Hybrid MS instruments including TOF analyzers

Slides:



Advertisements
Similar presentations
Performance of a Hybrid RF/DC Quadrupole-Linear Ion Trap Mass Spectrometer James W. Hager MDS SCIEX ASMS, 2002.
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Sanja Risticevic Chem 323 Poster Presentation Quadrupole Ion Trap Mass Spectrometry.
CONTROL OF ELECTRON ENERGY DISTRIBUTIONS IN INDUCTIVELY COUPLED PLASMAS USING TANDEM SOURCES* Michael D. Logue (a), Mark J. Kushner (a), Weiye Zhu (b),
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
AAS and FES (Ch 9, 7th e, WMDS)
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Introduction to MALDI-TOF MS
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Lecture 8. GC/MS.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Mass Spectrometry.
Molecular Mass Spectrometry
LC-MS Lecture 7.
MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin.
AUSTEN K. SCRUGGS CALIFORNIA STATE UNIVERSITY, FRESNO RIMI FACILITY INSTRUMENTATION.
TOF Mass Spectrometer &
Atomic Emission Spectroscopy
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
INF380 - Proteomics-61 INF380 – Proteomics Chapter 6 – Mass Spectrometry – MALDI TOF The MALDI-TOF instruments are the simplest MS instruments suitable.
Based on ionization of gas phase molecule followed by analysis of the masses of the ions produced. The Mass Spectrum: Graph of ion intensity versus mass-to-charge.
Mass Analyzers IV Quadrupole Ion Traps Chem 5181 – Fall 2007 J. Kimmel.
Marvin Vestal and Kevin Hayden SimulTOF Systems
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Atmospheric Pressure Ionization - Time of flight mass spectrometry (API-TOF/MS) API-TOF/MS is the integration of two instrumental techniques, API and TOF/MS.
Mass Analyzers : Time-of-flight Mass Spectrometry CU- Boulder CHEM 5181 Mass Spectrometry & Chromatography Joel Kimmel Fall 2007.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
Mass Spectrometry Quantitative Mass Spectrometry
Sequential Bond Dissociation Energies of Fe + (CO 2 ) n (n = 1-5) Meghan MacKenna*, Hideya Koizumi, and P.B. Armentrout Department of Chemistry, University.
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
What is Mass Spectrometry? Mass spectrometry could be considered as an analytical technique that involves the study in the gas phase of ionized molecules.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Peptide Mass Finger-Printing Part II. MALDI-TOF
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
Components of Mass Spectrometer
MoP-067 Michael Sudakov 1, R.Giles1 and Dimitris Papanastasiou2
Visit for more Learning Resources
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Chem. 133 – 4/13 Lecture.
Mass Spectrometry 101 Hackert - CH 370 / 387D
For Forensic Toxicology use Only
Tandem MS.
Time of Flight Analyzers
LC-MS Lectures Dr Mike Kinsella.
Mass Spectrometry Obaid M. Shaikh.
What is MSMS? MS/MS means using two mass analyzers (combined in one instrument) to select an analyte (ion) from a mixture, then generate fragments from.
ROSINA, COSAC & PTOLEMY Reviewer: Heather Franz 2/15/16 – 2/17/16
PANDA Collaboration Meeting
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Concepts in Mass Spectrometry
Instrumental Chemistry
Time-of-Flight Mass Analyzers
Schematic of the principles of mass spectrometry (MS).
Sample Spectra 1/1/2019.
10.6 Fourier Transform Mass Spectrometry
Molecular Mass Spectroscopy
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Dr. Ramón González-Méndez MRSC
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Inductively Coupled Plasma
Presentation transcript:

Hybrid MS instruments including TOF analyzers Due to their high transmission range, resolution and accuracy, TOF analyzers have been implemented, in conjunction with a different mass analyzer, in a number of hybrid mass spectrometers, usually having MS/MS or MSn capabilities. The most common couplings are: Quadrupole Ion Trap – TOF (QIT-TOF) Quadrupole – TOF (Q-TOF) Both MALDI and ESI/APCI (API) have been used as ionization sources for these hybrid spectrometers.

MALDI-QIT-TOF hybrid MS In this system the ion beam resulting from the MALDI process is directed to a quadupole ion trap and accumulated. Decoupling of the ionization process from the mass measurement is thus achieved. Indeed, the ion trap is used to cool down all ions (through helium collisions) and locate them at a very well specified point in space with minimal kinetic energy before ejection for TOF measurement. During MS/MS and MSn experiments precursor ions are isolated and fragmented into the QIT, then product ions are ejected and analyzed by the TOF analyzer.

The nature and pressure of the buffer gas within the ion trap has a significant influence on mass resolution, due to different ion cooling efficiency. The effect on the mass spectrum of the [M+6H]6+ ion from bovine insuline is clearly shown: 956.6036 (-6.5 ppm) 1 m/z

Mass accuracy of 3-10 ppm is usually achieved and is independent from ionization conditions, sample, matrix type and laser power. Sensitivity is in the low femtomole (10-15 moles) range.

MALDI-QIT-TOF: a bioanalytical application The Shimadzu Axima QIT-ToF spectrometer has been used for the MS and MS/MS analysis of protein-related bidimensional polyacrylamide gel electrophoresys (2D-PAGE) spots after in-gel digestion with trypsine. Sample preparation: transfer of protein spots from Escherichia coli, separated by 2D-PAGE; on-spot enzymatic digestion by trypsin using a chemical printer to dispense the enzyme and other digestion reactants; micro-dispensing of MALDI matrix on spots previously subject to trypsin digestion.

MS spectra MS/MS spectra

LC-ESI-QIT–TOF hybrid MS This hybrid instrument is similar to MALDI-QIT-TOF, at least in principle. The only, though significant, difference is that ions are continuously transferred by the ESI source (whereas MALDI is a pulsed ion source). Ion optics preceding the QIT are then required to pulse the ion beam entering the trap. In the Shimadzu LC-MS-IT-TOF this function is effected by the combination of a skimmer, a octopole and a single lens assembly: CDL : Curved Desolvation Line

MS/MS and MSn experiments can be performed, as usual, in the 3D-ion trap of the LC-MS-IT-TOF. In the Shimadzu instrument a new technology is adopted for precursor ion fragmentation through CID. Indeed, the buffer gas, Argon, is pulsed through a valve into the trap just before a CID experiment. Ar pulsing improves the dependence of the signal related to product ions (purple points) on excitation voltage amplitude, thus increasing the S/N ratio of MS/MS and MSn spectra:

Ion transfer from the 3D-ion trap to the TOF analyzer must occur in a very short time, to avoid excessive temporal spreading. In the Shimadzu LCMS-IT-TOF the transfer is achieved through a technology known as Ballistic Ion Extraction (BIE): When the ions to be transferred (precursor or product ions) are ready inside the trap the ring electrode is grounded while a high dc voltage pulse is applied between the end caps so that ions are pushed towards the TOF analyzer.

Analysis of a mixture of drugs by LC-ESI-IT-TOF-MS:

Collisional focusing quadrupole ion guide MALDI-Q-TOF Hybrid MS (with orthogonal injection) In this system a quadrupole ion guide focuses ions that are coming off the source, thus reducing their energy distribution to improve resolution and sensitivity: Ions exiting the quadrupole are transferred to the TOF analyzer by orthogonal injection, a technique developed already in the 1960s but introduced in commercial spectrometers only 30 years later. Orthogonal injection is effected by a device known as Ion modulator or Pusher. laser TOF Collisional focusing quadrupole ion guide

Ion modulator/pusher VTOF Ions exiting the quadrupole are transferred by ion optics in a storage region, limited by a plate and a grid (G1), that are initially kept at the same potential (0 V). The ions can move along their original direction in this field-free region. Push-out pulse storage region plate ions kHz frequency G1 VTOF G2 Afterwards, an injection (push-out) voltage pulse is applied to the plate: the ions are thus pushed in the orthogonal direction. Once passed through grid 1, they are subject to a VTOF voltage, applied to grid 2 (G2), pushing them inside the TOF analyzer. When all ions have moved to the drift region of the TOF analyzer, the voltage on the plate and on Grid 1 is restored to 0 V and ions from the ion source begin to fill the storage region again.

VTOF plate G1 G2 ions It is worth noting that orthogonal acceleration gives ion velocity a new component (blue vector), normal to that related to their initial velocity (red vector). The resulting drift trajectories are then inclined (green vector). Ions entering the pusher must have a limited energy spread, otherwise a spread in drift trajectories will be observed.

RF-only or mass selecting quadrupole (RP = 1000-2000) LC-ESI-Q(q)TOF hybrid MS Orthogonal injection is the best way to couple continuous ion sources (like API ones) with a TOF analyzer. This approach has been applied in hybrid quadrupole-TOF (Q-TOF) spectrometers, having also MS/MS capabilities, due to the presence of a collision cell. The Qstar series spectrometers, from Applied Biosystems, are an example: RF-only quadrupoles RF-only or mass selecting quadrupole (RP = 1000-2000) Reflectron-TOF (RP = 10000) Note standard lockspray source T-WAVE ion guide Quadrupole pDRE lens located in front of collision cell T-WAVE collision cell New design of transfer optics after collision cell Modular Tof head equipped oa-Tof with V and W optics

In a Q(q)-TOF instrument pressure needs to be carefully controlled in each region (by combining the size of apertures joining adjacent regions and the pumping speed):

The presence of a significant gas pressure (10 mTorr) in quadrupoles Q0 and Q2, due, respectively, to a mixture of air and ESI solvents vapors and to purposely introduced Argon, is fundamental to ensure collisional dampening in Q0 (i.e. reduction of the initial energetic and spatial spread of ions) and CID of precursor ions (selected by Q1) – collisional dampening of product ions in Q2 The mean free path for ions at 10 mTorr is ca. 5 mm, thus each ion is typically involved in 10-100 collisions in Q0 and Q2.

Importance of ion kinetic energies in a Q(q)TOF spectrometer When leaving the Q0 ions possess low (thermal) kinetic energies (< 10 eV). Their fate in the subsequent regions of the spectrometer, related to the chosen analysis mode, is determined by acceleration potentials adopted between the quadrupoles (offset voltages OV1 and OV2): OV1 OV2 MS Mode OV1 = 10-30 V, Q1 in RF-only mode, OV2 = 10-20 V: ions are thermalized and focused on the central axis but not fragmented CID-MS/MS Mode OV1 = 10-30 V, Q1 in mass selective mode, OV2 = 100-300 V: CID occurs in the first part of Q2, then thermalization of product ions occurs

Duty cycle of a Q(q)TOF spectrometer In a Q(q)TOF spectrometer only ions present in the storage region of the Ion Modulator/Pusher are actually pushed to the TOF when a pulse is applied: All the other ions are lost, thus reducing the Duty Cycle of Q(q)TOF instruments to 5-30%. Depending on the m/z range of interest, pulse frequencies vary between 5 and 15 kHz. For a 10 kHz frequency a inter-pulse time of 0.1 ms is adopted, being approximatively the time required for the highest m/z ions to arrive at the detector.

Double reflectron-LC-ESI-Q-TOF hybrid MS A more complex Q(q)TOF instrumentation is represented by the Waters-Micromass QToF series. In the Q-ToF Ultima/Micro instrument the TOF analyzer is equipped with a second reflectron and the collision cell is a hexapole: Second reflectron

The highest resolving power (about 17000) is obtained when the second reflectron is active, i.e. in the so-called W mode, usually adopted for special MS measurements: In this case the first quadrupole and the collision cell are used as ion bridges, i.e. in the RF-only mode, to transfer ions incoming from the ESI source to the TOF analyzer.

When MS/MS measurements are required, only one reflectron is usually active, thus the TOF is operated in the V-mode, with a maximum resolving power about 10000: In this case the quadrupole operates in mass selective scan mode and the hexapole as a collision cell, in which precursor ions, incoming from the quadrupole and accelerated by an offset voltage, undergo CID against Argon atoms.

A Z-spray ESI-source is usually mounted on the Micromass spectrometers: In order to enhance ESI efficiency, in the Z-spray source ion sampling occurs in an orthogonal geometry and is assisted by a cone gas, that effects desolvation before ions enter the ion block.

Lockspray source The Lockspray is a special ESI source providing the capability to introduce a reference compound through a different electrospray probe. A baffle oscillating at a user-defined frequency allows alternate analysis of sample and reference spray. m/z drifts naturally occuring in TOF analyzers (i.e. due to flight tube micro-deformations induced by laboratory temperature modifications) can be corrected using the m/z value(s) of the reference compound. Mass accuracies lower than 5 ppm can be usually achieved. The in-source introduction of the reference compound avoids interferences with the LC separation of analytes.