16th July 2013NCSLI 2013, Nashville1. The Design of a Calculable AC voltage reference using digital waveform generation 16th July 2013NCSLI 2013, Nashville2.

Slides:



Advertisements
Similar presentations
Principles & Applications Small-Signal Amplifiers
Advertisements

Introduction to Alternating Current and Voltage
Control and Feedback Introduction Open-loop and Closed-loop Systems
A Stabilization Technique for Phase-Locked Frequency Synthesizers Tai-Cheng Lee and Behzad Razavi IEEE Journal of Solid-State Circuits, Vol. 38, June 2003.
DAM-Île de France Département Analyse, Surveillance, Environnement 06/06/2014 DIF/DASE/B.ALCOVERRO 1 INFRASOUND SENSOR CALIBRATION DEVICE 13/11/2001 Infrasound.
Calibration of high-frequency wattmeters used for standby power testing to IEC August 2011 I. Budovsky and D. Georgakopoulos National Measurement.
Digital Current Transformer Reporter
Interfacing to the Analog World
Operational Amplifiers
Operational Amplifiers 1. Copyright  2004 by Oxford University Press, Inc. Microelectronic Circuits - Fifth Edition Sedra/Smith2 Figure 2.1 Circuit symbol.
Lecture 4: Signal Conditioning
BIOPOTENTIAL AMPLIFIERS
Chapter 4 DC to AC Conversion (INVERTER)
Analog-to-Digital Converter (ADC) And
Sensors Interfacing.
Measurement of Voltages and Currents
CORRECTING RMS VALUE OF A SINE WAVEFORM SAMPLED DUE LIMITED NUMBER OF PERIODS AND DETERMINATE APERTURE TIME ON DMM Keywords: Digital Multimeter (DMM),
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
University Of Vaasa Telecommunications Engineering Automation Seminar Signal Generator By Tibebu Sime 13 th December 2011.
5/4/2006BAE Analog to Digital (A/D) Conversion An overview of A/D techniques.
Lecture 9: D/A and A/D Converters
Precision AC Current Measurement Technique Guildline Instruments Limited.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
1 Lab #7 – Thevenin/Norton Activity #1 – finding the Thevenin/Norton Equivalent for the function generator –The function generator is a voltage source.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Digital to Analog Converters
A Company Selling Technology and not just a Product.
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Oscilloscope Tutorial
POWER AMPLIFIER CHAPTER 4.
OSCILLATORS.
AC Waveform and AC Circuit Theory Md Shahabul Alam Dept: EEE.
Improving Test Ratios Using Reference Multimeters.
Understanding ADC Specifications September Definition of Terms 000 Analogue Input Voltage Digital Output Code FS1/2.
Data Acquisition ET 228 Op –Amp Applications Subjects Covered Overview of OP Amp Applications High Resistance Voltmeters Phase Shifter Circuit Integrators.
Training Making accurate Electrical Measurements.
Extending the workload of the 3000 series calibrators Laboratories usually have to calibrate a very wide variety of instruments. Normal the volume of the.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
CHAPTER 11 Op-Amp Applications. Objectives Describe and Analyze: Audio mixers Integrators Differentiators Peak detectors Comparators Other applications.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
Uncertainties Using & Calculating Uncertainties for Electrical Measurement.
Laboratory Software ProCal Calibration Software ProCal Track Management Software ProSales Pricing & quoting Software.
1 Successive Approximation Analog-to- Digital Conversion at Video Rates 指導教授 :汪輝明 學 生:陳柏宏.
Astable Multivibrators ©Paul Godin Created February 2007 Modified March 2015 Oscillator Basics Technician Series.
Astable Multivibrators ©Paul Godin Created February 2007 Oscillator Basics.
CHEM*3440 Operational Amplifiers These integrated circuits form the backbone of modern instrumental methods. Understanding their operation will help you.
1000 Series Ultra-Portable Multi Function Calibrator Portability, without compromise.
Digital Control CSE 421.
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
USING SCANNERS TO AUTOMATE CALIBRATION. APPLICATIONS FOR SCANNERS IN CALIBRATION 1: Removing lead changing when calibrating Multi-product & Multi function.
Digital-to-Analog Analog-to-Digital Week 10. Data Handling Systems  Both data about the physical world and control signals sent to interact with the.
AMMETER  An ammeter is a measuring instrument used to measure the current in a circuit. Electric currents are measured in amperes (A), hence the name.
Digital Multimeter – Basic Guide
Advances in High Current and Resistance Measurements to 11,000 Amps and Higher Guildline Instruments Limited.
Function Generators. FUNCTION GENERATORS Function generators, which are very important and versatile instruments. provide a variety of output waveforms.
The Digital Multi-Meter (DMM) Dr. Dave Shattuck 1 ECE 2100.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
The Working Theory of an RC Coupled Amplifier in Electronics.
Dr. Michael Nasief.  Rotating electrical machines (ac generators)  Electronic oscillator circuits.
FUNCTION GENERATOR.
CI Lecture Series Summer 2010 An Overview of IQ Modulation and Demodulation Techniques for Cavity LLRF Control.
MECH 373 Instrumentation and Measurements
Mrs V.S.KharoteChavan,E&Tc,PC poly
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Digital Control CSE 421.
(5) DMM & Oscilloscope.
MECH 373 Instrumentation and Measurements
Dr. Unnikrishnan P.C. Professor, EEE
General Licensing Class
ECE 3336 Introduction to Circuits & Electronics
Presentation transcript:

16th July 2013NCSLI 2013, Nashville1

The Design of a Calculable AC voltage reference using digital waveform generation 16th July 2013NCSLI 2013, Nashville2

Abstract The design of an AC voltage reference source using a digital to analogue converter controlled by a microcontroller to produce a calculable RMS AC voltage reference with accuracy suitable for calibrating high performance Digital multimeters. 16th July 2013NCSLI 2013, Nashville3

Technical Objectives To provide a method for secondary and below laboratories with the ability to generate high accuracy AC Voltages Investigate errors associated with digitally generated AC Voltages, as well as the practical application of digitally generated waveforms in commercial calibration 16th July 2013NCSLI 2013, Nashville4

Learning Objectives To investigate alternatives to traditional AC voltage verification methods To enhance calibration laboratories understanding of verification of high performance modern DMM’s 16th July 2013NCSLI 2013, Nashville5

The calibration of Today’s Modern high performance Digital Meters which offer ACV Accuracy in the order of ppm To achieve a stand off ratio of just 4 to 1 requires an accuracy of around 20 ppm. This is not possible with a multi-product calibrator 16th July 2013NCSLI 2013, Nashville6 The Requirement

The Solutions 1) Multi–Junction Thermal Transfer Standard 2) Calculable AC voltage reference 16th July 2013NCSLI 2013, Nashville7

The Solutions : Multi-Junction Thermal Transfer Standard 16th July 2013NCSLI 2013, Nashville8 AdvantagesDisadvantages Wide Frequency RangeRequires both a stable DC and AC voltage source Proven AccuracyEquipment is expensive Calibration is costly, especially when a wide range of points is required Even with protection, older Thermal Transfer devices are easy to damage by accidently over-ranging

The Solutions : Calculable AC Voltage Reference 16th July 2013NCSLI 2013, Nashville9 AdvantagesDisadvantages Due to the nature of the device, does not require an AC or DC source Limited frequency range Instrument can be internally verified with a DC volt meter Output voltages are limited Due to solid state design, instrument is hard to damage with incorrect connections Low cost due to ‘simple’ hardware

The Concept of the Calculable waveform Digitally create an AC waveform using a digital to analogue (DAC) converter. In our experiments we chose a waveform based on 256 steps. Single step the waveform to allow the level of each step to be measured as a DC level. 16th July 2013NCSLI 2013, Nashville10

The Concept of the Calculable waveform The RMS value of the waveform is then calculated using the following formula 16th July 2013NCSLI 2013, Nashville11 Where : Vrms = RMS Ac voltage output V = measured DC voltage of ‘step’ n = number of steps

History This is not a new idea. This technique was pioneered as long ago as 1988 where results against Thermal converters gave uncertainties at the 7 volt level of just 5ppm. 16th July 2013NCSLI 2013, Nashville12

What has changed There is now a much greater need for high accuracy ACV. In 1988 we were only seeing the first developments in High accuracy AC DMM’s. Now almost every laboratory has a high performance DMM 16th July 2013NCSLI 2013, Nashville13

What has changed Digital Electronics along with the rapid development of digital to analogue converters for high quality audio has now made it much easier to implement this concept. 16th July 2013NCSLI 2013, Nashville14

The Circuit The design uses a PIC micro controller, programmed with the waveform to directly drive a DAC. The PIC is directly controlled from an RS232 interface. 16th July 2013NCSLI 2013, Nashville15 Control Interface Micro Controller PIC 16F84 Clock DAC 10V Reference Input AC Voltage Output

The DC Reference The D to A converter needs a short term stable 10Volt DC reference. The Linear Technology LTZ100 reference can easily provide better than 1ppm stability over the short term 2/3 hours required. As the LTZ1000 is temperature stabilised temperature variations over the measurement period will not add any significant contributions to an uncertainty budget 16th July 2013NCSLI 2013, Nashville16

Improvements Vs Performance The circuit used is extremely simple. Early design’s used two converters, with the output being switched between them to remove glitches. With modern converters this is not necessary. The PIC micro controller directly drives the converter, loading the code into the converter directly from it’s memory, also clocking the converter after each data load. This very simple approach requires some machine code for the PIC to make it run as fast as possible. All timing comes from the crystal oscillator driving the PIC. 16th July 2013NCSLI 2013, Nashville17

The Software The AC reference is very simple to control, with just a few commands needed Hz Hz Hz Hz S - Stop waveform and set to zero X - Advance 1 step Y - Advance 10 steps Z - Advance 64 steps 16th July 2013NCSLI 2013, Nashville18

Taking the DCV Measurements The DCV measurements can be taken with a high performance 8 digit DMM. This will typically give full scale & linearity uncertainties of less than 5ppm. As there are over 256 measurements to be made it is recommend that the process be automated by using a PC & software. 16th July 2013NCSLI 2013, Nashville19

Measuring Software A procedure to measure each step was written using Procal. As each step is measured it is squared and added to a running total. The procedure being 256 steps long, takes about 40 minutes to run automatically. Although the measurement procedure could be written in any language Procal has the advantage to work with any DMM without changing code. 16th July 2013NCSLI 2013, Nashville20

Basic Measurement Diagram 16th July 2013NCSLI 2013, Nashville21

Practical Set up 16th July 2013NCSLI 2013, Nashville22

Voltage Range With a 10V input the peak output of the converter will be 10Volts; giving an RMS voltage of 7.07V To get a 1V output the 10Volt output can be resistively divided down allowing the output to still be single stepped and measured on DC. Note an IVD cannot be used to divide down the DC output. However it can be used on the AC output 16th July 2013NCSLI 2013, Nashville23

Errors Switching Glitches and transition This error is most difficult to evaluate. It is dependent on the DAC used. The DAC we have chosen is typically used for audio will be very ‘ clean ’. The approach used by Transmille has been to look at an individual step on a scope and estimate an error based on the size and duration of the transitions. 16th July 2013NCSLI 2013, Nashville24

Errors Switching Glitches and transition Typical figures for this, at a frequency of 50Hz, where there is a step every 80uS, worst case measurements give glitch times of around 8nS, with a glitch size of around 10% of the step. This gives transition errors around the 10ppm level. In practice as some glitches will add and some will subtract the real error will be much less. 16th July 2013NCSLI 2013, Nashville25

Errors from Rise / fall times & DC offsets Rise and Fall time Providing the rise and fall times are equal they do not contribute to errors. The error caused by a difference in rise/fall times can be mathematically calculated DC offsets Any DC offsets in the DAC will be measured and added to the calculated RMS figure. However if the device being calibrated is AC coupled DC offsets in the AC output will give an error and it may be best to trim any offsets out to avoid this problem. 16th July 2013NCSLI 2013, Nashville26

Errors from Loading effects Output Loading When measuring the output with a thermal converter the load effect on the 2 wire output will need to be considered. When using measuring the output with a typical DMM loading effects will be negligible 16th July 2013NCSLI 2013, Nashville27

Errors from drift in DC Reference Source & DAC As the AC source is a transfer device it is only the short term drift between the DC measurement of the system and the subsequent use on AC that contributes to the error. Long term changes in the reference or the DAC linearity or gain do not contribute as the system is calibrated before use. 16th July 2013NCSLI 2013, Nashville28

Uncertainties Typical laboratory figures for uncertainty Imported DC Voltage Measurement 5ppm Resolution of DC voltage Measurement0.1ppm Switching transition errors10ppm Short term stability of DC reference and DAC*2ppm Combining for 95% (K=2) gives13ppm * Includes effects of temperature for +/- 2’C from Tcal 16th July 2013NCSLI 2013, Nashville29

Verifying the accuracy Measurements made by Transmille Transmille best AC measurement capability uses our Fluke 540b thermal transfer, the accuracy of this Instrument is enhanced by measuring the output of the thermal converter directly. Loading effects on both AC and DC measurements were compensated for. Tests performed against a Wavetek 4920, Transmille 8081, Agilent 3458A and Fluke 8508A provided similar results. Typical readings obtained Single step calculation = Measurement by thermal Transfer 540B = Error = 14 ppm 16th July 2013NCSLI 2013, Nashville30

Frequency Range To date Transmille’s interest has been In the frequency range 40Hz to 1kHz. The design could generate frequencies below 1Hz with no additional errors. Frequencies up to 10kHz could also be generated with increased error from switching. 16th July 2013NCSLI 2013, Nashville31

Improvements …… Extending the Voltage range. A simple resistive divider to provide 1V and 100mV outputs. A DC voltage amplifier to provide a 100V output. Both could be again ‘calibrated’ at DC using a known DMM to provide the calculated AC RMS value 16th July 2013NCSLI 2013, Nashville32

Other Functions…… Non sine wave outputs With this method it would be very easy to generate other wave shapes to evaluate performance of converters including crest factor. 16th July 2013NCSLI 2013, Nashville33

Power and Phase….. Future development of this technique could be to add additional converters to allow for several outputs. Up to 6 outputs could easily be provided for 3 phase simulation of power, with an accurate phase, or delay between the outputs. If all the outputs were at the same 7V level this would provide a very affordable solution for a phase and power reference. 16th July 2013NCSLI 2013, Nashville34

References [1] R. Kinard, and L. A. Harris “ A digitally synthesized sine wave source with +/- 1 ppm amplitude stability. “ in Euromeas ’77 Conf Digest. Institute Elect. Eng. Conf. Pub no 152, Sept [2] Oldham N., Hetrick P., Zeng X., “A Calculable, Transportable Audio Frequency AC Reference Standard”. IEEE Transactions on I & M, April 1989, Vol. 38. [3] Oldham N., Bruce W., FU C., Cohee A., Smith A., “An Intercomparison of AC Voltage Using A Digitally Synthesized Source”. IEEE Transactions on I & M Vol. 39 No. 1, February th July 2013NCSLI 2013, Nashville35

Conclusions Digital synthesized waveforms can provide a low cost and easy to use solution for DC to AC voltage transfer. Copies of our paper and presentation are available by signing up to our newsletter 16th July 2013NCSLI 2013, Nashville36