Fusional vergence
Maddox components of vergence Tonic Fusional Accommodative Proximal
Maddox’s thoughts 4 components are independent Additive a given vergence movement can be decomposed into components which are added together to produce the full movement If any one component is insufficient, pts. will have nearpoint complaints asthenopia
Specifying the amount of vergence Three basic units of measurement Angular (°) Prism diopters (∆) Meter angles
Angular Take distance from target and pd in identical units of measurement Divide pd in half Take inverse tangent of 0.5 pd/distance Double that to get the full angle d (m) R R’ pd (cm)
Prism diopters most commonly used clinical measure of vergence angle 1∆ (prism diopter) is the tangential deviation of 1 linear centimeter at 1 meter’s distance For ø ≤ 10 deg., tan ø=ø and ∆ = p/d a viewing distance of .4 m( 40 cm) with p = 6 cm (60 mm), the eyes must converge 15∆ (6/.4).
Meter angle The meter angle is the amount of vergence required for both eyes to look at an object at 1m distance 1 meter angle = 1/d (in m) 1 meter angle = 1∆/p.d.
Proximal Vergence Maddox called this component “psychic” vergence the amount of vergence produced by the awareness of a near object In the optometric exam, the phoroptor is a near object that can contribute to a vergence posture.
Tonic Vergence difference between the anatomical position of rest and the physiological position of rest anatomical position of rest is that which the eyes assume in deep anesthesia, coma, or death divergent
Physiological position of rest orientation of the two eyes in the absence of any stimulus to fusion identical to the distance phoria if the eyes are emmetropic or properly refracted
Distance phoria A patient is said to be orthophoric if he/she has no distance phoria. If there is a heterophoria, its direction shows whether tonic vergence is excessive or insufficient If exophoric (eyes divergent), tonic vergence is probably insufficient. If esophoric (eyes convergent), tonic vergence is probably excessive.
Distance phoria phoria = position of the two eyes is the position of the visual axes relative to one another when all stimuli to binocular fusion have been eliminated. “dissociating” the two eyes assumes that the person is emmetropic or properly corrected
Qualifers If there are visual stimuli for fusion, the position of the eyes will be determined by both fusional vergence and tonic vergence. If the test target is nearer than about 6 m, accommodative vergence will also be present.
Dissociating the two eyes two ways by covering one eye, as in the cover test by placing a dissociating prism in front of one eye and a measuring prism in front of the other use a value of vertical dissociating prism that is too great to be overcome by fusional vergence in front of one eye (e.g., 7-8∆).
Exophoria target perception Through dissociating prism Measuring prism
Distance phoria If alignment occurs at 0 ∆, the patient is orthophoric. If alignment requires base-in prism, the patient is exophoric. If alignment requires base-out prism, the patient is esophoric.
Distance phoria Distance phoria measurements assume the target is located at 6 m or greater. Tonic vergence is a significant determiner of the distance phoria. Other factors contributing to distance phorias the position of the eye in the orbit the length of the EOM the positions of the insertions of the EOM.
Fusional vergence also known as disparity vergence operates to reduce retinal disparity To see an object singly, the image of the fixated object must falls on corresponding points on the two retinas
Corresponding retinal points Definition: points on the two retinas which, when stimulated, give rise to perception of identical visual direction Fusional vergence movements take place to eliminate noncorresponding retinal stimulation or retinal disparity fusional vergence prevents diplopia
Eliciting fusional vergence place a prism in front of one eye The eye will move (fusional vergence movement) to prevent diplopia. uncover a covered eye elicits a fusional vergence movement The eye will move from the phoria position to obtain single binocular vision.
Clinical determination of fusional vergence Ideally, introduce a small amount of horizontal prism, in equal amounts, before the two eyes Inward movements are positive and outward movements are negative base-out prism induces positive fusional vergence (convergence) base-in prism induces negative fusional vergence (divergence)
Clinical tests at both distance and near (40 cm.) using 20/20 letters as the test target patient is asked to report if the letters blur or become double note prism powers where blur (if it occurs) and where doubling (break) are reported then reduce prism until the target is seen singly (recovery)--and note that value
Negative fusional vergence at distance At optical infinity: base-in prism is added equally before the two eyes as the patient views 20/20 letters What does the blur indicate? Is a blur finding expected in this case? Why or why not? What does the break represent? What does recovery mean?
Negative fusional vergence at distance Blur indicates the limits of negative fusional vergence now accommodative vergence is called on the supplement fusional vergence in this case, we have to diverge so we would have to relax accommodation Should we be able to relax accommodation at 6 m?
Negative fusional vergence at distance Break indicates that the total ability of the eyes to diverge to avoid diplopia has been reached. The eyes return to the phoria position at break. Recovery indicates that a negative fusional vergence movement has been made to again obtain single binocular vision.
Positive fusional vergence at distance adds base-out prism equally before the two eyes while the patient focuses on the test target (20/20 letters) patient again reports blur, break and recovery. Should we have a blur finding here?
Positive fusional vergence Blur -- limits of fusional vergence accommodative vergence is being called on to supplement fusional; we should be able to accommodate at distance Break -- limits of accommodative vergence (if there is blur Recovery occurs after the eyes have converged (positive fusional vergence movement).
Negative and positive fusional vergence at near same tests but performed at 40 cm expects blur for base-in vergence focusing on a target at 40 cm demands 2.5D of accommodation (D=1/.4m) accommodation is relaxed to supplement negative fusional vergence
Expected values for fusional vergence from Morgan (and Bachman) At optical infinity Base-in x/7/4 Base-out 9/19/10 At 40 cm Base-in 13/21/13 Base-out 17/21/11