Sensor Operating Theory

Slides:



Advertisements
Similar presentations
Gas Detection Instruments
Advertisements

Monitoring Equipment and Detection Devices Chapter 14.
Mine Gases Atmospheric Testing C.4. Contributed by: Richard Black Industrial Scientific Corp.
OFFLINE COMPOSITION MEASURING SENSORS
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Teledyne Analytical Instruments
GAS ANALYSIS - Anaerobic sludge digestion & - Anaerobic treatment of high BOD containing wastes (~1500mg/L) Methane Formation.
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
MINE GASES n Category of Gases n Physics of Gases n Exposure Limits n Measurement of Gases n Mine Gases n Smoke & Damps.
… for Combustible Gas Detection S4000C Intelligent Sensors..
[Compact. Durable. Ingenious.]. Extra bright, highly visible LEDs Fits comfortably in the hand Separate Info display Extremely robust construction High.
© TDL Sensors Ltd 2012 Tunable Laser Gas Monitoring.
PART 75 SPAN & RANGE Manuel J Oliva Clean Air Markets Division
E VERY L IFE H AS A P URPOSE… Chemgard TM Infrared Gas Monitor.
5 GAS DIAGNOSTICS What Goes In Must Be Consumed, If Not It Comes Out! Steve Zack.
Environment Protection System INC.. GAS DETECTION SENSOR.
Hazmat Industry Technician. Types of Equipment Monitoring equipment Detection devices Air sampling systems.
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
Chemistry of Fire.
Chemical Hazards The overall objective for this module is that participants will extract and interpret chemical hazard information from a Material Safety.
1 Monitor of Isobutane Content in the RPC Gas Mixture Changguo Lu, Kirk McDonald Princeton University (10/22/2008)
PROPERTIES OF FLAMMABLE MATERIALS. Flammability Flammable Flammable –Capable of being ignited and of burning –Synonymous with combustible.
Mine Rescue Gas Detection
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
Fires and Explosions.
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
Applications: CO Gas Sensor
Methods of Measuring O 2.  Orsat - Oxygen absorption into a liquid results in a change in volume. Chemical, only. Indication, only, No electrical output.
ITX 4-Gas Detector Quick Reference Guide. Case:Type 304 Stainless Steel,.024" (.61mm) thick Dimensions:4.75" X 3.2" X 1.68" (121mm X 81mm X 43mm) Weight:18.5.
Ultima® X Series Gas Monitors
Laboratory Safety-Flammable Liquids Flammable Liquids and Fire Codes for Laboratories.
Combustible Gas & Oxygen Meter. Combustible gas indicators (CGIs) measure the concentration of a flammable vapor or gas in air, indicating the results.
HazMat Technician Mod 1 Unit 2 Slide 1 Ohio Hazmat & WMD Technician Module 1 Unit 2 Field Survey Instruments.
GAS DETECTOR BY : SELAMAT SURIYADI.
WELCOME TO Gas Tester Training O2, LEL Monitoring
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
Nanotechnology Metal Oxide Semiconductor (NTMOS) H2S Gas Sensor
Gas Leakage Detector System System Presentation By Kaihatsu Techno Centre Pvt. Ltd.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
SECTION 2 TERMINOLOGY. HAZARDOUS MATERIALS PROPERTIES.
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
MINE GASES. Normal Air is made up of: Nitrogen 78% Oxygen 21% Trace Gases 1%
H2S Gas Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting personal.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Lecture 22 Fuels. Reaction Rate. Electrolysis. Liquid, Solid, and Gaseous Fuels Reaction Rates Oxidation and Reduction Chapter 11.6 
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
Gas sensing Panca Mudji Rahardjo, ST.MT Electrical Engineering - UB.
THIN FILM GAS SENSORS Chemical sensors are important to all aspects of modern life. They Provide information about chemical substances needed by instruments.
1 LANDFILL GAS TRAINING. 2 INTRODUCTION  TYPE OF MONITORING -Screening -Specialized  GOALS.
TOWARDS A TEST METHOD FOR HYDROGEN SENSOR PERFORMANCE NATHAN D. MARSH AND THOMAS G. CLEARY Fire Research Division, National Institute of Standards and.
Infrared IR Sensor Circuit Diagram and Working Principle.
Hazards of Confined Spaces. INSTRUCTIONAL GOAL The participant till understand the various hazards associated with confined space entries and the need.
1Korea University of Technology and Education 2 Generation Common Rail VGT Variable Swirl 32Bit Computer Elec. Controlled EGR Flap C P F Electronically.
Gas Detection Systems Theory and Principles.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
Metal Nanoparticle Hydrogen Sensor
Introduction of Laser Evaluating Technology to Street Leak Surveys Ashraf Salha APA Group Gas Speak Colloquium September 2015.
Atmospheric Monitoring. ATMOSPHERIC MONITORING INSTRUCTIONAL GOAL The participant will understand the need for atmospheric monitoring and the types, uses,
Rev. 1 © Chevron 2009 Gas and Vapor Detection Awareness Plus.
Fire Loss Control - Basic Elements
CONFINED SPACE ENTRY TRAINING PROGRAM
Gas Detection in Water Treatment
THE LINEAR BARRIER SAFE EYE The gas linear detection
Sensors are mostly electrical or electronic.
Confined Space Hazards
Principles of Natural Gas
Gas Monitoring Basics Presented by Dan Klimek Sisk & Company.
Rayat Shikshan Sanstha’s S. M. Joshi College, Hadapsar
Presentation transcript:

Sensor Operating Theory Gas Detection Systems Sensor Operating Theory

Gas/Vapor Hazards- Flammable/Combustible Toxic Oxygen-deficiency Oxygen-enrichment

Gas Detection Objectives Measure gas before hazardous concentration is present Provide outputs for Emergency Action Suitable for extreme environments (arctic, tropic, etc) Complement to Flame Detection equipment Cost-effective protection

Gas Sensing Technologies Combustibles: Catalytic and Infrared Hydrogen Sulfide: Electrochemical & MOS Oxygen: Electrochemical Carbon Monoxide: Electrochemical Chlorine: Electrochemical Sulfur Dioxide: Electrochemical Nitrogen Dioxide: Electrochemical

Key Gas Detection Definitions Measurement range: gas concentration at full scale sensor output Unit of Measurement: %LEL, PPM, or %volume Flashpoint: minimum temperature of liquid where enough vapor is given off to sustain a fire or explosion Vapor Density: tendency of a pure gas of vapor to rise or sink in clean air Calibration: process of matching transmitter signal to sensor measurement

Combustible Gases-Lower & Upper Limits* *No differentiation between the terms “Explosive” and “Flammable” as applied to the lower and upper limits of flammability Too lean for ignition Too rich for ignition Clean Air Combustibles Lower Explosive Limit (LEL) Upper Limit (UEL) Typical Combustible Gas Detector Range of Measurement 50%

Flammable Limits & Volumetric Equivalents Methane Gas: 100% LEL= 5% by volume in air 75% = 3.75 “ 50% = 2.5% “ 25% = 1.25% “ 10% = .50% “

Catalytic Sensor Operation Contact-based Destructive measurement Traditional method Only option for hydrogen gas detection Used w/ transmitter module to provide 4-20 ma signal output Typical life of 3-6 years 2 year mfgr warranty

Catalytic Sensor Operation Active Element - Hot wire resistor coated with catalytic material Reference Element - Same as active but without catalyst Catalytic Oxidation of flammable gas generates heat & changes resistance of Active Element Explosion is prevented by Flame Arrestor Constant U or I power source required Must calibrate on start-up & routinely for accuracy Flammable gas

Catalytic Sensor Operation

Catalytic Sensor Limitations FAIL TO DANGER Poisoning of Catalyst Plugging of Flame Arrestor Read Low @ High Gas Levels Frequent Calibration Service Life - Variable (Months)

Infrared Combustible Detectors reference absorption band active absorption band Principal of Operation Gases are Transparent to Visible Light BUT... Gases are Strongly Opaque to Infrared Light at Some Wavelengths Methane Propane

Point Infrared Detector Principle of Operation Flammable hydrocarbon gas

Fail-Safe Operation

Open Path IR Gas Detector Instrumental Layout 10 - 60 m Flammable hydrocarbon gas Optical Beamsplitter Measurement Signal Detector IR Source Optical Filters Microprocessor and Electronics Reference Signal Detector Gas Concentration (LEL)

Drivers for Optical Technology Safety Driven Design Requirements FAIL SAFE No Unrevealed Sources of Failure HIGH AVAILABILITY Long Service Life Low and Easy Maintenance

Electrochemical Toxic Sensor Theory Specific to toxic gas type (H2S, CO, SO2, NO2, CL2 ) Consists of sensing(working), reference, and counter electrodes Vapor diffusion into capillary results in oxidation/ion reduction The signal (current) from the working electrode is converted to a voltage by operational amplifier Capillary Entrance O-ring Membrane Electrolytic fluid Sensing Electrode Reference Electrode Counter Electrode

Electrochemical Toxic Sensor Operation All provide 4-20 ma signal output 0-100 ppm range typical Carbon monoxide ranges: 0-100, 0-500, or 0-1000 ppm- must specify Nitrogen dioxide range: 0-20 ppm Hydrophobic filter provides humidity protection All designed to meet X-proof req. except CL2, SO2 sensors (I.S. barrier required) All designed for calibration by a transmitter, controller or external control system.

Traditional Sensor Calibration Matching transmitter output to raw sensor signal in clean air (zero) & mid-scale (span) conditions Manual or Automatic depending upon transmitter type Adjustments necessary if drifting has occurred Requires compressed, accurate calibration gases Always required @ start-up & after sensor replacement Every 30-90 days thereafter typical

Gas Detector Calibration Requirements Catalytic Sensors: Field Calibration required for accuracy DEC IR Detectors: Routine calibration not required; Factory calibrated for methane only Electrochemical Sensors: Field Calibration required for accuracy DEC Open Path IR System: Routine calibration not required; Factory calibrated for methane only