CH250 Intermediate Analysis – Part 3

Slides:



Advertisements
Similar presentations
24.6 Diffraction Huygen’s principle requires that the waves spread out after they pass through slits This spreading out of light from its initial line.
Advertisements

Bohrs successes and failures: The wave nature of the electron.
Basic Electron Microscopy
Objectives By the end of this section you should:
Thin Films, Diffraction, and Double slit interference
Electromagnetic Waves G5 - X Rays. Coolidge tube (X-ray tube) K = Hot filament cathode A = Tungsten anode U h = Heater Voltage (e.g. 12V) U a = Accelerating.
Instrumental Chemistry
Copyright © 2009 Pearson Education, Inc. Chapter 35 Diffraction and Polarization.
BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
Introduction to Electron Microscopy
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Interference and Diffraction
The Wave Nature of Light
PHYS 1442 – Section 004 Lecture #21 Wednesday April 9, 2014 Dr. Andrew Brandt Ch 24 Wave Nature of Light Diffraction by a Single Slit or Disk Diffraction.
Scanning Electron Microscope (SEM)
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
Diffraction of Light Waves
Scanning Probe Microscopy
SCANNING PROBE MICROSCOPY By AJHARANI HANSDAH SR NO
Lecture 10. AFM.
Lecture 8: Measurement of Nanoscale forces II. What did we cover in the last lecture? The spring constant of an AFM cantilever is determined by its material.
MSN 510 Imaging Techniques in Materials Science and Nanotechnology
Phy 212: General Physics II Chapter 35: Interference Lecture Notes.
Microscopy as a Means for Nano-Characterization
Introduction to scanning electron microscopy
Spectroscopic Techniques for Probing Solid Surfaces Part II of Surface Primer.
Get to the point!. AFM - atomic force microscopy A 'new' view of structure (1986) AlGaN/GaN quantum well waveguide CD stamper polymer growth surface atoms.
3: Interference, Diffraction and Polarization
Interference Diffraction and Lasers
Microscope.
Chapter 7 X-Ray diffraction. Contents Basic concepts and definitions Basic concepts and definitions Waves and X-rays Waves and X-rays Crystal structure.
TAPPINGMODE™ IMAGING APPLICATIONS AND TECHNOLOGY
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Scanning Electron Microscope (SEM)
Chapter 24 Wave Optics. General Physics Review – waves T=1/f period, frequency T=1/f period, frequency v = f velocity, wavelength v = f velocity, wavelength.
Chapter 13 The Characteristics of light. Objectives Identify the components of the electromagnetic spectrum. Calculate the frequency or wavelength of.
X-Ray Diffraction Dr. T. Ramlochan March 2010.
Other modes associated with SEM: EBIC
Tutorial 4 Derek Wright Wednesday, February 9 th, 2005.
TEM charcaterization Basic modes – Bright field microscopy – Dark field Microscopy –STEM – EDAX – EELS.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Interference in Thin Films, final
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Scanning Probe Microscopy Colin Folta Matt Hense ME381R 11/30/04.
Crystallography and Diffraction. Theory and Modern Methods of Analysis Lectures Electron Diffraction Dr. I. Abrahams Queen Mary University of London.
Fundamental Physics II PETROVIETNAM UNIVERSITY FACULTY OF FUNDAMENTAL SCIENCES Vungtau, 2013 Pham Hong Quang
Atomic Force Microscopy (AFM)
Physics 203/204 6: Diffraction and Polarization Single Slit Diffraction Diffraction Grating Diffraction by Crystals Polarization of Light Waves.
Characterization of Nanomaterials…
The law of reflection: The law of refraction: Image formation
1.1 What’s electromagnetic radiation
Characterization of Nanomaterials 1- Scanning Electron Microscopy (SEM) It is one of the most widely used techniques in the characterization of the morphology,
Scanning Transmission Electron Microscope
Microscopy.
Scanning Probe Microscopy
METHODOLOGY Nanotechnology Prof. Dr. Abdul Majid Department of Physics
Get to the point!.
Get to the point!.
Introduction to scanning electron microscopy
Introduction to scanning electron microscopy
Low-Loss and No-Loss Spectra
Laboratory equipment Lecture (3).
NANO 230 Micro/NanoFabrication
TEM (Transition Electron Microscope)
Chem E5225 – Electron Microscopy P
General Physics (PHY 2140) Lecture 28 Modern Physics Quantum Physics
Light Through a Single Slit
Atomic Force Microscope
Presentation transcript:

CH250 Intermediate Analysis – Part 3 Materials & Nanotechnology Dr Raymond Whitby C407

Overview Defining nano Formation of nanocarbon Viewing the nanoscale; direct analysis Indirect analysis of the nanoscale Adsorption experiment

Various interactions of electrons with a sold target 3. Viewing the nanoscale Various interactions of electrons with a sold target © P.J. Grundy, Electron Microscopy in the Study of Materials, 1976

Viewing the nanoscale DATE NAME EVENT 1897 J. J. Thompson Discovers the electron 1924 Louis deBroglie Identifies a wavelength to moving electrons λ=h/mv where λ = wavelength h = Planck's constant (6.626 x 10-34 J s) m = mass v = velocity (For an electron at 60kV λ = 0.005 nm) 1926 H. Busch Magnetic or electric fields act as lenses for electrons 1929 E. Ruska Ph.D thesis on magnetic lenses 1931 Knoll & Ruska First electron microscope built Davisson & Calbrick Properties of electrostatic lenses 1934 Driest & Muller Surpass resolution of the LM 1938 von Borries & Ruska First practical EM (Siemens) - 10 nm resolution 1940 RCA Commercial EM with 2.4 nm resolution 1945   1.0 nm resolution p = momentum

Abberation (1.1) Spherical aberration constant usually Cs 1-2mm Spherical aberration occurs when electrons travelling further from the optic axis, which are more likely to be deviated, are focussed at different points along the optic axis. Each point in the object is therefore imaged a disc of radius, Δrs

Abberation Chromatic aberration arises because of a spread in energy acting on the electrons, leading to a small divergence of the electron beam, Δrc Astigmatism occurs when electrons go through different focal lengths, depending on the plane of the ray paths, ΔrA

Resolution The Rayleigh criterion specifies the minimum separation between two light sources that may be resolved into distinct objects Point to point resolution limit: Δrd = 0.61λ / β (1.2) Increasing aperture size increases resolution according to (1.2) but decreases according to (1.1), an optimum aperture size minimising their sum: Interference between scattered wave and undeviated wave causes amplitude variation (1.3) Giving a maximum resolution: (1.4) © J. W. Edington, Practical Electron Microscopy in Materials Science, Macmillan Press, 1974

Electron waves de Broglie λ = h / m.v An electron’s momentum is usually defined by falling through a potential difference: eV = ½ m.v2 e is the electronic charge in volts (1 electron volt = 1.602 x 10-19 J), therefore: λ = h / (2.m.eV)½ When V is large electrons approach speed of light, therefore electron mass must be accounted for through the relativistic accelerating voltage Vr, but usually when V ≥ 105 volts: Vr = V.[1 + eV / 2.m0.c2] So, when accelerating voltage is 100 kV, the wavelength is 0.0037nm and the optimum resolving power is 0.23nm, less than lattice spacing of graphite!

Viewing the nanoscale Resolution limits: Light Microscope = 500nm (air/water) Scanning Electron Microscope = 2nm Transmission Electron Microscope = 0.1 nm (both vacuum/dry) © J. W. Edington, Practical Electron Microscopy in Materials Science, Macmillan Press, 1974

EM imaging Contrast effects are generated by small phase variations among the electrons passing through the sample. By combining all or most of the beams transmitted and scattered by the sample in the formation of the image, a phase contrast image is produced. A model of a nanotube interacting with an electron beam is shown above. Part of the electron beam scatters at the top and bottom parts of the tube (point H). The contrast of this scatter is relatively weak, due to a low number of atoms in this (hk0) plane aligned to the electron beam, but structural detail here is often observed on precisely tuned TEMs. Part of the electron beam also scatters at the sides of the tube (point V). The contrast is relatively stronger as there are a greater number of atoms in the (00l) plane aligned to the electron beam. This gives rise to the appearance of the nanotube “walls”.

EM imaging When the electron beam passes through a sample, a diffraction pattern is formed at the back focal plane of the objective lens, which contains all of the information present in the specimen. The diffracted beams forming this pattern can be recombined with the transmitted electrons in the image plane to form a lattice image. By collecting the transmitted electrons only, achieved by placing an aperture to obstruct the diffracted electrons, a bright field image is obtained. Conversely, by only collecting the diffracted beams and obstructing the transmitted beams, a dark field image can be obtained.

TEM gallery © M. Monthioux, et al., Carbon, 39, 1261 (2001) & Carbon (2003)

Carbon nanotube growth © M. Terrones, et al., Top. Curr. Chem., 199, 189-234 (1999)

Electron diffraction (TEM cont.) The crystal lattice of a sample causes diffraction of the electron beam. When the crystal planes are aligned with an hkl plane at an angle θ to the beam axis, commonly scattered beams interfere constructively. Since the Bragg angle for high-velocity electron beams is very small, sin θ approximates to θ, and for n = 1 the Bragg equation (2dhkl sin θ = nλ) is simplified: Bragg Equation Standard x-ray diffraction In the electron microscope, the film is placed at a distance L (the camera length) from the sample. The distance r from the centre spot O to the diffracted spot H is expressed:

Electron diffraction (TEM cont.) By combining these equations, it is possible to determine an unknown spacing dhkl, when r is measured from the diffraction pattern and Lλ is known. The relationship between the distance of the diffracted spot, from the centre spot, r and the interplanar spacing dhkl of the sample from which it originated is: Single-walled carbon nanotube with a rolling vector of 12.5 ±0.5o © M. Monthioux, et al., Carbon, 39, 1261 (2001) & Carbon (2003)

Energy Dispersive X-ray (TEM cont.) When the electron beam strikes the sample, an incident electron may collide with an electron in the K shell and ejects it, resulting in ionisation of the atom. Another electron, from say a higher shell, can fall into this vacancy and emits its excess energy as an X-ray photon. Such a transition from the L to K shell results in a Kα line and from the M to K shell gives a Kβ line, etc. These X-rays are detected by energy dispersive techniques.

Electron Energy Loss Spectroscopy (TEM cont.) EELS is concerned with the study of the electron excitation processes, each of which results in a fast electron losing a characteristic amount of energy. After interacting with the sample, the transmitted electrons are directed into a high-resolution electron spectrometer which separates the electrons according to their kinetic energy and produces an EELS spectrum showing the scattered intensity as a function of the decrease in kinetic energy of the fast electron: Inelastic scattering from outer-shell electrons is visible as a peak in the 5-50 eV region of the spectrum. Inner-shell excitations appear in the form of edges, which represent the ionisation threshold. Since inner-shell binding energies depend on the atomic number of the scattering atom, the ionisation edges present in an EELS spectra indicate which elements occur within the sample. By monitoring particular energy losses within a selected range, it is possible to produce energy-filtered images that reveal the elemental mappings of desired elements.

Electron Energy Loss Spectroscopy (TEM cont.) The K-shell electrons in the carbon atoms, of MWCNTs, interact with the high-energy electrons to be excited into the vacant π* and σ* levels. Through this process, the transmitted electrons lose characteristic energy of ca. 285 keV, similar to that of graphite: © K. Yase, et al., Thin Solid Films, 273, 222 (1996).

EELS & TEM

Scanning Electron Microscopy SEM involves the production of back-scattering and emission of electrons from the near surface of a sample. Larger samples provide longer path lengths increasing the probability of inelastic collisions as well as scattering. Incident electrons are dispersed into a ‘pear’ shaped volume; if secondary electrons that are created possess sufficient energy to escape to the surface, then they will be sampled. Overall, the interaction volume will be much larger than the sampled volume, therefore, SEM is better suited for larger scale materials. © P.J. Grundy, Electron Microscopy in the Study of Materials, 1976

Scanning Electron Microscopy Patterned carbon nanotube (CNT) arrays on Si substrate fabricated using a two layer Sn/Ni catalyst in a diffusion ethanol flame. © N. Liu et al. Diamond & Related Materials 18 (2009) 1375–1380

Carbon nanotube suspension SEM of buckycolumns Frit Membrane disk Carbon nanotube suspension Force

SEM of buckycolumns R.L.D. Whitby, T. Fukuda, T. Maekawa, accepted Nanotechnology, 2010

Petrochemical & biochemical screening Self-contained variable filtration Petrochemical & biochemical screening

Iron atoms on copper surface Topographical Microscopy Scanning Tunnelling Microscopy (STM) is a process of mapping a surface with an ultrafine point in a sample contact situation, giving a resolution down to individual atoms. The tip has a bias voltage applied and passed over a conducting surface. The tunnelling current is subsequently measured yielding sample topology. Atomic Force Microscopy (AFM) is a process of passing a tip over a surface in a non-contact situation, allowing measurement of the tip-surface forces. In addition to topology, the friction and adhesion properties can also be measured. 3nm 200nm Iron atoms on copper surface Silica spheres © Google images & IBM

STM The ultrafine tip is manipulated through a piezoelectric tube. The low tunnelling currents (ca. 10-10A) are amplified and measured as a function of piezoelectric position of the tip. The tunnelling current measured is a function of the gap (W) between the tip and substrate: I(W) = Ce(-W√f) C is a constant, f is the sample’s work function. Work function is equal to the energy barrier of electron transfer and can be controlled by changing the potential on the tip or substrate. © www.bath.ac.uk, CH20016 Lecture 10 notes

STM Two operation modes: Maintain a constant tip to surface height, but a variable tunnelling current Maintain a constant current, but varying the tip to surface height STM image of a chiral, single walled carbon nanotube STM requires ultrahigh vacuums and conductive samples only! © Jeroen Wildoër, Delft University of Technology

AFM A sharp tip on a cantilever is drawn across the surface of a sample. The changes in forces between the tip and the sample are measured as a function of the position of the tip to the surface. The tip position is measured by imagining the reflection of a laser from the rear side of the cantilever. A 4 quadrant photodiode is used to record movement in the x, y, z planes. Similar to STM, the tip forces or tip height can be kept constant depending on the mode of operation. © xintek.com & Google images

AFM The forces that are exerted on the tip will vary according to: • the substrate under examination, • the environment around the tip (e.g. water, air or vacuum) • the chemical functionality of the surface (e.g. hydrophilic / hydrophobic) • softness / hardness of the sample’s surface • Tip raster velocity “In contact mode, the force between the tip and the surface is kept constant during scanning by maintaining a constant deflection. However, close to the surface of the sample, attractive forces can be strong, causing the tip to 'snap-in' to the surface. Thus static mode AFM is almost always done in contact where the overall force is repulsive. Tapping mode occurs when the tip is oscillated near its resonance frequency by a small piezoelectric element mounted in the AFM tip holder. Due to the interaction of forces acting on the cantilever when the tip comes close to the surface, Van der Waals force or dipole-dipole interaction, electrostatic forces, etc cause the amplitude of this oscillation to decrease as the tip gets closer to the sample. A tapping AFM image is therefore produced by imaging the force of the oscillating contacts of the tip with the sample surface.” © Wikipedia 2010

J-P. Salvetat, et al., Phys. Rev. Lett., 82, 944 (1999) Carbon nanotube strength + AFM “The superposition principle implies that the total deflection, σ, is the sum of the deflections due to bending, σB, and to shear, σS. If we use the unit-load method for a concentrated load F, the deflection at the middle becomes σ = σB + σS = F L3/192.E.I + fs.F.L /4.G.A where L is the suspended length, E is the elastic modulus, fs is the shape factor (equal to 10/9 for a cylindrical beam), G is the shear modulus, I is the second moment of area of the beam (I = πD4/64 for a filled cylinder), and A is the cross-sectional area. The ratio σB / σS increases with the ratio of beam length to diameter.” J-P. Salvetat, et al., Phys. Rev. Lett., 82, 944 (1999) Individual arc-MWCNT, Young’s modulus = 270 to 950 Gpa Individual cvd-MWCNT = 15- 50 Gpa

AFM revolution “The molecule is very fragile, but the researchers were able to capture the details of the hexagonal carbon rings and deduce the positions of the surrounding hydrogen atoms. One key breakthrough was finding a way to stop the microscope's tip from sticking to the fragile pentacene molecule because of attraction due to electrostatic and van der Waals forces... The team achieved this by fixing a single carbon monoxide molecule to the end of the probe so that only one atom of relatively inactive oxygen came into contact with the pentacene.” © http://i.livescience.com/images/090827-pentacene-image-02.jpg © http://www.newscientist.com/article/dn17699-microscopes-zoom-in-on-molecules-at-last.html

Questions on microscopy Why does electron microscopy have a better resolution than light microscopy? Briefly describe the three aberrations that exist within electron microscopy. What is the difference between bright field and dark field imaging? What are the differences between transmission electron microscopy and scanning electron microscopy? What are the differences between atomic force microscopy and scanning tunnelling microscopy?