CAL crosstalk issues and their implications

Slides:



Advertisements
Similar presentations
Digital Filtering Performance in the ATLAS Level-1 Calorimeter Trigger David Hadley on behalf of the ATLAS Collaboration.
Advertisements

LI Gain Curves Peter Litchfield Calibration Workshop, 6 th September 2005  Beginning to understand the LI system  Beginning to understand the software.
GLAST LAT Project Calibration & Analysis Meeting - August 29, 2005 Benoît Lott Gamma-ray Large Area Space Telescope Response of the GLAST LAT Calorimeter.
GLAST LAT ProjectIA Workshop 6 – Feb28,2006 Preliminary Studies on the dependence of Arrival Time distributions in the LAT using CAL Low Energy Trigger.
Checking the Acd hardware veto setting The hardware veto is generated in the front-end electronics Discriminator with coarse and fine settings Both are.
CMS Physics Meeting, Dec. 6, Analysis Note on the Validation of the ORCA Simulation of the Endcap Muon CSC Front-end Electronics S. Durkin -- Ohio.
A.Chekhtman1 GLAST LAT ProjectCalibration and Analysis group meeting, April, 3, 2006 CAL on-orbit calibration with protons. Alexandre Chekhtman NRL/GMU.
GLAST LAT Project Instrument Analysis Workshop 5 – 05/08/29 F. Piron & E. Nuss (IN2P3/LPTA – Montpellier) 1 Comprehensive review of CAL calibrations Gamma-ray.
A.Chekhtman1 GLAST LAT ProjectInstrument Analysis meeting, July 28, 2006 Calibration of high energy diode. Alexandre Chekhtman NRL/GMU Gamma-ray Large.
A.Chekhtman1 GLAST LAT ProjectInstrument Analysis meeting, June, 24, 2005 CAL retriggering study with SLAC data. Alexandre Chekhtman NRL/GMU Gamma-ray.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
A.Chekhtman1 GLAST LAT ProjectInstrument Analysis meeting, January, 20, 2006 Status of calorimeter calibration. Alexandre Chekhtman NRL/GMU Gamma-ray Large.
A.Chekhtman1 GLAST LAT ProjectCAL Recon rewriting meeting, May, 11, 2005 In what cases we need external position estimation ? Alexandre Chekhtman NRL/GMU.
ACD calibrations Pedestals Measured from online script Measure PHA w/ HV off, no charge injection Use cyclic triggers ~ ADC counts, very narrow.
ECAL electronics Guido Haefeli, Lausanne PEBS meeting 10.Jan
Electronic Devices Ninth Edition Floyd Chapter 13.
Performance of SPIROC chips in SKIROC mode
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
Cube Measurements Tent Crew. Scintillation BNL 241 Am Semi- collimated  Spectralon Diffuse UV Reflector SBD  -Trigger Scint. Light Poisson.

A.Chekhtman1 GLAST LAT ProjectBeam test meeting, September 27, 2006 CsI afterglow - possible explaination of pedestal drift and excess of energy. Alexandre.
GLAST LAT Project Instrument Analysis Meeting August 6, 2004 David Smith w. Benoît Lott Muons in photodiodes1 MIPs in your Photodiodes David’s Instr. Ana.
Dec.11, 2008 ECL parallel session, Super B1 Results of the run with the new electronics A.Kuzmin, Yu.Usov, V.Shebalin, B.Shwartz 1.New electronics configuration.
1 G.Pessina, RICH Elec Upg, 11 April 2010 Analog Channels per chip4 to 8 Digital channel per chip4 to 8 Wire-bond pitch (input channels) Input capacitance.
A.Chekhtman1 GLAST LAT ProjectInstrument Analysis meeting, February, 27, 2006 CAL features and idiosyncrasies. Alexandre Chekhtman NRL/GMU Gamma-ray Large.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Feb. 7, 2007First GLAST symposium1 Measuring the PSF and the energy resolution with the GLAST-LAT Calibration Unit Ph. Bruel on behalf of the beam test.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
Feature Extractor Dima Chirkin, LBNL The future is here.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Digitization in EMC simulation Dmytro Melnychuk, Soltan Institute for Nuclear Studies, Warsaw, Poland.
1 GLAST LAT Project CalSoft Face-to-Face Meeting April 15 – 16, 2004 Benoît Lott GSI Analysis Status Degrader 58 Ni Beam Fragments Target EM miniCAL GSI’s.
SCT WeekDecember 3, Block of Low Gain Analysis and Solutions A. Ciocio - LBNL.
SRS Calibration Michael Phipps, Bob Azmoun, Craig Woody 1.
GLAST LAT ProjectI&T Test Planning Telecon, 8 Nov 2004 CAL Test and Calibration DefinitionJ. Eric Grove GLAST LAT GLAST LAT Calorimeter Subsystem Gamma-ray.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
Feb. 3, 2007IFC meeting1 Beam test report Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope.
SRS Calibration Part II: Dynamic Range, Signal/Noise, Pulse Shape and Timing Jitter + initial results from scan of FIT zigzag board Michael Phipps, Bob.
M.D. Nov 27th 2002M0' workshop1 M0’ linearity study  Contents : Electronic injection Laser injection Beam injection Conclusion.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
FUNCTION GENERATOR.
IC Design Research Laboratory 1 Design StatusMay 2014 Custom Chip For Use With Silicon Strip Detectors IC Design Research Laboratory Department of Electrical.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
 13 Readout Electronics A First Look 28-Jan-2004.
GLAST LAT Project SE Test Planning Dec 7, 2004 E. do Couto e Silva 1/27 Trigger and SVAC Tests During LAT integration Su Dong, Eduardo do Couto e Silva.
Transient Waveform Recording Utilizing TARGET7 ASIC
Fabio, Francesco, Francesco and Nicola INFN and University Bari
P.Astone, S.D’Antonio, S.Frasca, C.Palomba
Electronic Devices Ninth Edition Floyd Chapter 13.
EZDC spectra reconstruction and calibration
Analysis of FADC single-crystal data
Pulse Shape Fitting Beam Test September, October CERN
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
A First Look J. Pilcher 12-Mar-2004
CMS ECAL Calibration and Test Beam Results
Electronic Control Systems Week 4 – Signaling and Calibration
Gamma-ray Large Area Space Telescope
Status of n-XYTER read-out chain at GSI
BESIII EMC electronics
Calorimeter calibrations with Flight Software.
Imaging crystals with TKR
6.1 Introduction to Chi-Square Space
Uses of filters To remove unwanted components in a signal
Eduardo do Couto e Silva Feb 28, 2006
Shaped Digital Readout Noise in CAL
Gain measurements of Chromium GEM foils
Presentation transcript:

CAL crosstalk issues and their implications Gamma-ray Large Area Space Telescope CAL crosstalk issues and their implications Alexandre Chekhtman NRL/GMU

How we can study signal pulse shape ? Shp_p01 test measures the CAL response to the same injected charge, but setting different “tack” (trigger acknowledgement) delay Plot shows the result of pulse shape measurement for the following conditions: the signal amplitude close to the muon signal “Fast shaper Low Energy” (FLE) discriminator threshold set to maximum possible value FLE=127 – discriminator never fired.

What happens for nominal FLE threshold ? Pulse shape for lower FLE threshold (red curve) superimposed on normal pulse shape Fired FLE discriminator produces significant distortion of the pulse shape

FLE crosstalk shape Amplitude of this effect is rather big ~100 adc units (4MeV) Fortunately, we are making energy measurement at tack=5µs, where effect is small If FLE is fired asynchronously by noise or other scintillation, the crosstalk could introduce significant positive or negative bias Could result in pedestal bias and/or broadening By subtracting normal curve from distorted curve we can find the shape of crosstalk

Example of charge injection curves Difference between curves explained by crosstalk from fast shaper discriminator to the input of LEX8 preamplifier Charge injection should be done with exactly the same settings as real data we want to correct for non-linearity Points (triangles, squares) – charge injection calibration data Curves – spline fit Red curve+squares: highest possible fast shaper discriminator threshold - above lex8 range Blue curve+triangles: fast shaper discriminator threshold used for muon data collection

FLE thresholds for muons and charge injection Thresholds are measured using diagnostic bit for FLE discriminator Thersholds for muons are ~2 times higher than for charge injection due to longer rise time of scintillation pulse

FLE thersholds ratio muons to charge injection FLE discrimiator thersholds are different for muons and charge injection we cannot directly apply to muons the nonlinearity correction, measured by charge injection, because it contains a component sensitive to FLE threshold position We have to extract this crosstalk component, scale it according to muon/charge injection threshold ratio and add back to non-linearity correction. Correction procedure is rather complex, we need some direct measurement of FLE crosstalk effect for muons to verify the procedure

FLE crosstalk for muons It is possible to see FLE crosstalk for muons by looking at correlation of signals from LE and HE diodes (LEX8 and HEX8 ranges) when we use “muon gain” setting for HE diode, allowing to see muons signal HE diode is not affected by this crosstalk because corresponding discriminator (FHE) set to 127 and is not fired We have to correct both signals (LEX8 and HEX8) for other nonlinearities, not related to FLE crosstalk and measured when FLE=127 To calibrate nonlinearity of HEX8 range for small signals with muon gain we used special charge injection setting, decreasing injected charge by factor of 10 (using smaller capacitor).

Nonlinearity correction for small signals Nonlineraity of LEX8 and HEX ranges was measured with FLE=127 and special setting providing small charge injection steps Results of the measurement were fitted with exponential functions and appropriate correction applied to muon signals

FLE crosstalk for muons - result Crosstalk for muons calculated as xtalk = lex8-k*hex8, where k is defined by hex8/lex8 gain ratio (for selected crystal=2 side=0 layer=5 this coefficient is k=4.68) Comparison with charge injection crosstalk (blue circles) confirms that the amplitude of the crosstalk is the same along horizontal axis the curve is scaled according to FLE threshold which bigger for muons than for charge injection

Muons collected with external trigger If external trigger (tracker or plastic scintillators) used for triggering and FLE thresholds set high to avoid firing of FLE discriminators, the FLE crosstalk effect should be absent It is possible to verify it the same way as described above, but more statistics needed (now – only one run ~200K triggers) I checked that muon peaks positions for nominal FLE thresholds for muon collection are higher by ~5-10 adc units than for muons collected with external trigger and FLE=127. This also confirms the presence of FLE crosstalk

Conclusions The crosstalk from fast shaper discriminator to slow shaper output produce nonlinearity The effect depends on tack delay, gain and FLE threshold settings For currently recommended gain=5, fle=“2MeV” the effect is ~10 adc units muon peak is ~350 adc units =>the effect is ~0.3 MeV => 3% bias in muon calibration In some situations the crosstalk could produce much bigger error in energy measurement (~3MeV) - coincidence with noise or other particle. Due to the fact that thresholds for muons are ~2 times higher than for charge injection signals, the non-linearity function, measured with charge injection, should be scaled. Crosstalk effect for muons has be measured directly by using small diode (HEX8 range) as a reference

Backup slides

Nonlinearity from FLE discriminator crosstalk FLE (fast shaper low energy) discriminator receives signal from fast shaper and produces digital signal used by trigger. FLE discriminator threshold is defined by FLE_DAC Comparing the pulse shape at slow shaper for different FLE_DAC settings with pulse shape measured with high FLE threshold (FLE_DAC=127) one can see the effect of crosstalk from the fast shaper The same effect is seen in charge injection calibration as a positive step ~20 adc units (~1 MeV) when fast shaper reaches the threshold of discriminator.

Effect of FLE/FHE thresholds With thresholds FLE=100 MeV and FHE=1GeV used in GSI the effect on linearity becomes much smaller than with “muon” thresholds