Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm marcus.palm@cern.ch AB-ATB-EA M. Palm, CERN.

Slides:



Advertisements
Similar presentations
MERIT Pump/Probe Data Analysis Outline  The pump/probe program  Particle detector response correction  Pump/probe analysis results NFMCC Collaboration.
Advertisements

May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
MARS15 Simulations of the MERIT Mercury Target Experiment Fermilab March 18, Neutrino Factory and Muon Collider Collaboration meeting Sergei.
M. Palm, CERN1 Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA.
Harold G. Kirk Brookhaven National Laboratory The MERIT High-Power Target Experiment Muon Collider Design Workshop BNL December 3-7, 2007.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Beam Loss Analysis Tool for the CTF3 PETS Tank M. Velasco, T. Lefevre, R. Scheidegger, M. Wood, J. Hebden, G. Simpson Northwestern University, Evanston,
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Photomultiplier Tube. What is it? Extremely sensitive detector of light in the ultraviolet, visible and near infrared Multiplies the signal produced by.
Scintillation Detectors
Hamamatsu R7525 HA: outer conductive coating with insulating sleeve CC: convex-concave window mm thick (standard plano-concave: 1mm center, 6.1.
Energy Resolution of a Parallel- Plate-Avalanche-Chamber Kausteya Roy Professors E. Norbeck and Y. Onel.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
TIDE TESTS AT GDD LAB M. Casiraghi and F. Vasi. New detector configuration Low pressure chamber anode.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
V. Vorobel, SuperNEMO meeting, Aussois Vacuum system upgrade Vacuum probe installed Spectrometer sealed – vacuum improved from 300 Pa to 7 Pa.
Status and first results of the KASCADE-Grande experiment
Status of the ETL 9125FLB Photomultiplier Tubes Steve Bache UNC-Wilmington.
Electron Cloud Mitigation Studies at CesrTA Joseph Calvey 10/1/2009.
Optical Receivers Theory and Operation
IEEE NSS 2007 D.Kramer 1 Very High Radiation Detector for the LHC BLM System based on Secondary Electron Emission Daniel Kramer, Eva Barbara.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Chem. 133 – 2/9 Lecture. Announcements Return Q1 + HW 1.1 This week’s seminar: on aerosol air pollution in Asia Lab –Sign up for term project instruments.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
FTOF Status Anton A. Izotov, Frascati
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
or getting rid of the give-away particles in a test-beam environment
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Scintillator testing in Prague (update from Aussois)
Studies at BINP Alexander Krasnov
Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors Lorenzo Vitale, Belle-II SVD collaboration INFN and Univ. Trieste, ITALY Requirements.
Present Read Out Chain for the PANDA Barrel DIRC
Upgrade of the scintillator testing station in Prague
Radiation Monitor: Concepts, Simulation for an Advanced Read Out
Start Detector for pion experiments
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Scintillation Detectors
IMAGE ORTHICON.
Development of the muon monitor for the T2K experiment
Setup for measurements with SCT128 in Ljubljana: SCTA128VG chip
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Chem. 133 – 2/9 Lecture.
Instrumentation for Colliding Beam Physics 2017
Particle Detection System for MERIT
Use of Beam Loss Monitor type detectors in CNGS muon station
Department of Physics and Astronomy,
Measured baseline fluctuations and dark counts with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.
Scintillation Counter
A summary of world-wide test beam facilities
Времяпролетный детектор PANDA
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Particle detection configuration
Particle Detection System for MERIT
The LHCb VErtex LOcator
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
Gain measurements of Chromium GEM foils
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm marcus.palm@cern.ch AB-ATB-EA M. Palm, CERN

ACEM Specifications Basically a regular photomultiplier, but with an aluminum foil as cathode (works as a secondary electron emitter when irradiated). 10 dynodes High voltage: 0.5-1.5 kV Max. current: 20 mA for short pulses Electron transit time: 40 ns Cathode surface area: 7 cm2 Positive aspects Simple operation Works with high rate if gain is low Easy to purchase Negative aspects Sensitive to magnetic field Read out HV(-) M. Palm, CERN

Test conditions Test in particle beam Test in magnetic field Tested in North Area, H2 – secondary particle beam from SPS. Proton beam: Intensity: ~108 particles per spill (4.8 s) Energy: 80 GeV Hadron intensity very low compared to MERIT (1:109) Test in magnetic field Detector placed inside dipole magnets; 0-450 Gauss. β-source (90Sr) H2 Plan for MERIT: Use very low gain with minimal HV. 4.8 s 16.8 s M. Palm, CERN

In-beam test Oscilloscope: TDS 744A, Tektronix Input resistance: 50 Ohm Sample speed: 2 GHz 8 bits resolution 600 V minimum HV for detectable signal Single pulse response: 1100 V 600 V M. Palm, CERN

Single pulses 50 Ω Results Rise times (20-90%): ~2.5 ns Fall times (90-20%): ~7 ns FWHM: ~5 ns Times independent of HV Pulse height: ~60 mV at 1100 V to ~1.5 mV at 600 V The mean value of the integrated pulses are to be taken with caution, since trigger level varies with HV (As seen in figure: two different trigger levels at 1100 V). To be repeated using a tuned source. 50 Ω M. Palm, CERN

Test with Hadron Beam Sample curves for one spill acquisition Sample speed: 5 kHz Memory: 50.000 samples Input resistance: 1 MΩ (slow integration) 1000 V 900 V 800 V M. Palm, CERN

Test with Hadron Beam Average signal N signals convoluted with unit step of t0=50 ms, to smooth out noise, then summed together 1000 V 900 V 800 V M. Palm, CERN

Test with Hadron Beam Statistics: Reliability Integrate signal for each curve i. Gives a number which (ideally) is equal to some number of electrons. Quotient between the integral and target intensity should be as constant as possible. Spill number Target intensity 0.63 0.61 M. Palm, CERN

Test with Hadron Beam Stability: 1000V 900V Stability: Histograms over the quotes fitted with Gaussians shows ~1% variation (σ/<x>). 800V M. Palm, CERN

Test with Hadron Beam Gain vs. HV The integrated signal decreases by a factor of ~40 when the HV is lowered from 1000 V to 600 V (red curve) 10log (Quote) M. Palm, CERN

Performance in magnetic field Motivation: 3 meters from the interaction region we have a magnetic field of ~300 Gauss. The detector must still function in this environment. Placing the detector closer to the solenoid should not be necessary. >9.7T >6.1T >3.9T >2.5T >1.6T >1.0T >0.68T >0.41T >0.26T >0.17T >0.11T >0.07T >0.04T >0.03T 221in (563cm) M. Palm, CERN

Performance in magnetic field In general, a photo-multiplier does not work beyond 50 G. To shield the ACEM from the B-field, we used up to 6 layers of μ-metal around the tube. Thickness: 1 mm/layer. Sheets of μ-metal Stainless steel-cylinder with taped top (used in magnet testing) Original tube (slightly ferromagnetic) Tape-covered paper tube (block day-light) M. Palm, CERN

Performance in magnetic field Setup To verify that the μ-metal shielding works, the detector was placed inside a dipole magnet in a secondary beam line from SPS. We used 90Sr as radiation source (β-). Since the original tube cover blocked too much of the radiation, it was replaced with a stainless steel cylinder covered with black PVC-tape. The detector signal was sent to a discriminator (threshold -31 mV) connected to a counter in order to see how the pulse rate decreases as the magnetic field gets stronger. N S Detector (radiation source barely visible here, but attached to the top) M. Palm, CERN

Performance in magnetic field Results Undisturbed by magnetic field up to ~200 G with 6 mm μ-metal The rate is halved at ~350 G independent of the bias voltage (with 6 mm μ-metal). This is not necessarily a disadvantage, since the general problem with particle detection in MERIT is that the particle flux is extremely high. Otherwise, we can just put more shielding around the tube. 1100 V 1300 V M. Palm, CERN

Conclusions Detector functions as expected in beam. Long term accuracy ~1%. Magnetic field from solenoid not an issue up to 300 Gauss. Use more μ-metal if we want to be closer to the interaction region. Good backup detector for use in MERIT. Outlook: Investigate how much HV to use in MERIT and detector behavior at this voltage level. PCVD-diamonds as particle detectors… M. Palm, CERN