Intermediate Silicon Tracker For STAR HFT Upgrade Yaping Wang 1, 3, Gerrit J. van Nieuwenhuizen 2, Zhenyu Ye 1, 3 for the STAR Collaboration 1 University.

Slides:



Advertisements
Similar presentations
Silicon Verterx Tracker Upgrade of PHENIX Experiment at RHIC Y. Akiba (RIKEN) CIPANP2003 New York, New York May 2003.
Advertisements

The STAR Heavy Flavor Tracker Flemming Videbæk For the STAR collaboration Brookhaven National Lab 1.
The Belle Silicon Vertex Detector T. Tsuboyama (KEK) 6 Dec Workshop New Hadrons with Various Flavors 6-7 Dec Nagoya Univ.
HFT Technical Overview September 26, HFT 2013 TPC FGT 2011 STAR Detectors Fast and Full azimuthal particle identification EMC+EEMC+FMS (-1 ≤ 
STAR Heavy Flavor Tracker
STAR Heavy Flavor Tracker
Heavy Flavor Physics in HIC with STAR Heavy Flavor Tracker Yifei Zhang (for the STAR HFT Group) Hirschegg 2010, Austria Outline:  Physics motivation 
H eavy F lavor T racker : a silicon inner tracking upgrade for STAR Jonathan Bouchet (Kent State University) for the STAR collaboration Poster 907, April.
1 Jim Thomas – The Berkeley Lab Three Abstracts for QM 2011 Instrumentation Session The Heavy Flavor Tracker (HFT) The Muon Telescope Detector (MTD) A.
PHENIX Vertex Tracker Atsushi Taketani for PHENIX collaboration RIKEN Nishina Center RIKEN Brookhaven Research Center 1.Over view of Vertex detector 2.Physics.
STAR upgrade workshop, Yale, Jun , People: F. Bieser, R. Gareus, L. Greiner, H. Matis, M. Oldenburg, F. Retiere, H.G. Ritter, K.S., A. Shabetai(IReS),
1 STAR HFT S. Margetis, Kent State University STAR Regional Meeting, February 11, 2015, Prague.
L. Greiner 1IPHC meeting – September 5-6, 2011 STAR HFT Plans for the next year A short report on review results and plans for TPC – Time Projection.
L. Greiner1SLAC Test Beam 03/17/2011 STAR LBNL Leo Greiner, Eric Anderssen, Howard Matis, Thorsten Stezelberger, Joe Silber, Xiangming Sun, Michal Szelezniak,
The Physics Potential of the PHENIX VTX and FVTX Detectors Eric J. Mannel WWND 13-Apr-2012.
L. Greiner1PXL Sensor and RDO review – 06/23/2010 STAR Heavy Flavor Tracker Overview With parameters pertinent to the PXL Sensor and RDO design.
STAR HFT STAR Collaboration Meeting - LBNL MIT/MIT-Bates Gerrit van Nieuwenhuizen, Stephen Steadman, Jim Kelsey, Ben Buck, Peter Goodwin Jason.
SSD Operations Manual March 2014 SSD: 4 th layer of vertex detector Heavy Flavor Tracker Silicon Strip Detector – Operations Manual PXL Inserted from this.
HFT Project Overview CD0 Review H.G. Ritter LBNL.
David L. Winter for the PHENIX Collaboration PHENIX Silicon Detector Upgrades RHIC & AGS Annual Users' Meeting Workshop 3 RHIC Future: New Physics Through.
Jim Thomas - LBL 1 HFT Performance & Simulation Studies Experience Gained by Simulating One Track at a Time Jim Thomas Lawrence Berkeley National Laboratory.
1 Jim Thomas - LBL STAR Inner Tracking Upgrades with an emphasis on the Heavy Flavor Tracker presented by Jim Thomas Lawrence Berkeley Laboratory 11 /
X,Sun1USTC discussion, Oct 15, 2010 STAR STAR Heavy Flavor Tracker Upgrade --Status of PXL Detector Xiangming Sun Lawrence Berkeley National Lab L. Greiner,
X,Sun1STAR Regional Meeting, Oct 23, 2010, SDU STAR STAR Heavy Flavor Tracker Upgrade --Status of PXL Detector Xiangming Sun( 孙向明 ) Lawrence Berkeley National.
HFT + TOF: Heavy Flavor Physics Yifei Zhang University of Science & Technology of China Lawrence Berkeley National Lab TOF Workshop, Hangzhou, April,
Heavy Flavor Physics in STAR Flemming Videbæk Brookhaven National Laboratory For the STAR collaboration.
L. Greiner 1IPHC meeting – May 7, 2012 STAR HFT Plans for the next year A short report on HFT/PXL plans for post May 2012 TPC – Time Projection Chamber.
High-resolution, fast and radiation-hard silicon tracking station CBM collaboration meeting March 2005 STS working group.
STAR RHIC AGS users meeting, May 30, Star Inner Tracking upgrade F. Videbaek STAR collaboration for the HFT upgrade group.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Spiros Margetis (Kent State Univ.) for the STAR Collaboration STAR Heavy Flavor Tracker Bari, Italy 2014.
STAR Spin Related Future Upgrades STAR Spin Physics Program Current Capabilities Heavy Flavor Physics W Program Transverse Program Upgrades: Plans & Technologies.
1 Jim Thomas - LBL HFT Issues that may Bear on the Fate of the SSD & SVT presented by Jim Thomas 07/07/2006.
Operation of the CMS Tracker at the Large Hadron Collider
X. DongSept. 3rd, 2013 USTC, Hefei, China 1 The Heavy Flavor Tracker for STAR Xin Dong Lawrence Berkeley National Laboratory SSD IST PXL HFT.
Swadhin Taneja Stony Brook University On behalf of Vertex detector team at PHENIX Collaboration 112/2/2015S. Taneja -- DNP Conference, Santa Fe Nov 1-6.
L. Greiner 1IPHC meeting – May 7, 2012 STAR HFT Plans for the next year A short report on HFT/PXL plans for post May 2012 TPC – Time Projection Chamber.
G. Contin | The STAR Heavy Flavor Tracker (HFT) and Upgrade Plan Quark Matter 2015 – Kobe, Japan Session : Future Experimental Facilities,
Measurement of D-meson azimuthal anisotropy in Au+Au 200GeV collisions at RHIC Michael R. Lomnitz Kent State University Lawrence Berkeley National Laboratory.
1 Performance of the STAR Heavy Flavor Tracker in Measuring Charged B Meson through charged B  J/Ψ + X Decay.
Spin Physics with the PHENIX Silicon Vertex Tracker Junji Tojo RIKEN for the PHENIX Collaboration Advanced Studies Institutes - Symmetries and Spin July.
2007 Run Update for STAR Jeff Landgraf For the STAR collaboration.
Jonathan BouchetBerkeley School on Collective Dynamics 1 Performance of the Silicon Strip Detector of the STAR Experiment Jonathan Bouchet Subatech STAR.
Non-photonic electron production in p+p collisions at √s=200 GeV Xiaozhi Bai for the STAR collaboration Central China Normal University University of Illinois.
Future Possibilities for Measuring Low Mass Lepton Pairs in Christine Aidala for the Collaboration Quark Matter 2002, Nantes.
First CMS Results with LHC Beam
Feasibility study of Heavy Flavor tagging with charged kaons in Au-Au Collisions at √s=200 GeV triggered by High Transverse Momentum Electrons. E.Kistenev,
1 Guannan Xie Nuclear Modification Factor of D 0 Mesons in Au+Au Collisions at √s NN = 200 GeV Lawrence Berkeley National Laboratory University of Science.
High Density Matter and Searches for Huan Z. Huang Department of Physics and Astronomy University of California, Los Angeles The STAR Collaboration.
International Workshop on Radiation Imaging Detectors, Glasgow, July 25-29, 2004 Johann M. Heuser, RIKEN for the PHENIX Collaboration - RHIC and PHENIX.
Heavy Flavor Physics in STAR Flemming Videbæk Brookhaven National Laboratory For the STAR collaboration.
Status of the STAR tracking upgrade Gerrit van Nieuwenhuizen STAR Collaboration Meeting BNL, February 24, 2005.
The Collider Detector at Fermilab (aka CDF) Jennifer Pursley Intermediate Seminar Oct. 28, 2003.
SPHENIX Mid-rapidity extensions: Additional Tracking system and pre-shower Y. Akiba (RIKEN/RBRC) sPHENIX workfest July 29,
NSS2006Shengli Huang1 The Time of Flight Detector Upgrade at PHENIX Shengli Huang PHENIX Collaboration Outlines: 1.Physics motivations 2.Multi-gap Resistive.
1 Preliminary Considerations on Tracking for HIEPA Yifei Zhang and Jianbei Liu University of Science and Technology of China Workshop on Physics at Future.
Non-Prompt J/ψ Measurements at STAR Zaochen Ye for the STAR Collaboration University of Illinois at Chicago The STAR Collaboration:
Pixel 3D Sensor Test Beam Analysis
The STAR Heavy Flavor Tracker PXL detector readout electronics
 Silicon Vertex Detector Upgrade for the Belle II Experiment
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
Future prospects for NA61 heavy ions: rare observables
Software Overview S. Margetis Kent State University HFT CD0 Review.
Jonathan Bouchet, For the STAR collaboration
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Physics with the HFT prototype?
Simulation on the Response of the STAR HFT Pixel Detector
Performance of the STAR Heavy Flavor Tracker in measuring the charged B meson through B  J/Ψ + X decay Elizabeth Brost Department of Physics, Grinnell.
Simulation on the Response of the STAR HFT Pixel Detector
Tracking in SuperLHC 1. Radiation damage
Presentation transcript:

Intermediate Silicon Tracker For STAR HFT Upgrade Yaping Wang 1, 3, Gerrit J. van Nieuwenhuizen 2, Zhenyu Ye 1, 3 for the STAR Collaboration 1 University of Illinois at Chicago, 2 Massachusetts Institute of Technology, 3 Central China Normal University 1. Physics Motivation4. Performance of IST in Cosmic Run and Au+Au 200 GeV Collisions 5. Performance of IST in GeV 3. IST Geometry, Production and Survey HFT is designed to enhance STAR’s capability for heavy flavor studies. IST is a sub-detector of HFT: (1) based on silicon micro-strip technology; (2) Fast readout and reasonable position resolution; (3) Performance of the IST meets design goals; (4) Data taking for GeV in Abstract The Heavy Flavor Tracker (HFT) has been installed in the STAR experiment at the Relativistic Heavy Ion Collider since January It greatly enhances the capability for heavy flavor studies by measurements of displaced vertices and direct topological reconstruction of open charm hadrons. The HFT consists of two inner layers of silicon pixel detectors, an intermediate layer of silicon pad detector and an outer layer of silicon strip detector. The Intermediate Silicon Tracker (IST) is the third layer made of silicon pad sensors, which have a position resolution of about 170 (1800) microns in the r-ϕ (z) direction. In this poster, we will present the design of the IST detector system, and its performance in the cosmic ray tests and ongoing physics data taking in Au-Au collisions. Detector Radius (cm) Hit Resolution R/  - Z (  m -  m) Radiation length SSD2220 / 7401% X 0 IST14170 / 1800<1.5% X 0 PIXEL 812/ 12~0.6% X / 12~0.4% X 0 IST (Intermediate Silicon Tracker) 1 layer of silicon pad sensors Guiding tracks from the SSD to the PIXEL Fast readout detector (40 MHz sampling rate, 4 μs analogue pipeline) D 0  K - π +, cτ ~ 120 μm Heavy Flavor Tracker (HFT) will greatly enhance the capability of STAR for heavy flavor studies (energy loss mechanism and partonic thermalization), allowing identification of displaced vertices and direct topological reconstruction of open charm hadrons. 2. Technical Design ϕ-Coverage2π |η|-Coverage≤1.2 Number of Staves24 Number of hybrids24 Number of sensors144 Number of readout chips864 Number of channels r-ϕ resolution172 μm Z resolution1811 μm R-ϕ pad size594 μm Z pad size6275 μm IST stave = Carbon fiber ladder + Kapton flex hybrid + Passive components + 6 silicon pad sensors + 3 x 12 APV25-S1 readout chips + Aluminium cooling tube + Liquid coolant (3M Novec 7200) ~ 50 cm 300 μm Hamamatsu sensor ( 64 × 12 pads) Event display IST hit finding efficiency decrease versus channel offline threshold, ~95% with 2*pad size cut Residual resolution matches design goal (Straight line projection to IST by 2 PXL hits, 2 back-to-back PXL tracks required each event. Survey data were used for IST ladder and PXL sector, and alignment data for others of top level) Signal-to-Noise ratio (typical value after track angle correction): 23:1 6. Summary The HFT has been collecting data in the RHIC Au+Au 200 GeV run. The IST performance is stable and good. Main performance is summarized below: Stable pedestal and RMS level over all channels (96.4% good chips, and 96% good channels) Reasonable Residual resolution (Helix projection to IST by TPC track reconstructed with 2 PXL hits included; Survey data were used for IST/PXL ladders and sensors, and alignment data for others of top level. – See details in Michael Lomnitz’s poster MPV ~ 440 ADCs Pedestal RMS noise 1) carbon foam 2) carbon honeycomb 3) west carbon end-cap 4) east Al end-cap 5) carbon fiber skins 6) Kapton hybrid 7) Al cooling tube with cooling liquid inside 8) thermal sensor 9) silicon sensors 10) APV chips 11) support blocks 12) screws with washers 13) spacers 14) transition board 15) readout connectors. Optical Gaging Products Avant 600 (Automated video measuring system with ~0.5 micron XYZ resolution) Two reproducible survey data sets for each stave with difference ≤ 3 (10) microns in X-Z (Y) IST staves were assembled/tested/surveyed at UIC/FNAL and MIT/BNL sites (18 staves produced at each site). σ = ± cm σ = ± cm σ = ± cmσ = ± cmσ = ± cm IST: red layer PXL: blue layers Channel Threshold [/Noise]