Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position  S.-Y. Yang, J.-K.

Slides:



Advertisements
Similar presentations
Journal of the Neurological Sciences
Advertisements

Cerebrospinal-fluid drain-related complications in patients undergoing open and endovascular repairs of thoracic and thoraco-abdominal aortic pathologies:
F. Chung, R. Subramanyam, P. Liao, E. Sasaki, C. Shapiro, Y. Sun 
Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge  K Lakhal, M.A. Nay, T Kamel, B Lortat-Jacob,
Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other.
Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantation  G. Gouvêa, R. Diaz, L.
N-terminal fragment of pro-B-type natriuretic peptide is a predictor of cardiac events in high-risk patients undergoing acute hip fracture surgery  A.
Perfusion index derived from a pulse oximeter can predict the incidence of hypotension during spinal anaesthesia for Caesarean delivery  S Toyama, M Kakumoto,
Bispectral index-guided induction of general anaesthesia in patients undergoing major abdominal surgery using propofol or etomidate: a double-blind, randomized,
Type of anaesthesia and patient quality of recovery: a randomized trial comparing propofol–remifentanil total i.v. anaesthesia with desflurane anaesthesia 
Randomized, double-blind comparison of oral aprepitant alone compared with aprepitant and transdermal scopolamine for prevention of postoperative nausea.
Comparison of positive end-expiratory pressure–induced increase in central venous pressure and passive leg raising to predict fluid responsiveness in.
Lidocaine use in ultrasound-guided femoral nerve block: what is the minimum effective anaesthetic concentration (MEAC90)?†  A.M. Taha, A.M. Abd-Elmaksoud 
Tracheal intubation by trainees does not alter the incidence or duration of postoperative sore throat and hoarseness: a teaching hospital-based propensity.
Association between fibrinogen level and severity of postpartum haemorrhage: secondary analysis of a prospective trial  M. Cortet, C. Deneux-Tharaux,
P. Cuvillon, V. Reubrecht, L. Zoric, L. Lemoine, M. Belin, O
Development and longitudinal validation of the overall benefit of analgesia score: a simple multi-dimensional quality assessment instrument  N Lehmann,
A different use of visual analytic techniques in anaesthetics
Postoperative pulmonary complications
M. Boutonnet, V. Faitot, A. Katz, L. Salomon, H. Keita 
N-terminal pro-B-type natriuretic peptide concentrations and long-term outcome after cardiac surgery: a prospective cohort study  B.H. Cuthbertson, B.L.
Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation 
T. Ledowski, J. Burke, J. Hruby  British Journal of Anaesthesia 
Mixed venous oxygen saturation predicts short- and long-term outcome after coronary artery bypass grafting surgery: a retrospective cohort analysis  J.
Role of N-terminal pro B-type natriuretic peptide in identifying patients at high risk for adverse outcome after emergent non-cardiac surgery  S. Farzi,
Stroke volume variation and indexed stroke volume measured using bioreactance predict fluid responsiveness in postoperative children†  E. Vergnaud, C.
C.C. Apfel, P. Kranke, C.-A. Greim, N. Roewer 
Continuous spinal anaesthesia and non-invasive ventilation for total knee replacement in a patient on home ventilation  J. Dawson, M. Jones, N. Hirschauer,
Do team processes really have an effect on clinical performance
Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage: intra- and interobserver agreement and relation to angiographic vasospasm and.
Ultrasound-assisted spinal anaesthesia in a patient with Wildervanck syndrome and congenital abnormalities of the lumbar spine  T. Schisler, H. Huttunen,
Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography 
Assessing fitness for surgery: a comparison of questionnaire, incremental shuttle walk, and cardiopulmonary exercise testing in general surgical patients†
Predicting cardiac output responses to passive leg raising by a PEEP-induced increase in central venous pressure, in cardiac surgery patients  B.F. Geerts,
Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation.
Distraction and interruption in anaesthetic practice
Do old pharmacokinetic parameter estimates predict new data?
S.G. Sakka, K. Reinhart, A. Meier-Hellmann 
Predicting postoperative morbidity in adult elective surgical patients using the Surgical Outcome Risk Tool (SORT)  D.J.N. Wong, C.M. Oliver, S.R. Moonesinghe 
Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery  P.-G. Guinot, B. de Broca,
Titration of electroconvulsive therapy: the use of rocuronium and sugammadex with adjunctive laryngeal mask  T.K.F. Chow  British Journal of Anaesthesia 
Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies  F.G.R. Freitas,
Visual metaphors on anaesthesia monitors do not improve anaesthetists' performance in the operating theatre  K. van Amsterdam, F. Cnossen, A. Ballast,
Non-invasive assessment of fluid responsiveness using CNAP™ technology is interchangeable with invasive arterial measurements during major open abdominal.
Spinal analgesia for laparoscopic colonic resection using an enhanced recovery after surgery programme: better analgesia, but no benefits on postoperative.
Corrigendum British Journal of Anaesthesia
C. J. Payne, S. C. Gibson, G. Bryce, A. G. Jardine, C. Berry, D. B
Respiratory systolic variation test in acutely impaired cardiac function for predicting volume responsiveness in pigs  V. Eichhorn, C. Trepte, H.P. Richter,
Do simple ventilation and gas exchange measurements predict early successful weaning from respiratory support in unselected general intensive care patients? 
Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease 
Teamwork, communication, and anaesthetic assistance in Scotland
Validity of the 6 min walk test in prediction of the anaerobic threshold before major non- cardiac surgery  R.C.F. Sinclair, A.M. Batterham, S. Davies,
Intraoperative use of transoesophageal Doppler to predict response to volume expansion in infants and neonates  O. Raux, A. Spencer, R. Fesseau, G. Mercier,
Editorial II: Solid as a ROC
Comparison of central venous and external jugular venous pressures during repair of proximal femoral fracture†  A.D. Leonard, C.M. Allsager, J.L. Parker,
Sodium bicarbonate does not prevent postoperative acute kidney injury after off-pump coronary revascularization: a double-blinded randomized controlled.
T. Saito, S.T.H. Chew, W.L. Liu, K.K. Thinn, T. Asai, L.K. Ti 
Multivariate model for predicting postoperative blood loss in children undergoing cardiac surgery: a preliminary study  V. Savan, A. Willems, D. Faraoni,
A.J. Ross, N. Kodate, J.E. Anderson, L. Thomas, P. Jaye 
Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia†  G Sharwood-Smith, J Bruce, G Drummond  British.
Influence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsiveness  F.-P. Desgranges, O. Desebbe,
H. Solus-Biguenet, M. Fleyfel, B. Tavernier, E. Kipnis, J. Onimus, E
Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery  A. Derichard, E. Robin, B. Tavernier,
Modern anaesthesia training: is it good enough?
Neck circumference to thyromental distance ratio: a new predictor of difficult intubation in obese patients  W.H. Kim, H.J. Ahn, C.J. Lee, B.S. Shin,
Predictor of fluid responsiveness in the ‘grey zone’: augmented pulse pressure variation through a temporary increase in tidal volume  J.J. Min, N.-S.
Non-invasive measurement of pulse pressure variation and systolic pressure variation using a finger cuff corresponds with intra-arterial measurement 
Controlled hypotension for middle ear surgery: a comparison between remifentanil and magnesium sulphate†   J.-H. Ryu, I.-S. Sohn, S.-H. Do  British Journal.
Lung isolation in the morbidly obese patient: a comparison of a left-sided double-lumen tracheal tube with the Arndt® wire-guided blocker  J.H. Campos,
J. Renner, O. Broch, P. Duetschke, J. Scheewe, J. Höcker, M. Moseby, O
Presentation transcript:

Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position  S.-Y. Yang, J.-K. Shim, Y. Song, S.-J. Seo, Y.-L. Kwak  British Journal of Anaesthesia  Volume 110, Issue 5, Pages 713-720 (May 2013) DOI: 10.1093/bja/aes475 Copyright © 2013 The Author(s) Terms and Conditions

Fig 1 Flowchart of patient enrolment. British Journal of Anaesthesia 2013 110, 713-720DOI: (10.1093/bja/aes475) Copyright © 2013 The Author(s) Terms and Conditions

Fig 2 Mean, sd values of PPV (a) and corrected flow time (b) before fluid loading in responders (Rs) and non-responders (NRs) in the supine position and the prone position. In both the supine and the prone positions, PPV was significantly higher and corrected flow time was significantly lower in the Rs compared with the NRs. British Journal of Anaesthesia 2013 110, 713-720DOI: (10.1093/bja/aes475) Copyright © 2013 The Author(s) Terms and Conditions

Fig 3 ROC curves of automated PPV (PPVauto) and time-corrected aortic flow (FTc) of predictability for fluid responsiveness. (a) In the supine position, the AUC of PPVauto was 0.935 (95% CI: 0.870−0.999) with a cut-off value of 15% (sensitivity 73% and specificity 94%) and the ACU of FTc was 0.822 (95% CI: 0.682−0.961) with a cut-off value of 358 ms (sensitivity 88% and specificity 78%). (b) In the prone position, the AUC of PPVauto was 0.969 (95% CI: 0.912−1.000) with a cut-off value of 14% (sensitivity 97% and specificity 90%) and the AUC of FTc was 0.846 (95% CI: 0.706−0.985) with a cut-off value of 331 ms (sensitivity 77% and specificity 90%). CI, confidence interval. British Journal of Anaesthesia 2013 110, 713-720DOI: (10.1093/bja/aes475) Copyright © 2013 The Author(s) Terms and Conditions