The visible-UV spectrometer we use permits the quantitative determination of the absorption and transmission of light in the wavelength range 200 nm*
Advertisements

Determination of the Rate Law for Food Coloring Bleaching
SURVEY OF CHEMISTRY LABORATORY I SPECTROPHOTOMETRIC DETERMINATION
Use of the Spectronic 20 Spectrophotometer
Investigation 1 What is the relationship between the concentration of a solution and the amount of transmitted light through the solution?
Hemoglobin concentration
Colorimetry & Spectrophotometry.
Ion Exchange Laboratory. Today’s Schedule Pre-lab discussion Ion Exchange and Spectrophotometer Ion exchange experiment.
Smoking in Lab: Some Chemistry Behind It Nature’s kitchen for some really interesting chemicals.
Experiment 22: Colorimetric determination of an equilibrium constant
Determining An Equilibrium Constant Using Spectrophotometry
ALGALTOXKIT F Test procedure. 1 PREPARATION OF ALGAL CULTURING MEDIUM - VOLUMETRIC FLASK (1 liter) - VIALS WITH NUTRIENT STOCK SOLUTIONS A (2 vials),
بسم الله الرحمن الرحيم UMM AL-QURA UNIVERSITY Faculty of Medicine Dep. Of BIOCHEMISTRY.
Fundamental Techniques and Measurements  Mass Measurements  Volume Measurements  Preparation of a solution of known concentration  UV-Visible Spectrophotometer.
COLORIMETRYCOLORIMETRY Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit Note: A printed description of.
Spectroscopic /Colorimetric Analysis
CHEM 213 Instrumental Analysis
Colorimetry & Spectrophotometry.
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
Identification of the common laboratory glassware, pipettes and Equipment . BCH 312 [PRACTICAL]
Experiment 33: Colorimetric determination of iron
Dilution and Spectroscopy Lab Lab Word Document Lab Word Document.
Colorimetry & Spectrophotometry
Visible Spectrophotometer
(glass pipette, centrifuge, spectrophotometry)
Electromagnetic radiation travels through space in the form of a wave, with the distance between two crests of a wave termed a wavelength. At one end.
Microplate reader spectrophotometer. The Beer-Lambert Law A=abc Now let us look at the Beer-Lambert law and explore it's significance. A is absorbance.
Mastering the micropipette. What is a micropipette? How do you use a micropipette? How can I determine if I’m pipetting correctly?
Exp. 18: Spectrophotometric Analysis: Concentration of a Solution Using Beer’s Law White light violet (400nm) – red (800nm) “visible spectrum” sample (light.
An Introduction to the Spectrophotometer. Meet your Spectrophotometer Meet your spectrophotometer.
Spectrofuorometer lab. 1. Fluorescence spectroscopy or (spectrofluorometry) Is a type of electromagnetic spectroscopy which analyzes fluorescence from.
Serial Dilution Activity Using a pipet Simulated Acid: Red = nitric acid Yellow = sulfuric acid Blue = hydrochloric acid.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
Spectrophotometry Ability of molecules to absorb and transmit light energy is the basis of one of the most widely used procedures for determining the concentration.
AP Free Response Questions 2003
Colorimetric determination of manganese in steel
UNI Plant Physiology Measuring Light Absorbance UNI Plant Physiology Spring 2005.
Experiment 33 Colorimetric Determination of Iron CHE1181.
Absorption Spectroscopy CHEM 251 Week of November 1 st, 2010 Alexis Patanarut.
COLORIMETRY & SPECTROPHOTOMETR
LAB. S2: Spectrophotometric Determination of Indomethacin/Salicylic Acid Mixture.
Absorption Spectrum for Plant Pigments
Lab1 A VISIBLE ABSORPTION SPECTROMETER. -One of the simplest and most widely used methods to determine concentration of a substance in solution -Measures.
Spectrophotometry Measuring Concentrations of Substances in Body Fluids.
Lab S1 Spectrophotometric Determination of Ferrous Ion.
Lab1 A VISIBLE ABSORPTION SPECTROMETER
SPECTROPHOTOMETRY White light contains all wavelengths of light in the visible region of the EM. A substance appears colored because it absorbs light.
Principles and practice of Spectrophotometer
Spectrophotometer - Visible Type Spectro - photometer consists of two instruments : Spectrometer   Photometer  Spectrometer   for producing light.
Fundamental Techniques and Measurements
Solutions & Spectrophotometry
Colorimetric Determination of Iron
Spectrophotometric Determination [Co2+]
SPECTROSCOPY.
SPECTROPHOTOMETRY White light contains all wavelengths of light in the visible region of the EM. A substance appears colored because it absorbs light.
Vernier Spectrophotometer
SIDEBAR: PLANTS ABSORB A LOT OF LIGHT ENERGY…
Absorption Spectroscopy
Bellwork Clear everything from desk except: P / P Vocab. Notebooks
Colorimetric Determination of Keq
Beer’s Law and Concentrations
Experiment 4-4: Determination of Glucose in Blood Serum
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Fundamental Techniques and Measurements
Exp. Iron in Vitamin Tablet
Ensuring Reliability June 2013 Paul Beaumont.
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Directions: Answer the following questions on A. P
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Clinical instrumental analysis
Presentation transcript:

What factors affect the intensity of color

Variables to be studied Wavelength Concentration Color Need to study in this order Color

Wavelength

ROYGBIV Red Orange Yellow 700 nm 450 nm Green Blue Indigo Violet

The bending of light as it passes from one medium to another Refraction of Light The bending of light as it passes from one medium to another

Investigate Wavelength For each of the three colors, pick 10 wavelengths from 400-760 nm and measure %T keeping concentration the same. Recalibrate 100%T at each wavelength Check the filter lever

Spectronic-20 Spectrophotometer

Spectronic-20 Ensure that the sample holder (5) is empty. Set the instrument zero by adjusting the 0%T control (3) to set the needle to exactly 0.0 %T on the transmittance scale (4). Ensure that the sample holder (5) is empty. Set the instrument zero by adjusting the 0%T control (3) to set the needle to exactly 0.0 %T on the transmittance scale (4). Insert the reference cuvette into the sample holder, matching up the index line on the sample holder with the index line or label on the cuvette. Adjust the 100%T control (6) to set the needle to exactly 100%T on the transmittance scale. Insert the reference cuvette into the sample holder, matching up the index line on the sample holder with the index line or label on the cuvette. Adjust the 100%T control (6) to set the needle to exactly 100%T on the transmittance scale. Remove the reference cuvette and check the zero. Adjust the 0.0%T control if necessary. Repeat calibration steps until the zero and 100%T are set and stable. Check the zero and 100%T every 15–30 minutes or anytime you change the wavelength. Fill the sample cuvette one-half full with solution and insert the tube into the sample holder. Read the percentage transmittance directly from the transmittance scale to ±0.1%T. Adjust the monochromator control (1) to the set the desired wavelength on the wavelength dial (2). There may be a filter lever (8) on the lower left of the instrument. Set it to the appropriate wavelength range. Adjust the monochromator control (1) to the set the desired wavelength on the wavelength dial (2). There may be a filter lever (8) on the lower left of the instrument. Set it to the appropriate wavelength range.

Spectronic-20 Review 1. Adjust the monochromator control (1) to the set the desired wavelength on the wavelength dial (2). There may be a filter lever (8) on the lower left of the instrument. Set it to the appropriate wavelength range.   2. Ensure that the sample holder (5) is empty. Set the instrument zero by adjusting the 0%T control (3) to set the needle to exactly 0.0 %T on the transmittance scale (4). 3. Insert the reference cuvette into the sample holder, matching up the index line on the sample holder with the index line or label on the cuvette. Adjust the 100%T control (6) to set the needle to exactly 100%T on the transmittance scale. 4. Remove the reference cuvette and check the zero. Adjust the 0.0%T control if necessary. Repeat steps 2–4 until the zero and 100%T are set and stable. 5. Fill the sample cuvette one-half full with solution and insert the tube into the sample holder. Read the percentage transmittance directly from the transmittance scale to ±0.1%T. 6. Check the zero and 100%T every 15–30 minutes or anytime you change the wavelength.

Investigate Concentration Prepare 4-5 solutions of known concentration for each dye solution (given burettes, 25 mL volumetric flasks and a stock solution of known concentration) How will you pick which wavelength you should use?

A note on Spectrophotometric theory Transmittance T:

Dilution Calculations Given: [blue food dye] = 1.334  10-5 M   Using normal laboratory glassware, how will you prepare 5 solutions with concentrations between 5.3  10-7 M and 1.3  10-5 M