Water Quality-Based Effluent Limits

Slides:



Advertisements
Similar presentations
What are TMDLs? and What Might They Mean to MS4 Permittees?
Advertisements

Jennie Henthorn Henthorn Environmental Services LLC.
1 Mixing Zones, Reasonable Potential Analysis, and Permit Limits A Quick Overview Steve Schnurbusch Oregon Department of Environmental Quality
The WQCD Permitting Perspective Janet Kieler Permits Section Manager.
Approach for Including Nutrient Limitations within NDPDES Permits Dallas Grossman Division of Water Quality
WWTF’s MPCA Permit Renewal January 14,  Our current NPDES permit expired Sept. 30,  NPDES permits are a 5 year term.  Upon expiration,
Water Quality Standards and MS4 Storm Water Permitting.
FE Review for Environmental Engineering Problems, problems, problems Presented by L.R. Chevalier, Ph.D., P.E. Department of Civil and Environmental Engineering.
Critical Conditions Review
An Introduction To The Use Of Modeling of Surface Waters For TPDES Permits Mark A. Rudolph, P.E. WQ Modeler, TCEQ WQ Division.
WQBELs Karen Holligan May 6, WQBELs – A Four-Piece Puzzle Numerical criteria (toxic pollutants) Water body quality Effluent fraction Bioavailable.
U.S. Department of the Interior U.S. Geological Survey Evaluations of Heavy Metal Listings on the State of Massachusetts Integrated List of Waters Assabet.
Impaired and TMDL Waterbody Listings Impacts on DoD Facilities Bill Melville, Regional TMDL Coordinator
Georgia Tech What is Dilution?? Ocean Plan (2001) p. 15: INITIAL DILUTION is the process which results in the rapid and irreversible turbulent mixing of.
Rules Overview: Why Do We Do What We Do Alisa Max, P.E. Harris County Alisa Max, P.E. Harris County.
Overview of WQ Standards Rule & WQ Assessment 303(d) LIst 1 Susan Braley Water Quality Program
Jericho Aquatic Discharge Assessment Presented by: Bruce Ott, Senior Environmental Scientist, AMEC Earth & Environmental.
1 IDEM Overview of March 14, 2008 Draft Antidegradation Rule Presented at the April 29, 2008 Antidegradation Stakeholder Meeting.
Surface Water Standards Triennial Review and Implementation Connie Brower Nikki Remington-Julie Grzyb-Sandra Moore NC Division of Water Quality.
Implementation Procedures (IPs) Brittany Lee Standards Implementation Team
Eric Agnew Environmental Regulations February 15, 2006.
Report of the NPDES Subcommittee. Conference Call Meetings July 8 and August 19 Mercury Discharges – Utility Request to Address Permit Requirements for.
Procedures to Implement the Texas Surface Water Quality Standards
“No instrument has yet been devised that can measure toxicity! Chemical concentrations can be measured with an instrument but only living material can.
Critical Conditions Review Jeff Borski │ Water Quality Assessment Team.
An Introduction To Modeling of Surface Waters For TPDES Permits Mark A. Rudolph, P.E. TCEQ Water Quality Division.
Ch. 1: “Watersheds and Wetlands” Lesson 1.5: “Factors That Affect Wetlands and Watersheds” Part 2.
Potential Changes to Sections and 307.9: Standards Applicability and Attainment Gregg Easley TCEQ Water Quality Standards Team September 6, 2007.
Changes to § Application of Standards and §307.9-Determination of Standards Attainment Gregg Easley Water Quality Standards Team Texas Commission.
Texas Surface Water Quality Standards Update Joe Martin Water Quality Standards Work Leader Joe Martin Water Quality Standards Work Leader.
30 TAC Chapter 307 Texas Surface Water Quality Standards Workgroup meeting March 7, 2007.
Selenium Aquatic Life Criteria and Implementation ORSANCO Technical Committee Meeting October 21, 2009 Holly Green, USEPA Office of Science and Technology.
PUBLIC HEARING September 15, Draft NPDES Permits for ArcelorMittal Facilities Indiana Harbor West, Central Wastewater Treatment Plant, Indiana.
Connie Brower NC DENR Division of Water Resources.
WQBELs Karen Holligan September 23, WQBELs – A Four-Piece Puzzle Numerical criteria (toxic pollutants) Water body quality Effluent fraction Bioavailable.
Activities Review for the Water Unit Test.
Revisions to: The Procedures to Implement the Surface Water Quality Standards Mrs. Brittany M. Lee Standards Implementation Team Phone:
Solution Concentration.  Lesson Objectives  Describe the concept of concentration as it applies to solutions, and explain how concentration can be increased.
Lynas Advanced Materials Plant
Selenium: The Curse of the West
Water Quality-Based Effluent Limits
Module 17: MIXING ZONES A limited area or volume of water where initial dilution of a discharge takes place and where numeric water quality criteria.
Cara Cowan Watts Graduate Student Biosystems Engineering
Trakya University Department of Biology EDIRNE TURKEY
Critical Conditions Review
Total Maximum Daily Load Program
Clark Fork River Metals TMDL Development
Chapter 11 – Measuring Solubility
Introduction If nontoxic organic pollutants get discharged into a river, lake or stream, they should be pretty harmless, right?
Public Meeting February 19, 2009
Chapter 4.5 – Aquatic Ecosystems
Des Plaines River Watershed Workgroup Midwest Biodiversity Institute
Warmup 10/22/12 As the population of Durham increases…
Water Biomes.
Report of Proceedings Surface Water Quality Standards Triennial Review Environmental Management Commission November 13, 2014 Steve Tedder – EMC Hearing.
Monitoring keeps track of something for a specific purpose.
303(d) List March 9, 2016 WQC Jeff Manning, DWR
Spencer Bohaboy Policy Development Specialist Water Quality Policy
Pearce Creek DMCF Baseline Exterior Monitoring Spring 2017 Results
Aquatic Biomes.
Passaic Trading Formula
2018 Texas Surface Water Quality Standards Revision
` Permitting Workshop Water Quality Control Division cdphe.state.co.us/wq Pueblo, Colorado May 18, 2005.
Water Quality-Based Effluent Limits
Update on Whole Effluent Toxicity (WET)
Diversity Indices and Standards
Incorporating metal bioavailability into permitting – UK experience
Water Quality What is water quality?
EPA’S ROLE IN APPROVING BASIN PLAN AMENDMENTS
Procedures to Implement the Texas Surface Water Quality Standards
Presentation transcript:

Water Quality-Based Effluent Limits (WQBELs) Hi, my name is Erika Crespo. I am an industrial wastewater permit writer with the Water Quality Division of the TCEQ, and I am going to talk about how water quality-based effluent limits are calculated. Erika Crespo May 2017

Permit limits apply to discharges Permit limits apply to discharges. Water quality criteria apply to water bodies. In other words, criteria in the Texas Surface Water Quality Standards do not apply directly to a discharge. The TCEQ is responsible for maintaining and enhancing water quality in the state. The Texas Surface Water Quality Standards are the legal standards for the quality of surface water in Texas. The water quality criteria in the Texas Surface Water Quality Standards apply to WATERBODIES and do not directly apply to a wastewater discharge.

What factors influence water quality-based permit limits? Numerical criteria (toxic pollutants) Water body quality Effluent fraction (mixing) Bioavailable fraction When it comes to calculating water quality-based effluent limits, the process is much like putting a puzzle together, and there are four main puzzle pieces: - the numerical criteria for toxic pollutants = purple - the water quality in the receiving water body = blue - the effluent fraction associated with mixing = green - the bioavailable fraction associated with aquatic life = red Throughout the presentation, I will refer back to these associated puzzle pieces and colors. This topic is pretty complex, so I help that this visual aid helps in understanding it.

Texas has numerical criteria for aquatic life and human health protection. ◊ Found in Texas Surface Water Quality Standards (30 TAC Chapter 307 Section 6 – Toxic Materials) The first puzzle piece that we will be discussing today is the purple one, which represents NUMERICAL CRITERIA for toxic pollutants. The state of Texas has established numerical criteria for toxic pollutants so that aquatic life and human health are protected.

Numerical criteria for toxic materials can change over time. ◊ Criteria revisited every three years Pollutant 2010 Criteria 2014 Criteria % Change Aldrin Freshwater, acute 3.0 μg/L No change Hexachloroethane Human health, water & fish 27 μg/L 4.97 μg/L -82 % Benzo(a)anthracene Human health, fish only 0.33 μg/L 3.28 μg/L 994 % Numerical criteria is revisited every three years. The table in this slide shows that during our most recent revision, the criterion for Aldrin stayed the same, while the criterion for Hexachloroethane became more stringent, and the criterion for Benzo(a)anthracene became more relaxed.

Numerical criteria for aquatic life reflect an organism’s environment and exposure. Table 1. Criteria in Water for Specific Toxic Materials Aquatic Life Protection Let’s discuss the numerical criteria for aquatic life. Table 1 in the Texas Surface Water Quality Standards is divided up based on freshwater or saltwater environments and based on acute or chronic exposure. When it comes to ACUTE toxicity, we are dealing with exposures of ≤ 4 days. (Acute toxicity deals with lethality – things will die.) When it comes to CHRONIC toxicity, we are dealing with exposures of ≥ 7 days. (Chronic toxicity deals with growth and reproduction – life survives, but do they thrive?)

Not all of the numerical criteria are expressed in the same way. ◊ Most criteria are for total concentrations. ◊ Some metals criteria are for dissolved concentrations: • aluminum • arsenic • cadmium • chromium (tri and hex) • copper • lead • nickel • silver (free ion) • zinc But wait! Permit limits are written for total concentrations. While most criteria are total concentrations, all of the metals listed on this slide have criteria for the dissolved portion in water. This is interesting because the limits that are placed in to permits are for total concentrations, not dissolved concentrations. So your may be wondering how do we derive our limits? Well, it requires that we incorporate some of those other four puzzle pieces.

𝑪𝒅 𝑪𝑻 = 1 1+(𝐾𝑝 × 𝑻𝑺𝑺 × 10−6) 𝐾𝑝=10𝑏 × 𝑻𝑺𝑺 𝑚 Metals criteria may be expressed as a dissolved concentration because local water quality affects toxicity. ◊ Conversion from dissolved criteria to total limits uses ambient total suspended solids (TSS) of the nearest downstream classified segment. ◊ Hint: Dissolved fraction = bioavailable fraction. 𝑪𝒅 𝑪𝑻 = 1 1+(𝐾𝑝 × 𝑻𝑺𝑺 × 10−6) 𝐾𝑝=10𝑏 × 𝑻𝑺𝑺 𝑚 There is a definable ratio between the total concentration of a metal and how much of it is dissolved. That ratio can be calculated and measured using the ambient total suspended solids concentration of the receiving water body. The dissolved concentration of a metal is also known as the bioavailable fraction. Having a high concentration of dissolved metals can be harmful to the environment and human health, and this is indicated through toxicity. We will discuss this more later on, but we are starting to see how the different puzzle pieces are connected and build on each other.

Criteria for pentachlorophenol are affected by pH. 𝐴𝑐𝑢𝑡𝑒 𝑐𝑟𝑖𝑡𝑒𝑟𝑖𝑜𝑛= 𝑒 (1.005 𝒑𝑯 −4.869) 𝐶ℎ𝑟𝑜𝑛𝑖𝑐 𝑐𝑟𝑖𝑡𝑒𝑟𝑖𝑜𝑛= 𝑒 (1.005 𝒑𝑯 −5.134) ◊ Pentachlorophenol is more toxic at lower pH values. Pentachlorophenol provides a good example of how water quality affects numerical criteria. The toxicity of pentachlorophenol is affected by pH. And pentachlorophenol is more toxic in water that has a low pH (or water that is more acidic). Therefore, permit limits for pentachlorophenol are more stringent for facilities whose receiving waters have low pH. For pH of 3: For pH of 6: Acute criterion = 0.157 Acute criterion = 3.19 Chronic criterion = 0.120 Chronic criterion = 2.45

Some freshwater criteria depend on the hardness of the receiving water. ◊ These include: • cadmium • chromium (trivalent) • copper • lead • nickel • zinc Another example of water body quality impacting numerical criteria can be seen in case of total hardness. In general, most metals are more toxic in water that has low hardness values (soft water). Therefore, water quality criteria are more stringent for receiving waters that have low hardness values. Copper is an example of a toxic metal that is affected by hardness. Example: copper 𝐴𝑐𝑢𝑡𝑒 𝑐𝑟𝑖𝑡𝑒𝑟𝑖𝑜𝑛= 0.960𝑚𝑒 (0.9422 ln ℎ𝑎𝑟𝑑𝑛𝑒𝑠𝑠 −1.6448) 𝐶ℎ𝑟𝑜𝑛𝑖𝑐 𝑐𝑟𝑖𝑡𝑒𝑟𝑖𝑜𝑛= 0.960𝑚𝑒 (0.8545 ln ℎ𝑎𝑟𝑑𝑛𝑒𝑠𝑠 −1.6463)

Acute Criterion (µg/L) Chronic Criterion (µg/L) Metals affected by hardness are more toxic in soft water. ◊ Freshwater criteria are lower at smaller hardness values. Example: copper Segment Number Water Body Name Hardness (mg/L of CaCO3) Acute Criterion (µg/L) Chronic Criterion (µg/L) 0505 Sabine River Above Toledo Bend Reservoir 42 6.27 4.51 1412 Colorado River Below Lake J. B. Thomas 310 41.2 24.8 Again, looking at Copper, which is an example of a metal that is affected by hardness. Copper is more toxic in receiving waters that have low hardness values. Let’s compare Segment No. 0505 to Segment No. 1412… 0505: Lower hardness value leads to Higher toxicity which results in Lower criteria values 1412: Higher hardness value lead to Lower toxicity which results in Higher criteria values

Water Body Quality Critical values for water quality parameters for each classified segment are found in Procedures to Implement the Texas Surface Water Quality Standards (IPs), June 2010, Appendix D. ◊ Total suspended solids (TSS) ◊ pH ◊ Total hardness ◊ Total dissolved solids (TDS) ◊ Chloride ◊ Sulfate Now let’s discuss the water body quality puzzle piece in more detail The Procedures to Implement the Texas Surface Water Quality Standards, or what we refer to as the IPs, explain the procedures that the TCEQ uses when applying the Texas Surface Water Quality Standards to permits that are issued under the TPDES (Texas Pollution Discharge Elimination System) program. Critical values for water quality parameters can be found in Appendix D, and these ambient values are considered to be critical conditions.

Effluent fractions help convert numerical criteria into limits. Numerical criteria apply at the edge of each zone: So now that we have discussed how the local water quality provides us with critical conditions, let’s discuss how the other puzzle pieces are used to derive effluent limits. In particular, let’s discuss the use of effluent fractions. An effluent fraction is the amount of wastewater relative to the amount of receiving water. And effluent fractions are important for converting numerical criteria into actual permit limits. There are three zones associated with wastewater discharges: – Zone of Initial Dilution – Aquatic Life Mixing Zone – Human Health Mixing Zone Numerical criteria apply at the edge of each zone: – Acute Aquatic Life criteria – apply at the edge of the Zone of Initial Dilution (ZID) – Chronic Aquatic Life criteria – apply at the edge of the Aquatic Life Mixing Zone (MZ) – Human Health criteria – apply at the edge of the Human Health Mixing Zone (HHMZ) (The distances from the point of discharges depend on the type of receiving water body that the discharge is going into…. Diagram in slide is of a wide tidal river)

Texas assumes critical low flow or low mixing conditions. Expressed as: ◊ Critical effluent percentages (lakes, bays, estuaries, wide tidal rivers) or ◊ Critical flows (streams, rivers, narrow tidal rivers) Our permits are written to account for critical low flow conditions or critical low mixing conditions. The critical-condition concept asserts that if a discharge is controlled so that it does not cause water quality criteria to be exceeded in the receiving water during critical flow conditions, then the discharge will likely be protective of those same water quality criteria at all flows. Critical effluent percentages or critical flows are assigned depending on the type of receiving water body.

Bioavailable Fraction The bioavailable fraction equals: where: Cd = dissolved concentration CT = total concentration This fraction depends on TSS : 𝐶 𝑑 𝐶 𝑇 The bioavailable fraction is the portion of the pollutant that is available to organisms for use, and it is equal to the dissolved concentration divided by the total concentration. It depends on the ambient total suspended solids concentration of the receiving water body. 𝐶 𝑑 𝐶 𝑇 = 1 1+( 𝐾 𝑝 ×𝑇𝑆𝑆 × 10 −6 )

Bioavailable Fraction 𝐶 𝑑 𝐶 𝑇 = 1 1+( 𝐾 𝑝 ×𝑇𝑆𝑆 × 10 −6 ) The term KP, the partition coefficient, also depends on TSS: where “b” and “m” are values found in Table 6 in the 2010 IP (p. 160). 𝐾 𝑝 = 10 𝑏 × 𝑇𝑆𝑆 𝑚 Because effluent limits are expressed as total concentrations, TCEQ staff has to use partition coefficients in order to determine instream compliance with the numerical standards for dissolved concentrations. The use of partition coefficients determines how much metal is dissolved in the receiving water.

Putting All the Pieces Together Water Body Quality Numerical Criteria SO NOW LET’S PUT ALL OF THE PIECES TOGETHER… Effluent Fraction Bioavailable Fraction

Putting All the Pieces Together Four easy steps to calculate WQBELs for aquatic life and human health! ◊ Calculate waste load allocation – WLA ◊ Calculate long-term average – LTA ◊ Calculate effluent limits: • daily average (DLY AVG) • daily maximum (DLY MAX) ◊ Final permit limits are determined by comparison There are FOUR steps in calculating water quality-based effluent limits for both aquatic life and human health: The waste load allocations are calculated The long-term average concentrations are calculated using WLAs The daily average and daily maximum effluent limits are calculated using LTAs Final permit limits are determined after comparing the effluent limits calculated for aquatic life with the effluent limits calculated for human health

Call your permit writer! Help! My draft permit includes a new or more stringent WQBEL – what can I do? Call your permit writer! Now, what happens if you receive a draft permit with a new or more stringent water quality-based effluent limit included? What should you do?? YOU SHOULD CALL YOUR PERMIT WRITER

Water Quality-Based Effluent Limits QUESTIONS Water Quality-Based Effluent Limits Are there any questions??? Erika Crespo May 2017