Electrochemical Sensors

Slides:



Advertisements
Similar presentations
CHEMISTRY in Biology.
Advertisements

OFFLINE COMPOSITION MEASURING SENSORS
Unit 12 Conduction in Liquids and Gases
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
Electrochemistry.
Modeling in Electrochemical Engineering
Mrs Khadijah Hanim bt Abdul Rahman Sem II 2011/2012 Week 15: 28 & 31 May 2012.
Unit 11- Redox and Electrochemistry
Lecture 21 QCM and Ellipsometry
Introduction to Electroanalytical Chemistry
Introduction to electrochemistry - Basics of all techniques -
Chapter 17 Electrochemistry
ELECTROCHEMISTRY. During electrolysis positive ions (cations) move to negatively charged electrode (catode) and negative ions (anions) to positively charged.
Chemical vs. Electrochemical Reactions  Chemical reactions are those in which elements are added or removed from a chemical species.  Electrochemical.
Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?
Nanobiosensors Sara Huefner November 6, Outline Biosensor Background –What is a Biosensor? –Components of a Biosensor –Principles of Detection Biosensors.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Lecture 9. Chemical Sensors In general, the aim of a chemical sensor is to measure the concentration of a specific substance Substances to be sensed fall.
Dr. Marc Madou Class II. Electrochemistry Background (I) Winter 2009 BIOMEMS.
Prentice Hall © 2003Chapter 20 Zn added to HCl yields the spontaneous reaction Zn(s) + 2H + (aq)  Zn 2+ (aq) + H 2 (g). The oxidation number of Zn has.
Chapter 19 Electrochemistry
Voltaic Cells Chapter 20.
Lesson 2. Galvanic Cells In the reaction between Zn and CuSO 4, the zinc is oxidized by copper (II) ions. Zn 0 (s) + Cu 2+ (aq) + SO 4 2-  Cu 0 (s) +
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
PH0101 UNIT-5 LECTURE 7 Introduction Types of battery Lithium battery
EKT314/4 Electronic Instrumentation
Foundations of Chemistry
Zn  Zn2+ + 2e- (oxidation) Cu e-  Cu (reduction)
PH 0101 Unit-5 Lecture-91 Introduction Principle, construction and working of Ultracapacitor Advantage, disadvantage and application PH0101 UNIT-5 LECTURE.
Chapter 17 Electrochemistry 1. Voltaic Cells In spontaneous reduction-oxidation reactions, electrons are transferred and energy is released. The energy.
Chemistry in Biology.
Summer Course on Exergy and Its Applications EXERGY ANALYSIS of FUEL CELLS C. Ozgur Colpan July 2-4, 2012 Osmaniye Korkut Ata Üniversitesi.
CHEMISTRY. Composition of Matter Matter - _____________ _______________________ Matter is anything that ________________ ________________ ______ – quantity.
TA202A Lecture-10 Instructor: Shantanu Bhattacharya.
Electrochemistry Chapter 20 Electrochemistry. Electrochemistry Electrochemical Reactions In electrochemical reactions, electrons are transferred from.
1 Chapter Eighteen Electrochemistry. 2 Electrochemical reactions are oxidation-reduction reactions. The two parts of the reaction are physically separated.
Chapter 20 Electrochemistry and Oxidation-Reduction.
Redox Reactions Year 11 Chemistry ~ Unit 2.
Biomedical Electrodes, Sensors, and Transducers
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
6/2/20161 CHAPTER 2 CORROSION PRINCIPLES Chapter Outlines 2.1 Oxidation and Reduction Reactions 2.2 Standard Electrode Half- Cell Potentials 2.3 Standard.
Oxidation and Reduction Lecture 9. Law of Mass Action Important to remember our equation describes the equilibrium condition. At non-equilibrium conditions.
Chapter 20 Electrochemistry Lecture Presentation © 2012 Pearson Education, Inc.
Polarization.
Chapter 26 – Electricity from Chemical Reactions.
CHAPTER 11 ELEMENTS OF ELECTROCHEMISTRY Introduction to Analytical Chemistry.
Chapter 17 Corrosion and Degradation of Materials.
Voltaic/Galvanic Cells. Voltaic Cells In spontaneous oxidation-reduction (redox) reactions, electrons are transferred and energy is released.
Chapter 20 Electrochemistry. Electrochemical Reactions In electrochemical reactions, electrons are transferred from one species to another.
Electrochemistry.
Chapter 20 Electrochemistry. © 2009, Prentice-Hall, Inc. Oxidation Numbers In order to keep track of what loses electrons and what gains them, we assign.
Electrochemistry © 2009, Prentice-Hall, Inc. Electrochemical Reactions In electrochemical reactions, electrons are transferred from one species to another.
Electric Currents Charges in motion.. Creating Potential Difference. Alessandro Volta ( ) –Ranked potentials created by combing two metal discs.
Electrochemistry (2 lectures) Mr. Zaheer E. Clarke 1:00 p. m. / 2:15 p
Electrochemistry. What is “electrochemistry”? The area of chemistry concerned with the interconversion of chemical and electrical energy. Energy released.
ELECTROCHEMICAL CELLS. ELECTROCHEMISTRY The reason Redox reactions are so important is because they involve an exchange of electrons If we can find a.
Electrochemistry The Study of the Interchange of Chemical and Electrical Energy.
CHEMISTRY. Composition of Matter Matter - Everything in universe is composed of matter Matter: anything that occupies space or has mass Mass – quantity.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Chapter 1: The Nature of Analytical Chemistry
CHEMISTRY REVIEW. Composition of Matter Matter - Everything in universe is composed of matter Matter is anything that occupies space or has mass Mass.
ELECTROCHEMISTRY CHEM171 – Lecture Series Four : 2012/01  Redox reactions  Electrochemical cells  Cell potential  Nernst equation  Relationship between.
ELECTRO-ANALYTICAL TECHNIQUES   POTENTIOMETRIC TECHNIQUES Principle Electrochemical techniques/ Electrochemical methods are generally used for determination.
Hemodialysis Lecture 3.
Rapid Lab Systems measuring principle
Advanced Higher Chemistry Unit 2(e)
Instrumental Methods II
(Bio)Chemical Sensors
Presentation transcript:

Electrochemical Sensors Electrochemical sensors are the most versatile and highly developed chemical sensors. They are divided into several types: Potentiometric (measure voltage) Amperometric (measure current) Conductometric (measure conductivity) Sometimes the distinction between these types can be blurred. In all these sensors, special electrodes are used.

Electrochemical Sensors Either a chemical reaction takes place or the charge transport is modulated by the reaction Electrochemical sensing always requires a closed circuit. Current must flow to make a measurement. Since we need a closed loop we need at least two electrodes. These sensors are often called an electrochemical cell. How the cell is used depends heavily on the sensitivity, selectivity and accuracy.

Potentiometric Sensors Potentiometric sensors use the effect of the concentration on the equilibrium of redox reactions occurring at the electrode-electrolyte interface of an electrochemical cell The redox reaction takes on the electrode surface: Oxidant + Ze- => Reduced product Z is the number of electrons involved in the redox reaction www.chemie.uni-greifswald.de/

Electrochemical Cell The reaction takes place at the cathode where electrons are “pulled” out of the electrode.

The Nernst equation gives the potential of each half cell. Co is the oxidant concentration CR is the Reduced Product Concentration n is the number of electrons transferred per redox reaction F is the Faraday constant T is the temperature R is the gas Constant E0 is the electrode potential at a standard state. The Nernst equation gives the potential of each half cell. In a potentiometric sensor, two half-cell reactions take place at each electrode. Only one of the reactions should involve sensing the species of interest. The other should be a well understood reversible and non-interfering reaction

CHEMFET Sensors Very popular where small size and low power consumption is essential. (Biological and Medical monitoring). CHEMFETs are chemical potentiometric sensors based on the Field-Effect transistors CHEMFETs are solid state sensors suitable for batch fabrication. The surface field effect can provide high selectivity and sensitivity. These are extended gate field-effect transistors with the electrochemical potential inserted over the gate surface.

Four types of CHEMFETs: Ion Selective gas selective, enzyme-selective immuno-selective sensors. Ion selective are the most widely used, known as ISFETs A lot of the art of CHEMFETs is in engineering the porous layer over the gate.

The sensor is given a pH sensitivity by exposing the bare silicon nitride gate insulator to the sample solution. Ion selective CHEMFET with a silicon nitride gate for measuring pH (H+ ion concentration.)

Ionic selectivity is determined by the surface complexation of the gate insulator. Selectivity of the sensor can be obtained by varying the composition of the gate insulator. As the ionic concentration varies, the surface charge density at the CHEMFET gate changes as well.

Also add ion-selective membranes can be deposited on the top of of the gate to provide a large selection of different chemical sensors. A change in the surface charge density affects the CHEMFET channel conductance, which can be measured as a variation in the drain current. Thus a bias applied to to the drain and source of the FET results in a current I, controlled by the electrochemical potential. This in turn is proportional to the concentration of the interesting ions in solution.

A biosensor sensitive to a particular protein or virus can be made by coating the electrode with the appropriate antibody. Extreme care must be taken to electrically isolate the signals from the solution!

Carbon nanotubes Sheets of carbon atoms can be ‘rolled’ up into tubes of nanometer dimensions Layers of nanotubes have a huge surface to volume ratio

Nanotube (blue) lying across electrodes Carbon nanotubes Carbon nanotubes can be grown en masse, or separated as individuals. Nanotube (blue) lying across electrodes Nanotube forest

Carbon Nanotube sensors The Scanning Electron Micrograph shows a bridge made from a single nanotube. It is linking two ‘cliffs’ made of Au and Ti. N2 gas is blown up from the bottom The resistance of the sensor increases upon exposure to N2 gas www.bios.el.utwente.nl/internal/Transducers03/Volume_1/2E80.P.pdf

CNT FET sensor Can also make FET sensors out of carbon nanotubes A small current in the nanotube causes a much larger current in the FET This particular sensor responds to light. www.echo.nuee.nagoya-u.ac.jp/~yohno/research/cnt/qnn03_abstract_submitted.htm

Titanium nanotube sensors H2 gas is ionised when it hits the walls of the titanium nanotubes The resulting electron current is a measure of the amount of hydrogen present. www.eurekalert.org/pub_releases/2003-07/ps-tnm072903.php

Lecture 10 Empty?

Lecture 11

Concentration Sensors Concentration sensors react to the concentration of a specific chemical. The concentration modulates some physical property (eg resistance or capacitance). Generally speaking, no chemical reaction takes place in the sensor. Often called physical sensors.

Resistive Sensors To detect the presence of a liquid phase chemical, a sensor must be specific to that particular agent a certain concentration. Eg. Resistive detector of hydrocarbon fuel leaks. (Bell Corporation). Made of silicone and carbon black composite Polymer matrix is the sensing element. Constructed as a very thin layer with large surface area.

Sensor is not susceptible to polar solvents like water. However hydrocarbons are absorbed by the polymer matrix The matrix swells and the resistivityy increases from 10 /cm to 109 /cm Response time is less than a second.

Sensor returns to normal conductive state when hydrocarbon is removed. The device is reusable and can be placed underground. Ideal for oil exploration.

The resonant frequency is a function of the crystal mass and shape. Gravimetric Sensors Measurement of microscopic amount of mass cannot be accomplished using conventional balances. Use oscillating sensor (sometimes called acoustic gravimetric sensor) which measures thin layers. The oscillating sensor measures the shift in the resonant frequency of a piezoelectric quartz oscillator. The resonant frequency is a function of the crystal mass and shape.

The device can be described as an oscillating plate whose natural frequency depends on its mass. Adding material to that mass would shift the frequency which can be accurately measured electronically.

The oscillating detector converts mass value to a frequency shift. F0 = the unloaded natural frequency, f is the frequency shift, m is the added mass per unit area and Sm is the sensitivity factor. The numerical value of Sm depends upon the design, material and operating frequency of the sensor. The oscillating detector converts mass value to a frequency shift. It is extremely easy to dtermine frequency, so the sensor’s accuracy is determined by how well Sm is known.

Fluid density sensors. Several basic methods are used for determination of fluid density Measurement of inertial mass. Measurement of Gravitational Mass. Buoyant force. Hydrostatic pressure. Attenuation of -rays

Density measurement The fluid is forced to flow through the sensor which has a hollow tube. The sensor is made of silicon and the tube forms a double-loop within the device.

The tube inlet and outlet are at the side and the entire loop is designed for torsional vibration. The mass of the actual tube is kept small so the total mass of the vibrating object is mostly that of the fluid. The resonant frequency of the vibration is proportional to the total mass of the tube and fluid. Since the volume in the tube is constant, the frequency is proportional to the density of the fluid. Once again we exploit the physical properties of the material to directly measure characteristics of the material (the fluid).