The Armamentarium 4 PARTS: 1) The Syringe 2) The Needle 3) The Cartridge 4) Preparation.

Slides:



Advertisements
Similar presentations
Pneumatic Cylinders Chapter 3.
Advertisements

Laboratory Animal Handling Technique
The Cartridge.
Armamentarium.
What you need to know about ASPIJECT ® & local dental anaesthesia Quality you can Feel! ASPIJECT.
Local Anesthetics Armamentarium
OTHER INSTRUMENTS USED IN DENTAL CLINIC
Oral Surgy In Children N.A.GH. Oral Surgy In Children N.A.GH.
Injection for Medications
Preparing the Anesthetic Syringe
Preparing and Administering Medications
What Next? What to do if you do not achieve adequate anesthesia
Clinical Skills Formative Quiz
SOL-CARE ® Luer Lock Safety Syringe. SOL-MILLENNIUM Medical introduces the new SOL-CARE ® luer lock safety syringe, a product of the SOL-CARE® safety.
DENTAL GROSS ANATOMY CASE 4.1 (INFERIOR ALVEOLAR NERVE BLOCK)
EQUIPMENT IN L.A. Equipment has been developed for LA administration to be convenient in use and to be sterile ( read history). Sterilization: removal.
Training Slides Clinical Employees. Sharps Injury Prevention Where do You fit into the puzzle of sharps safety????
PerSys Paediatric Bone Injection Gun B.I.G.. INTRAOSSEOUS ACCESS Penetration of the bone in order to access the intravascular compartment Device inserted.
Use and Maintenance of Micro-pipettes
Measuring Small Amounts Part 1: Using pipets and micropipets.
给 药 ( 三 ) 中国医科大学护理学院 王健. Medications (three) PARENTERAL MEDICATIONS Nurses given parenteral medications intradermally (ID), subcutaneously (SC or SQ),
Oct. 22, 2012 Generosity Ludicrous: causing or deserving laughter because of absurdity Do Now: What is a microliter? How many microliter are in one liter?
Local Anesthesia and Use of Rubber Dam in Pediatric Dentistry Maha ALSARHEED.
Parenteral Medication Administration Devices Parenteral administration –Topical and transdermal medications –Inhalers –Sublingual medications –Injections.
Laboratory Animal Handling Technique
MAXILLARY ANESTHESIA. Basic Injection Technique Check flow of local anesthetic Position the patient Prepare the tissue Communicate with the patient Establish.
DENT 1160 Pharmacology Local Anesthetic 1. Aspirating syringe Has harpoon, so Dr can inject a small amount and pull back to check for blood in carpule.
MAXILLARY ANESTHESIA.
U-100 U-40 REDORANGE Only U-40 Syringes (with markings up to 40 ) should be used with a U - 40 insulin vial. Only U-100 syringe ( with marking up to 100.
Subcutaneous Intramuscular Injections
©2013 Delmar, Cengage Learning. All Rights Reserved. May not be scanned, copied, duplicated, or posted to a publicly accessible website, in whole or in.
Assisting with minor surgery and suture removal. Minor Surgery includes Removal of warts, cysts, tumors, growths, foreign objects Performing biopsies.
Colorado Agriscience Curriculum
Cytology and Cytological Techniques
The Disposable Infusion Pump Instruction Basal + PCA Bolus Model.
Intramuscular Injections
Administration of Vaccine via Intramuscular Route
Without reference, identify principles about Anesthesia Units with at least 70 percent accuracy.
Copyright © 2006 Thomson Delmar Learning. ALL RIGHTS RESERVED. 1 PowerPoint ® Presentation for Oral Health, Nutrition, and Anatomy and Physiology Module:
Periodontal Ligament Injection
SPECIAL TECHNIQUES. Indication For Special Technique InfectionPathologyTrismusTrauma.
Anesthesia and Sedation
Epidural Anaesthesia.
Pain Relief in Labor.
Intravenous cannulation
Canine and Feline Blood Sample Collection Objective: To understand the patient’s preparation, positioning, and procedures for blood collection using venipuncture.
Chapter 47b.
Use and Maintenance of Micro-pipettes
Lesson XIII: Anesthesia
Injectable Medications
PALATAL ANESTHESIA.
Medication Dosage and Administration
Parenteral Equipment and Supplies
Local Anesthesia for the Dental Hygienist
Chapter 4 Medication Administration
NEEDLE AND SYRINGE.
Techniques in Molecular Biology 2017 Fall Lecture -2-
Techniques in Molecular Biology 2017 Fall Lecture -2-
Giving Medications to animals by injection
ABOUT THIS PRESENTATION For Instructor Use Only
Allergic Reaction Protocol Preparing & Administering Epinephrine IM
INSULIN BY PEN 12/2008.
Use and Maintenance of Micro-pipettes
PDLA Advantages and Indications
MAXILLARY ANESTHESIA.
Presented by: 1) Samar Magdy Mahmud 2) Sandy Haitham Roman
Giving Medications to animals by injection
INSULIN BY PEN 12/2008.
Parenteral Dosages Chapter 12
Presentation transcript:

The Armamentarium 4 PARTS: 1) The Syringe 2) The Needle 3) The Cartridge 4) Preparation

The Syringe Standard of Care  aspirating dental syringes are the standard of care due to their ability to aspirate blood if the tip of the needle is located intravascularly

ADA Standards for Injection Syringes They must be durable and able to withstand repeated sterilization without damage 2. They should be capable of accepting a wide variety of cartridges and needles from different manufacturers and permit repeated use 3. They should be inexpensive, self-contained, lightweight and simple to use with one hand 4. Provide aspiration so blood can be seen through the glass cartridge

Breech-Loading, Metallic, Cartridge-Type, Aspirating #1 Used Syringe In Dentistry -breech loading implies that the dental cartridge is loaded from the side -a needle is attached to the barrel of the syringe at the needle adaptor -the needle passes into the barrel and pierces the diaphragm of the local anesthetic cartridge

Aspirating Syringe -the needle adaptor is sometimes inadvertently discarded along with the disposable needle -the harpoon is a sharp tip attached to the piston and is responsible for penetrating the thick silicone rubber stopper (bung) at the other end of the cartridge

- negative pressure is applied to the thumb ring by the administrator, if blood enters the glass local anesthetic cartridge (carpule) then the tip of the needle is inserted into the lumen of a blood vessel chrome-plated brass and stainless steel

-incidence of positive aspiration is between 10-15% for some injections -aspiration before injection of local anesthetic is accepted in the practice of dentistry and is overlooked to a great extent -these syringes use the elasticity of the rubber diaphragm in the anesthetic cartridge to obtain the necessary negative pressure for aspiration

-multiple aspirations are possible with very little effort due to a small metal projection that applies pressure to the rubber diaphragm when the thumb ring is depressed  negative pressure  aspiration -this type of aspiration is as reliable as using the harpoon to check for blood aspiration

Self-Aspirating Syringes -Major factor for aspiration is the gauge of the needle being used -Most doctors using the harpoon-type syringe, retract the thumb ring back too far and with excessive force which frequently disengages the harpoon from the silicone rubber stopper of the cartridge

-1st generation self-aspirating syringes required a thumb disk which forced the operator to remove their index and middle fingers from the thumb ring to the thumb disk to aspirate -2nd generation self-aspirating syringes have removed this thumb disk -Dentists only need to stop applying pressure to the thumb ring for aspiration; aspiration becomes very easy to do

Pressure Syringes -PDL (intraligamentary) injections make it possible to achieve single tooth pulpal anesthesia in the mandible when, in the past, complete IANB was necessary

-pressure syringes can allow too easy of an administration of local anesthetic producing pain and post-operative discomfort -pressure syringes are expensive > $200.00 -can shatter glass cartridge if too much pressure is applied too quickly

2000 psi Jet Syringes ($1,600) -needle-less injection -liquids forced through very small openings, called jets, at very high pressure can penetrate skin or intact mucous membrane -Syrijet is the most popular used today -Syrijet holds any 1.8 ml cartridge of local anesthetic

-Syrijet is calibrated to deliver. 05 to -Syrijet is calibrated to deliver .05 to .2 ml of solution at 2000 psi; traditional syringes deliver 600 psi maximum -primary use is to obtain topical anesthesia before using a needle -regional nerve blocks/supraperiosteal injections are still necessary -topical anesthetics provide the same effect at a fraction of the cost -patients complain of soreness where the 2000 psi hit their tissue

Safety Syringe -Aspiration is possible -some brands come with an autoclavable plunger and disposable self-contained injection unit -all dental safety syringes are made to be single use items

-more expensive than reusable syringe units -sliding the index and middle finger forward against the front collar of the guard makes the needle “safe” by sliding a protective plastic sheath over the needle tip that locks into place -more expensive than reusable syringe units -large disadvantage arises when it comes to re-injecting; complication ensues due to the needle tips newly acquired safety coping

CCLAD (Computer Controlled Local Anesthetic Delivery -designed to improve ergonomics and precision of injection technique -foot activated delivery of solution using finger tip precision -pen-like grasp offers increased tactile sensation

The Wand -flow rates of solution delivery are computer controlled and remain consistent operator is able to focus attention on the position of the needle tip while the motor of the machine delivers local anesthetic at a preprogrammed rate of flow 50 Dentists were injected with traditional syringes and The Wand; 48 of 50 Dentists preferred to be injected again themselves with The Wand due to a reported threefold decrease in the interpretation of pain

-The Wand is less threatening to the patients visually -allows two rates of delivery: 1) Slow: .5 ml/minute 2) Fast: 1.8 ml/minute -releasing the foot rheo-stat will tell the machine to aspirate automatically; the aspiration cycle is approximately 4.5 seconds

-less painful PDL, palatal, attached gingiva injections -extremely high pressure in non-resilient tissues cause (traditional syringe) moderate/severe pain in most patients The Wand eliminates a lot of this discomfort by maintaining constant pressure delivery of the solution -less painful PDL, palatal, attached gingiva injections

References Malamed, Stanley: Handbook of Local Anesthesia. 5th Edition. Mosby. 2004