Revolutionary Technology in pH Measurement

Slides:



Advertisements
Similar presentations
Information Security of Embedded Systems : Embedded Systems Design Prof. Dr. Holger Schlingloff Institut für Informatik und Fraunhofer FIRST.
Advertisements

M. Mayer SEWG Fuel Retention June Sample Analysis for TS, AUG and JET: Depth Profiling of Deuterium M. Mayer Max-Planck-Institut für Plasmaphysik,
Display Systems and photosensors (Part 2)
Carl Wirdak Occidental Petroleum Corporation GEMI Survey Water Use, Issues & Management March 2001.
OFFLINE COMPOSITION MEASURING SENSORS
Modulation of conductive property in VO 2 nano-wires through an air gap-mediated electric field Tsubasa Sasaki (Tanaka-lab) 2013/10/30.
Sensor Operating Theory
Panel 3D = XML file pointer 08/09/20091 LHCb calorimeter meeting (jean-luc PANAZOL)
Chem. 133 – 2/12 Lecture. Announcements Lab Work –Supposed to Cover Set 2 Labs – but I probably won’t cover all and then will give an extra day for period.
Summary of Potentiometry:
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Luminescence Dissolved Oxygen
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?
1 Microelectronics Processing Course - J. Salzman - Jan Microelectronics Processing Oxidation.
Measurement of Dissolved Oxygen with a Luminescence-based Oxygen Quenching Sensor By Cary B. Jackson, Ph.D. Hach Company.
WORKING PRINCIPLE OF DO AND pH PROBE Prepared by: Tan See Yean Yuganesh a/l Murugiah Jelita Bungin Nazzira Md Zin.
Semiconductor Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
Contents : CONSTRUCTION PRINCIPLE OF OPERATION CHARACTERISTICS ADVANTAGES DISADVANTAGES APPLICATION.
Dr. Marc Madou Class II. Electrochemistry Background (I) Winter 2009 BIOMEMS.
PH probe
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering pH measurements The probe, from chemistry to voltage to a number + + V.
Lasers and Optics By Adam Abawi. Lasers vs. Light A laser differs from other sources of light in that it emits light in a narrow straight line A laser.
BASIC ELECTRONICS.
Nelson Research, Inc – N. 88 th St. Seattle, WA USA aol.com Bubble Detection Sensors for Non-conducting Liquids Craig.
WEEK ONE TOPIC: ELECTRONICS SOLID STATE MATERIALS  CONDUCTORS  INSULATORS  SEMICONDUCTORS.
DC Analysis Representation of diode into three models Ideal case – model 1 with V  = 0 Piecewise linear model 2 with V  has a given value Piecewise linear.
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
Section 2.1 Controlling the Flow of Electrical Current.
Atomic Absorption Spectrophotometer
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
Sensors and Electricity. What is a Sensor? A sensor is a device that: A sensor is a device that: 1) Measures a physical quantity 2) Converts this measurement.
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Section 2 Current. Voltage and Current Electrical Potential Energy: the ability to move an electrical charge from one point to another. Depends on position.
MOCT(Magneto Optic Current Transduser)
Biomedical Electrodes, Sensors, and Transducers
Electrochemical Cells in Actions Batteries and Fuel Cells Chapter 15.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Basic electronic components A review
Electricity Current and charge. Electricity The flow of an electrical current Electrons flowing from a negatively charged area to a positively charged.
Cathode Ray Oscilloscope (CRO)
PH THEORY What is it pH?What is it pH?/How is pH Measured?/What Equipment is Required to Measure pH?/How is a pH Measurement Device Calibrated?/Why is.
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 18, 19, 21.
A WIRELESS PASSIVE SENSOR FOR TEMPERATURE COMPENSATED REMOTE PH MONITORING IEEE SENSORS JOURNAL VOLUME 13, NO.6, JUNE 2013 WEN-TSAI SUNG, YAO-CHI HSU Ching-Hong.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Gold Nanostructure based Fiber Optic Sensor for Detection of Bacteria using Bacteriophages presented by Pallavi Halkare guided by Prof. Soumyo Mukherji.
Unit 11: Calibrating Instruments
UV/VIS SPECTROSCOPY.
Electrochemistry MAE-212
Potentiometry and potentiometric measurements
Biosensors Definition
ELECTRONIC TONGUE BY R.PAVAN KUMAR, RIPER-ANANTAPUR.
Ion Selective Electrode
Chapter 5: Analytic Techniques
Hemodialysis Lecture 3.
Sensors are mostly electrical or electronic.
FYS 4250 Kap.10 Chemical biosensors
Rapid Lab Systems measuring principle
Basic Electronics.
PH meter.
Chem. 133 – 2/9 Lecture.
Electrode Training HORIBA Instruments, Inc. Pamela Millett Scientific
Prepared by Dr. Mohamed Ahmed Awad
Chapter 23 Potentiometry.
Transducers Measurement/Information Processing System or
A. Capacitors B. Inductors C. Resistors D. Transistors
WELCOME.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Revolutionary Technology in pH Measurement Elicia Wong, PhD Mar 17-19, 2009

pH Control Wide Applications: Why is it Important in bioprocessing? Pharmaceutical/biotechnology (medicine) Cosmetic (perfume) Food and beverage (wine, sugar) Water purification & wastewater treatment Petroleum/deep sea/outer space exploration Why is it Important in bioprocessing? Critical quality parameter for cell and bacterial growth and metabolic activity, productivity and consistency. 2 L 80 L 400 L 2,000 L 10,000 L Upstream Process Downstream Process Why is it a problem in bioprocessing? Drifting Fouling Calibration

Outline Potentiometric pH measurement Glass electrode Existing pH measurement technologies Potentiometric pH measurement Glass electrode Ion-selective field effect transistor (ISFET) Optical pH measurement New technology Amperometric pH measurement

Potentiometric Approach – Glass electrode External reference electrode Measuring electrode High impedance pH meter Glass frit Glass membrane Inner solution Metal wire Glass frit Inner solution External reference electrode High impedance pH meter Glass membrane Glass electrode Voltage difference builds up on the sides of the glass membrane due to difference between H+ activities on both sides This voltage difference is measured with the help of an external reference electrode Often reference and measuring electrodes are combined in one single structure Fragile, wet storage, long term drift, requires frequent calibration

Ion-Selective Field Effect Transistor Vgs External reference electrode Analyte solution Solid state device Insulator Ion-selective interface Insulator Source Drain Electron path Vds Current flows Four major components: Source (s), Drain (d), Ion-selective interface and Gate (g). Hydrogen ions at or near the ion-selective interface will cause a variable voltage potential (Vgs – Vds) Cathode (-) No current flows Anode (+) H+ - - - - - +

Optical pH Measurement System Photo-detector Photodetector, optical fiber, sensor Sensor = fluorophore on solid support An incident beam of light is passed to the sensor, where it interacts with the fluorophore. The emitted light intensity is pH dependent Keep in dark (photo-bleaching) Sensor Optical light guide Incident beam Emitted light

Comparison Feature Glass Electrode ISFET Optical Robustness Glass (fragile) Solid state Calibration Required (frequently) Required (longer calibration interval) Required (factory+on site) Stability Drift Maintenance Intensive (wet storage) Easy (dry storage) Intensive (kept in dark (photo-bleaching) Temperature Range Wide Narrow pH range 0-14 5-9 (in ranges) Biological Fouling Occur Sensitivity  Low  Medium Good 

Amperometric pH Sensor Power supply Reference electrode Counter electrode V i Counter electrode Analyte solution pH-sensitive interface Internal reference pH-sensitive interface + Internal reference External reference electrode V V V V i i i i H+ H+ H+ H+ pH-sensitive interface semiconductor H+ H+ H+ H+ pH-sensitive interface semiconductor

Self-Calibrating Internal reference = pH insensitive molecule pH 10 pH sensitive molecules Internal reference

Stability Both the proprietary pH sensitive and insensitive molecules are chemically stable (won’t leach) and thermally stable (able to withstand high temperature up to 250 C). No degradation in performance with continuous operation and after heat sterilization. No degradation in signal with 2-day continuous operation after autoclaving Responses were observed after multiple autoclaving cycles (measurement performed after each autoclaving cycle) Continuous operation Multiple Autoclaving

Free from Biological Fouling pH detection relies purely on chemical interaction between hydrogen ion and sensing interface rather than membrane diffusion effect (glass electrode) - H+ Clotting of glass membrane H+ Continuous measurement in medium containing living cells pH sensitive molecules Detect change in pH from pH 7.82* to 7.01* Without pH control pH insensitive molecules *pH verified by off-line pH measurements

Ideal for bioprocess pH measurement Summary Chart Ideal for bioprocess pH measurement Feature Glass Electrode ISFET Optical Amperometric Sensor Robustness Glass (fragile) Solid state Calibration Required (frequently) Required (longer calibration interval) Required (factory) Self calibrated Stability Drift No drift Maintenance Intensive (wet storage) Easy (dry storage) Intensive (Kept in dark (photo-bleaching) Temperature Range Wide Narrow pH range 0-14 5-9 (in ranges) Biological Fouling Occur NO Sensitivity  Low Medium Good  Good