Volume 4, Issue 1, Pages (March 2018)

Slides:



Advertisements
Similar presentations
Lateral Unicompartmental Knee Arthroplasty Through a Medial Approach by Alexander P. Sah, and Richard D. Scott J Bone Joint Surg Am Volume 89(9):
Advertisements

Total knee arthroplasty in multiple sclerosis
Growth of an intrapelvic pseudotumor associated with a metal-on-metal total hip arthroplasty after revision arthroplasty causing a femoral nerve neuropathy 
Volume 2, Issue 4, Pages (December 2016)
Volume 4, Issue 3, Pages (September 2018)
Volume 1, Issue 2, Pages (June 2015)
Simultaneous bilateral total hip arthroplasty in Morquio syndrome
False-negative synovial alpha-defensin
Proximal tibiofibular osteoarthritis presenting as pain after total knee arthroplasty treated successfully with fusion of the proximal tibial-fibular.
Volume 3, Issue 3, Pages (September 2017)
Samuel F. Thompson, BS, Blake E. Peterson, MD, Ajay Aggarwal, MD 
Custom titanium sleeve for surgical treatment of mechanically assisted crevice corrosion in the well-fixed, noncontemporary stem in total hip arthroplasty 
Colin D. Canham, MD, Christopher Walsh, MD, Stephen J. Incavo, MD 
Delayed diagnosis of catastrophic ceramic liner failure with resultant pelvic discontinuity and massive metallosis  Benjamin A. Winston, MD, Ryland P.
Volume 4, Issue 2, Pages (June 2018)
Volume 4, Issue 2, Pages (June 2018)
Circular hexapod external fixation for periprosthetic tibial fracture
Volume 4, Issue 3, Pages (September 2018)
Volume 4, Issue 2, Pages (June 2018)
Early fracture of the modular neck of a MODULUS femoral stem
Volume 4, Issue 1, Pages (March 2018)
Severe heterotopic ossification and stiffness after revision knee surgery for a periprosthetic fracture  Maher Baroudi, MD, Pascale Derome, MD, Michel.
Superior rim fracture of a vitamin E-infused highly cross-linked polyethylene (HXLPE) liner leading to total hip arthroplasty revision  Brett G. Brazier,
Traumatic anterior knee dislocation after total knee arthroplasty
A novel use of a tibial cone in a proximal femoral replacement
Lumbar chance fracture after direct anterior total hip arthroplasty
Failure of Emperion modular femoral stem with implant analysis
Zachary C. Lum, DO, Mauro Giordani, MD, John P. Meehan, MD
The cyclops lesion after bicruciate-retaining total knee replacement
Volume 4, Issue 2, Pages (June 2018)
Disassembly of the inner head of a bipolar hip prosthesis
Proximal tibial resorption in a modern total knee prosthesis
Total knee arthroplasty in patients with extra-articular deformity
Erin Honcharuk, MD, Stephen Kayiaros, MD, Lee E. Rubin, MD 
Bernd Fink, MD, Alexander Mittelstädt, MD
Volume 5, Issue 1, Pages (March 2019)
Volume 5, Issue 1, Pages (March 2019)
Volume 1, Issue 4, Pages (December 2015)
Sivana Leigh Barron, BA, Brian J. McGrory, MD, MS  Arthroplasty Today 
Tibial tray fracture in a modern prosthesis with retrieval analysis
Volume 2, Issue 4, Pages (December 2016)
Volume 2, Issue 3, Pages (September 2016)
Total knee arthroplasty in patients with multiple hereditary exostoses
Florian Dibra, MD, Hari Parvataneni, MD  Arthroplasty Today 
Antibiotic impregnated total femur spacers: a technical tip
Attique Vasdev, M. S. , Ashok Rajgopal, M. S. , M. Ch. , F. R. C. S
Volume 3, Issue 1, Pages 7-11 (March 2017)
Volume 1, Issue 4, Pages (December 2015)
Kevin T. Hug, MD, Navin D. Fernando, MD, FRCS(C)  Arthroplasty Today 
Volume 3, Issue 1, Pages (March 2017)
Retrieval analysis of a failed synthetic mesh extensor mechanism reconstruction after total knee arthroplasty  Anna Cohen-Rosenblum, MD, Ashley Volaric,
Volume 2, Issue 1, Pages 2-5 (March 2016)
Arthroprosthetic cobaltism associated with cardiomyopathy
Disassembly of the inner head of a bipolar hip prosthesis
Total knee arthroplasty in osteogenesis imperfecta
Rapidly destructive osteoarthritis can mimic infection
Abundant heterotopic bone formation following use of rhBMP-2 in the treatment of acetabular bone defects during revision hip arthroplasty  Alexander Arzeno,
Volume 3, Issue 4, Pages (December 2017)
Maarten Koper, MD, Rob Verdijk, MD, PhD, Koen Bos, MD, PhD 
Michael A. Yee, MD, Thomas J. O'Keefe, MD, Suzanne Winter, MS, CCRC 
Volume 5, Issue 1, Pages (March 2019)
Volume 3, Issue 4, Pages (December 2017)
Total knee arthroplasty in patients with extra-articular deformity
Volume 5, Issue 1, Pages 5-10 (March 2019)
Tibial tray fracture in a modern prosthesis with retrieval analysis
Abundant heterotopic bone formation following use of rhBMP-2 in the treatment of acetabular bone defects during revision hip arthroplasty  Alexander Arzeno,
Volume 2, Issue 4, Pages (December 2016)
Volume 5, Issue 3, Pages (September 2019)
Nontraumatic fracture of the polyethylene tibial post in a bi-cruciate stabilized total knee prosthesis  Daan Renson, MD, Wouter Lenaerts, MD, Johan Feyen,
Volume 5, Issue 2, Pages (June 2019)
Presentation transcript:

Volume 4, Issue 1, Pages 15-19 (March 2018) Early failure with massive metallosis and posteromedial wear following atraumatic anterior cruciate ligament rupture after medial unicompartmental knee arthroplasty  Ashok Rajgopal, MS, MCh, FRCS (Orth), Inayat Panda, MS, DNB (Orth), Vipin C. Tyagi, D-Orth  Arthroplasty Today  Volume 4, Issue 1, Pages 15-19 (March 2018) DOI: 10.1016/j.artd.2017.09.007 Copyright © 2017 The Authors Terms and Conditions

Figure 1 Immediate postoperative radiographs following index medial compartmental arthroplasty surgery showing well-fixed and well-aligned femoral and tibial components. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions

Figure 2 At 2 years of follow-up, anteroposterior and lateral radiographs of medial UKA knee showing posterior displacement of femur, absent medial joint space, and increased femorotibial contact area. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions

Figure 3 Intraoperative image showing black rubbery synovium due to massive metallosis. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions

Figure 4 Full thickness wear of the tibial polyethylene insert and metallic tray. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions

Figure 5 Polyethylene insert showing full thickness wear over the posterior half. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions

Figure 6 Metallic tibial component showing full thickness wear over the posterior one-third. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions

Figure 7 Postoperative radiographs after revision with a posterior-stabilized total knee prosthesis with tibial stem extension. Arthroplasty Today 2018 4, 15-19DOI: (10.1016/j.artd.2017.09.007) Copyright © 2017 The Authors Terms and Conditions