THE i DEA M AKES i DEAL YL6500 GC. 680A M600D YL6100 The History of GC Development 1991 1995 Acme 6000 2001 2006 2011 INNOVATIVE YL6500GC.

Slides:



Advertisements
Similar presentations
CLEAN FORMAT FASTER NAVIGATION PRODUCT SELECTION GUIDES UPDATED INFORMATION WEBSITE ENHANCEMENTS.
Advertisements

Micro-GC channel with µ-TCD
1 The YL9100S HPLC All your needs for semi-preparative applications.
Quantitative Gas Chromatography
Gas Chromatography.
GAS CHROMATOGRAPHY CHAPTER 21.
Gas Chromatography Lecture 36.
Gas Chromatography Vaporization of sample Gas-solid
Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
CAPILLARY GC INLETS.
GC.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
Lab Methods Day June 25, 2014 Gas Chromatography
The Foundations: Classical Split and Splitless Injection
Chromatography Integration and Trouble-shooting
Chem. 230 – 10/14 Lecture. Announcements I Some Comments on Homework –glucose/levoglucosan separation: since R s = 2.3, resolution was more than optimal.
Mobile phase is a gas! Stationary phase could be anything but a gas
Compact & Perfect for Your Satisfaction
Flame Ionization Detector Most common detector Carbon atoms (C-C bonds) are burned in a hydrogen flame. A small portion of carbon atoms are ionized (about.
Instrumental Analysis
Experiment 6 Simple and Fractional Distillation.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
Dehydration of 2-Butanol and Dehydrobromination of 2-Bromobutane;
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Monitoring the desorption of analytes from nonpolar SPME fibers using high speed gas chromatography Authors: Kimberly Jasch, Tony Borgerding* Department.
AC Analytical Controls January 2001
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
GC Detectors Ideal Detector Characteristics: 1. Universal Response
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
가스크로마토그래피 기기의 구성과 기능.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
GAS – LIQUID CHROMATOGRAPHY BY M. GLORY HEPSIBAH M.PHARM (PH. ANALYSIS) BHARAT COLLEGE OF PHARMACY.
474 PHG 5.
Chapter 27 Gas Chromatography 1. Principles
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
animation.php.
Chromatography vObjective  To understand the principles of chromatography and know the specific types of Chromatograph used in the analysis of environmental.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Advanced Method for Renewable Ethanol by Direct Synthesis from Syngas for Renewable Fuel Applications Julia Fisher, Chemical Engineering, Arizona State.
Gas Chromatography: Detectors. The Ideal Detector n Adequate sensitivity - range 10 ^- 18 to 10^-15 g analyte/s n good stability and reproducibility n.
PAS-Intro1 Dated 24th Aug Copyright © Siemens AG 1999 All Rights Reserved Siemens Advanced Engineering Pte Ltd Process Analytical Services Division.
Gas Chromatography Lecture 38.
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
Lecture 4a Gas Chromatography.
GAS CHROMATOGRAPHY In gas chromatography (GC), the sample is injected onto the head of a chromatographic column and immediately vaporized. The components.
GAS LIQUID CHROMATOGRAPHY Principles Partition of molecules between gas (mobile phase) and liquid (stationary phase).
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
Laboratory microwave oven 2.45 GHz multimode microwave reactor Maximum power of 900w The experimental SFME variables were optimised in order.
K V GOPINATH M Pharm PhD,CPhT Tirumala Tirupati Devasthanams TIRUPATI GAS CHROMATOGRAPHY.
Gas Chromatography Oleh : Rohayati, S.Pd SMK Negeri 13 Bandung.
Thermal Conductivity Detector
Gas Chromatography.
M.PRASAD NAIDU Msc Medical Biochemistry, Ph.D Research scholar.
Gas Chromatography Chap 27 Types: Gas-solid chromatography (GSC)
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
Ed Connor, GC Product Specialist
GC Trouble shooting.
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
Ariovaldo Bisi Chromatography line leader Export
Advancements in Gas Chromatography Analyzers - Keeping up with New Technology Chuck Runkle Gas Phase Product Specialist ASTS June 2013.
Gas Chromatography.
GC and GC-MS.
Gas Chromatography.
32A-4 Chromatographic Detectors
GAS CHROMATOGRAPHY.
Presentation transcript:

THE i DEA M AKES i DEAL YL6500 GC

680A M600D YL6100 The History of GC Development Acme INNOVATIVE YL6500GC

YL6500 GC Features YL6500GC comes with Enhanced 4 V s View Verification Variety Value

YL6500 GC Features Enjoy the View Enlarged Haptic color LCD(5.7) showing all factors at a glance. Classic and lab-suitable Design Intuitive and user-friendly view by YL chromatography data system

YL6500 GC Features Reliable Verification Strongly Enhanced APCs for almost all detectors - Increased precision in pressure and flow rate - Automatic compensation for temperature & pressure in installation condition - Pressure setpoint increment : 0.01 psi /Pressure stability : ±0.001 psi - Shockproof APCs with short flow length - 4 column flow control modes: constant pressure, constant flow, programmed pressure (5 steps), programmed flow (5 steps). - Stable APCs against oven temperature changes - Up to six APCs can be installed and up to 18 channels of APC.

YL6500 GC Features Reliable Verification: (1) Reproducibility Test

YL6500 GC Features Reliable Verification: (2) Complex Analysis Accurate & Precise Valve Switching Time Increment : 0.01 min * Accurate control of valve switching time in settable point up to 0.01 min allows analyzing complex samples containing various components that can not be separated by one column or detected by one detector reversing column flow precisely(Backflush) with no loss of peak area values.

YL6500 GC Features Reliable Verification High speed data process by network (LAN) communication Ten heated Zones to enhance a precision : 1 heated oven zone/ 3 heated injector zone 3 heated detector zone/ 2 heated valve zone 1 heated methanizer zone Powerful and easy control by YL chromatography software

YL6500 GC Features Wide Variety Maximum no. of inlet / detector to be installed : 3 Various inlets available - Capillary Inlet - Packed Inlet - On-Column Inlet (Temperature programming up to 5 steps)

YL6500 GC Features Wide Variety Various detectors with high sensitivity available - Flame Ionization Detector (FID) : MDL < 2.0 pg C/sec - Thermal Conductivity Detector (TCD) : MDL < 2.5 ng /ml - Micro- Thermal Conductivity Detector (μTCD) : MDL < 400 pg/ml - Nitrogen Phosphorus Detector(NPD) - Flame Photometric Detector (FPD) - Electron Capture Detector(ECD) : MDL < 10 fg/sec - Pulsed discharge Detector (PDD) - Pursed Frame Photometric Detector (PFPD)

YL6500 GC Features Upgrade the Value Reasonable price saving users valuable time Improved column conditioning function : Automatic set of split flow up to 5ml/min on column conditioning Sensitive leak detection (H 2 ) Prevention of oven malfunction (Over heating) Automatic stop when an oven door gets opened during operation. Time control: Automatic turn-on/off

YL6500 GC Modules Superior Performance in Column Oven Usable volume : 14L Temperature operating range : (ambient to 450 or more) : - 80 ~ 450 (with LN 2 cryogenic cooling) : - 55 ~ 450 (with CO 2 cryogenic cooling) Temperature set-point : 1 Programming: 25 ramps, 26 steps temperature program Maximum set-point heating rate: 100 /min Temperature program method: Maximum up to 20 Temperature stability : ±0.01 (Isothermal)

YL6500 GC Modules Enhanced Performance in Inlets Packed inlet - Maximum Temperature : Pressure setting range : 0.01 ~ 100 psi - Total flow setting range : 0.1~100 ml/min - Flow stability < ±0.05ml/min - Pressure stability < ± 0.05psi - Temperature setpoint : 1 - Temperature stability < ±0.1

YL6500 GC Modules Enhanced Performance in Inlets Capillary inlet (Split/Splitless) - Maximum temperature : Pressure setting range : 0.01 ~ 100 psi - Total flow setting range : 0.1 ~ 400 ml/min N 2 0 ~ 1000ml/min He - Splitless time setpoint : 0.01min - Total flow stability < ±0.05ml/min - Pressure stability < ± 0.05psi - Temperature setpoint : 1 - Temperature stability < ±0.1

YL6500 GC Modules Enhanced Performance in Inlets On-column Inlet - Maximum Temperature : Pressure setting range : 0.01 ~ 100 psi - Total flow setting range : 0.1 ~ 100 ml/min - Flow stability < ±0.05ml/min - Pressure stability < ± 0.05psi - Temperature setpoint : 1 - Temperature stability < ±0.1 - Temperature programming up to 5 steps

YL6500 GC Modules Exceptional Sensitivity in Detectors Flame Ionization Detector - Maximum operating temperature : Automatic flame ignition - Temperature set-point : 1 - Ignition message: Alarm message as Flame out - MDL : 2.0 pg carbon/sec - Linear dynamic range : Temperature stability : ± Data acquisition rate : 200 Hz

YL6500 GC Modules Analysis condition -Column: Innowax, 30m x 0.32mm x 0.5um -Oven: 100 (5min) 4 /min 240 (10min) -Injector : 250 -Detector : 280 * Fatty Acid Methyl Esters Analysis by FID

YL6500 GC Modules Exceptional Sensitivity in Detectors Thermal Conductivity Detector - Maximum operating temperature : Flow through cell : 4 Rhenium-Tungsten filaments - Temperature set-point : 1 - Filament protection - MDL : 2.5 ng/ml - Micro-cell (Option) : μTCD (MDL < 400 pg/ml) - Data acquisition rate : 200 Hz

YL6500 GC Modules Analysis Condition Oven : 35 (5min) 10 /min 225 (5min) Column : Carboxen1000, 1/8", 15ft, 60/80 mesh Carrier gas : He, 25 ml/min Injector : 120°C Detector : TCD(120 ), Sens 6 Injection Volume : 1ml * Carboxen 1000 Analysis by TCD

YL6500 GC Modules Exceptional Sensitivity in Detectors Electron Capture Detector - Maximum operating temperature : MDL : 10 fg/sec - Dynamic Range : > Radionuclide(Estimated Content Activity) : Ni-63 (555 MBq)

YL6500 GC Modules * Residual pesticides Analysis by ECD Analysis Condition Column: HP-5 30m x 0.32mm x 0.25um Oven: 80 (2min) - 10 /min (8min) Injector: 280 Detector: 300, Make up gas: 40ml/min

YL6500 GC Modules Exceptional Sensitivity in Detectors Nitrogen Phosphorous Detector - Maximum operating temperature : MDL : <0.4 pg N/sec (Azobenzene) <0.2 pg P/sec (Malathion) - Dynamic Range for N : > Dynamic Range for P : > 10 4

YL6500 GC Modules Exceptional Sensitivity in Detectors Flame Photometric Detector - Maximum operating temperature : Minimum detection limit for S : < 20 pg S/sec - Minimum detection limit for P : < 0.5 pg P/sec - Dynamic Range for S : > Dynamic Range for P : > S/C Selectivity : P/C Selectivity : 10 6

YL6500 GC Modules Exceptional Sensitivity in Detectors Pulsed Discharge Detector - Maximum operating temperature : PDHID, PDECD mode is selectable - Helium ionization mode(PDHID) : Linearity – 10 5 MDL (organic compound : low ppb) (permanent gas : low ppm) - Electron capture mode(PDECD) : Linearity – 10 5 MDL – Dopant gas : 3% Xe in Helium

Specifications of YL6500GC VS A company YL6500GCA 7890A Max. Number of Heated Zones 107 Max. Number of Inlet32 Max. Number of Detectors33 (3 rd detector as TCD) Max. GC Methods Storage205 Max. Programming Ramp/Plateaus25/2620/21 Max. Channels of APC1816 FID MDL 2.0 pg carbon/sec as dodecane using N2 carrier 1.8 pg C/s (for tridecane) TCD MDL 2.5 ng/ml as dodecane μTCD : 0.4 ng/ml 0.4 ng tridecane/mL with He carrier ECD MDL <10 fg/sec as Lindane<6 fg/mL Lindane YL6500 GC Competition

Specifications of YL6500GC VS P company YL6500GCP Clarus 680 Max. Number of Heated Zones 10 Max. Number of Inlet32 Max. Number of Detectors32 Max. GC Methods Storage205 Max. Programming Ramp/Plateaus25/269/10 Max. Channels of APC1812 FID MDL 2.0 pg carbon/sec as dodecane using N2 carrier 3 pg C/s (for tridecane) TCD MDL 2.5 ng/ml as dodecane μTCD : 0.4 ng/ml 1000 ng/mL nonane ECD MDL <10 fg/sec as Lindane< 0.05 pg nitrogen YL6500 GC Competition