Slide 1 Copyright : Valiant Communications Limited. - 2010 Slide 1 VCL-SafeComm 8 E1 Links (24 E1 Ports) Orion Telecom Networks Inc. - 2010 Updated: April,

Slides:



Advertisements
Similar presentations
Copyright: Valiant Communications Limited Slide 1 Ethernet over E1 (FE1) Product Presentation Updated: 29 April, 2010 V aliant C ommunications L.
Advertisements

Slide 1 Copyright : Valiant Communications Limited Slide 1 Ethernet over DS3 Switch Updated: April, 2010 V aliant C ommunications L imited Telecom.
Slide 1 Copyright : Valiant Communications Limited Slide 1 DS3 Fail-over Protection Switch Orion Telecom Networks Inc Updated: April, 2010.
Slide 1Copyright : Valiant Communications Limited x VCL-T1 Over Ethernet Multiplexer (TDM Over IP) V aliant C ommunications L imited Telecom Transmission.
Slide 1 Orion Telecom Networks Inc Slide 1 XC 64 E1 Electronic Patch Panel xcvcxv Updated: Nov, 2010Orion Telecom Networks Inc XC 64 Port.
Copyright, Valiant Communications Limited Valiants Remote Alarm Reporting and Site Monitoring Equipment Confidential Slide 1 V aliant C ommunications.
Product Presentation 2xE1/T1 over Ethernet Multiplexer (TDMoIP)
Slide 1 Orion Telecom Networks Inc Slide 1 DS3 Fail-over Protection Switch xcvcxv Updated: April, 2010Orion Telecom Networks Inc DS3 Fail-over.
Slide 1 Copyright : Valiant Communications Limited Slide 1 4 E1 + Ethernet PDH Optical Multiplexer Updated: April, 2010 V aliant C ommunications.
Copyright, Valiant Communications Limited VCL-SR-MUX V aliant C ommunications L imited Telecom Transmission Solutions Confidential Slide 1 G.703,
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-MX, E1 Voice & Data Drop-Insert Multiplexer Updated: April, 2010 VCL-MX™ Version.
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-MX, E1 Voice & Data Drop-Insert Multiplexer Updated: April, 2010 VCL-MX™ Version.
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-MX, E1 Voice & Data Drop-Insert Multiplexer Updated: April, 2010 V aliant C ommunications.
Slide 1 VCL-SafeComm 16 T1 Links (48 T1 Ports) Copyright : Valiant Communications Limited Slide 1 Updated: April, 2010 Telecom Transmission Solutions.
Slide 1Copyright : Valiant Communications Limited Port T1 VCL-MegaConnect-Jr. Digital Access Cross Connect Switch (DACS) V aliant C ommunications.
Slide 1Copyright : Valiant Communications Limited V aliant C ommunications L imited Telecom Transmission Solutions Updated : March, Port.
Slide 1 Orion Telecom Networks Inc Slide 1 VCL-MegaConnect TM 16 Port Plus - E1 Monitoring Groomer xcvcxv Updated: April, 2010Orion Telecom Networks.
Slide 1 Orion Telecom Networks Inc Slide 1 VCL-SafeComm 16 E1 Links (48 E1 Ports) xcvcxv Updated: Aug, 2012Orion Telecom Networks Inc VCL-SafeComm.
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-MegaConnect TM 16 Port Plus - E1 Monitoring Groomer Updated: April, 2010 VCL-MegaConnect.
Valiant Communications Limited
Copyright : Valiant Communications Limited Slide 1 VCL-EC TM T1 Echo Canceller Desktop Version (Modem Type) V aliant C ommunications L imited Telecom.
Copyright : Valiant Communications Limited Slide 1 VCL-2/34 Mbps Multiplexer E3, PDH Multiplexer V aliant C ommunications L imited Telecom Transmission.
Valiant Communications Limited Slide 1 Updated : January, 2006 V aliant C ommunications L imited Telecom Transmission Solutions VCL-E3 OLTE 34Mbps.
Slide 1Copyright : Valiant Communications Limited VCL-MX Version 3-DLX (Deluxe Version) VCL-MX™ Version 3-DLX (Deluxe Version) 4 x E1, Drop-Insert.
Slide 1 Copyright : Valiant Communications Limited Slide 1 Orion Telecom Networks Inc Updated: April, 2010 V aliant C ommunications L imited.
Slide 1 Orion Telecom Networks Inc Slide 1 xcvcxv Updated: April, 2010Orion Telecom Networks Inc SafeComm 16 T1 Links (48 T1 Ports) (1+1.
Slide 1 Orion Telecom Networks Inc Slide 1 VCL-HSL 64 T1 Port Hi-Z Monitoring Equipment xcvcxv Updated: Nov, 2010Orion Telecom Networks Inc
Copyright, Valiant Communications Limited -2006Slide 1 VCL MegaConnect 64 Port E1 / T1 / 10 BaseT Ethernet Digital Access Cross Connect Updated : January,
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-HSL 64 E1 Port Hi-Z Monitoring Equipment Updated: November, 2010 Product Presentation.
Slide 1 Copyright : Valiant Communications Limited Slide 1 Orion Telecom Networks Inc Updated: April, 2010 V aliant C ommunications L imited.
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-MegaConnect TM 64 Port Plus - E1 Monitoring Groomer Updated: April, 2010 VCL-MegaConnect.
Slide 1 Orion Telecom Networks Inc Slide 1 VCL-MegaConnect TM 64 Port Plus - E1 Monitoring Groomer xcvcxv Updated: April, 2010Orion Telecom Networks.
Copyright : Valiant Communications Limited Slide 1 E2, 2Mbps x 4 Opti Multiplexer Integrated E2, OLTE and Multiplexer V aliant C ommunications L.
Copyright : Valiant Communications Limited Slide 1 Updated: Feb, 2014 VCL-SafeComm 16 E1 Links (48 E1 Ports) (1+1 Automatic Protection Switch)
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-MegaConnect TM 32 Port Plus - E1 Monitoring Groomer Updated: April, 2010 VCL-MegaConnect.
Orion Telecom Networks Inc Slide 1 16 E1 + Gigabit Ethernet (Wire-Speed) Optical Multiplexer Updated: Jan, 2011Orion Telecom Networks Inc
Slide 1 Orion Telecom Networks Inc Slide 1 E1 Protection Fail-over Switch xcvcxv Updated: Aug, 2012Orion Telecom Networks Inc E1 Protection.
Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-SafeComm 8 E1 Links (24 E1 Ports) Orion Telecom Networks Inc Updated: Feb,
Copyright, Valiant Communications Limited VCL-30, iDSL DSLAM ™ Confidential Slide 1 V aliant C ommunications L imited Telecom Transmission Solutions.
Copyright, Valiant Communications Limited E1 Protection Switching Equipment Confidential Slide 1 V aliant C ommunications L imited Telecom Transmission.
Copyright, Valiant Communications Limited -2006Slide 1 64 Port E1 / T1 Digital Access Cross Connect 32 Port E1 / T1 Monitoring GROOMER Updated : January,
Orion Telecom Networks Inc E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide , Avenue of.
Copyright: Valiant Communications Limited Slide 1 1 x E1/T1 over Ethernet Multiplexer (TDMoIP) 1 x E1/T1 over Ethernet Multiplexer (TDMoIP) Product.
Slide 1 Copyright : Valiant Communications Limited Slide 1 Ethernet over E3 Switch Updated: May, 2013 Ethernet over E3 Switch Product Presentation.
Copyright : Valiant Communications Limited Slide 1 V aliant C ommunications L imited Telecom Transmission Solutions 4 x VCL-E1 Over Ethernet Multiplexer.
Copyright, Valiant Communications Limited Slide 1 32 Port E1 Monitoring GROOMER V aliant C ommunications L imited Telecom Transmission Solutions.
Copyright : Valiant Communications Limited Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Product Presentation.
VCL-MX Version 6 DXC 80 E1, 160Mbps Digital Access Cross Connect Switch.
Copyright: Valiant Communications Limited Slide 1 8/16 x E1/T1 over Ethernet Multiplexer (TDMoIP) 8/16 x E1/T1 over Ethernet Multiplexer (TDMoIP)
Valiant Communications Limited Slide 1 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : January, 2006 V aliant C ommunications.
Copyright: Valiant Communications Limited Slide 1 2 x E1/T1 over Ethernet Multiplexer (TDMoIP) 2 x E1/T1 over Ethernet Multiplexer (TDMoIP) Product.
4 x Ethernet over E1(4*FE1) Copyright: Valiant Communications Limited Slide 1 4 Ethernet over E1 (4xFE1) Product Presentation Updated: 29 April,
Copyright : Valiant Communications Limited Slide 1 VCL-MX Version 2 – DLX (Deluxe Version) VCL-MX™ Version 2-DLX (Deluxe Version) 4 x E1, 30 Channel.
Copyright: Valiant Communications Limited Slide 1 Ethernet over E1 (FE1) Product Presentation Updated: 29 April, 2010.
Slide 1 Orion Telecom Networks Inc Slide 1 T1 Protection Fail-over Switch xcvcxv Updated: April, 2010Orion Telecom Networks Inc T1 Protection.
VCL-SE IEEE-1588v2 PTP Protected Synchronous Packet-Optical Transport Interface Presentation.
Digital Access Cross Connect Switch
12 E1 Voice & Data Multiplexer
Ethernet over DS3 Switch
1+1 Ethernet Failover & Network Protection Switches
DS3 Fail-over Protection Switch
E1 Protection Fail-over Switch
Valiant Communications Limited
Valiant Communications Limited
Valiant Communications Limited
VCL-MX™ Version 3-DLX (Deluxe Version)
Valiant Communications Limited
Valiant Communications Limited
VCL-MX™ Version 2-DLX (Deluxe Version) 4 x E1, 30 Channel Drop-Insert
Presentation transcript:

Slide 1 Copyright : Valiant Communications Limited Slide 1 VCL-SafeComm 8 E1 Links (24 E1 Ports) Orion Telecom Networks Inc Updated: April, 2010 V aliant C ommunications L imited Telecom Transmission Solutions VCL-SafeComm 8 E1 Links (24 E1 Ports) (1+1 Automatic Protection Switch) Product Presentation

Slide 2 Copyright : Valiant Communications Limited Slide 2 VCL-SafeComm 8 E1 Links (24 E1 Ports) Product Overview  Used to protect upto 8 point-to-point E1 links and to provide an alternate communication route for each E1 Link between any two points in a network  In the event of the failure of the primary (main) E1communication route, the VCL-SafeComm, 8 E1 Links 1+1 APS equipment, automatically switches the E1 traffic to a secondary (standby) E1 route  May also be used in point-to-multi-point applications to provide 1+1 Protected / Alternate Routing Path between multiple locations.  Data transported on the E1 Links is transparent and protocol independent  SNMP V2 Traps for alarm reporting.  Available in a 2U high, 19-Inch rack mount chassis.

Slide 3 Copyright : Valiant Communications Limited Slide 3 VCL-SafeComm 8 E1 Links (24 E1 Ports) Applications :  Allows the user to design 1+1 (protected) redundant E1 routes on similar (fiber-fiber), or complementing (fiber-radio) transmission mediums  Transport A-bis Interface on redundant E1 links  Provide 1+1 Protection / Alternate Routing Path between BSC and BTS  Used to design 1+1 redundant (protected) E1 rings on PDH networks, which otherwise would not be possible with PDH technology  The criterion for switching between the primary (main) and the secondary (protected/standby) routes is user programmable is Loss-Of- Signal on E1 links, or AIS (All-Ones AIS alarm) condition  May be used in a point-to-multipoint configuration to provide 1+1 Protected / Alternate Routing Path between one location and multiple locations (as shown in application diagram).

Slide 4 Copyright : Valiant Communications Limited Slide 4 VCL-SafeComm 8 E1 Links (24 E1 Ports) VCL-SafeComm 8 E1 Links (24 E1 Ports) Front View:

Slide 5 Copyright : Valiant Communications Limited Slide 5 VCL-SafeComm 8 E1 Links (24 E1 Ports) Features and Highlights:  High density protection switching equipment (upto 8 E1 Links i.e. 24 E1 Ports)  Ensures that mission critical voice, data, control and management traffic links are maintained even if either the primary or the secondary E1 backhaul transmission links fail  When the primary (working) link fails, the E1 traffic is automatically switched to the standby (secondary) link to ensure maximum link uptime  Offers comprehensive remote configuration and alarm management capabilities of the VCL-SafeComm, 8 E1, 1+1 Automatic Protection Switching  Equipment the product may be used to improve network reliability and control  Increased network reliability through link resilience.

Slide 6 Copyright : Valiant Communications Limited Slide 6 VCL-SafeComm 8 E1 Links (24 E1 Ports) User Programmable 1+1 Protection Switching Parameters: Features and Highlights:  Media and Path Diversity  Remote Management  Alarm logging and monitoring  Dual -48V DC Power Inputs.  Loss of Signal  AIS (All Ones Alarm).

Slide 7 Copyright : Valiant Communications Limited Slide 7 VCL-SafeComm 8 E1 Links (24 E1 Ports) Salient Features:  VCL-SafeComm 1+1 Protection Switch does not "add" a point-of-failure to the E1 network.  Even in the event that the power to the VCL-SafeComm 1+1 Protection Switch (or the equipment itself) fails, the E1 link connectivity shall be "always" maintained." The E1 link integrity is ALWAYS maintained (the switch reverts the connection to the primary E1 link), even if the power to the equipment is disconnected and removed. This ensures that the E1 link connectivity is never lost.  VCL-SafeComm 1+1 Protection Switch provides two power inputs and this allows the user to connect the switch to two separate independent -48V DC power sources to minimize the chances of any power failure occurring due to power outage.

Slide 8 Copyright : Valiant Communications Limited Slide 8 VCL-SafeComm 8 E1 Links (24 E1 Ports) Modes of Operation: There are three modes in which the VCL-SafeComm E1, 1+1 Automatic Protection Switch can be configured to operate in:  AUTOMATIC SWITCHING MODE  EXTERNAL TRIGGER SWITCHING MODE  MANUAL SWITCHING MODE

Slide 9 Copyright : Valiant Communications Limited Slide 9 VCL-SafeComm 8 E1 Links (24 E1 Ports) AUTOMATIC SWITCHING MODE  The VCL-SafeComm can be configured to operate in an AUTOMATIC SWITCHING MODE. In the automatic mode, the switch shall automatically switch and re-route the E1 circuits from the MAIN route to the STANDBY route if there is an AIS or a LOS (LOSS OF SIGNAL) alarm, on the MAIN E1 link route.  Similarly, in the automatic mode the switch shall automatically switch back and re-route the E1 circuits from the STANDBY route to the MAIN route, upon the restoration of the service on the MAIN E1 link route.  All switching parameters and link restoration parameters are user programmable.

Slide 10 Copyright : Valiant Communications Limited Slide 10 VCL-SafeComm 8 E1 Links (24 E1 Ports) EXTERNAL TRIGGER SWITCHING MODE  Sometimes the user wants to switch the E1 circuits between the MAIN route and the STANDBY route when some external event occurs.  In the EXTERNAL TRIGGER MODE, the user can switch between the MAIN E1 route and the STANDBY E1 route when an external trigger (such as an closed/opened physical contact) is applied to the switch.  This unique feature is used by certain radios equipment suppliers, where they apply an external trigger to switch and re-route the E1 circuits between their main E1 radios and standby E1 radios.

Slide 11 Copyright : Valiant Communications Limited Slide 11 VCL-SafeComm 8 E1 Links (24 E1 Ports) MANUAL SWITCHING MODE  In Manual Switching Mode, the user shall use manual Telnet commands to switch the E1 circuits between the MAIN route and the STANDBY route, manually, using Telnet commands.  In this mode the AUTOMATIC MODE and the EXTERNAL TRIGGER MODE are both disabled and the manual commands over ride all other modes.

Slide 12 Copyright : Valiant Communications Limited Slide 12 VCL-SafeComm 8 E1 Links (24 E1 Ports) Switching Criterion and Time E1 Switching Criterion User Programmable 1+1 Protection Criterion a) Loss of Signal b) AIS (All Ones Alarm) Minimum E1 Switching Time from10 ms. to 3000 ms. (User Programmable) Main Link To Standby Link Minimum E1 (Recovery) Switching 10 ms. to 9999 ms. (User Programmable) Time From Standby Link to Main Link Switching ModeUser can program the APS to stay on Standby Port a) Auto when the Main link is restored. b) Force ON Main c) Force ON Standby

Slide 13 Copyright : Valiant Communications Limited Slide 13 VCL-SafeComm 8 E1 Links (24 E1 Ports) Application Diagram – Simply Explained:

Slide 14 Copyright : Valiant Communications Limited Slide 14 VCL-SafeComm 8 E1 Links (24 E1 Ports) Application Diagram - To provide redundant routes over diverse media: SafeComm 8 E1 Links (24 E1 Ports)

Slide 15 Copyright : Valiant Communications Limited Slide 15 VCL-SafeComm 8 E1 Links (24 E1 Ports) Application Diagram - PDH Protected Ring:

Slide 16 Copyright : Valiant Communications Limited Slide 16 VCL-SafeComm 8 E1 Links (24 E1 Ports) Thank you for your attention For more details visit us at our Website at U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, Uxbridge Road, London W3 9QN, United Kingdom Website: U.S.A. Valcomm Technologies Inc Ponce de Leon, Suite 470 Coral Gables, FL United States of America Website: INDIA Valiant Communications Limited 71/1, Shivaji Marg, New Delhi , India Website: