Ultrasonic Imaging Using Contrast Agents

Slides:



Advertisements
Similar presentations
Chapter3 Pulse-Echo Ultrasound Instrumentation
Advertisements

Foundations of Medical Ultrasonic Imaging
Doppler echocardiography & tissue doppler Dolly mathew.
Chapter 14 Sound.
Sound Chapter 15.
All sounds are produced by the vibration of matter. If there is no vibration, there is no sound.
Hospital Physics Group
Pegasus Lectures, Inc. Volume II Companion Presentation Frank Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
ECE 501 Introduction to BME
Ultrasonic Nonlinear Imaging- Tissue Harmonic Imaging.
Ultrasound Medical Imaging Imaging Science Fundamentals.
Ultrasound Imaging Atam Dhawan.
Versatile clinical applications.
Ultrasonic Nonlinear Imaging- Tissue Harmonic Imaging
Chapter 18 Superposition and Standing Waves. Waves vs. Particles Waves are very different from particles. Particles have zero size.Waves have a characteristic.
Ultrasound Physics Sound is a mechanical, longitudinal wave that travels in a straight line Sound requires a medium through which to travel Ultrasound.
Ultrasonography.
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
Principles of Medical Ultrasound
Ultrasonic Thermometry
Display of Motion & Doppler Ultrasound
Resident Categorical Course
1 Ultrasonic Elasticity Imaging. 2 Elasticity Imaging Image contrast is based on tissue elasticity (typically Young’s modulus or shear modulus).
Acoustics. Acoustics is the interdisciplinary science that deals with the study of all mechanical waves in gases, liquids, and solids including vibration,
Speckle Correlation Analysis1 Adaptive Imaging Preliminary: Speckle Correlation Analysis.
10/20/2015Copyright © 2008 Ballios, Dow, Vogtmann, Zofchak.
Display of Motion & Doppler Ultrasound
Review of Ultrasonic Imaging
Sarah Gillies Ultrasound Sarah Gillies
Introduction to the Physics Echocardiography Introduction to the Physics Echocardiography Jose L. Rivera, M.D. January 9, 2010.
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
Adaphed from Rappaport’s Chapter 5
Small Vessel Detection
Saudi Board of Radiology: Physics Refresher Course Kostas Chantziantoniou, MSc 2, DABR Head, Imaging Physics Section King Faisal Specialist Hospital &
Ultrasound Physics Reflections & Attenuation ‘97.
Ultrasonic Nonlinear Imaging- Contrast Imaging. History 1968 Gramiak et al published observation of echo signal from LV injection of indocyanine dye Subsequent.
Sound Waves Chapter 13. General Characteristics Longitudinal wave; requires elastic medium for propagation Series of compressions and rarefactions in.
Chapter 16 Waves-I Types of Waves 1.Mechanical waves. These waves have two central features: They are governed by Newton’s laws, and they can exist.
Chapter 16 Waves-I Types of Waves 1.Mechanical waves. These waves have two central features: They are governed by Newton’s laws, and they can exist.
A 5-Pulse Sequence for Harmonic and Sub-Harmonic Imaging
Laws of Thermodynamics Gibb’s Free Energy Applications of Ultrasound X-Ray imaging
Ultrasound Basis Michel Slama Amiens.
Artifacts Ultrasound Physics George David, M.S.
Performance Issues in Doppler Ultrasound 1. 2 Fundamental Tradeoffs In pulsed modes (PW and color), maximum velocity without aliasing is In pulsed modes,
Chapter 18 Oscillation, Wave and Sound. Oscillation equation Pendulum Wave equation.
Fundamental Ultrasound Principles Karen Potts Clinical Scientist Review date Jan 2010 Department of Medical Physics Kent & Canterbury.
TISSUE HARMONIC IMAGING (THI)
TISSUE HARMONIC IMAGING (THI)
Wave Action Theory for Turning of Intake & Exhaust Manifold
Physics 1 What is a wave? A wave is: an energy-transferring disturbance moves through a material medium or a vacuum.
TISSUE HARMONIC IMAGING NUR FASHIHA BINTI AZMAN A DIAGNOSTIC IMAGING AND RADIOTHRAPY /2.
NUR INANI BINTI MOHD RUZLAN A Tissue harmonic imaging is a technique in ultrasonography that provides images of better quality as compared to conventional.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Principles of Medical Ultrasound Zahra Kavehvash.
SOUND.
Doppler Spectral Analysis
Lecture on Ultrasonography
Sound in medicine Lect.10.
Reflections & Attenuation
Ultrasound.
Ultrasound.
Ultrasonic Testing.
Review of Ultrasonic Imaging
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Advanced Radar Systems
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Sound & Sound Waves.
All sounds are produced by the vibration of matter
Sound Waves and Ultrasound
Principles of Medical Ultrasound
Presentation transcript:

Ultrasonic Imaging Using Contrast Agents

Introduction Contrast agents are used to provide higher contrast. The three commonly seen contrast agents are backscatter, attenuation and sound velocity. Contrast agents could be solid particles, emulsion, gas bubbles, encapsulated gas, or liquid.

Introduction Primary clinical benefits: Enhanced contrast resolution between normal and diseased tissues. Outline of vessels or heart chambers. Tissue characterization by using tissue specific agents. Increasing blood flow signals. Dynamic study using washout curve.

Example

Clinical Applications: Cardiology Endocardial border detection. Left ventricle (LV) function. Valvular regurgitation quantification. LV flow patterns. Perfusion area of coronary artery. Assessment of surgery for ventricular septal defect.

Clinical Applications: Others Liver tumor enhancement. Uro-dynamics and kidney functions. Tubal function and placenta perfusion. Transcranial Doppler enhancement. LV pressure measurements.

Current Contrast Agents Echovist. Albunex. Levovist. Echogen. Quantison. Many more,…

Contrast Mechanisms Strong backscattering produced by air bubbles. The backscatter increases roughly linearly with the number of micro-bubbles. A bubble in liquid acts as a harmonic oscillator. Acoustic resonance provides the major echo enhancement. In addition, strong harmonics are produced.

Contrast Mechanisms Acoustic attenuation of soft tissues is typically represented by a constant (e.g., 0.5dB/cm/MHz). Since contrast agents significantly change the scattering properties, attenuation measurements can also be used for contrast enhancement.

Contrast Mechanisms Sound velocity is primarily determined by density and compressibility. Apparently, micro-bubble based contrast agents alter sound velocity. Contrast enhancement based on sound velocity variations is still academic.

Contrast Mechanisms Micro-bubbles produce strong harmonics when insonified near the resonance frequency. If such harmonics are stronger than tissue harmonics, contrast can be improved. Second harmonic signal is most useful due to limited transducer and system bandwidth.

Desired Characteristics of Contrast Agents Efficient backscattering. Small size for pulmonary transport. Long half-life. Low toxicity. Possibility of attenuation contrast. Possibility of speed of sound contrast.

Imaging Consideration Low peak acoustic amplitude. Low average acoustic power. ECG triggering. Frequency control.

System Requirements Transmitter: minimal harmonic signals. Propagation: minimal harmonic generation. Receiver: maximal fundamental rejection.

System Requirements Adequate dynamic range. Configurable beam former. Sufficient system bandwidth. Wide transducer bandwidth.

Imaging Techniques The phasing pattern across the array can be varied to reduce the signals at a certain frequency. Alternate phasing is applicable to contrast harmonic imaging. Alternate phasing on transmit is not ideal.

Imaging Techniques Alternate phasing for receive: p Alternate phasing for transmit 0.5p

Imaging Techniques Difference imaging technique: contrast agents can be viewed as a “modulator”. When two different frequencies, say f1 and f2, are used on transmit, the contrast agents generate f1+f2 and f1-f2. f1 and f2 can be properly chosen to increase the rejection ratio.

Imaging Techniques Subtraction mode: Two pulses with different signs are transmitted consecutively. By adding two images together, linear components cancel while second order components remain. This technique is susceptible to motion artifacts.

Pulse Inversion Doppler An extension for the subtraction mode to Doppler imaging, i.e., pulse inversion with multiple firings. There exists a nonlinear Doppler spectrum completely separate from the linear spectrum. Potential increase in agent to tissue contrast.

Problems in Flow Estimation Radiation force tends to move the contrast agents to a direction independent of the flow direction. Bubble break down causes image artifacts. Excessive backscatter produces “color blooming”. Spectral broadening at high acoustic pressures.