How we do Spectroscopy An Overview

Slides:



Advertisements
Similar presentations
Good Practices of Fluorescence Spectroscopy
Advertisements

Optics and Telescopes Chapter Six. Telescopes The fundamental purpose of any telescope is to gather more light than the naked eye can In many cases telescopes.
Echelle Spectroscopy Dr Ray Stathakis, AAO. What is it? n Echelle spectroscopy is used to observe single objects at high spectral detail. n The spectrum.
Spectroscopy of Saturn
FMOS Observations and Data 14 January 2004 FMOS Science Workshop.
Observational Astrophysics II: May-June, Observational Astrophysics II (L2)
Observational Astrophysics II: May-June, Observational Astrophysics II (L2) Getting our NIRF What do want to do? 1.Image a selected.
LISA spectrograph Long slit Intermediate resolution Spectrograph for Astronomy Performances and application Christian Buil Active Spectroscopy in Astronomy.
Astronomical Spectroscopy
Optics and Telescopes Chapter Six.
Naoyuki Tamura (University of Durham) Expected Performance of FMOS ~ Estimation with Spectrum Simulator ~ Introduction of simulators  Examples of calculations.
Memorandam of the discussion on FMOS observations and data kicked off by Ian Lewis Masayuki Akiyama 14 January 2004 FMOS Science Workshop.
4. Telescopes Light gathering power and resolution Optical and radio telescopes Limitations of Earth’s atmosphere and satellite missions. Instruments (prism.
Chapter 6: The Tools of the Astronomer. Telescopes come in two general types Refractors use lenses to bend the light to a focus Reflectors use mirrors.
SPECTROSCOPIC DIAGNOSTIC COMPLEX FOR STUDYING PULSED TOKAMAK PLASMA Yu. Golubovskii, Yu. Ionikh, A. Mestchanov, V. Milenin, I. Porokhova, N. Timofeev Saint-Petersburg.
STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Spectroscopic Observations (Massey & Hanson 2011, arXiv v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration.
High Resolution Echelle Spectrograph for Chinese Weihai 1m Telescope. Leiwang, Yongtian Zhu, Zhongwen Hu Nanjing institute of Astronomical Optics Technology.
First results of the tests campaign in VISIBLE in VISIBLE for the demonstrator 12 October 2007 SNAP Collaboration Meeting Paris Marie-Hélène Aumeunier.
15 October Observational Astronomy Direct imaging Photometry Kitchin pp ,
18 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Optical Aeronomy Calibration Facility CEDAR WORKSHOP JUNE, 2007 Jeff Baumgardner, Center for Space Physics Boston University.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Astronomical Spectroscopy Notes from Richard Gray, Appalachian State, and D. J. Schroeder 1974 in “Methods of Experimental Physics, Vol. 12-Part A Optical.
Multi-slit spectroscopy In sky-noise dominated conditions (most interesting!) the use of slits is essential: eg: Faint object, extra-galactic, surveys:
Integral Field Spectroscopy. David Lee, Anglo-Australian Observatory.
NIRSpec Operations Concept Michael Regan(STScI), Jeff Valenti (STScI) Wolfram Freduling(ECF), Harald Kuntschner(ECF), Robert Fosbury (ECF)
JGR 19 Apr Basics of Spectroscopy Gordon Robertson (University of Sydney)
JWST Calibration Error Budget Jerry Kriss. 15 March 20072/14 JWST Flux & Wavelength Calibration Requirements SR-20: JWST shall be capable of achieving.
Data products of GuoShouJing telescope(LAMOST) pipeline and current problems LUO LAMOST Workshop.
WFIRST IFU -- Preliminary “existence proof” Qian Gong & Dave Content GSFC optics branch, Code 551.
Astronomy 1010-H Planetary Astronomy Fall_2015 Day-21.
Telescopes. Light Hitting a Telescope Mirror huge mirror near a star * * * small mirror far from 2 stars In the second case (reality), light rays from.
SNAP Calibration Program Steps to Spectrophotometric Calibration The SNAP (Supernova / Acceleration Probe) mission’s primary science.
REDSHIFT MEASUREMENT OF EXTREMELY BEAMED BL LAC OBJECTS. A PIECE OF EVIDENCE FOR TEV ASTRONOMY AND FUNDAMENTAL PHYSICS. Marco Landoni – Oss. Astronomico.
MOS Data Reduction Michael Balogh University of Durham.
Practical applications: CCD spectroscopy Tracing path of 2-d spectrum across detector –Measuring position of spectrum on detector –Fitting a polynomial.
DAO Observations and Instrumentation Jason Grunhut.
RAW DATA BIAS & DARK SUBTRACTION PIXEL-TO-PIXEL DQE CORR. LOCATE EXTR. WINDOW THROUGHPUT CORRECTION (incl. L-flat, blaze function, transmission of optics,
STScI Slitless Spectroscopy Workshop November 2010 aXe Advanced Topics – becoming more dextrous, using aXe with other instruments, making calibration.
CCD Image Processing: Issues & Solutions. CCDs: noise sources dark current –signal from unexposed CCD read noise –uncertainty in counting electrons in.
Atmospheric extinction Suppose that Earth’s atmosphere has mass absorption coefficient  at wavelength. If f 0 is flux of incoming beam above atmosphere,
F. Pepe Observatoire de Genève Optical astronomical spectroscopy at the VLT (Part 2)
Spectrometer The instrument used for the astronomers MinGyu Kim
A. Ealet Berkeley, december Spectrograph calibration Determination of specifications Calibration strategy Note in
Single Object Spectroscopy and Time Series Observations with NIRSpec
JWST-MIRIM (The MIRI Imager)
Single Object Slitless Spectroscopy Simulations
Astronomical Spectroscopic Techniques
NIRSpec Time Series Observations
Single Object & Time Series Spectroscopy with JWST NIRCam
NIRSpec pipeline concept Guido De Marchi, Tracy Beck, Torsten Böker
Charge Transfer Efficiency of Charge Coupled Device
Institute of Cosmos Sciences - University of Barcelona
Spectrophotometric calibration of the IFU spectrograph
Spectral Line Measurement
Summary Single Object & Time Series Spectroscopy Jeff Valenti JWST Mission Scientist Space Telescope Science Institute.
THE LHIRES-III SPECTROGRAPH
Introduction to Spectroscopy
4. Telescopes Light gathering power and resolution
Detective Quantum Efficiency Preliminary Design Review
Performances and application
Spectroscopy Workshop
My First steps in Slit spectroscopy
Observational Astronomy
Spectroscopic Observations (Massey & Hanson 2011, arXiv v2
X-ray high resolution spectra in the VO: the case of XMM-Newton RGS
Presentation transcript:

How we do Spectroscopy An Overview Spectroscopy Workshop N.L.O. 10th October 2015 Download from dropbox at http://tinyurl.com/NLO-workshop How we do Spectroscopy An Overview Robin Leadbeater www.threehillsobservatory.co.uk

HOW WE DO SPECTROSCOPY OVERVIEW Project Equipment Observations Data Reduction Measurements

The Project What is the target and what are we trying to find out about it ? What do we need to measure ? Wavelengths, resolution, SNR What precision and accuracy do we need ? How often and how long for ? Will data from several observers be combined ? Use common procedures and measure a standard reference Set up a group to coordinate observations and compare results Armed with this information we can then plan how best to proceed, identifying what will perhaps need particular attention, and what does not matter.

The Equipment The Spectrograph The universal spectrograph does not exist so may need to concentrate on specific project areas eg resolution/magnitude (or own two or more spectrographs !) Ancilliary equipment Cameras, wavelength calibration and flat lamps, control software The telescope and mount Match the spectrograph and telescope focal ratio Beware of chromatic aberrations Good tracking and guiding capability May need to consider load carrying capacity The Observatory Spectroscopy is much easier with a permanent setup Some spectrographs can be controlled remotely

Paton Hawksley Shelyak Star Analyser LHIRES III ~50A £100 10-0.3A Shelyak ALPY 10 A £500-1100-1600 Paton Hawksley Star Analyser ~50A £100 Shelyak LHIRES III 10-0.3A £2300 Elliot Inst CCDSpec 15 A £1300 JTW L200 12-0.9A £1300 Shelyak LISA 6 A £2300 As well as the Star Analyser and the LHIRES, there are now a selection of off the shelf spectrographs for the amateur which are increasing being used for Pro-Am work. Because we are spreading the light from a single star out so thinly spectroscopy needs a lot of light. The higher the resolution, the more light you need. So there is always a trade off between limiting magnitude and resolution (Even the very low resolution Star Analyser dilutes the starlight 100x or 5 magnitudes and the with LHIRES at 0.3A resolution, the factor is 10,000. or 10 magnitudes) not counting the efficiency losses in the instrument. Of course having more aperture always helps! Baader DADOS 15/2A £1400 Shelyak eShel 0.6A £11000

The resolution depends on:- A spectrograph produces a line of images of the light source at each wavelength Buil http://www.astrosurf.com/buil/staranalyser/obs.htm The resolution depends on:- The width of the light source image (eg FWHM of star image) How far the light is spread out (the linear dispersion)

Adding an entrance slit allows the width of the light source (and hence the resolution) to be controlled and kept constant The addition of a slit increases the complexity (and cost) of the instrument significantly compared with a simple slitless non objective grating spectrograph

With this simple insight we can immediately understand for example: Why higher resolution needs brighter targets How the spectrograph performance is affected by the telescope aperture and focal ratio How we can use slit width to trade sensitivity for resolution, particularly with extended objects Why poor seeing reduces resolution with slitless spectrographs but reduces throughput with slit spectrographs.

VERY APPROXIMATE LIMITING MAGNITUDE COMPARISON Resolution can be increased by increasing the dispersion But there is a trade off between resolution and sensitivity VERY APPROXIMATE LIMITING MAGNITUDE COMPARISON 200mm APERTURE 100 SNR The more the spectrum is spread out (higher dispersion) the brighter the target needs to be (Note this is for continuum spectra. High dispersion can be beneficial in the detection of narrow emission lines)

Spectroscopy needs a lot of light and anything done to maximise the number of photons ending up the spectrum can have a big payback. http://www.astrosurf.com/buil/alpy600/performances.htm http://www.astrosurf.com/aras/slit/method.htm Focusing and Guiding are crucial here - For commercial slit (and fibre fed) spectrographs for the amateur the mirror slit guider is now the (almost) universally adopted solution to this problem. (Self builders take note !)

Some other factors to consider Stability (thermal and flexure) Wavelength coverage resolution at the extreme ends of the spectrum (edge of field aberrations and chromatism in the optics can limit the useful wavelength range) Efficiency The efficiency and spectral response of a diffraction grating can vary from that published depending on the geometry Take care that that the spectrograph optics do not vignette the beam from the telescope. Camera QE and noise figure

The Observation Try to time the observations so the target and reference stars are measured close to the same air mass Take care not to saturate (combine multiple exposures to get enough signal in faint parts of spectrum) If your spectrograph shows thermal drift or flexure, take frequent wavelength calibration lamp spectra Don’t forget matching darks, flats. Can use cloudy nights if spectrograph is not disturbed (Average a large number to avoid adding noise)

Data Reduction Pre-processing Digitising (binning) Use fits files with completed headers from images to calibrated spectrum Pre-processing Darks, Flats Geometric corrections (tilt, slant, smile) Sky background removal Digitising (binning) Summing the pixel counts in each column for rows where there is spectrum data Wavelength calibration Calibration light source Heliocentric correction Flux calibration Rectification Instrument response (reference star) Atmospheric extinction (air mass) Radiometric (Spectrophotometry)

Measurements Using all the pixel values in the line to measure the line parameters not just the peak significantly increases precision Wavelength can be measured to small fraction of the resolution The area of the line gives a measure of the line strength which is more precise than the peak and independent of the spectrograph resolution (eg Equivalent Width)