Biphasic Cuirass Ventilation (BCV)

Slides:



Advertisements
Similar presentations
Initiation and weaning of mechanical ventilation by Ahmed Mohamed Hassan
Advertisements

NON INVASIVE VENTILATION Definition: NIV is the delivery of mechanical ventilation to the lungs using techniques that do not require an endotracheal.
Non-invasive Ventilation
Basics of Mechanical Ventilation
Mechanical ventilation
1 Pre-ICU Training CHEST Mechanical Ventilatory Support 2008/6/20.
Educational Resources
CPAP Respiratory therapy EMT-B. CPAP Overview  Applies continuous pressure to airways to improve oxygenation.  Bridge device to improve oxygenation.
Mechanical ventilation for SARS The basics Charles Gomersall Dept of Anaesthesia & Intensive Care The Chinese University of Hong Kong Prince of Wales Hospital.
Mechanical Ventilation in the Neonate RC 290 CPAP Indications: Refractory Hypoxemia –PaO2 –Many hospitals use 50% as the upper limit before changing.
Mechanical Ventilatior
Introduction to Mechanical Ventilation
Chapter 40 Airway Clearance Therapy
Respiratory Distress Syndrome
Initiation of Mechanical Ventilation
Biphasic cuirass ventilation Identification BCVWhy?Who?How?Where?When?
High Frequency Ventilation
Ventilators for Interns
Mechanical Ventilation. Epidemiology 28 day international study –361 ICUs in 20 countries –All consecutive adult patients who received MV for > 12 hours.
Objectives Discuss the principles of monitoring the respiratory system
Ventilator.
CMV Mode Workshop.
Mechanical Ventilation Management
How a Breath is Delivered
Respiratory Failure Sa’ad Lahri Registrar Dept Of Emergency Medicine UCT / University of Stellenbosch.
MECHANICAL VENTILATION
Lung Volumes Inspiratory Reserve Volume:
Part I: Noninvasive Positive Pressure Ventilation in the Acute Care Facility By: Susan P. Pilbeam, MS, RRT, FAARC John D. Hiser, MEd, RRT, FAARC Ray Ritz,
NONINVASIVE POSITIVE PRESSURE VENTILATION NIPPV ADELYN MITCHELL, RN, BSN, CEN, BSRC NURS 5303 INFORMATION AND TECHNOLOGY.
An Intervention for airway clearance, is a means of mobilizing secretions in one or more lung segments to the central airways by placing the patient in.
High Flow Nasal Cannula for Patient Care Units- ACH
MECHANICAL VENTILATION
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Thursday, April 20, 2017 Critical care units HIKMET QUBEILAT.
Respiratory Therapy! Just breathe!.
Ventilators All you need to know is….
1 Respiratory System. 2 Outline The Respiratory Tract – The Nose – The Pharynx – The Larynx – The Bronchial Tree – The Lungs Gas Exchange Mechanisms of.
Efficacy of Non Invasive Biphasic Cuirass Ventilation (BCV) in Neonatal Piglets Comparison with Conventional Positive Pressure Ventilation F.G. Eyal, MD,
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
CPAP Murila fv. Respiratory distress syndrome 28% of neonatal deaths are due to prematurity The most common respiratory disorder in the preterm is Respiratory.
DR MUHAMMAD BILAL NON INVASIVE VENTILATION. DEFINITION : - DELIVERY OF MECHANICAL VENTILATION TO THE LUNGS THAT DON’T REQUIRE ET.T. OR TRACHEOSTOMY IRON.
Effect of different cycling off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive.
Non invasive Ventilation (NIV) MOHSIN ED,SRH. Non Invasive Ventilation(NIV) Delivery of ventilation to the lungs without an invasive airway (endotracheal.
RESPIRATORY SYSTEM (Lungs Compliance)
Respiratory Function, Breathing, Respiration BI 233 Exercise 40.
Passy Muir Valve Speaking Valve for Tracheostomy Patients Deidre Dennison, RN Vascular Intensive Care How it WorksContraindications Benefits InitiationMaking.
Neonatal A & P RC 290. Neonate Compared to Adult  More compliant and flexible thorax  Large tongue  Large U-shaped epiglottis  Narrowest part of upper.
Mechanical Ventilation EMS Professions Temple College.
Mechanical Ventilation Mary P. Martinasek BS, RRT Director of Clinical Education Hillsborough Community College.
Chapter 14 Respiratory Procedures. Copyright © 2007 Thomson Delmar Learning. ALL RIGHTS RESERVED.2 Patients at Risk for Poor Oxygenation Hypoxemia –Insufficient.
 Understand the different breath types with SIMV  Know the Phase variables of the different breath types: trigger/limit/cycle  Know the breath sequence.
Human Respiratory System Hanes Magnet School 7 th Grade Science Mr. Bombick.
Mechanical Ventilation 1
Respiratory Distress Syndrome Hyaline Membrane Disease
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
Atelectasis.
Ventilatory Modes Graphnet Ventilator.
Principles of Mechanical Ventilation Mazen Kherallah, M.D., FCCP Internal Medicine, Critical Care Medicine, and Infectious Diseases Initial Ventilatory.
PRESSURE CONTROL VENTILATION
Mechanical Ventilation
Principles of Mechanical Ventilation Magdy M Khalil, MD, EDIC Prof. Pulmonary& Critical Care Medicine.
+ Non-invasive Positive Pressure Ventilation (NPPV) Basheer Albahrani, RT.
Mechanical Ventilation
Mechanical ventilator
Management of Pulmonary Conditions
Introduction to ventilation
You could ventilate a patient
Mechanical ventilator
MECHANICAL VENTILATION
Presentation transcript:

Biphasic Cuirass Ventilation (BCV) The United Hayek Hayek RTX

Conventional mechanical ventilation In positive pressure ventilation (PPV), the gas pushed into the lungs naturally follows the path of least resistance, therefore ventilating the already well ventilated areas. Increases in pressures/volumes to aid ventilation of all areas of the lungs leads to barotrauma, volutrauma and possible development of a pnuemothorax. These complications, along with those of ventilator associated pneumonia, are of no relevance with biphasic cuirass ventilation (BCV).

How the Cuirass (BCV) is different The pressure applied within the cuirass acts uniformly over the thorax, thus lung expansion is also uniform, ventilating all areas of the lungs. A negative pressure is generated within the chest cuirass for inspiration or continuous inspiratory assistance A positive pressure within the cuirass induces expiration, making the Hayek RTX particularly efficient at CO2 clearance BCV in conjunction with PPV is used as an aid to weaning, to increase right ventricular function and to aid in expansion of areas of collapse No risk of VAP, barotrauma or infection. No additional sedation required. Allows patients to eat, drink and talk while fully supported unlike any other form of invasive or non-invasive ventilation.

Who would benefit from BCV? Patients with any of the following: Acute Respiratory Failure Chronic Obstructive Pulmonary Disease (COPD) Neuromuscular (e.g. SMA, Duchennes, etc.) Head and Spinal Injuries Problems with Weaning from PPV Ventilation during anesthesia in Ear Nose and Throat (ENT) Procedures Cystic Fibrosis (CF), and those who require physiotherapy Aids Related Lung Disease Asthma Ventilation post-operation (i.e., post-coronary bypass, Fontan/Glenn, post-pneumonectomy)

Modes of ventilation with BCV Continuous negative pressure (CNEP) Used in conditions with increased work of breathing, small airways disease, V/Q mismatching and those infants who may tire easily post extubation. Start your CNEP roughly 2cms H2O more than you would CPAP. This level is then adjusted until the increase work of breathing decreases. This will be noted clinically with decreased retractions, decreased use of expiratory muscles, resolving metabolic acidosis, stable or falling CO2 and improved oxygenation. Weaning from CNEP can be initiated by bringing down the level of CNEP, then taking the patient off for controlled periods. These are gradual lengthened to suit the patient. CNEP helps improve right ventricular function, especially when used in conjunction to PPV. This mode of support can be easily adjusted/manipulated to suit the individual patients

Modes of ventilation with BCV (cont.) Control Mode This mode provides full control over the patient' s respiration Mandatory respiratory rate is set and delivered; patient’s own respiratory muscles are used to breath. This is a unique function of the Hayek RTX as it mimics physiological respiration. Controls both inspiratory and expiratory phases by setting the I:E ratio Commence rate at 2 above their own current spontaneous rate, then can slowly decrease the rate as patients breathing controlled by Hayek RTX

Modes of ventilation with BCV (cont.) Respiratory synchronized This mode is fully synchronized with the patients own respiration, automatically adjusting with the natural breathing adjustments being made by the patient themselves. The patient' s inspiratory effort creates an initial trigger which is followed by a further trigger by the initial effort of expiration. The trigger can be either through the cuirass or airway. Difference between this mode at respiratory triggered is that on this mode the support is timed with patients own respiratory pattern, so no I:E ratio is set by the provider The I:E ration will be calculated and displayed This mode will allow the patient to breathe both at their own rate and determine their own pattern. In the event of apnea the Hayek RTX will deliver the set back up rate delivering fully controlled ventilation at the pressures set

Modes of ventilation with BCV (cont.) Secretion Clearance should be used when there is atelectasis, excess secretions or CO2 retention. It is divided into two parts: Vibration mode This mode shakes and thins secretions Similar effect as IPV treatments Cough mode This mode assists with expelling the secretions Can act as a mini sustained inflation (similar to HIT) The negative pressure can be made more negative as required. Completion of both modes represents one cycle of secretion clearance mode.

Hayek RTX Respirator cuirass

Nursing Considerations The air within the cuirass can cause the patient (especially infants) to be at risk of temperature loss. Dress patients in pajamas or warm clothes (without buttons as these can affect the seal on the cuirass), or place them under a radiant heater or bair hugger Lines on the patient’s chest (chest tubes, CVL, g-tube, etc.) will need to have skin protection such as duoderm where they exit the seal EKG leads should be placed on the patient’s limbs or back outside of the chest cuirass Skin must be carefully inspected around the chest cuirass seal to look for redness or breakdown

Nursing Considerations (cont.) Each time the cuirass is removed and reapplied, always start in continuous negative pressure (CNEP).  That is the only way to get a seal before you connect the straps to the shell.  Even if you are using another mode, you must start with CNEP. Apply the cuirass shell using a rocking motion, either top to bottom or side to side. Avoid pushing the cuirass straight down on the patient as this can damage the foam and cause skin breakdown. Oxygen must be provided via another source, and the patient must be able to maintain a patent upper airway Charting modes and settings will be via “sticky note” until built into HED