Chapter 9 Safety.

Slides:



Advertisements
Similar presentations
Amateur Radio Technician Class Element 2 Course Presentation ELEMENT 2 SUBELEMENTS T1 - FCC Rules, station license responsibilities T2 - Control operator.
Advertisements

Introducing Electricity and Electrical Safety
Introducing Electricity and Electrical Safety
Electrical Safety.
Technician License Course Chapter 9 Lesson Module 22 Mechanical Safety.
Technician Licensing Class Safety First!. T0A6 A good way to guard against electrical shock at your station: Use three-wire cords and plugs for all AC.
Safety Chapter 9 includes: Electrical safety RF Exposure Antenna Safety.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Electrical Power Systems
Chapter 8 Electrical and RF Safety Basic Safety Have a master on/off switch for your station. Don’t work on “live” equipment. Check with a meter first.
Technician License Course Chapter 9 Lesson Module 18 – Safety and Amateur Radio.
Chapter 4 – Ohm’s Law, Power and Energy Introductory Circuit Analysis Robert L. Boylestad.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
April 12, Alternating current (AC) used in homes and industry is produced by large electric generators in power stations Transformers are used to.
Chapter 10 – Electrical, Antenna Structure and RF Safety Practices
General Licensing Class G0A – G0B Electrical and RF Safety Your organization and dates here.
Lesson 7 Safety.
Release 1.0 – September Electrical Safety Amateur radios operated at high power produce dangerous and potentially deadly voltages and current. For.
Technician License Course Chapter 9 Lesson Module 21 Radio Frequency Exposure.
G0 - RF Safety G0 – ELECTRICAL AND RF SAFETY [2 Exam Questions - 2 groups] G0A - RF safety principles, rules and guidelines; routine station evaluation.
Safety Al Penney VO1NO. Typical Home Electrical Service Meter Black Red White Fuses High Voltage 240 Volts 120 Volts 120 Volts Hot Neutral.
Copyright  Progressive Business Publications Electrical Safety.
SUBELEMENT T10 Electrical safety: AC and DC power circuits; antenna installation; RF hazards [3 Exam Questions - 3 Groups] 1Electrical Safety 2014.
Home Electrical Wiring Types of Receptacles and Wiring them for 120v – 15Amp/20Amp.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
1 Amateur Radio Technician Class Element 2 ELEMENT 2 SUBELEMENTS T1 - FCC Rules, station license responsibilities T2 - Control operator duties T3 - Operating.
SUBELEMENT G10 ELECTRICAL AND RF SAFETY [2 Exam Questions–2 Groups] G0 - RF Safety1.
Chapter 11 Safety Gordon, AH6DA. Safety Three Hazardous materials: – PCBs (polychlorinated biphenyls) insulating oil used in electronic gear. (Transformers,
General Licensing Class RF & Electrical Safety Your organization and dates here.
SAFETY. Safety Building and operating a “ham” radio station is a perfectly safe pastime However, carelessness can lead to severe injury, burns, or even.
Physics 106 Lesson #17 Home Wiring
Hi-Landers Ham Class Instructed by Rich Bugarin W6EC.
 A medium that provides a means for transferring energy from one place to another  It is not expensive or difficult to control the risk of an electrical.
Practice Questions 2015 General License Course. Which wire or wires in a four-conductor connection should be attached to fuses or circuit breakers in.
Electrical and RF Safety. Electrical Safety Generators Generators convert mechanical energy to electrical energy. They actually consist of two devices:
Electrical Safety around the Home and farm
Technician License Course Module Eighteen Electrical and RF Safety
Electrical and RF Safety
Unit 3 Lesson 3 Electric Circuits
Electrical Engineering for Physicists How to get from the 208 VAC 3-phase power in the building to 110- and 220-VAC Code issues All work must be done in.
How to Enjoy Ham Radio and Live While Doing it.
Circuit Protection Unit 9.
AMATEUR RADIO TRAINING
Basic Electrical Safety
General Licensing Class
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Radio Equipment Chapter 4 RADIO EQUIPMENT
Electrical Safety around the Home and farm
Personal Protective Equipment
Technician Licensing Class
Technician Licensing Class
Unit 3 Lesson 3 Electric Circuits
Technician Licensing Class
CHAPTER 16 SAFETY.
AMATEUR RADIO TRAINING
Chapter 4 – Ohm’s Law, Power and Energy
Basic Electrical Safety
Click anywhere to get started…
Basic Electrical Safety
A. Touching both terminals with the hands can cause electrical shock
A. At all times except when climbing the tower
What type of radiation are VHF and UHF radio signals?
Jeremy P. Carlo Department of Physics
Roanoke Valley Amateur Radio Club
Technician License Course Chapter 9
WELCOME.
NATE Tower Site Hazard Recognition Guide
American Radio Relay League
Presentation transcript:

Chapter 9 Safety

Chapter 9 Electrical Safety Working safely with electricity mostly means avoiding contact with it. Compared to many activities, amateur radio is one of the safest hobbies because most hams educate themselves about safety and follow some simple rules. A little common sense goes a long way. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Electrical Injuries Electrical hazards produce two types of injury: Shocks Burns Whenever electricity flows through any part of your body both can occur (AC or DC). 4/24/2019 7/1/2014 - 6/30/2018 Technician

Effects of Electric Current in the Human Body (table 9-1, pg 9-2) Chapter 9 Electrical Safety Electrical Injuries Effects of Electric Current in the Human Body (table 9-1, pg 9-2) Current Reaction Below 1 milliampere Generally not perceptible 1 milliampere Faint tingle 5 milliamperes Slight shock; not painful but disturbing, Involuntary reaction 6-25 milliamperes (Women) 9-30 milliamperes (Men) Painful shock, loss of muscular control; “can’t let go” range. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Electrical Injuries The most dangerous currents are those that flow through the heart: Hand-to-hand Hand-to-foot A current of 100 mA or more can disrupt normal heart rhythm. Voltages as low as 30 volts can cause enough current flow to be dangerous. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Avoiding Electrical Hazards Never work on “live” equipment unless it is absolutely necessary (e.g., Troubleshooting or testing). Never assume equipment is off or de-energized. Check with a meter or tester first. Capacitors in a power supply can store hazardous voltage after the charging circuit is turned off. Test with a meter Use a grounding stick to shunt the charge to ground. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Avoiding Electrical Hazards If you have to work on “live” equipment follow these guidelines: Keep one hand in your pocket when probing or testing energized equipment. Never bypass a safety interlock unless specifically instructed to do so. Remove your jewelry when working on electronics. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Response to Electrical Injury If you or someone receives an electrical shock… Turn off the power – don’t touch the person while they are in contact with electricity or you will be the next victim. Install a clearly-labeled master ON/OFF switch for the circuit to your ham shack. Show your family how to turn off power at the switch AND at the circuit breaker box. You and your family should consider learning CPR and first aid for electrical injuries. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety AC Safety Grounding Most ham stations DO NOT require new wiring and can operate safely when powered from your home’s ac wiring. You just have to follow some simple guidelines: Use three-wire power cords that connect the chassis of your equipment to the ac safety ground. Use Ground Fault Circuit Interrupter (GFCI) circuit breakers. Use a circuit tester to verify proper wiring 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety AC Safety Grounding NEVER replace a fuse or circuit breaker with one of a larger size. (table 9-2, pg. 9-4) Don’t overload single outlets. If new wiring is required, hire an electrician do it or at least inspect your work. Be sure to follow the “Hot-Black” (occasionally Red), “Neutral-White”, “Ground-Green” (or bare wire) wiring standard 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety AC Safety Grounding Use cable and wire sufficiently rated for the expected current load. (table 9-2, pg 9-4) Use the proper size fuses and circuit breakers. If you build your own equipment, always install a fuse or circuit breaker IN SERIES with the ac “hot” conductor. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Lightning Lightning strikes amateur towers and antennas NO MORE frequently than tall trees or other structures. However, common sense must prevail and there are some things you should do regardless of where you live. Ground all towers, masts and antenna mounts Ground at the base or if roof-mounted, use a large diameter wire to a ground rod (#8 copper wire to 8’ copper-clad ground rod of 5/8” diameter). Ground connections should be as short as possible and avoid sharp bends. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 Electrical Safety Lightning When lightning is anticipated, disconnect all cables outside the house. Unplug equipment power cords inside the house. Operating during a thunderstorm is never a good idea. A nearby strike can create a voltage surge of thousands of volts in a power line or phone line. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure After many studies done at power line frequencies (50 and 60 Hz) and radio frequencies of RF (shortwave, including amateur frequencies and mobile phone), NO LINK has been established between low-level electromagnetic radiation and health risks. At the relatively low frequencies used by radio amateurs, RF energy is “non-ionizing radiation”. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure The FCC has set limits on the “Maximum Permissible Exposure” (MPE) from radio transmitters of any sort. Hams are required to evaluate their stations to see if their operation has the potential to exceed MPE levels. RF energy can ONLY cause injury to the human body IF the combination of frequency and power causes excessive energy to be absorbed. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure When the human body absorbs RF energy, heating occurs. RF energy causes the molecules in the body to vibrate at the same frequency. The energy of the vibration is dissipated as heat. Absorption of RF energy varies with the frequency because the body absorbs more RF energy at some frequencies than others. The human body absorbs more RF energy at VHF frequencies than any other part of the RF spectrum. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure The FCC has established safe levels of RF exposure – Maximum Permissible Exposure (MPE) levels. MPE and absorption rates vary with frequency. Absorption rates vary with the size of the body or body part and is highest where the body is naturally resonant. The full body is resonant at about 35 MHz if grounded and about 70 MHz if not grounded. Body parts are resonant at higher frequencies (e.g., an adult’s head is resonant at about 400 MHz). 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure In a “controlled” environment people are aware of the their exposure and can take the necessary steps to minimize it: the FCC has determined that the “controlled” environment generally applies to amateur operators, their family members and their guests and is limited to your home and property. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure People in “uncontrolled” environments are not aware of their exposure – areas open to the general public and your neighbor’s property – and their risk of exposure is generally less than in “controlled” environments. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure Exposure limits are based on averages rather than peak exposure. The averaging period for controlled environments is 6 minutes. The averaging period for uncontrolled environments is 30 minutes The difference in averaging periods reflects the difference in how long people are expected to be present and exposed. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure Duty cycle is the ratio of the transmitted signal’s on-the-air time to the total operating time during the measurement period. The maximum is 100% (Duty Cycle: Table 9-4, pg. 9-14) For most amateur contacts, the transmitter is keyed no more than 50% of the time and usually much less which in turn lowers the “duty cycle” of the emissions. Because duty cycle affects the average power level of transmissions, it must be considered when evaluating exposure. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure Antenna Gain is the last piece of the puzzle that we must consider. Beam antennas focus radiated power toward one direction which results in increased gain. Therefore, gain increases your average power in the preferred direction. There are four factors that affect RF exposure; Transmitter power Frequency Distance to the antenna Radiation pattern of the antenna 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure With the exception of mobile and hand held transceivers, the FCC requires all fixed stations be evaluated for RF exposure. Most evaluations use the techniques outlined in the FCC’s Office of Engineering Technology (OET) Bulletin 65. Uses tables and simple formulas to determine if your station has the potential of causing an exposure hazard. The use of computer modeling is acceptable. http://hintlink.com/power_density.htm 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure Once you’ve done an evaluation you do not need to do another unless you change equipment that affects the average output power (e.g. added an amplifier or increased antenna gain). You’ll also need to reevaluate if you add a new frequency band. If your transmitted power (PEP) is less than the levels indicated below on the frequencies you operate, then no evaluation is required. The FCC has determined that the risk of exposure from those levels is too small to create an exposure risk: 4/24/2019 7/1/2014 - 6/30/2018 Technician

Power Thresholds for RF Exposure Evaluation Chapter 9 RF Exposure Power Thresholds for RF Exposure Evaluation Band Watts 160 m 500 15 m 100 70 cm 70 80 m 12 m 75 33 cm 150 40 m 10 m 50 23 cm 200 30 m 425 6 m 13 cm 250 20 m 225 2 m SHF (all bands) 17 m 125 1.25 m If you need to do an evaluation, you can use on-line exposure calculators and pre-calculated tables. You’ll need to know the frequency and power level, distance from the antenna and the antenna’s radiation pattern. 4/24/2019 7/1/2014 - 6/30/2018 Technician

So what do you do if you find a potential hazard? Chapter 9 RF Exposure So what do you do if you find a potential hazard? Locate antennas away from where people can get close to them – you don’t want anyone to be able to touch the antenna. Raise the antenna – it usually improves your signal as well as being a good safety practice. Avoid aiming a beam antenna where people are likely to be. 4/24/2019 7/1/2014 - 6/30/2018 Technician

Chapter 9 RF Exposure Use a lower gain antenna. Reduce your transmitter power. 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! When installing a radio in your vehicle you want to preserve the safety you and your passengers: Secure all equipment inside the vehicle Use “control heads” (detachable front panels) Don’t install the radio where it diverts your attention from driving or can block your view. Don’t operate in heavy traffic Pull over to make complicated adjustment Know the traffic laws in your state 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Before you start installing a tower or an antenna on your property, check with your home owner’s association and also check any local zoning codes to ensure that it’s OK. If your tower exceeds 200 feet or you’re near an airport you’ll need to check with the FCC and the FAA. Place all antennas and feed lines clear of power lines including the service drop to your home. Ensure you have at least 10 feet of clearance beyond your mast or tower height from the nearest power line. 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Never attach an antenna or guy wire to a utility pole since a mechanical failure could result in contact with high-voltage wires. Follow your local electrical code when grounding antennas and support systems. Towers should be grounded with separate 8-foot long ground rods for each tower leg, bonded to the tower and to each other. 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Most antennas work better when installed as high as is practical and that usually means installing a tower or some sort. When working on a tower or as part of the ground crew, safety is absolutely critical. Each member of the crew should wear hard hats, goggles or safety glasses, and heavy gloves. 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! If you’re the “climber” use an approved climbing harness – DO NOT use a “lineman’s belt” – and work boots to protect the arches of your feet. Inspect all tower guying and support hardware. Repair or tighten before you climb. Crank-up towers must be fully nested in the retracted position and blocked. Never climb a crank-up tower supported only by its support cable. 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Double-check all climbing belts and lanyards. Make sure all clips and carabiners work smoothly and do not stick in the open or closed position. Make sure all ropes and load-bearing hardware are in good condition. Use a gin pole (a temporary mast that is attached to the tower) to hoist stuff (e.g., tools, parts, tower sections, antenna, etc.) up the tower. 4/24/2019 7/1/2014 - 6/30/2018 Technician

ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Chapter 9 Mechanical Safety ALWAYS FOLLOW THE MANUFACTURER’S DIRECTIONS! Double-check the latest weather reports. Avoid climbing alone whenever possible because it’s never safe. Make sure all power to the tower is turned off. Stay clear of the base of the tower unless you need to be there and never remove your hard hat until the climber is on the ground. 4/24/2019 7/1/2014 - 6/30/2018 Technician

The End Practice Tests!!!! Homework Chapter 9 Mechanical Safety 4/24/2019 7/1/2014 - 6/30/2018 Technician