 infused mixed media.
The Nature of Solubility
Introduction to Energy Management. Week/Lesson 9 part a Evaporative Cooling and Cooling Towers.
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
FLOTATION. INTRODUCTION Flotation is an operation that removes not only oil and grease but also suspended solids from wastewaters. Flotation is an operation.
NH International (Caribbean) Ltd Penal Rock Hindu School Presented by : Sudesh Ramroop.
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Chapter 7 Energy and Power for Technology Unit 2 Energy and Power Technologies.
Overview of HVAC Filtration
EnRoll NO. EnRoll NO Department: Computer Science & Engineering.
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
What is Degassing? Degassing is removing dissolved gases from liquids. Applications includes: Removing biogenic hydrogen sulfide from groundwater, used.
Dynamics Seminar Section 7 Batch Reactors John Edwards, P&I Design Ltd
Case sample of a CT option
Risk Assessment should include:
Sewage Treatment.
Energy Conservation Through the Removal of Bio-film
Bacterial reduction in water using the
Functional benefits for heat exchangers cleaned with I2 Air Infusion.
12. Heat Exchangers Chemical engineering 170.
Presentation transcript:

The I 2 Air Fluid Protocol; The Eco-friendly method for eliminating bio-fouling in heat exchangers and cooling towers utilizing I 2 infused mixed media.

The I 2 Air Fluid Protocol; Michael Radicone

CONFIDENTIALITY STATEMENT: This presentation, including all attachments, is confidential and/or may include proprietary content or intellectual property. This presentation is intended for the sole use of the individual(s) or entity being presented to. If you have received this presentation by mistake, please notify the sender by immediately and delete this message from your system. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the contents of this information is strictly prohibited. Protocol and application is based upon the art and science of U.S. Patent No. 7,329,385 and is the intellectual property of the inventor(s).

The Problem Heat exchangers and cooling towers are found in many industries. The efficiency of any exchanger can be compromised when geo-thermal wells or cooling towers become contaminated by bacteria. Iron, sulfur and other species of bacteria adhere to the walls of the exchanger forming a gelatinous coat of bio- film reducing heat transfer. Occluded space increases temperature and pressure through decreased flow within the geothermal or cooling tower side of the heat exchanger. Insulating matter on the plates impedes heat transfer. Bio-toxin corrosion on plate surfaces reduces the plate heat transfer coefficient. Bio-film and planktonic bacteria can move downstream to occlude screens. In cooling towers, bio-slime coats surfaces and pathogenic bacteria such as legionella are released into the air. Additional energy use and increased green house gas discharge is associated with ineffective heat exchanger function. Labor associated with exchanger maintenance is costly.

The Answer is The APF Cleaning Protocol and I 2 Air Infused mixed media. The APF protocol cleans the surfaces of the heat exchanger and cooling towers. A once a month procedure that requires less than one hour per month labor time and no disassembly of the exchanger. It does not expose the staff to caustic chemicals or biofilms.

Throughout the month, the plate walls are continually bathe in extremely low dose I 2 bubbles which keep bio-films from forming in various ways;

Turbulent bubbles lift and dislodge bio-film. Low dose Iodine reduces microbial content Bubble flurry prevent planktonic bacteria from adhering to plate surface. Bubbles impart low dose iodine into water for downstream disinfection of cooling tower and diffusion screens

I 2 Air Fluid Effectiveness

The patented I 2 Air Fluid Infusor Cartridge produces I 2 infused bubbles that are dosed for accurate elution. Elutes only grams per month into water stream. Adjustable based on need and standards. are unaffected by water temperature, turbidity, mineral content or pH. converts to Eco-Friendly iodide after contact with bacteria. will not effect most materials. will have the same effect on microbes as much higher concentrations. are negatively charged.

The cell wall is exposed continually to new low dose iodine within the air bubbles. Iodine is drawn into the cell and key amino acids in the respiratory chain are broken down. The bacteria is destroyed. The I2 infused air molecule eliminates free floating bacteria and bacteria resident in existing biolms. Iodine converts to Eco-friendly iodide and moves downstream.

Bio-film formation 7 days post APF cleaning without i2 bubble exposure. Note plate condition.

Does it work? Results after 8 month protocol use; 300 GPM geothermal well system; Inlet pressure: 13 psi avg. and outlet pressures 4 psi avg. Total labor: 75 minutes per month with NO exchanger breakdown! What about the diffusion screens? “We have been running one 300 GPM supply well. We have left all 3 diffusion wells open. Each diffusion well has a capacity of 300 GPM. In order to determine if all 3 diffusion wells are working properly, we turned two off at a time so that we tested each diffusion well by itself to ensure that it was taking 300 GPM. All 3 took the 300 GPM of water without increases in incoming or outgoing pressure at the heat exchanger. I took that to mean that all 3 diffusion wells are working properly.”

The benefits; T he APF Cleaning Protocol and I 2 Air Infused mixed media; Increases system efficiency. Effectively removes bio-film and minerals. Eliminates exchanger breakdown. Prevents the reformation of bio-films. Does not use caustic chemicals. Uses very low dose iodine. Does not allow exchanger cleaner into groundwater or well. System down time is under 1 hour per month. Low cost of use. Does not expose staff and environment to bio-films and dangerous chemicals. Environmentally friendly.

Use in; Geothermal well/exchanger systems Cooling tower systems Ground water remediation Aeration septic systems Pre-treatment of wastewater Not recommended in airflow only mode for systems above 400 gpm.

Geo thermal System requirements Compressed air source 30 psi 1/cfm maximum. Diffusion well air vent. Heat exchanger inlet drain valve. Exchanger inlet and outlet gate valves. Water source. Drain.