Transverse size and distribution of FEL x-ray radiation of the LCLS

Slides:



Advertisements
Similar presentations
First Steps XFEL S2E with CSRtrack Convert elegant particlefile upstream of BC-3 into CSRtrack input CSRtrack results.
Advertisements

5/3/2015J-PARC1 Transverse Matching Using Transverse Profiles and Longitudinal Beam arrival Times.
1 Optimal focusing lattice for XFEL undulators: Numerical simulations Vitali Khachatryan, Artur Tarloyan CANDLE, DESY/MPY
05/03/2004 Measurement of Bunch Length Using Spectral Analysis of Incoherent Fluctuations Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
P. Emma FAC Meeting 7 Apr Low-Charge LCLS Operating Point Including FEL Simulations P. Emma 1, W. Fawley 2, Z. Huang 1, C.
A. Zholents, July 28, 2004 Timing Controls Using Enhanced SASE Technique *) A. Zholents or *) towards absolute synchronization between “visible” pump and.
James Welch October 30, FEL Commissioning Plans J. Welch, et. al. FEL Commissioning Plans J. Welch, et. al. Accelerator.
1 Daniel Ratner 1 Gain Length and Taper August, 2009 FEL Gain length and Taper Measurements at LCLS D. Ratner A. Brachmann, F.J.
Spontaneous Radiation at LCLS Sven Reiche UCLA - 09/22/04 Sven Reiche UCLA - 09/22/04.
Latest Results on HXRSS at LCLS Franz-Josef Decker 4-Feb Seeding with 004, 220 and over-compression 2.Tuned beam with slotted foil cutting horns.
A. Doyuran, L. DiMauro, W. Graves, R. Heese, E. D. Johnson, S. Krinsky, H. Loos, J.B. Murphy, G. Rakowsky, J. Rose, T. Shaftan, B. Sheehy, Y. Shen, J.
LOLA setup simulated LOLA measurement*: no transverse beam dimensions imaging: entrance-LOLA to OTR simulated LOLA measurement*: gaussian transverse shape.
Two Longitudinal Space Charge Amplifiers and a Poisson Solver for Periodic Micro Structures Longitudinal Space Charge Amplifier 1: Longitudinal Space Charge.
Assessing Single Crystal Diamond Quality
Simulation of Microbunching Instability in LCLS with Laser-Heater Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
Coherent Diffraction Radiation experiment Konstantin Lekomtsev, Grahame Blair, Gary Boorman, Pavel Karataev, Maximilian Micheler John Adams Institute at.
A bunch compressor design and several X-band FELs Yipeng Sun, ARD/SLAC , LCLS-II meeting.
Harmonic lasing in the LCLS-II (a work in progress…) G. Marcus, et al. 03/11/2014.
W.S. Graves 2002 Berlin CSR workshop 1 Microbunching and CSR experiments at BNL’s Source Development Lab William S. Graves ICFA CSR Workshop Berlin, Jan.,
LCLS-II Particle Tracking: Gun to Undulator P. Emma Jan. 12, 2011.
The Microbunching Instability in the LCLS-II Linac LCLS-II Planning Meeting October 23, 2013 A. Marinelli and Z. Huang.
Lessons Learned From the First Operation of the LCLS for Users Presented by Josef Frisch For the LCLS March 14, 2010.
Preliminary Tracking Results through LCLS-II P. Emma et al., Oct. 23, 2013 Thanks to Mark Woodley and Yuri Nosochkov for MAD design work Use Christos Papadopoulos.
FEL Spectral Measurements at LCLS J. Welch FEL2011, Shanghai China, Aug. 25 THOB5.
XFEL Beam Dynamics Meeting Bolko Beutner, DESY First results of micro-bunching and COTR experiments at FLASH Bolko Beutner, Winfried Decking,
Microbunching Instability and Slice Energy Spread
PAL-XFEL Commissioning Plan ver. 1.1, August 2015 PAL-XFEL Beam Dynamics Group.
LCLS-II options: CuRF → SXR, VPU, HXR harmonics G. Marcus 5/13/2015.
Some Simulations for the Proposed Hard X-Ray Self- Seeding on LCLS J. Wu J. Wu et al. Feb. 25, 2011.
OPERATED BY STANFORD UNIVERSITY FOR THE U.S. DEPT. OF ENERGY 1 Alexander Novokhatski April 13, 2016 Beam Heating due to Coherent Synchrotron Radiation.
Free Electron Laser Studies
LSC/CSR Instability Introduction (origin of the instability) CSR/LSC
Seeding in the presence of microbunching
Slice Parameter Measurements at the SwissFEL Injector Test Facility
Short pulse, low charge LCLS operation
Summary of experience with Tevatron synchrotron light diagnostics
Tunable Electron Bunch Train Generation at Tsinghua University
Sven Reiche UCLA ICFA-Workshop - Sardinia 07/02
Undulator Tolerances for LCLS-II using SCUs
XFEL Beam Physics 10/30/2015 Tor Raubenheimer.
EEHG 101: The Basics of Echo-7
Time-Resolved Images of Coherent Synchrotron Radiation Effects
Laser assisted emittance exchange to reduce the X-ray FEL size
G. Marcus, Y. Ding, J. Qiang 02/06/2017
TW FEL “Death-Ray“ Studies
Reconstruction algorithms Challenges & Future work
LCLS bunch length monitor utilizing coherent radiation
Z. Huang LCLS Lehman Review May 14, 2009
Two-bunch self-seeding for narrow-bandwidth hard x-ray FELs
SASE FEL PULSE DURATION ANALYSIS FROM SPECTRAL CORRELATION FUNCTION
High Level Physics Applications for LCLS Commissioning
Modified Beam Parameter Range
Longitudinal-to-transverse mapping and emittance transfer
Longitudinal-to-transverse mapping and emittance transfer
Gain Computation Sven Reiche, UCLA April 24, 2002
Injector Experimental Results John Schmerge, SSRL/SLAC April 24, 2002
Transverse coherence and polarization measurement of 131 nm coherent femtosecond pulses from a seeded FEL J. Schwenke, E. Mansten, F. Lindau, N. Cutic,
Optics John Arthur, SLAC & William W. Craig, LLNL April 24, 2002
LCLS FEL Parameters Heinz-Dieter Nuhn, SLAC / SSRL April 23, 2002
First results of micro-bunching and COTR experiments at FLASH
Diagnostics RF and Feedback
Linac Diagnostics Commissioning Experience
Coherent X-ray Imaging Instrument WBS 1.3
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
P. Emma, for the LCLS Commissioning Team LCLS DOE Review May 14, 2009
Enhanced Self-Amplified Spontaneous Emission
Electron Optics & Bunch Compression
LHC BIF test setup - update
LCLS Lehman Review February 7-9, 2005
Presentation transcript:

Transverse size and distribution of FEL x-ray radiation of the LCLS James L. Turner August 25, 2011

Introduction Talk is about around 8keV hard xrays Measurement setup. Attenuation, Linearity, Backgrounds Simulation and Measurement of hard xray FEL spot before mirrors Microbunching and CSR Size and divergence Beam profile after the hard xray mirrors

Some LCLS reference points solid and gas attenuators gas detectors HXR mirrors SXR mirrors K-mono Direct Imager YAG undulator vert. dump XPP Simulation point Simulation and measurement point Measurement point

Measurement Setup YAG Intensity Profile Monitors Attenuation camera and beam Attenuating the beam with the materials we use requires care to not saturate the YAG while not attenuating enough fundamental to have a significant amount of 3rd harmonic. Typically 1-10% of beam intensity is allowed through. High purity Be showed speckles, now we use diamond, sapphire, fused silica, and silicon.

Background Sources Spontaneous radiation from the undulators (synchrotron radiation) Electron beam is kicked transversely to suppress lasing, then background is acquired for later subtraction. CSR (coherent synchrotron radiation) from the first bend in the final bend string which removes the electrons from the xray path. 1 micron carbon filter is used on the beam path

Background Sources Unknown uniform luminescence (possibly CSR bouncing off the walls, or gas detector florescence) For gaussian hard xrays a “region of interest” can be cut where any uniform background will be baseline.

Saturation check Linearity check – pixel intensity sum vs. gas detector signal.

Simulation and Measurement Qualitative similarity is striking. Xrays from 250pC electron bunch (laser heater on and aligned) 8.3keV xray distribution, 3kA Left is Genesis simulation at end of undulator. Right is measurement at ~+90m. So, simulation is near field and measurement is far field. At ~1kA both are round (not shown).

Measurement Laser Heater On/Off Hard xrays from 150pC electron bunch, left is with Laser Heater on and well aligned. Right is Laser Heater off. Also compare on picture at 150pC to 250pC on previous slide.

Hard Xrays before Mirrors Data Turning down the number of electrons increases distribution uniformity Turning down peak current increases distribution uniformity Having laser heater on and aligned increases distribution uniformity Conclusion Likely CSR exacerbated by microbunching causing non-uniformity Turning down the electron current was recommended from 2001 simulations (using Parmela, Elegant, and Genesis)

Hard Xray Beam Size Quadrupole for matching into the undulator lattice is scanned around the match condition. Xray size minimizes at the match condition.

Slice Divergence Slice FWHM divergence measurement using slotted foil. Blue is the un-weighted mean, and Red is a weighted fitted line. Given the large errors due to fluctuations in the lasing of the slices, data is consistent with little or no divergence change along the beam. Divergence typically varies from 2-4 microradians FWHM.

After the Hard Xray Mirrors Two effects from hard xray mirrors are seen on intensity profile monitors after the mirrors, some interference lines come from cutting the beam, but by far the dominant effect is from the figure error.

Simulation: beam cut by hard xray mirrors Simulation of overfilling the mirrors, but no figure error is included. Projections on the left plot, blue to horizontal, red to vertical.

Hard xray mirror figure error The figure (millimeter to meter deviations) of the two LCLS hard xray mirrors. One is represented by the red, the other in blue. Vertical scale is in nanometers, horizontal is the length along the mirrors in millimeters.

Simulated and measured: hard xrays after mirrors Left is simulation including figure errors, right is measurement at XPP monitor (courtesy of David Fritz). There was some upstream clipping on the left side. Tic marks are 200microns apart for scale.

Summary Size and divergence measurements require care with backgrounds Measurements and simulations have agreement on non-gaussian profile generation. Measurement and simulations agree and show mirror figure errors have the dominant effect on beam shape. This makes nanometer level metrology and control very important for xfels.

LCLS – Spatial Fluctuations 200 um Thanks to David Fritz (LCLS XPP) Transverse size and distribution of FEL x-ray radiation of the LCLS